COOPER LIGHTING - SURE-LITES ® DESCRIPTION The Sure-Lites Lifeway II Three Phase represents the highest performance in uninterruptible technology while the transistorized inverter is providing power protection. Ready for virtually any emergency with this stand by power system. This pulse width modulated inverter has 2 millisecond transfer time. The AC in to AC out operating efficiency is typically 98%, well above a typical fast transfer inverter. The internal construction of each cabinet consists of an AC to DC battery charger, DC to AC inverter. Type Catalog # Project Date Comments Prepared by S P E C I F I C AT I O N F E AT U R E S E l e c t ri c a l H o u s i n g C o n s t ru c t i o n Wa rra n t y - Choice of 120/208 VAC or 277/480 VAC, 60 Hz; other voltages available, consult Cooper Lighting Representative - Available from 4.8 to 50 kVA - Three Phase, WYE or DELTA configurations - 98% efficiency - PWM/GBT Technology - 115% overload capacity - Sine wave output - 80db transverse mode noise attenuation - 120db common mode noise attenuation - Input circuit breaker - Battery circuit breaker on 24kVA and up - Sealed lead calcium batteries standard - Output distortion <3%THD Linear Load - Solid-State - Self Testing and SelfDiagnostic with Event, Test and Alarm Logs (includes 5 minute monthly test and 90 minute annual test) - RS-232 Communication - Supports LED and HID Lighting - Formed Steel Cabinet and Doors are Finished in a Durable Powder - Front Access Doors Allow Easy Entry for Servicing - Acoustically Quiet - Limited Manufacturer's One (1) Year Warranty On All Electronics* - Limited Manufacturer's Two (2) Year Warranty On All Electronics with Start-Up Service* - Limited Manufacturer's Battery Warranty: One (1) Year Full Value Warranty/9 Years Pro Rata M o d e ls C3FT004 thru 016 C3FT024 thru 050 C3FT024 thru 050** Code Compliance - UL 924 Listed Application - HID, Fluorescent and Incandescent Lighting - Electronic Equipment - Manufacturing Equipment LIFEWAY II THREE PHASE SERIES 4 . 8 - 5 0 K VA HID F L U O R E S C E NT I N C A N D E S C E NT A H e i g ht W i d th D e p th A 47" 72" 72” B 30" 44" 48” C 25" 31" 31” B Three Phase, UPS * Additional Warranty Details Upon Request **Battery Cabinets ORDERING INFORMATION Series C3FT=Three Phase KVA Rating 004=4.8 Voltage Input Voltage Output 120 120 006=6.0 008=8.0 277 010=10.0 012=12.5 Notes: * C 277 O ff i c e B u i l d i n g s Industrial Complexes Military Complexes S p o rt s C o m p l e x e s Pr i s o n s Ra i l wa y Tr a n s i t A i r p o rt s L a r g e 9 11 I n s t a l l a t i o n s Hospitals Colleges See Optional Features on back. 016=16.7 024=24.0 033=33.0 040=40.0 050=50.0 Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADX052054 pc 2010-08-19 16:59:52 LIFEWAY II THREE PHASE SERIES S P E C I F I C AT I O N DATA Input: Voltage Input Power Walk-In Input Frequency Synchronizing Slew Rate Protection Harmonic Distortion Power Factor 120/208 or 277/480VAC 3-phase 4-wire +1-% - 15%. (Wye configuration) Limiting inrush current to less than 125%, 10 times for 1 line cycle 60Hz, +/-3%, 50Hz available upon request 1Hz per second nominal Input Circuit Breaker <10% .5 lag/lead Output: Voltage Static Voltage Dynamic Voltage Harmonic Distortion Output Frequency Load Power Factor Inverter Overload Protection 120/208 or 277/480VAC 3-phase 4-wire. (Wye or Delta configuration) Load current change +/-4%, battery discharge +/-4% +/-3% for +/-25% load step change, +/-6% for a 50% load step change, recovery within 3 cycles <3% THD for linear load 60Hz +/- .05Hz during emergency mode .5 lag to .5 lead 115% for 5 minutes Output Circuit Breaker (optional) Battery: Type Charger Protection Disconnect Optional Runtimes Valve-regulated sealed lead