Introduction
Dimensions
3.15 in
(80 mm)
0.26 in
(6.5 mm)
1.73 in
(44 mm)
Welcome
The Ineo wallstation provides sleek appearance combined
with complete control and flexibility. The adaptable design
allows you to choose from a range of button combinations
which can be fitted and changed at any time. Where
fitted, raise and lower buttons compliment the usual
selection buttons to allow immediate changes to the
intensity of any scene.
An optional infrared remote control allows similar
functionality from anywhere within the room via the
detector built into the front panel of the Ineo wallstation.
All control signals are transmitted to the source
controller(s) using iCANnet connections.
Mounting Instructions
Supplied parts
Main Body
Inner Plate
Front Cover
4.84 in
(123 mm)
3.26 in
(83 mm)
0.65 in
(17 mm)
The Ineo wallstation is intended to fit into a single gang
US style wall box with a minimum internal depth of 2
inches (51 mm). Wall boxes available from Eaton’s Cooper
Controls Business.
Mounting Instructions
Disassembling the wallstation
Fixing to a wallbox
1.
The Ineo wallstation is intended to fit into a single gang US
style wall box with a minimum internal depth of 2 inches
(51 mm).
2.
On the underside of the front cover, beneath the lower
buttons, locate the small central recess. Carefully insert
a small implement (such as a pen or screwdriver) into
the recess and lever the front cover gently away from
the inner plate.
With the Ineo wallstation disassembled (see opposite), use
the two supplied long screws to secure the rear chassis
plate to the wall box.
Unclip the front cover from the top of the inner plate.
Control wiring
The Ineo wallstation uses iCANnet connections to ensure
reliable and responsive transfer of control signals between
multiple devices.
Cable connections are made to a removable 5-way
connector block located at the rear of the Ineo wallstation
main body:
3.
Remove the two retaining screws located above and
below the buttons and lift the inner plate away from
the main body.
0V
(black)
Cable type:
4.
2
Store all removed parts safe from damage.
CAN-L
(blue)
DRAIN
(gray)
CAN-H
(white)
+12V
(red)
Eaton’s Cooper LCCNP (Non Plenum)
or Eaton’s Cooper LCCP (Plenum)
or Belden1502R (Non Plenum)
or 1502P (Plenum)
Maximum cable length: 1000m/3200ft without BN-2-NA
Devices per segment: 100 without a BN-2-NA EXPS-15
required if more than 10 devices
are used without Source Controller.
Ineo Wallstation Ineo Wallstation Ineo Wallstation www.eaton.com
Mounting Instructions
Termination
Reassembling the wallstation
The iCANnet link is a ‘daisy chain’ protocol that requires
termination on the devices located at either end of the chain.
1.
Place the inner plate onto the main body (noting the
orientation arrow). With the plate in place, insert and
lightly tighten the two retaining screws.
2.
Attach the top edge of the front cover to the main body.
3.
Angle the front cover down and press the lower part of
it against the inner plate until it clicks into place
Device
T
Device
Device
Universal
Source
Controller
T
The Ineo wallstation is supplied with termination enabled
as standard. If the Ineo wallstation is not connected as an
end device in the chain, you need to disable termination. To
disable termination, move the jumper from the upper two
pins to the lower two pins, as shown here:
Termination ON
Termination OFF
Changing buttons
The Ineo wallstation allows you to change the buttons in
order to customize its appearance.
1. Remove the front cover and inner plate as discussed in
‘Disassembling the wallstation’.
2. Locate the four clips (two
on each side) of the button
frame. Carefully press in
all four clips to disenage
the button frame and pull
the frame away from the
main body.
3. You can now remove the
buttons from the frame
and replace them (and the
frame), as necessary.
4. With the new buttons in
place within the frame,
align its clips with the four
holes of the main body
and press it into place so
Button frame
Main
that all four clips click as
body
with buttons
they lock.
Ambient atmosphere requirements
Temperature
Humidity
32° F to 104° F (0° C to +40° C)
0 to 95% non-condensing
Ineo Wallstation Ineo Wallstation Ineo Wallstation www.eaton.com
3
Ordering
Each model is specified using a part number in the
following format:
CLS - 1 - TLB - RL - W - IR - T1
Standard Text Offerings can be selected by
adding one of the below to the model number
iLumin
Ineo
Color
Number of Buttons
1-3
1-2
1-6
1-4
=
=
=
=
W
B
V
G
Large Buttons
Large Buttons, Raise/Lower/On/Off
Small Buttons
Small Buttons, Raise/Lower/On/Off
Button Size
TLB = Large Buttons
TSB = Small Buttons
=
=
=
=
White
Black
Ivory
Gray
Blank
T1
T2
T3
CE
Raise/Lower/On/Off
Scene 1, Scene 2, etc.
Preset 1, Preset 2, etc.
General, Meeting, Seminar, Lecture
Lunch, Cocktails, Dinner, Special
Custom Engraving (Requires Custom
Engraving form at time of order)
IR Receiver
Blank = No Raise/Lower/On/Off
RL
= Raise/Lower/On/Off
Blank = Not Fitted
IR
= Fitted
*Custom Engraving Form available
at www.coopercontrol.com.
WARRANTIES AND LIMITATION OF LIABILITY
Please refer to www.coopercontrol.com under the Legal
section for our terms and conditions.
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Eaton’s Cooper Controls Business
203 Cooper Circle
Peachtree City, GA 30269
CooperControl.com
© 2014 Eaton
All Rights Reserved
Printed in USA
P/N: 9850-000266-01
Eaton is a registered trademark.
All trademarks are property
of their respective owners.