COOPER LIGHTING - METALUX

advertisement
COOPER LIGHTING - METALUX
DESCRIPTION
Type
Catalog #
The floating appearance of the Softside Cloud complements any
décor with a non-glaring illumination. The low profile of the
frameless diffuser allows the fixture to blend in with it’s surroundings.
The Softside Cloud is an ideal choice for a variety of commercial
applications.
®
Project
Date
Comments
Prepared by
S P E C I F I C AT I O N F E AT U R E S
A…Construction
C…Finish
D…Shielding
Housing is manufactured with
die formed cold rolled steel.
Ends are formed for added
strength. Ballast cover is
removable without tools.
Multistage pre-paint ensures
maximum bonding and rust
prevention.
Utilizes a trademark Tuff’R’Puff
commercial grade acrylic lens
that is formulated to protect
against lens breakage and
‘yellowing’ discoloration.
Snap fit for ease of service
and relamping.
B…Electrical*
Universal Instant Start
Commercial Grade Ballast.
CBM/ETL Class “P” Listed.
UL/cUL listed. Rotor lock lampholders. Suitable for damp
locations.
C
A
B
WSC SERIES
232
432
D
10-1/2"
[265mm]
4-7/8"
[123mm]
1 ' x 4 ' , 1- 1 / 2 ' x 4 '
2 or 4 T8 Lamps
14-7/8"
[378mm]
L A M P C O N F I G U R AT I O N S
Modular Fluorescent
Softside Cloud
LENS
2 LAMP
4 LAMP
4-5/8"
[118mm]
4-7/8"
[123mm]
4 Lamp
14-7/8"
[378mm]
4-5/8"
[117mm]
4-5/8"
[117mm]
11-1/4" [286mm]
9" [229mm]
2 Lamp
11-1/4"
[286mm]
14-7/8" [378mm]
51-1/2" [1308mm]
M O U N T I N G D ATA
1-1/2 x 4'
44-1/2" [1131mm]
42-15/16" [1090mm]
1-13/16"
[46mm]
Ceiling Stand-Off
Embossments
Ground Screw Bump
E N E R G Y D ATA
Input Watts:
EB Ballast & STD Lamps
232 (54)
432 (110)
12"
[305mm]
1-1/8"
[29mm]
7/8" [22mm] K.O. (5)
40-7/16" [1027mm]
3"
[76mm]
4-1/2"
[114mm]
42-7/16" [1078mm]
48" [1219mm]
Luminaire Efficacy Rating
LER = FL64
Catalog Number: WSC-232
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $3.28
1' x 4'
1-13/16"
[46mm]
44-1/2" [1131mm]
42-15/16" [1090mm]
Ceiling Stand-Off
Ground Screw Bump
Embossments
7-5/8"
[194mm] 6"
[152mm]
1-1/8"
[29mm]
3"
[76mm]
4-1/2"
[114mm]
40-7/16" [1027mm]
7/8" [22mm] K.O. (5)
42-7/16" [1078mm]
**Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
48" [1219mm]
COOPER LIGHTING
ADF091545
WSC232
P H OTO M E T R I C S
WSC-232
Electronic Ballast
(2) F32T8 Lamps
2800 Lumens each
Spacing criterion:
(II) 1.3 x mounting
height, (⊥) 1.3 x
mounting height
Efficiency 70.5%
Test Report:
P20017
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
LER = FL64
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.28
Along II
812
811
802
787
764
735
700
658
611
559
501
440
375
308
240
174
111
58
22
Across ⊥
812
809
804
794
778
756
730
700
665
628
587
545
504
464
425
387
352
320
290
45°
812
811
804
791
772
747
717
682
642
598
551
501
449
399
350
306
265
229
199
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
79
67
58
50
44
39
35
32
29
26
24
79
63
52
44
38
33
29
25
23
20
19
79
60
48
39
33
28
24
21
19
17
15
75
67
60
55
50
46
42
39
36
34
31
75
63
55
48
42
37
33
30
27
25
23
75
60
50
42
36
31
27
24
22
20
18
75
58
46
38
32
27
23
20
18
16
14
50%
50 30 10
30%
50 30 10
50
68
57
49
43
38
34
30
27
25
23
21
61
51
44
38
34
30
27
25
23
21
19
55
46
39
34
30
27
25
22
20
19
17
68
55
45
38
33
29
25
22
20
18
17
68
52
42
35
29
25
22
19
17
15
13
61
49
41
35
30
26
23
21
19
17
15
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
%Lamp
11.5
19.1
35.3
51.9
70.5
LER = FL55
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.83
20%
Zonal Lumen Summary
Lumens
645
1071
1976
2908
3947
Candlepower
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
1544
1542
1525
1496
1453
1399
1333
1254
1166
1069
962
848
728
604
479
355
238
134
61
Across ⊥
1544
