Metalux

advertisement
Metalux
D ES C R IPTION
Type
Catalog #
The IAF Series is an energy efficient family of light duty industrials that
feature premium performance and durability. The series incorporates
sturdy embossed reflectors that precisely direct and effectively control
light. The IAF Series can be installed using various mounting methods
and numerous options and accessories are available. The series is
available with both Apertured (IAF) and Closed Top (ICF) reflector
combinations.
Project
Date
Comments
Prepared by
The IAF Series can be utilized in simple task and area lighting and
industrial applications.
S PEC IFIC A TION FEA T U R E S
Construction
E le ctrica l*
Reflectors
Nominal Channel is code gauge
prime cold rolled steel. Numerous
KOs for ease of installation. End
plate quickly connects to channel
connector. Groove for tong hanger
lamp holder bracket flips in place.
Ballast are CBM/ETL Class “P” and
positively secured by mounting
bolts. UL/CUL listed. Suitable for
damp locations.
Die formed prime steel, code
gauge. Formed edges for added
strength. 12” width. Reflectors
secured with quarter-turn
fasteners. All reflectors 4’ sections.
Baked white enamel. Standard
with 8% uplight (IAF). Closed top
reflector (ICF).
F in ish
Multistage iron phosphate
pretreatment ensures maximum
bonding and rust inhibitor. Lighting
grade, baked white enamel finish.
IAF, ICF
117, 217, 317,
128T8, 228T8,
328T8,
132, 232, 332
2', 4' OR 8' INDUSTRIAL
1, 2 OR 3 T8 LAMPS,
4-5/8"
[117mm]
Light Duty Industrial
12"
[305mm]
L AM P C ONFIGUR A TI O N S
1 LAMP
X
2 LAMP
4-5/8" [117mm]
3 LAMP
X
4-5/8" [117mm]
X=4-1/4"
[108mm]
Y=2-5/8"
[67mm]
12"
[305mm]
X
4-5/8" [117mm]
Y
12"
[305mm]
X=4-1/4"
[108mm]
Y=2-5/8"
[67mm]
Z=1-5/16"
[34mm]
Z
ENERGY DATA
Y
12"
[305mm]
Input Watts:
HB Ballast, Normal Ballast Factor
117 (17), 217 (25), 132 (30),
228T8 (49), 232 (53),
328T8 (71), 332 (80)
MOUNTING D A TA
4'
Y=5"
[127mm]
Y
KO for Gripple Toggle
7/8" [22mm]
K.O. (3)
Ceiling Stand-Off
Embossments
Ground Screw
4-1/4"
[108mm]
2'
Y=5"
[127mm]
Y
Ceiling Stand-Off
Embossments
Hole for Toggle
Ground Screw
X=3-1/2"
[89mm]
11/16" x 1"
KO (2 Places)
2" [51mm]
KO
X
3-1/4"
[83mm]
4-5/8"
[118mm]
48" [1220mm]
X=3-1/2"
[89mm]
11/16" x 1"
KO (2 Places)
X
24" [609mm]
8'
Y=5"
[127mm]
7/8" [22mm]
K.O. (2)
4-1/4"
[108mm]
Y
Ceiling Stand-Off
Embossments
Ground Screw
11/16" [17mm] K.O. (2)
3-1/4"
[83mm]
3/8" [10mm]
KO for
Gripple Toggle
Luminaire Efficacy Rating
LER = FL-80
Catalog Number: ICF-232
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $3.00
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
4-1/4"
[108mm]
X=3-1/4"
[83mm]
11/16" x 1" KO (2 Places)
2" [51mm] K.O.
X
24-1/2" [622mm]
96" [2438mm]
3-1/4"
[83mm]
4-5/8"
[118mm]
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF090176
2015-10-15 16:31:00
IAF/ IC F T 8
PH OTOM ETR IC S
Coefficients of Utilization
ICF-232
High Performance
Ballast
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
106
96
87
78
71
65
60
56
52
48
45
99
86
74
64
56
50
45
41
37
34
31
95
82
71
62
54
48
43
39
36
33
31
91
79
68
59
52
47
42
38
35
32
30
89
73
59
49
41
35
30
26
23
21
19
106
92
79
68
60
53
48
43
39
36
33
106
87
72
61
52
45
39
35
31
28
26
106
84
67
54
45
39
33
29
26
23
21
104 104 104 104
94 89 86 82
84 77 71 66
76 67 60 54
69 59 51 45
63 52 44 38
58 47 39 33
54 42 34 29
50 38 31 26
47 35 28 23
44 32 25 21
99
82
69
58
50
43
38
34
30
27
25
99
80
64
53
44
38
33
29
25
23
20
95
79
66
56
48
42
37
33
30
27
25
95
77
63
52
44
37
32
28
25
23
20
91
77
64
55
47
41
36
32
29
26
24
91
75
61
51
43
37
32
28
25
22
20
Two-F32T8/35K Lamps
Zonal Lumen Summary
2850 Lumens
Spacing criterion:
(II) 1.3 x mounting
height, ( ) 1.5 x
mounting height
Efficiency 89.2%
Test Report:
ICF-232.IES
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Lumens
1155.37
1949.47
3744.86
5061.97
22.24
5084.21
%Lamp
%Fixture
20.3
34.2
65.7
88.8
.4
89.2
22.7
38.3
73.7
99.6
.4
100.0
Angle
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
Along II
1433
1411
1341
1227
1076
890
673
432
175
2
0
0
0
0
0
0
0
0
0
45°
1433
1422
1377
1312
1223
1117
949
696
244
23
11
4
2
2
1
0
0
0
0
Across
1433
1429
1412
1387
1348
1247
1053
646
111
0
0
0
0
0
0
0
0
0
0
45°
840
835
818
797
781
766
743
714
683
651
622
594
564
530
460
361
175
56
0
Across
840
827
808
803
802
792
778
765
754
742
727
710
673
595
494
274
72
37
0