calcium. Contact factory for additional battery types. Microprocessor controlled for various battery types and temperature compensating (recharge per UL924 spec) Automatic low-battery disconnect; automatic restart upon utility return. Fuse-and-Fuse/Circuit Breaker above 24KVA Extended runtimes available. Consult factory for additional information Environmental: Altitude Operating Temperature Storage Temperature Relative Humidity <10,000 feet (above sea level) without derating 20 to 30 degrees Celsius -20 to 70 degrees Celsius (electronics only) <95% (non-condensing) General: Design Generator Input Control Input Standy-by UPS. PWM inverter type utilizing IGBT technology with 2ms transfer time. Compatible with generators Microprocessor controlled 2 x 20-character display with touch pad controls & functions 5 LED indicators & alarm with ring-back feature Input & Output Voltage, Battery Voltage, Battery & Output Current, Output VA, Temperature, Inverter Wattage High/Low Battery Charger Fault, Near Low Battery, Low Battery, Load Reduction Fault, Output Overload, High/Low AC Input Volts, High Ambient Temperature, Inverter Fault, Output Fault, Optional Circuit Breaker Trip Metering Alarms Communications Manual Maintenance Bypass Alarm Contacts RS-232 port (DB9) Programmable monthly and yearly testing (meets NFPA 101 Life Safety Code requirements) Standard Optional Summary Form “C” Contacts Auto Dialer, Battery Charger Upgrade, Dimming Bypass Relay, Extended Factory Warranty, External Maintenance Bypass Switch (MBYP), Factory Startup and Training, Fax/Modem, Output Circuit Breakers (OCB), Output Trip Alarms, Remote Meter Panel, Remote Summary Alarm Panel, Seismic Mounting, Summary Alarm Dry Contact, Summary Form C Contacts, and Variable Time Delay. Optional Features: Physical: Cabinet Cooling Cable Entry Access Freestanding NEMA Type 1 Forced Air during emergency mode Top and side on 4.8KVA - 16.7KVA; side only on 24KVA - 50KVA Front UPS Electronics Module Part # C3FT004 4.8 C3FT006 6.0 C3FT008 8.0 C3FT010 10.0 C3FT012 12.5 C3FT016 16.7 C3FT024 24.0 C3FT033 33.0 C3FT040 40.0 C3FT050 50.0 Batteries Power Rating (kVA) Power Rating (kW) Efficiency (@ full load) Audible Noise (dBA @ 1m)1 Heat Loss (BTU) Cabinet Dimensions 4.8 6.0 8.0 10.0 12.5 16.7 24.0 33.0 40.0 50.0 97 97 97 97 97 97 97 97 97 97 45 45 45 45 45 45 45 45 45 45 326 408 544 680 850 1136 1632 2244 2720 3400 Battery Module Voltage (VDC) Current (Amperes) Run Time (mins) Cabinet Dimensions Number of Batteries Width Height Depth Weight in/cm in/cm in/cm lbs / k g 30/77 30/77 30/77 30/77 30/77 30/77 44/112 44/112 44/112 44/112 47/120 47/120 47/120 47/120 47/120 47/120 72/183 72/183 72/183 72/183 25/64 25/64 25/64 25/64 25/64 25/64 31/79 31/79 31/79 31/79 535/243 535/243 535/243 639/290 639/290 639/290 1250/567 1230/567 1450/658 1450/658 B attery Total Weight lbs / k g 888/403 1110/504 1480/672 1776/806 2220/1007 2960/1343 4440/2014 6080/2758 7400/3357 9120/4137 12 15 20 24 30 40 60 40 100 60 144 180 240 144 180 240 240 240 240 240 39 39 39 81 81 81 117 160 194 90 90 90 90 90 90 90 90 90 243 90 Number of Battery Cabinets Width Height Depth in/cm in/cm in/cm Weight lbs / k g 30/77 30/77 30/77 30/77 30/77 30/77 48/122 48/122 48/122 48/122 47/120 47/120 47/120 47/120 47/120 47/120 72/183 72/183 72/183 72/183 25/64 25/64 25/64 25/64 25/64 25/64 31/79 31/79 31/79 31/79 210/96 210/96 230/106 420/191 420/191 464/211 700/318 1300/590 1300/590 1400/635 Tot. Sys. Wt. 1 1 1 2 2 2 1 2 2 2 1633/741 1855/842 2247/1020 2835/1286 3279/1488 4063/1843 6390/2899 8630/3915 10150/4604 11980/5434 Specifications and dimensions subject to change without notice. Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADX052054 pc 2010-08-19 16:59:52 2010-08-09 14:08:25