COOPER LIGHTING - METALUX DESCRIPTION The HBL series is ideal for high mounting height industrial or retail applications. Advanced optical designs provide maximum performance from either T5 or T8 lamps. Optional uplight component produces excellent ceiling uniformity. HBL‘s high lumen package allows the benefits of fluorescent to be applied at high mounting heights that were traditionally exclusive to H.I.D. Benefits include exceptional color rendering, high system efficacy, 95% lumen maintenance, long lamp life, instant on/instant re-strike, economical dimming, and uniform brightness control. Typical HBL applications include retail, shopping malls, light industrial and recreational environments. ® Type Catalog # Project Date Comments Prepared by S P E C I F I C AT I O N F E AT U R E S C o n s t ru c t i o n Channel and end plates are constructed of die formed steel. The channel provides strength, numerous KOs for easy installation, and excellent thermal dissipation without any special or proprietary components. Stiffening brackets add additional strength and rigidity to channel and reflectors. E l e c t ri c a l The HBL comes with a standard Class "P" electronic ballast and twist-lock lampholders. UL/cUL listed for high ambient environments up to 55°C (131°F) for all lamp and ballast combinations listed. Suitable for damp locations. Finish Electrostatically applied baked white enamel finish is preceded by a multistage cleaning cycle, iron phosphate coating with rust inhibitor. Optics Die formed, segmented optical design optimizes performance across three distributions. Optical choices include a narrow distribution for aisles, medium distribution for assembly and loading areas, or wide distribution for general, open area lighting. An uplight option is offered to permit ceiling uniformity and allow for ample lamp and luminaire heat dissipation. Wa rra n t y When operated in high ambient conditions, the HBL is supported by a 5 yr/55°C and 3 yr/65°C ballast warranty for T5 and T8 (277V) options when used w/high temperature ballast in open, uplight configurations. To maximize your warranty, the HBL should be ordered with a high-temperature ballast in ambient environments that typically exceed 40°C (102°F). HBL SERIES 4 OR 6 T8 LAMPS High-Bay Industrial Open Luminaire 2-15/32" [63mm] 19-17/32" [496mm] E N E R G Y D ATA D I M E N S I O N TO P V I E W 4/6 LAMP 4/6 LAMP L A M P C O N F I G U R AT I O N S 4 LAMP 48-7/16" [1230mm] 2-15/32" [63mm] Input Watts: EB Ballast and STD Lamps 432=109 632=167 19-17/32" [496mm] 19-17/32" [496mm] Luminaire Efficacy Rating LER = 88 (White) LER = 90 (Specular Inserts) Catalog Number: HBL-632-UPL 6 LAMP 2-15/32" [63mm] 19-17/32" [496mm] 2-15/32" [63mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.67 *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. **Consult Pre Sales Technical Support. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADF081930 pc 2011-03-29 14:20:21 HBL T8 P H OTO M E T R I C S P H OTO M E T R I C S Candela HBL-632-N-UPL Narrow Distribution Angle Along II (2) Electronic Plus 0 6445 Ballasts 5 6418 (6) F32/T8/TL835 32W 10 6339 T8 lamps, 3100 lumens 15 6200 20 6008 Spacing criterion: 25 5761 (II) 1.3 x mounting 30 5464 height, (⊥) 1.0 x 35 5119 mounting height 40 4731 45 4302 Efficiency 95.9% 50 3840 Test Report: 55 3346 60 2827 HBL632NUPL.IES LER =90 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.67 65 70 75 80 85 90 Across ⊥ 6445 6322 5913 5455 5075 4736 4478 4363 4043 3636 3321 2987 2737 2614 2148 1622 1094 592 182 45° 6445 6359 6092 5715 5300 4910 4549 4178 3898 3674 3287 2841 2482 2118 1892 1543 1018 522 117 2286 1732 1179 654 201 3 C o e f fi c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 113 98 85 74 66 58 53 48 44 40 37 113 93 78 66 57 50 44 39 35 32 29 113 89 72 60 50 43 38 33 30 