fAIL-SAfE

advertisement
fAIL-sAFE
D es c r iption
The 2HBHD is designed for use in high mounting height applications
where periodic cleaning with high pressure is required. This surfacemounted luminaire has a hole-free design and is enclosed and gasketed
to protect against infiltration of particles and airborne bacteria. The
sealed housing and door frame allow relamping without contamination
of the clean areas. These luminaires are UL/cUL listed for wet locations.
2HBHD's high lumen package allows the benefits of fluorescent to be
applied at high mounting heights that were traditionally exclusive to HID.
®
Type
Catalog #
Project
Date
Comments
Prepared by
S pec if ic a tion Feat u r e s
App l i c a t i o n s
F i ni s h
Op tics
Applications include clean rooms,
technical and bio- medical labs,
food processing/testing centers
and pharmaceutical labs.
The primary benefits include
exceptional color rendering,
high system efficacy, 95%
lumen maintenance, long lamp
life, instant on/instant re-strike,
economical dimming, and uniform
brightness control.
High gloss, electrostatically
applied, white powder coat finish,
average minimum reflectance 92%.
1000 hour salt spray test.
Die formed reflectors are faceted
for 4 and 6 lamp configurations
with two optical distributions:
medium and wide. Medium
beam optics utilizes 95%
specular substrate while the
wide distribution utilizes a high
performance 95% reflective
polyester powder coated finish.
Fas t e n e r s , D o o r
Flush mounted, stainless steel
machine screws secure through
captive cage nuts in housing that
evenly compress gasketing on all
sides.
Housing
Die-formed, CRS housing with
seam welded and sealed end
caps. Contains no exposed holes
that would allow air or moisture
passage.
D oor/Shi e l di ng
One-piece, 18 ga., fully gasketed,
outside door with die-formed and
beveled edges eliminates seams
which could entrap microscopic
contaminants. Two braided,
stainless steel cables on one side
of door provide hinging.
Lens R etention and Gask et
A gasketed access plate on top of
the housing with two 7/8" diameter
knockouts allows connection
of vapor tight conduit fitting.
Mounting Standard surface mount
with gasket between surface and
fixture housing.
Unique, Particulock(TM) lens
retention system utilizes
continuous, 18 ga. clampdowns
to sandwich gasketing between
lens and door frame. Closed cell,
one-piece gasketing surrounds
perimeter of lens to seal lens and
door for an even environmental
seal to the housing. Another layer
seals fixture to ceiling system after
installation.
L e ns
B allast
One-piece, clear extruded lens with
internal prism pattern. Choice of
prismatic acrylic or clear acrylic.
Electronic, Class P, CBM/ETL
ballast.
Access
2HBHD
Fluorescent
Specialty: Fluorescent High-Bay
Surface Mount
4 or 6 Lamps
IP65 Rated
Labels
UL/cUL listed for wet locations
under covered ceiling. IP65 rated.
4-1/2"
[115mm]
Energy Data
Input Watts:
EB Ballasts
432 = 109W
632 = 167W
23-11/16" [602mm]
EB/Plus Ballasts
432 = 147W
632 = 221W
SURFACE MOUNT
L am p C onf igur a ti o n s
M o unt ing D ime nsions
4-lamp
(4) 3/8" [10mm] Dia.
Mounting Hole
4-1/2"
[115mm]
12"
[305mm]
5"
5"
5"
[127mm] [127mm] [127mm]
23 11/16"
10 3/16" [602mm]
[259mm]
23-11/16" [602mm]
6-lamp
4-1/2"
[115mm]
X=3-1/2"
[89mm]
X
X
X
X
X
(2) 7/8" [22mm] KO
Gasketed Access Plate
36"
[914mm]
48"
[1219mm]
1 1/2"
[38mm]
