Technical Data Dimmable Electronic Ballast Catalog# Prepared by Project Date Comments Type Overview Fifth Light’s line of DALI ballasts provides continuous dimming control and network connectivity to conserve energy, simplify maintenance and personalize the lighting environment. The dimmable electronic ballasts allow for changes to light levels, program lighting scenes and to detect when a tube needs to be replaced. Features Integrated DALI communication interface (can be run in the same conduit as power lines) Available in 120/277 and 347 VAC Continuous dimming from 100% to 1% for T5, T5HO and T8 based on catalog number shown on this sheet Dimmable Electronic Ballast August 2015 Specifications Catalog # (See ordering chart) Performance Starting Method: Programmed Rapid-Start (Pre-Heat Time = 1.5 seconds) Lamp Connection: Parallel Input Voltage: 120-277 VAC or 347 VAC +/- 10% Input Frequency: 50/60 Hz Lamp Crest Factor: <1.7 Lamp Frequency: >42 kHz THD: <10% Power Factor: >0.98 Ballast Factor: 0.01 - 1.0 Minimum Lamp Starting Temperature: 50o F (10o C) Maximum Case Temperature: 167o F (75o C) Operating Environment: 50°F to 140°F (10°C to 60°C) For indoor use only Sound Rating: Class A Dimensions: 1.18”H x 1.18”W x 18”L (30mm x 30mm x 457.20mm) 120-277 VAC Ballasts: Wire terminal connections, use 18 AWG solid copper only 347 VAC and 3-lamp 120 VAC Ballasts: 18 AWG solid TFN leads provided DALI: Two wire non-polarized control Grounding: Ground terminal must be connected to earth ground with copper wire Mounting: Mount flat to fixture chassis with two screws Communication Interface: Digital Addressable Lighting Interface (DALI) DALI Current Draw: 2mA ANSI StandardC82.11 C62.41 FCC Part 18 for EMI and RFI Wiring & Mounting Control Specification Standards 2 www.eaton.com/lightingsystems Dimensions (Inches/mm) 1.18”H x 1.18”W x 18”L (30mm x 30mm x 457.20mm) 0.2/ 5.1 TOP VIEW 1.18 / 30.0 17.7 / 449.6 SIDE VIEW 1.18 / 30.0 18.0 / 457.2 Dimmable Electronic Ballast August 2015 Wiring NNote: Install in accordance with all applicable national and local electrical & building codes. Specifications subject to change without notice. Ballast must be properly grounded to earth ground. Max length of blue and red wires: 3 ft. Max length of yellow and blue/white wires: 5 ft. 1-Lamp Models 347 VAC Communication Wires (DALI) Purple Fluorescent Lamp Dimmable Electronic Ballast Purple Fluorescent Lamp Fluorescent Lamp Blue Dimmable Electronic Ballast Purple Red Green White Black Communication Wires (DALI) Red Fluorescent Lamp Yellow Purple Blue Communication Wires (DALI) Power Wires Dimmable Electronic Ballast Yellow Green White Black Blue/White 3-Lamp Models 2-Lamp Models Power Wires Green White Black Red Communication Wires (DALI) Power Wires Dimmable Electronic Ballast Red Green White Black Blue Power Wires Yellow 120/277 VAC Fluorescent Lamp Sample System Topology DALI COMMUNICATION BUS Scene 1 Maximum of up to 64 devices on each DALI Bus. All devices must be within 900 feet of the Lighting Control Panel (LCP). 16/2 AWG recommended wire. Scene 2 Scene 3 Scene 4 DALI FIELD RELAY DALI DIMMABLE BALLAST 11:46 06/26/09 DALI MULTI SENSOR DALI DAC 0-10 VDC DALI DIMMING MODULE DALI WALLSTATION 1000 FIFTH LIGHT TECHNOLOGY 1 10% 2 10% 20% 3 30% 4 40% DALI RELAY PANEL Units Are: 1027.1028 LIGHTS LIGHTING CONTROL PANEL NETWORK SWITCH GROUPS SCENES SUPPORT VOIP PHONE TOUCH SCREEN MOBILE APP ETHERNET CENTRAL MANAGER www.eaton.com/lightingsystems 3 Dimmable Electronic Ballast August 2015 Ordering Catalog # Lamp Type Lamp Wattage Lamp Length (in feet) Voltage Input Wattage Input Amps Ballast Efficacy Factor* (BEF) Dimming Performance 32 4 120-277 37 120V - 0.31 277V - 0.13 120V - 2.70 277V - 2.78 1% 32 4 347 35 347V - 0.12 347V - 2.86 1% 120V - 5.56 277V - 5.56 1% FLT-120/277-1-32WT8-DALI T8 FLT-347-1-32WT8-DALI 1-Lamp Ballasts FLT-120/277-1-14WT5-DALI 14 2 120-277 18 120V - 0.15 277V - 0.07 28 4 120-277 32 120V - 0.27 277V - 0.11 120V - 3.13 277V - 3.23 1% 21 3 120-277 25 120V - 0.21 277V - 0.09 120V - 4.00 277V - 4.00 1% 54 4 120-277 62 120V - 0.52 277V - 0.22 120V - 1.61 277V - 1.67 1% 24 2 277-347 28 277V - 0.12 347V - 0.10 277V - 3.57 347V - 3.57 5% 39 3 277-347 44 277V - 0.19 347V - 0.15 277V - 2.27 347V - 2.27 5% 54 4 347 60 347V - 0.21 347V - 1.67 5% 32 4 120 68 120v - 0.61 277V - 0.26 120V - 1.37 277V - 1.43 1% 32 4 277 67 120V - 0.61 277V - 0.26 120V - 1.37 277V - 1.43 1% FLT-347-2-32WT8-DALI 32 4 347 70 347V - 0.24 347V - 1.43 1% FLT-120/277-2-14WT5-DALI 14 2 120-277 35 120V - 0.28 277V - 0.13 120V - 2.86 277V - 2.86 1% 28 4 120-277 62 120V - 0.55 277V - 0.23 120V - 1.61 277V - 1.69 1% 21 3 120-277 47 120V - 0.39 277V 0.17 120V - 2.13 277V - 2.17 1% 54 4 120-277 126 120V - 1.05 277V - 0.44 120V - 0.79 277V - 0.83 1% 24 2 277-347 53 277V - 0.23 347V - 0.19 277V - 1.89 347V - 1.89 5% 39 3 277-347 83 277V - 0.35 347V - 0.28 277V - 1.20 347V - 1.20 5% 54 4 347 120 347V - 0.35 347V - 0.83 5% 32 4 347 104 347V - 0.35 347V - 0.96 10% T5 FLT-120/277-1-28WT5HE-DALI FLT-120/277-1-54WT5HODALI FLT-277/347-1-39/24WT5HODALI T5HO FLT-347-1-54WT5HO-DALI 2-Lamp Ballasts FLT-120/277-2-32WT8-DALI T8 T5 FLT-120/277-2-28WT5HE-DALI FLT-120/277-2-54WT5HODALI FLT-277/347-2-24WT5HODALI FLT-277/347-2-39WT5HODALI T5HO 3-Lamp Ballasts FLT-347-2-54WT5HO-DALI FLT-347-3-32WT8-DALI T8 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Lighting systems 203 Cooper Circle Peachtree City, GA 30269 www.eaton.com/lightingsystems © 2015 Eaton All Rights Reserved Printed in USA Publication No. TD503044EN August 17, 2015 Eaton is a registered trademark. All other trademarks are property of their respective owners.