27 24 110 100 90 82 75 69 64 59 55 51 48 110 95 82 72 64 57 52 47 43 39 36 110 91 76 65 56 49 43 39 35 32 29 110 88 71 59 50 43 37 33 30 27 24 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens 4562 7330 12827 17094 17837 %Lamp 24.5 39.4 69.0 91.9 95.9 LER =88 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.73 70 75 80 85 90 Across ⊥ 4685 4692 4654 4594 4503 4374 4203 4000 3774 3562 3354 3150 2962 2707 2246 1685 1107 566 177 45° 4685 4674 4631 4555 4446 4303 4121 3909 3658 3377 3081 2785 2500 2230 1985 1569 1025 500 111 1384 975 569 200 3 C o e f fi c i e n t s o f U t i l i z a t i o n Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 113 103 93 85 77 71 66 61 57 53 50 HBL-632-W-UNV-EB82- C a n d e l a UPL Angle Along II Wide Distribution 0 4685 (2) Electronic Plus 5 4663 Ballasts 10 4608 (6) F32T8/835 32W T8 15 4512 20 4380 lamps, 3100 lumens 25 4209 Spacing criterion: 30 4000 (II) 1.3 x mounting 35 3762 height, (⊥) 1.3 x 40 3492 45 3195 mounting height 50 2870 Efficiency 90.5% 55 2527 60 2165 Test Report: 65 1781 HBL632WUPL.IES %Fixture 25.6 41.1 71.9 95.8 100.0 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 104 90 78 69 61 55 49 45 41 38 35 99 86 75 66 58 52 47 43 40 37 34 94 82 71 63 56 50 45 42 38 35 33 92 75 62 52 44 38 33 29 26 24 22 104 87 73 62 54 47 42 38 34 31 28 104 84 69 57 49 42 37 33 29 26 24 99 83 70 60 52 46 41 37 33 30 28 99 81 66 56 47 41 36 32 29 26 24 94 80 68 58 51 45 40 36 33 30 27 94 78 64 54 46 40 35 31 28 26 23 Luminance Data Angle in Deg 45 55 65 75 85 Average 0-Deg cd/sm 10283 9860 9142 7699 3898 Average 45-Deg cd/sm 8782 8372 8470 10076 10123 Average 90-Deg cd/sm 8691 8802 10454 10592 11480 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 106 96 86 78 71 65 60 56 52 48 45 106 91 78 68 60 53 48 43 39 36 33 106 106 87 83 72 66 60 54 52 45 45 39 40 34 35 29 31 26 28 23 26 21 103 93 83 75 69 63 58 54 50 47 44 103 88 76 66 58 52 47 42 38 35 32 103 84 70 59 51 44 39 34 31 28 26 20% 103 81 65 53 45 38 33 29 26 23 21 50% 50 30 10 30% 50 30 10 50 97 83 72 62 55 49 44 40 37 34 31 91 78 68 59 52 47 42 38 35 32 30 86 74 64 56 49 44 40 36 33 31 28 97 80 67 56 49 42 37 33 30 27 25 97 77 62 51 43 37 32 28 25 23 20 91 76 63 54 47 41 36 32 29 26 24 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 3714 6154 11290 15508 16834 %Lamp 20.0 33.1 60.7 83.4 90.5 %Fixture 22.1 36.6 67.1 92.1 100.0 Average 0-Deg cd/sm 7432 7247 6932 6196 3774 91 73 60 50 42 36 31 28 25 22 20 10% 30 10 86 72 60 52 45 39 35 31 28 25 23 Average 45-Deg cd/sm 7855 7987 8679 9971 9436 86 70 57 48 41 35 31 27 24 22 20 0% 0 83 68 55 46 38 33 28 25 22 20 18 Average 90-Deg cd/sm 8286 9033 10536 10708 10682 Modular F-Bay Power Supply Option Cooper Lighting’s F-Bay Modular Power Supply option is available for use with all F-Bay products. The modular power supply allows external fixture access for safe and easy servicing. There is no need to remove lamps or reflectors to disconnect fixture power with F-Bay Modular Power Supply. Access to the individual fixture’s power supply allows servicing without turning off all the fixtures, disrupting occupants. F-Bay Modular Power Supply is a time-saver in installation – simply plug & power. Code Compliance • UL/cUL Certified for Make/Break under load (UL2549) • Meets NEC requirements for ballast disconnect (NEC 410.73G) 1 • Allows for addition of Occupancy Sensor without hard connections 2 1. Modular Power Supply Receptacle supplied mounted into fixture Access Plate 2. Modular Power Cord & Plugs in 120, 277, 347, & 480V configurations for easy plug & power into existing supply No internal fixture access required for installation or disconnecting power Modular Motion Sensor Option supplied with Mounting Box and Modular Power Supply Receptacle • Receptacles complete with insulating/dust cap Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 