Metalux D ES C R IPTION Type Catalog # The IAF Series is an energy efficient family of light duty industrials that feature premium performance and durability. The series incorporates sturdy embossed reflectors that precisely direct and effectively control light. The IAF Series can be installed using various mounting methods and numerous options and accessories are available. The series is available with both Apertured (IAF) and Closed Top (ICF) reflector combinations. Project Date Comments Prepared by The IAF Series can be utilized in simple task and area lighting and industrial applications. S PEC IFIC A TION FEA T U R E S Construction E le ctrica l* Reflectors Nominal Channel is code gauge prime cold rolled steel. Numerous KOs for ease of installation. End plate quickly connects to channel connector. Groove for tong hanger lamp holder bracket flips in place. Ballast are CBM/ETL Class “P” and positively secured by mounting bolts. UL/CUL listed. Suitable for damp locations. Die formed prime steel, code gauge. Formed edges for added strength. 12” width. Reflectors secured with quarter-turn fasteners. All reflectors 4’ sections. Baked white enamel. Standard with 8% uplight (IAF). Closed top reflector (ICF). F in ish Multistage iron phosphate pretreatment ensures maximum bonding and rust inhibitor. Lighting grade, baked white enamel finish. IAF, ICF 117, 217, 317, 128T8, 228T8, 328T8, 132, 232, 332 2', 4' OR 8' INDUSTRIAL 1, 2 OR 3 T8 LAMPS, 4-5/8" [117mm] Light Duty Industrial 12" [305mm] L AM P C ONFIGUR A TI O N S 1 LAMP X 2 LAMP 4-5/8" [117mm] 3 LAMP X 4-5/8" [117mm] X=4-1/4" [108mm] Y=2-5/8" [67mm] 12" [305mm] X 4-5/8" [117mm] Y 12" [305mm] X=4-1/4" [108mm] Y=2-5/8" [67mm] Z=1-5/16" [34mm] Z ENERGY DATA Y 12" [305mm] Input Watts: HB Ballast, Normal Ballast Factor 117 (17), 217 (25), 132 (30), 228T8 (49), 232 (53), 328T8 (71), 332 (80) MOUNTING D A TA 4' Y=5" [127mm] Y KO for Gripple Toggle 7/8" [22mm] K.O. (3) Ceiling Stand-Off Embossments Ground Screw 4-1/4" [108mm] 2' Y=5" [127mm] Y Ceiling Stand-Off Embossments Hole for Toggle Ground Screw X=3-1/2" [89mm] 11/16" x 1" KO (2 Places) 2" [51mm] KO X 3-1/4" [83mm] 4-5/8" [118mm] 48" [1220mm] X=3-1/2" [89mm] 11/16" x 1" KO (2 Places) X 24" [609mm] 8' Y=5" [127mm] 7/8" [22mm] K.O. (2) 4-1/4" [108mm] Y Ceiling Stand-Off Embossments Ground Screw 11/16" [17mm] K.O. (2) 3-1/4" [83mm] 3/8" [10mm] KO for Gripple Toggle Luminaire Efficacy Rating LER = FL-80 Catalog Number: ICF-232 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.00 *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. 4-1/4" [108mm] X=3-1/4" [83mm] 11/16" x 1" KO (2 Places) 2" [51mm] K.O. X 24-1/2" [622mm] 96" [2438mm] 3-1/4" [83mm] 4-5/8" [118mm] LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF090176 2015-10-15 16:31:00 IAF/ IC F T 8 PH OTOM ETR IC S Coefficients of Utilization ICF-232 High Performance Ballast rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 106 96 87 78 71 65 60 56 52 48 45 99 86 74 64 56 50 45 41 37 34 31 95 82 71 62 54 48 43 39 36 33 31 91 79 68 59 52 47 42 38 35 32 30 89 73 59 49 41 35 30 26 23 21 19 106 92 79 68 60 53 48 43 39 36 33 106 87 72 61 52 45 39 35 31 28 26 106 84 67 54 45 39 33 29 26 23 21 104 104 104 104 94 89 86 82 84 77 71 66 76 67 60 54 69 59 51 45 63 52 44 38 58 47 39 33 54 42 34 29 50 38 31 26 47 35 28 23 44 32 25 21 99 82 69 58 50 43 38 34 30 27 25 99 80 64 53 44 38 33 29 25 23 20 95 79 66 56 48 42 37 33 30 27 25 95 77 63 52 44 37 32 28 25 23 20 91 77 64 55 47 41 36 32 29 26 24 91 75 61 51 43 37 32 28 25 22 20 Two-F32T8/35K Lamps Zonal Lumen Summary 2850 Lumens Spacing criterion: (II) 1.3 x mounting height, ( ) 1.5 x mounting height Efficiency 89.2% Test Report: ICF-232.IES Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens 1155.37 1949.47 3744.86 5061.97 22.24 5084.21 %Lamp %Fixture 20.3 34.2 65.7 88.8 .4 89.2 22.7 38.3 73.7 99.6 .4 100.0 Angle 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 Along II 1433 1411 1341 1227 1076 890 673 432 175 2 0 0 0 0 0 0 0 0 0 45° 1433 1422 1377 1312 1223 1117 949 696 244 