COOPER LIGHTING - METALUX

advertisement
COOPER LIGHTING - METALUX
®
DESCRIPTION
The Arctic Bay Series is designed as a high efficiency solution to sub-zero
ambient environments found in cold storage and refrigerated facilities.
The Arctic Bay has been optimized to provide maximum performance
with lamp and ballast systems that tolerate colder ambient temperatures.
Primary applications include cold storage, refrigerated facilities and
environments with ambient temperatures as low as -20°F.
Type
Catalog #
Project
Date
Comments
Prepared by
S P E C I F I C AT I O N F E AT U R E S
Application
The Arctic Bay Series high lumen
package allows for the benefits of
fluorescent lighting to be applied at
high mounting heights that were
traditionally exclusive to H.I.D.
These benefits include exceptional
color rendering, high system
efficacy, 95% lumen maintenance,
long lamp life, instant on, optional
dimming, and uniform brightness
control.
E l e c t ri c a l *
Class P ballast, rated for -29°C to
90°C operation, wired to rotor
locked sockets. Optional passive
infra-red motion sensor is rated for
high humidity, low temperature
application. Sensor provides 1400
sq. ft. of coverage in mounting
heights up to 40'. See control chart
options at ambient temperatures
below 32˚F. UL/CUL listed and
suitable for damp location.
C o n s t ru c t i o n
Housing, end plates and socket
tracks are die formed cold rolled
steel. Die formed internal reflectors
are available in either a high
reflectance specular material or a
painted white polyester powder
coat finish. A sealed and gasketed
door frame in a clear or prismatic
A12 pattern lens provide for a
thermal environment for optimal
lamp operation.
Finish
Electrostatically applied baked
white polyester powder coat finish
is preceded by a multistage
cleaning cycle, iron phosphate
coating with rust inhibitor.
Optics
Die formed, segmented optical
design optimizes performance
across three distributions. Optical
choices include a narrow
distribution for aisles, medium
distribution for assembly and
loading areas, or wide distribution
for general, open area lighting.
Mounting
The fixture is suited for surface and
suspension mounting with optional
wire hook and chain set, HB-SPM
or cable mounting.
ARCTIC BAY
SERIES
17" X 48"
4, 5 AND 6 LAMP
Cold Storage High-Bay
Industrial Luminaire
4-5/16"
[109mm]
E N E R G Y D ATA
16-3/4" [427mm]
L A M P C O N F I G U R AT I O N S
Input Watts (@ 277V):
EB Ballast
454=229W
554=300W
654=346W
D I M E N S I O N TO P V I E W
Luminaire Efficacy Rating
LER = FI-54
Catalog Number: ABI-654T5-UNVEBT2-U
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $5.08
7/8" [23mm] K.O.
1/2" [13mm] K.O.
4 LAMP
4-5/16" [109mm]
X=3-1/2"
[89mm]
X
X
X
16-3/4" [427mm]
7/8" [23mm] K.O.
1/2" [13mm] K.O
5 LAMP
48-1/8" [1222mm]
4-5/16" [109mm]
X=2-13/32"
[61mm]
16-3/4"
[427mm]
X
Y
Y
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
** Consult Pre Sales Technical Support.
X
16-3/4" [427mm]
Y=2-25/32"
[70mm]
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
7/8" [23mm] K.O.
1/2" [13mm] K.O
6 LAMP
4-5/16" [109mm]
X=1-1/8"
[28mm]
Safe and convenient means of
disconnecting power.