1543
1531
1510
1475
1429
1373
1309
1237
1159
1075
988
898
807
715
626
544
473
416
45°
1544
1541
1528
1502
1465
1415
1355
1286
1207
1121
1028
929
828
725
624
526
435
358
299
Coefficients of Utilization
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
79
71
64
58
53
48
44
41
38
36
33
WSC-432
Electronic Ballast
(2) F32T8 Lamps
2800 Lumens each
Spacing criterion:
(II) 1.3 x mounting
height, (⊥) 1.3 x
mounting height
Efficiency 61.6%
Test Report:
P20021
Candlepower
%Fixture
16.3
27.1
50.1
73.7
100.0
Average
0-Deg
cd/sm
1885
1769
1593
1317
867
61
47
38
32
27
23
20
18
16
14
13
10%
30 10
55
44
37
31
27
24
21
19
17
15
14
Average
45-Deg
cd/sm
1769
1687
1617
1619
1825
0%
0
55
43
35
29
24
21
18
16
14
13
12
52
40
32
27
22
19
16
14
13
11
10
Average
90-Deg
cd/sm
1654
1579
1547
1575
1738
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
70
63
57
51
47
43
39
36
34
32
30
70
59
51
44
39
35
31
28
26
23
21
70
56
46
39
34
29
26
23
20
18
17
70
54
43
35
29
25
22
19
17
15
13
67
59
54
48
44
41
37
35
32
30
28
67
56
49
42
37
33
30
27
25
22
21
67
54
45
38
32
28
25
22
20
18
16
67
51
41
34
28
24
21
18
16
14
13
20%
50%
50 30 10
30%
50 30 10
50
61
51
44
39
34
30
27
25
23
21
19
55
46
40
35
31
28
25
23
21
19
18
50
42
36
32
28
25
23
21
19
17
16
61
49
41
35
30
26
23
20
18
17
15
61
47
38
31
26
23
20
17
15
14
12
55
45
37
32
27
24
21
19
17
15
14
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
1225
2029
3719
5334
6902
%Lamp
10.9
18.1
33.2
47.6
61.6
%Fixture
17.7
29.4
53.9
77.3
100.0
Average
0-Deg
cd/sm
2789
2636
2414
2075
1543
55
43
35
29
25
21
18
16
14
13
12
10%
30 10
50
41
34
29
25
22
20
18
16
14
13
Average
45-Deg
cd/sm
2664
2545
2431
2366
2564
50
40
32
27
23
20
17
15
13
12
11
0%
0
48
37
30
25
21
18
16
14
12
11
10
Average
90-Deg
cd/sm
2529
2419
2331
2289
2458
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : W S C - 2 3 2 - D - W- U N V- E B 8 1- U
Series
WSC=Softside
Cloud
Number
of Lamps
2=2 Lamps (Not Included)
4=4 Lamps (Not Included)
Wattage (Length)
32=32W T8 (48")
Diffuser/Lens
D=Dropped
Frame Finish
W=White
Voltage (1)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal Voltage 120-277 (2)
Options
GL=Single Element Fuse
GM=Double Element Fuse
EL=Emergency Installed (3)
(1)
NOTES: Products also available in non-US voltages and frequencies for international markets. 120V must be
(2)
specified with a residential ballast. Not available when specifying emergencies, voltage must be specific.
(3)
A low profile battery pack is required for installation with standard ballast cover (consult Cooper Lighting).
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject
to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
Packaging
Ballast Type (1)
U=Unit Pack
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
No. of Ballast
1 or 2
EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13.
Total Harmonic Distortion < 10%
No. of
Ballast 1 or 2
ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%
No. of Ballast
1 or 2
ER8 /PLUS=T8 Electronic Program Start. High Ballast Factor >1.13
Total Harmonic Distortion < 10%
No. of
Ballast 1 or 2
HPT8 Ballast
HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77
HB8 =T8 Electronic Instant Start. Ballast Factor .88
HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2
HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88
HR8 L=T8 Electronic Program Start. Low Ballast Factor .77
HR8 =T8 Electronic Program Start. Ballast Factor .88
HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2
S H I P P I N G I N F O R M AT I O N
Catalog No.
Wt.
WSC-232
WSC-432
13 lbs.
17 lbs.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
10/09
ADF091545
Download