D oor F ra me
ER Ballasts
432 = 112W
632 = 169W
ER/Plus Ballasts
432 = 144W
632 = 218W
Luminaire Efficacy Rating
LER = 75
Catalog Number: 2HBHD-632-CL
Yearly Cost of 1000 Lumens,
3000 hrs. at .08 KWH = $3.22
* Reference the lamp/ballast data in the
Technical Section for specific lamp/
ballast
requirements
** Consult Pre Sales Technical Support.
23-11/16" [602mm]
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADC100538
2012-10-22 15:16:39
2HBHD
Order ing I nf or m a tion
S A M P L E N U M B E R : 2 H B H D - 6 5 4 T 5 - A- U N V- E B T 2
Width
2=24"
Shielding
A=Prismatic Acrylic Lens &
Aluminum Doorframe
CL=Clear Acrylic Lens &
Aluminum Doorframe
Series
HBHD=High Bay
Hose Down
Voltage (1)
UNV=Universal 120/277 Voltage
UNC=Universal
347/480 Voltage (T5 linear only) (2)
120V=120 Volt
277V=277 Volt
347V=347 Volt
No. of Lamps
4=4 Lamps
6=6 Lamps
Lamp Type
32=32W T8 Lamps (48")
28T5=28W T5 Lamps (48")
54T5=54W T5HO Lamps (48")
Options
Lamps Installed
L8830=T8 Lamp, 80CRI 3000K
L8835=T8 Lamp, 80CRI 3500K
L8841=T8 Lamp, 80CRI 4100K
L8850=T8 Lamp, 80CRI 5000K
L5830=T5 Lamp, 80CRI 3000K
L5835=T5 Lamp, 80CRI 3500K
L5841=T5 Lamp, 80CRI 4100K
L5850=T5 Lamp, 80CRI 5000K
GL=Single Element Fuse
GM=Double Element Fuse
EL4=EM Pack, T8, Biax
EL5=EM Pack, T5, T5HO
Distribution
Blank=Medium (Specular Aluminum)
G=Wide (High Reflectance White)
(1)
NOTES: Voltage must be specified when ordered with plugs, motion or emergency ballasts.
ballast configuration in EB8/PLUS only for T8 UNC version.
(2)
Packaging
Options
C3=3' Power Cord
U=Unit Pack
C6=6' Power Cord
PAL=Pallet Pack
PC3-=3' Power Cord & Plug PALC=Job Pack
(Specify Voltage) (1)
In Carton
PC6-=6' Power Cord & Plug
(Specify Voltage) (1)
SSN=Stainless Steel Door,
Brushed Finish
SHN=Stainless Steel Housing,
Brushed Finish
SSP=Stainless Steel Door,
Painted White
SHP=Stainless Steel Housing,
Painted White
Ballast Type (1)
T8 Systems
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
No. of Ballast
1 or 2
EB8 /PLUS= T8 Electronic Instant Start. (2)
High Ballast Factor >1.13.
No. of
Total Harmonic Distortion < 20%
Ballast
1 or 2
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast
1 or 2
ER8 /PLUS= T8 Electronic Program Start.
High Ballast Factor >1.13.
No. of
Total Harmonic Distortion < 10%
Ballast
1 or 2
T5 Systems
EBT =T5 Linear Electronic Program Rapid
Start Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
EHT =T5 Linear Electronic Start High Ambient.(2)
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
DIM=Dimming (ballast must be specified)
2 lamp ballast configurations only for T5 UNC version. 2/3 lamp
Ph otom etr ic s
2HBHD-632-CL
(2) Electronic Ballasts
(6) F32T8/TL835
lamps
3000 lumens
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 1.2 x
mounting height
Efficiency 68.1%
Test Report:
2HBHD632CL.IES
LER =75
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.22
o
Along II
4538
4601
4787
4969
4999
4938
4514
3882
3100
2696
2392
2169
2008
1762
1400
875
355
77
0
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
45
4538
4543
4628
4705
4740
4685
4559
4262
3739
3118
2414
1992
1643
1377
1131
772
360
76
0
Across
4538
4510