Y
Y X Y
Y
16-3/4" [427mm]
Y=2-13/32"
[61mm]
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADF071257
2012-01-31 13:20:58
ABI
P H OTO M E T R I C S
ABI-654T5-UNV-EBTL2-U
Electronic Ballasts
(6) F54W T5HO lamps
26400 lumens
Spacing criterion:
(II) 1.1 x mounting
height, (⊥) 1.2 x
mounting height
Efficiency 65.1%
Test Report:
2AB-654T5-UNVEBT2.IES
LER =FL59
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.06
Candela
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
9670
9568
9513
9020
8661
7923
6907
6251
5582
5059
4194
3551
2901
2245
1665
1116
605
233
31
Across ⊥
9670
9524
9324
8718
8137
7197
5917
5059
4188
3538
2863
2384
1968
1545
1192
845
504
233
63
45°
9670
9543
9400
8844
8377
7588
6497
5809
5071
4466
3614
2952
2352
1778
1305
864
473
195
50
C o e f fi c i e n t s o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
78
69
61
54
48
44
40
36
33
31
29
78
66
57
49
43
38
34
31
28
26
24
78
64
53
45
39
34
30
27
24
22
20
76
70
64
59
54
50
47
43
41
38
36
76
67
59
53
48
43
39
36
33
30
28
Candela
Electronic Ballasts
(6) F54W T5HO lamps
26400 lumens
Spacing criterion:
(II) 1.1 x mounting
height, (⊥) 1.2 x
mounting height
Efficiency 69.5%
Test Report:
2AB-654T5-CL.IES
LER =FL63
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.81
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
8130
8092
7982
7798
7538
7204
6794
6317
5776
5168
4500
3783
3030
2261
1517
848
335
66
0
Across ⊥
8130
8289
8398
8179
7685
6844
5568
4145
3469
3096
2708
2344
2089
1928
1760
1077
501
106
0
45°
8130
8204
8279
8200
7895
7423
6751
5832
4601
3415
2812
2371
1925
1545
1251
1031
487
108
0
C o e f fi c i e n t s o f U t i l i z a t i o n
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
78
71
66
60
56
51
48
45
42
39
37
ABI-654T5-CL-UNVEBTL2-U
76
65
56
48
43
38
34
31
28
25
23
76
63
53
45
39
34
30
27
24
22
20
20%
50%
50 30 10
30%
50 30 10
50
72
64
57
51
46
42
38
35
32
30
28
69
62
55
49
44
40
37
34
31
29
27
66
60
53
48
43
39
36
33
30
28
26
72
63
54
47
42
37
33
30
27
25
23
72
61
51
44
38
34
30
27
24
22
20
69
60
52
46
41
36
33
30
27
25
23
69
59
50
43
38
33
30
27
24
22
20
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
%Lamp
%Fixture
6856
10426
16414
19532
19532
22.9
34.8
54.7
65.1
65.1
35.1
53.4
84.0
100.0
100.0
Average
0-Deg
cd/sm
11513
9962
8548
6939
4302
Average
45-Deg
cd/sm
10163
8282
6770
5372
3600
ABI-454T5-CL-UNVEBTL1-U
Candela
(2) Electronic Ballasts
(4) F54W T5HO lamps
26400 lumens
Spacing criterion:
(II) 1.1 x mounting
height, (⊥) 1.0 x
mounting height
Efficiency 62.8%
Test Report:
AB-454T5-CL.IES
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
LER =FL58
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.13
Along II
5741
5782
5778
5547
5531
5186
4798
4329
3989
3099
3120
2560
1999
1461
949
495
178
32
0
10%
30 10
66
58
51
45
40
36
32
29
27
25
23
0%
0
66
57
49
42
37
33
29
26
24
22
20
65
56
48
41
36
32
28
25
23
21
19
Average
90-Deg
cd/sm
8051
6688
5883
5254
4302
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
83
76
70
64
59
55
51
47
44
42
39
83
73
65
58
52
47
42
39
35
33
30
83
71
60
52
46
41
36
33
30
27
25
83
68
57
48
42
36
32
29
26
24
22
81
75
68
63
58
53
50
46
43
41
38