ADF081930 pc 2011-03-29 14:20:21 HBL T8 O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: HBL-632-N-UNV-EB82-UPL-U Width Blank=20" wide 4 & 6 Lamp (nominal) Includes V Hangers for rapid installation(6) Voltage (1) UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage(7) 120V=120 Volt 277V=277 Volt 347V=347 Volt Series HBL=Linear High Bay Options Lamps Installed L8835=T8 Lamp, 85CRI 3500K L8841=T8 Lamp, 85CRI 4100K L8850=T8 Lamp, 85CRI 5000K HL=Add HL at end of lamp for high lumen lamps, T8 only GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed No. of Lamps 4=4 Lamps 6=6 Lamps Lamp Type 32=32W T8 Lamp (48" Long) Distribution N=Narrow Beam (Standard) M=Medium Beam W=Wide Beam Ballast Type (4) T8 Systems EB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS=T8 Electronic Instant Start. (7) High Ballast Factor >1.15. No. of Total Harmonic Distortion < 10% Ballast 1, 2 or 3 ER8 =T8 Electronic Program Rapid Start.(5) Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 ER8 /PLUS=T8 Electronic Program Start.(5) High Ballast Factor >1.15. No. of Total Harmonic Distortion < 10% Ballast 1, 2 or 3 NOTES: (1) Voltage must be specified when ordered with plugs or emergency ballasts. For MS option, indicate UNV (for 120V or 277V), 347V or 480V. use of MC or MPC cord accessories, specify voltage for plugs. (3) Cannot be combined with Modular Power Receptacle (MP). (4) T8 ballast systems suitable for operation in ambient environments up 131°F (55°C) in uplight configuration. (5) Recommended when using motion sensor options. (6) Can be used in high abuse applications such as gymnasiums. (7) 2/3 lamp ballast configuration in EB8/PLUS only for UNC version. (8) For MWS with MP, choose MP in fixture logic and then choose MWS accessory such as MDS6. (2) Requires Packaging Options UPL=Uplight Apertures on Reflector U=Unit Pack MP=Modular Power Receptacle PALC=Palletized (Used for all Cord or Cord and In Carton Plug options) (2), (8) MWS=Modular Wiring System (3) MS=360° or 180° Motion Sensor installed (120V through 347V, or 480V )(1) Accessories (order separately) HBL-SPM=Single Monopoint Hanger w/Hub RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop Y- TOGGLE=Y Mounting Toggle, #2 Cable (Specify 10' or 30') HBAYC-CHAIN/SET/U=(2) V-Hook Hanger, 36" Chain Sets w/S-Hooks MC3=3' Modular Power Cord MPC3=3' Modular Power Cord & Plug (Specify Voltage) MC6=6' Modular Power Cord MPC6=6' Modular Power Cord & Plug (Specify Voltage) MMS=360° or 180° Aisle Motion Sensor with Modular Power Receptacle (120-277V) (2) MDS6=6' Modular Power Cord with MWS 27DS18/2G06MP Connector (8) WG/HBL6-4FT-B=4/6 Lamp Wireguard w/Clips S H I P P I N G DATA Catalog No. HBL-432-UNV-UPL HBL-632-UNV-UPL Wt. 13.5 lbs. 15 lbs. Q U I C K S H I P O R D E R I N G I N F O R M AT I O N Quick Ship Ordering Information Sample Number: HBL432-MP-UPL-L5 Includes V Hangers for rapid installation(6) Quick Ship orders ship in 5 days in order quantities not to exceed 200 pieces. NOTE: Orders received after noon are entered on the following day. No. of Lamps 4=4 Lamps 6=6 Lamps NOTES: Ballast Type T8 Systems (4) Blank=(1) or (2) 120/277V T8 Instant Start Electronic, 1.15 BF PS=(1) or (2) 120/277V T8 Electronic Program Rapid Start, 1.15 BF (7) Lamp Type 32=32W T8 Lamps (48") Family HBL (7) Distribution Blank=Narrow Beam W=Wide Beam Recommended when using motion sensor options. (8) Requires use of Modular cord and plug accessories. Power Receptacle MP=Modular Power Receptacle (8) (9) Uplight Blank=No Uplight UPL=Uplight Lamping Blank=No Lamps L4=Lamps Installed 85+CRI 4100K L5=Lamps Installed 85+CRI 5000K L5HL=Lamps Installed 85+CRI 5000K, High Lumen (9) L5HL (3000 initial) 5000K T8 lamps installed. Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 ADF081930 pc 2011-03-29 14:20:21