iLumin Technical Data Power Extender Catalog# Prepared by Project Date Comments Type Overview The PE400-1 Power Extender allows a dimmers power handling capacity to be extended to a full 1000W/VA on 120V input power. It allows a dimmer to dim or switch a fully loaded circuit of electronic low voltage and incandescent loads only. Features Works with electronic low voltage and incandescent Emulates the characteristics of the dimmer that it is connected to in terms of dimming range and resolution Power Extender July 2015 Power Requirements Operating Environment Housing Size Standards Input Voltage: 120V, 50/60 Hz Load rating: 1000W/VA Electronic Low Voltage and Incandescent Loads Only Load Output Power: Phase independent of control device Dimmer Input: 120V, 50/60 Hz Operating Temperature: 0ºC to 40ºC Storage Temperature: -10ºC to 85ºC Relative Humidity: 20%–90%, non-condensing Aluminum clear anodized extruded heat sink with a snap-on molded white cover 4.72"L x 4.5"W x 0.5"H (120mm x 114mm x 12.7mm) UL Listed, CSA Certified and FCC Part 15 Dimensions 4.50 4.72 Specifications 2.80 2.06 2 www.eaton.com/lightingsystems Power Extender Power Extender Power Extender Wallplate July 2015 Mounting Figure 3: Front View Spacing All Power Extenders must have 4-1/2" spacing above and below each unit for proper ventilation and heat dissipation (refer to Figure 3). Line voltage wiring should be at least 6ft away from sound or electronic equipment wiring. Mount Power Extender to wall box with “TOP” facing up as follows: For Wall Box Mounting (refer to Figure 1), for Flush Mounting (refer to Figure 2) and for Panel Mounting (not shown), proceed as follows: 4-1/2" (11.4 cm) Minimum A. The enclosure must be in accordance with all local and national electrical codes. B. Eaton DOES NOT recommend using a door to enclose the front of a panel, since this restricts airflow to the controls. C. If mounting multiple controls in an enclosure: Ambient timperature within an enclosure “MUST REMAIN BETWEEN” 32º-104º F (0º-40º C). If not mounting in a metal enclosure, all units “MUST” be mounted in a wall box. D. To improve heat dissipation of controls, remove the faceplate from the unit. Figure 1: Surface Mounting 1900 Box 2 Gang Raised Cover Raised Cover Mounting Screws (4 Places) 4-1/2" (11.4 cm) Minimum TOP Power Extender Power Extender Wallplate Figure 2: Flush Mounting 1900 Box 2 Gang Raised Cover Raised Cover Mounting Screws (4 Places) TOP Power Extender Power Extender Wallplate Figure 3: Front View Spacing www.eaton.com/lightingsystems 3 INPUT HOT SWITCH HOT LOAD NEUTRAL NEUTRAL Power Extender CONTROL Neutral Line OR Load Line Load Power Extender Green Ground OUTPUT July 2015 LOAD Hot (Black) Line 2 (120VAC) Black ELECTRONIC LOW-VOLTAGE White BALLAST Neutral 2 (White) Wiring Diagrams Wiring Diagram 1: Single Feed Wiring Application Used if Dimmer/Switch has Neutral connection ( ) Hot (Black) Line (120VAC) iLumin Panel (Load) Power Extender Neutral (White) Green Ground INPUT Power Extender OUTPUT LOAD SWITCH HOT HOT CONTROL NEUTRAL NEUTRAL SWITCH HOT HOT LOAD Line Load Load CONTROL Neutral OR NEUTRAL Neutral Line SWITCH HOT LOAD HOT NEUTRAL NEUTRAL CONTROL Dimmer iLumin Panel (Load) (Load) NEUTRAL Hot (Black) (120VAC) Wiring Diagram 3: Dual Feed Wiring Application w/Controller and Two Power Extenders Neutral Line Load Power Extender LOAD Black ELECTRONIC LOW-VOLTAGE BALLAST White Neutral (White) Hot (Black) Line 1 (120VAC) LOAD 1 Black Neutral (White) ELECTRONIC LOW-VOLTAGE BALLAST White Hot (Black) Black LOAD 2 Wiring Diagram 2: Dual Feed Wiring Application Used if Dimmer/Switch has Neutral connection ( Hot (Black) Line 1 (120VAC) Line 2 (120VAC) Neutral (White) ELECTRONIC LOW-VOLTAGE BALLAST White ) iLumin Panel (Load) Neutral 1 (White) INPUT HOT Neutral Line SWITCH HOT LOAD NEUTRAL NEUTRAL Power Extender CONTROL Dimmer Neutral OR Load Line Load Green Ground OUTPUT LOAD Hot (Black) Line 2 (120VAC) Black ELECTRONIC LOW-VOLTAGE White BALLAST Neutral 2 (White) Wiring Diagram 3: Dual Feed Wiring Application w/Controller and Two Power Extenders Ordering Hot (Black) Line (120VAC) Catalog # Description (Load) LOAD SWITCH HOT HOT CONTROL SWITCH HOT HOT CONTROL NEUTRAL LOAD NEUTRAL Power Extender NEUTRAL Power Extender Neutral (White) NEUTRAL PE400-1 iLumin Panel (Load) Neutral Line Load Power Extender LOAD 1 Hot (Black) Line 1 (120VAC) Black Neutral (White) ELECTRONIC LOW-VOLTAGE BALLAST White Hot (Black) Black LOAD 2 ELECTRONIC LOW-VOLTAGE BALLAST White Line 2 (120VAC) Neutral (White) Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Lighting systems – Controls products 203 Cooper Circle Peachtree City, GA 30269 www.eaton.com/lightingsystems © 2015 Eaton All Rights Reserved Printed in USA Publication No. TD503018EN July 2, 2015 Eaton is a registered trademark. All other trademarks are property of their respective owners. In cooperation with Leviton Mfg. Co., Inc.