81
72
64
57
51
46
42
38
35
32
30
81 81
69 67
60 56
52 48
45 41
40 36
36 32
33 29
30 26
27 24
25 21
20%
50%
50 30 10
30%
50 30 10
50
77
69
61
55
49
44
40
37
34
31
29
74
66
59
53
47
43
39
36
33
31
29
71
64
57
51
46
42
38
35
32
30
28
77
67
58
50
44
39
35
32
29
27
25
77
65
55
47
41
36
32
28
26
23
21
74
65
56
49
43
39
35
32
29
26
24
74
63
54
46
40
35
32
28
26
23
21
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
%Lamp
%Fixture
6390
9871
15445
18344
18344
24.2
37.4
58.5
69.5
69.5
34.8
53.8
84.2
100.0
100.0
Average
0-Deg
cd/sm
11454
10336
8384
5135
1187
Average
45-Deg
cd/sm
7569
6478
5729
6243
1942
10%
30 10
71
62
55
48
43
38
34
31
28
26
24
71
61
52
45
40
35
31
28
25
23
21
0%
0
69
60
51
44
38
34
30
27
24
22
20
Average
90-Deg
cd/sm
6862
6404
7149
6521
1906
Across ⊥
5741
5670
5407
8718
5110
4312
3272
2463
1973
1466
1487
1309
1256
1148
792
463
102
21
0
45°
5741
5745
5649
5390
5385
4959
4301
3428
2711
1720
1595
1282
1035
851
733
452
183
26
0
C o e f fi c i e n t s o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
75
70
65
60
56
51
48
44
41
38
36
75
67
61
55
49
44
40
37
33
30
28
75
65
57
50
45
39
35
32
28
25
23
75
63
54
47
41
36
32
28
25
22
20
73
68
63
59
54
50
47
43
40
37
35
73
66
59
54
48
44
40
36
33
30
27
73
64
56
50
44
39
35
32
28
25
23
73
62
53
46
41
35
32
28
25
22
20
20%
50%
50 30 10
30%
50 30 10
50
70
63
57
52
47
42
39
35
32
29
27
67
61
55
50
46
41
38
34
31
29
26
64
59
53
49
44
40
37
34
31
29
26
70
62
55
48
43
38
34
31
28
25
23
70
60
52
46
40
35
31
28
25
22
20
67
60
53
47
42
38
34
31
28
25
22
67
59
51
45
40
35
31
28
25
22
20
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
%Lamp
%Fixture
4324
6484
9542
11049
11049
24.6
36.8
54.2
62.8
62.8
39.1
58.7
86.4
100.0
100.0
Average
0-Deg
cd/sm
11064
11265
8725
4832
917
Average
45-Deg
cd/sm
6138
5642
5082
4411
765
10%
30 10
64
58
52
46
41
37
33
30
27
24
22
64
57
50
44
39
34
31
28
25
22
20
0%
0
63
56
49
43
38
33
30
26
23
21
19
Average
90-Deg
cd/sm
5233
5762
6854
4514
612
Specifications and dimensions subject to change without notice.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801
ADF071257
2012-01-31 13:20:58
ABI
Thermal Performance
Cooper Lighting thermally tested each configuration to determine the optimal luminaire operating temperature range. When specifying
luminaires use the lowest temperature the luminaire will be exposed to during operating hours. Facility temperatures fluctuate and
luminaires exposed to temperatures less than stated are not recommended.
Freezer Temperature Ranges
To maximize energy efficiency, some facilities will operate chillers only during off-peak
40 ft.
hours. In this case the facility will chill the space to temperatures as low as -40°F (-40°C)
to maintain the targeted temperature during operating hours. Fluorescent luminaires
35 ft. @ -40°F (-40°C)
exposed to -40°F (-40°C) temperatures are not recommended. Energy efficient HID
30 ft.
sources may be a better alternative.
20 ft.
10 ft.
Temperature Control Capability
20 ft. @ -20°F (-29°C)
10 ft. @ -10°F (-23°C)
Cooper Lighting recommends the following lamp operation when
implementing a control system in colder ambient environments.