4442
4319
4160
3958
3711
3434
3121
2782
2420
2035
1638
1235
843
485
211
48
0
C o e f fi c i e n t s o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity r eflectance
80%
70%
70 50 30 10
70 50 30 10
81
75
68
62
57
53
49
45
42
40
37
81
72
63
56
49
44
40
36
33
31
28
81
69
58
50
44
38
34
31
28
25
23
81
66
55
46
39
34
30
27
24
21
19
79
73
66
61
56
51
48
44
41
39
36
79
70
62
54
49
44
39
36
33
30
28
79 79
68 65
58 54
50 46
43 39
38 34
34 30
30 26
27 24
25 21
23 19
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
0-180
Lumens
3768
6124
10121
12258
12258
%Lamp
20.9
34.0
56.2
68.1
68.1
90
45o
8058
8229
8222
8038
7410
6624
5867
4902
3736
2770
2164
1806
1671
1388
1043
734
394
84
0
0
Across
8058
8014
7894
7681
7382
7000
6542
6018
5440
4810
4141
3435
2715
1998
1309
707
270
48
0
C o e f fi c i e n t s o f U t i l i z a t i o n
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
76
67
59
52
47
42
38
35
32
29
27
72
65
57
51
45
41
37
34
31
29
27
69
62
55
49
44
40
36
33
30
28
26
68
58
49
42
36
31
28
25
22
20
18
76
65
56
48
42
37
33
30
27
25
23
76
63
53
45
38
34
30
26
24
21
19
72
63
54
47
41
37
33
29
27
24
22
72
61
52
44
38
33
29
26
23
21
19
69
61
53
46
40
36
32
29
26
24
22
69
60
51
43
37
33
29
26
23
21
19
Ty p i c a l VC P Pe r c e n t a g e s
%Fixture
30.7
50.0
82.6
91.5
100.0
Candela
2HBHD-654T5-CL
(3) Electronic Ballasts
Angle
Along II
(6) F54T5/841HO
0
8058
54W lamps
5
8298
4400 lumens
10
8281
15
7647
Spacing criterion:
20
6853
(II) 1.0 x mounting
25
5872
height, ( ) 1.2 x
30
4611
mounting height
35
3428
40
2751
Efficiency 52.9%
45
2431
Test Report:
50
2365
55
2227
2HBHD654CL.IES
60
1957
LER =40
65
1577
1358
Yearly Cost of 1000 70
918
lumens, 3000 hrs at 75
80
416
.08 KWH = $6.03
85
87
Candela
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Height Along
8.5'
10.0'
35
43
33
34
35
33
39
39
40
36
Height Across
8.5'
10.0'
41
46
39
40
40
39
43
42
43
40
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity r eflectance
80%
70%
70 50 30 10
70 50 30 10
70
65
60
55
51
47
44
41
38
36
34
70
63
56
50
45
40
37
34
31
29
27
70
61
52
45
40
36
32
29
26
24
22
70
59
49
42
36
32
28
26
23
21
19
69
64
59
54
50
46
43
40
38
35
33
69
61
55
49
44
40
36
33
31
28
26
69 69
59 58
51 49
45 42
40 36
35 32
32 28
29 25
26 23
24 21
22 19
20%
50%
50 30 10
30%
50 30 10
50
66
59
53
47
42
39
35
32
30
28
26
63
57
51
46
41
37
34
32
29
27
25
60
55
49
44
40
36
33
31
29
27
25
66
57
50
44
39
35
31
28
26
24
22
66
56
47
41
36
31
28
25
23
21
19
63
55
48
43
38
34
31
28
26
23
22
63
54
46
40
35
31
28
25
23
21
19
Zonal Lumen Summary
Ty p i c a l VC P Pe r c e n t a g e s
Zone
0-30
0-40
0-60
0-90
0-180
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Lumens
5876
8802
13385
15627
15627
%Lamp
22.3
33.3
50.7
59.2
59.2
%Fixture
37.6
56.3
85.7
75.3
100.0
Specifications and dimensions subject to change without notice.
Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
Height Along
8.5'
10.0'
37
44
34
35
35
33
40
39
40
36
10%
30 10
60
54
47
42
37
33
30
27
25
23
21
60
53
45
40
35
31
28
25
23
21
19
0%
0
59
51
44
38
34
30
27
24
22
20
18
Height Across
8.5'
10.0'
39
42
37
37
39
37
42
40
42
39
ADC100538
2012-10-22 15:16:39
Download