LER = FL-80
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.00
PH OTOM ETR IC S
Coefficients of Utilization
ICF-132
High Performance
Ballast
One-F32T8/35K Lamp
3100 Lumens
Spacing criterion:
(II) 1.3 x mounting
height, ( ) 1.4 x
mounting height
Efficiency 96.9%
Test Report:
ICF-132.IES
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
115
104
93
84
77
70
65
60
55
52
48
115
99
85
73
64
57
51
46
42
38
35
115
94
77
65
55
47
42
37
33
30
27
115
90
71
58
48
41
35
30
27
24
22
112
101
91
82
74
68
63
58
54
50
47
112 112 112
97 92 89
83 76 70
72 64 57
63 54 48
56 47 40
50 41 35
45 36 30
41 33 27
37 29 24
34 27 22
Candela
20%
50%
50 30 10
30%
50 30 10
107 107 107
92 89 86
79 73 69
69 62 56
60 53 47
54 46 40
48 40 34
43 36 30
40 32 27
36 29 24
33 26 22
103 103 103
89 86 83
76 71 67
66 60 55
58 51 46
52 45 39
46 39 34
42 35 30
38 31 26
35 29 24
33 26 21
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Angle
in Deg
45
55
65
75
85
Lumens
661.26
1109.36
2138.86
2997.95
0
2997.95
%Lamp
%Fixture
21.3
35.8
69.0
96.7
0
96.7
22.1
37.0
71.3
100.0
0
100.0
Average
0-Deg
cd/sm
4395
4330
4211
3760
1727
10%
50 30 10
0%
0
99
85
73
63
56
50
45
41
37
34
32
97
78
63
52
43
37
32
28
24
22
20
Average
45-Deg
cd/sm
4950
5568
6743
7500
3455
99
83
69
58
50
44
39
34
31
28
26
99
81
65
54
45
39
34
30
26
24
21
Average
90-Deg
fcd/sm
5642
6656
7570
5692
2283
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
840
840
832
816
792
762
724
680
632
578
522
463
400
331
259
181
98
28
0
LER = FL-88
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $2.73
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
ADF090176
2015-10-15 16:31:00
IAF/ IC F T 8
ORDER ING INFOR M A TION
SAMPLE NUMBER: ICF-232-UNV-HB81-U
Ballast Type (2)
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
No. of Ballast
1 or 2
EB8 /PLUS= T8 Electronic Instant Start.
High Ballast Factor >1.13.
Total Harmonic Distortion < 10%
No. of
Ballast 1 or 2
Tandem
Blank=2' or 4'
Length (1)
8T=8' Length
Series
IAF=Apertured
Reflector
ICF=Closed Top
Reflector
Packaging
Options
U=Unit Pack
6-3/18 SJT-C&P-515P=Cord & Plug
4B=4 Bulk
(3)
(120V), (15 AMP)
6-3/18 SJT-C&P-L715P=Cord & Plug (277V), (15 AMP)(4)
PI/CPI=Plug-In Option(5)
TILW=Tandem In-Line Wiring Option (Consult TILW Option Catalog Page)(4)
(See options & accessories)
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast
1 or 2
ER8 /PLUS= T8 Electronic Program Start.
High Ballast Factor >1.13.
Total Harmonic Distortion < 10%
No. of Ballast
1 or 2
Number of Lamps (Not Included)
1=1 Lamp
2=2 Lamps
3=3 Lamps
Wattage
17=17W T8 (24")
28T8=28W T8 (48") (3)
32=32W T8 (48")
HPT8 Ballast
Ballast
HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77
HB8 =T8 Electronic Instant Start. Ballast Factor .88
HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2
HR8 DIM=T8 Electronic Program Start Step Dimming.
Ballast Factor .88
HR8 L=T8 Electronic Program Start. Low Ballast Factor .77
HR8 =T8 Electronic Program Start. Ballast Factor .88
HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2
Voltage (2)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal Voltage 120-277 (3)
Options
GL=Single Element Fuse
GM=Double Element Fuse
EL4=Emergency Installed
EL8=Emergency Installed
(1)
A C C E S S O R I E S (Order Separately)
A-1-B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling
(Use 2 per fixture)
GRP-SSF=Gripper Hanger (Use 2 per fixture)
SCF=Fixed Stem Set (Specify Length)
SCS=Swivel Stem Set (Specify Length)
SCA=Adjustable 48" Stem Set
AYC-Chain/Set-U=Chain Hanger Set (Use 1 set per
fixture)
WG/ICF-4FT-U2=Wire Guard
CLC-SSF=Long Channel Connector SSF
TOGGLE=Single Toggle NO. 2 (Specify Length)
Y-TOGGLE=Y Toggle NO. 2 (Specify Length)
(2)
NOTES: Length of fixture (2' or 4') as determined by lamp wattage chosen. Products also available in non-US voltages and frequencies for international markets.
(4)
(5)
(5)
be specific. Exception EL4. Socket brackets left uninstalled. When utilizing 28W T8 lamps, HPT8 Ballast must be specified. Not available with HO lamps.
(3)
Not available when specifying emergencies, voltage must
Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
SH IP P ING D A T A
Catalog No.
IAF-117
IAF-217
IAF-132
IAF-232
8TIAF-232
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
Wt.
8 lbs.
8 lbs.
13 lbs.
13 lbs.
26 lbs.
ADF090176
2015-10-15 16:31:00
Download