Arctic Bay (ABI) Series
-20°F (-29°C) – 0°F (-18°C)
Motion Sensor Options (# of Lamps Controlled)
Fixture
# Lamps
Lamp
Type
ABI-454T5
4 Lamp
T5HO
Not Recommended
2
ABI-554T5
5 Lamp
T5HO
Not Recommended
2
ABI-654T5
6 Lamp
T5HO
Not Recommended
2
0°F (-18°C) – 32°F (0°C)
Routine
Use
Occasional
Use (3)
Motion Sensor Options (# of Lamps Controlled)
Fixture
# Lamps
Lamp
Type
Routine
Use (1)
Occasional
Use (2)
ABI-454T5
4 Lamp
T5HO
2
ALL
ABI-554T5
5 Lamp
T5HO
2
2
ABI-654T5
6 Lamp
T5HO
2
4
32°F (0°C) – 50°F (10°C)
Motion Sensor Options (# of Lamps Controlled)
Fixture
# Lamps
Lamp
Type
Routine
Use (1)
Occasional
Use (2)
ABI-454T5
4 Lamp
T5HO
2
ALL
ABI-554T5
5 Lamp
T5HO
2
3
ABI-654T5
6 Lamp
T5HO
2
4
NOTES: (1) Luminaire achieves 40% or greater of relative light output at the indicated temperature in
under 60 seconds. (2) Luminaire achieves 40% to 80% of relative light output at the indicated temperature
in under 7 minutes. (3) Greater than 20 min. lamp options.
Specifications and dimensions subject to change without notice.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801
ADF071257
2012-01-31 13:20:58
ABI
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : ABI-654T5-UNV-EBT2-MS/OB-U
Series
ABI=Arctic Bay
No. of Lamps
4=4 Lamps
5=5 Lamps
6=6 Lamps
Lamp Type
49T5=49W T5HO Lamps (48")
51T5=51W T5HO Lamps (48")
54T5=54W T5HO Lamps (48")
Distribution
N=Narrow Beam (Standard)
M=Medium Beam
W=Wide Beam
Includes V Hangers for rapid installation
Shielding
Blank=Prismatic Acrylic
Lens w/Gasketed Door
Frame
CL=Clear Acrylic Lens
w/Gasketed Door Frame
Ballast Type
EBTL =T5 Linear Electronic Program Rapid
Start.
Total Harmonic Distortion < 10%
Minimum Start Temp. -20°F (-29°C)
No. of Ballast
1, 2 or 3
Voltage (1)
UNV=Universal 120/277 Voltage
UNC=Universal 347/480 Voltage
120V=120 Volt
277V=277 Volt
347V=347 Volt
480V=480 Volt
Options
C3=3' White Cord Fixture Attached
C6=6' White Cord Fixture Attached
MS/OB=360° or 180° Motion Sensor Installed,
Inner 2 Lamps Constant On (4L, 5L) (2)
Inner 4 Lamps Constant On (6L) (2)
MS/IB=360° or 180° Motion Sensor Installed,
Outside Lamps Constant On (2)
PC3-Voltage=3' Cord/Plug Fixture Attached(1)
PC6-Voltage=6' Cord/Plug Fixture Attached(1)
Options
Lamps Installed
L5830=T5 Lamp, 85CRI 3000K
L5835=T5 Lamp, 85CRI 3500K
L5841=T5 Lamp, 85CRI 4100K
L5850=T5 Lamp, 85CRI 5000K
GL=Single Element Fuse
GM=Double Element Fuse
EL=Emergency installed (1)
Packaging
U=Unit Pack
PAL=Job Pack Out of Carton
PALC=Job Pack In Carton
Accessories (order separately)
HBAYC-CHAIN/SET/U=(2) V-Hook Hanger,
36" Chain Sets w/S-Hooks
HB-SPM=Single Monopoint Hanger w/Hub
RH-1=Retrofit Hanger
FH-1=Fixture Hook
FL-1=Fixture Loop
Y-TOGGLE=Y Mounting Toggle, #2 Cable
(Specify 10' or 30')
NOTES: (1) Voltage must be specified when ordered with plugs or emergency ballasts.
ballast as UNV (120V-277V), 347V or 480V.
(2) Specify
voltage of
Accessories (order separately)
HBAYC-CHAIN/SET/U=(2) V-Hook Hanger,
36" Chain Sets w/S-Hooks
HB-SPM=Single Monopoint Hanger w/Hub
RH-1=Retrofit Hanger
FH-1=Fixture Hook
=Fixture Loop
Y-TOGGLE=Y Mounting Toggle, #2 Cable
(Specify 10' or 30')
S H I P P I N G DATA
Catalog No.
ABI-454
ABI-554
ABI-654
Specifications and dimensions subject to change without notice.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801
Wt.
25 lbs.
25 lbs.
27 lbs.
ADF071257
2012-01-31 13:20:58
Download