23 11 4 2 2 1 0 0 0 0 Across 1433 1429 1412 1387 1348 1247 1053 646 111 0 0 0 0 0 0 0 0 0 0 45° 840 835 818 797 781 766 743 714 683 651 622 594 564 530 460 361 175 56 0 Across 840 827 808 803 802 792 778 765 754 742 727 710 673 595 494 274 72 37 0 LER = FL-80 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.00 PH OTOM ETR IC S Coefficients of Utilization ICF-132 High Performance Ballast One-F32T8/35K Lamp 3100 Lumens Spacing criterion: (II) 1.3 x mounting height, ( ) 1.4 x mounting height Efficiency 96.9% Test Report: ICF-132.IES rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 115 104 93 84 77 70 65 60 55 52 48 115 99 85 73 64 57 51 46 42 38 35 115 94 77 65 55 47 42 37 33 30 27 115 90 71 58 48 41 35 30 27 24 22 112 101 91 82 74 68 63 58 54 50 47 112 112 112 97 92 89 83 76 70 72 64 57 63 54 48 56 47 40 50 41 35 45 36 30 41 33 27 37 29 24 34 27 22 Candela 20% 50% 50 30 10 30% 50 30 10 107 107 107 92 89 86 79 73 69 69 62 56 60 53 47 54 46 40 48 40 34 43 36 30 40 32 27 36 29 24 33 26 22 103 103 103 89 86 83 76 71 67 66 60 55 58 51 46 52 45 39 46 39 34 42 35 30 38 31 26 35 29 24 33 26 21 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 90-180 0-180 Angle in Deg 45 55 65 75 85 Lumens 661.26 1109.36 2138.86 2997.95 0 2997.95 %Lamp %Fixture 21.3 35.8 69.0 96.7 0 96.7 22.1 37.0 71.3 100.0 0 100.0 Average 0-Deg cd/sm 4395 4330 4211 3760 1727 10% 50 30 10 0% 0 99 85 73 63 56 50 45 41 37 34 32 97 78 63 52 43 37 32 28 24 22 20 Average 45-Deg cd/sm 4950 5568 6743 7500 3455 99 83 69 58 50 44 39 34 31 28 26 99 81 65 54 45 39 34 30 26 24 21 Average 90-Deg fcd/sm 5642 6656 7570 5692 2283 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 840 840 832 816 792 762 724 680 632 578 522 463 400 331 259 181 98 28 0 LER = FL-88 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.73 Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. ADF090176 2015-10-15 16:31:00 IAF/ IC F T 8 ORDER ING INFOR M A TION SAMPLE NUMBER: ICF-232-UNV-HB81-U Ballast Type (2) EB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 Tandem Blank=2' or 4' Length (1) 8T=8' Length Series IAF=Apertured Reflector ICF=Closed Top Reflector Packaging Options U=Unit Pack 6-3/18 SJT-C&P-515P=Cord & Plug 4B=4 Bulk (3) (120V), (15 AMP) 6-3/18 SJT-C&P-L715P=Cord & Plug (277V), (15 AMP)(4) PI/CPI=Plug-In Option(5) TILW=Tandem In-Line Wiring Option (Consult TILW Option Catalog Page)(4) (See options & accessories) ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 ER8 /PLUS= T8 Electronic Program Start. High Ballast Factor >1.13. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 Number of Lamps (Not Included) 1=1 Lamp 2=2 Lamps 3=3 Lamps Wattage 17=17W T8 (24") 28T8=28W T8 (48") (3) 32=32W T8 (48") HPT8 Ballast Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 Voltage (2) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (3) Options GL=Single Element Fuse GM=Double Element Fuse EL4=Emergency Installed EL8=Emergency Installed (1) A C C E S S O R I E S (Order Separately) A-1-B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling (Use 2 per fixture) GRP-SSF=Gripper Hanger (Use 2 per fixture) SCF=Fixed Stem Set (Specify Length) SCS=Swivel Stem Set (Specify Length) SCA=Adjustable 48" Stem Set AYC-Chain/Set-U=Chain Hanger Set (Use 1 set per fixture) WG/ICF-4FT-U2=Wire Guard CLC-SSF=Long Channel Connector SSF TOGGLE=Single Toggle NO. 2 (Specify Length) Y-TOGGLE=Y Toggle NO. 2 (Specify Length) (2) NOTES: Length of fixture (2' or 4') as determined by lamp wattage chosen. Products also available in non-US voltages and frequencies for international markets. (4) (5) (5) be specific. Exception EL4. Socket brackets left uninstalled. When utilizing 28W T8 lamps, HPT8 Ballast must be specified. Not available with HO lamps. (3) Not available when specifying emergencies, voltage must Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. SH IP P ING D A T A Catalog No. IAF-117 IAF-217 IAF-132 IAF-232 8TIAF-232 Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. Wt. 8 lbs. 8 lbs. 13 lbs. 13 lbs. 26 lbs. ADF090176 2015-10-15 16:31:00