Catalog # Type

advertisement
COOPER LIGHTING - METALUX
DESCRIPTION
The SNF Series is a functional and multi-purpose narrow strip family that
incorporates premium performance and construction durability. Designed
with our easy-to-use Flip-Up socket design, the SNF significantly reduces
installation time. The performance and application versatility of this series
can be increased by incorporating symmetrical or asymmetrical reflectors.
The SNF Series can be installed using various mounting methods and
numerous options and accessories are available. The small size of the SNF
makes it an ideal choice for size-restricted architectural applications. The
SNF Series can be the illumination solution in commercial, industrial, retail
and residential applications. Fixtures can be used in storage/utility areas,
®
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
DESCRIPTION (Cont'd)
coves, display cases, shops, task
and general area lighting.
B ... Electrical*
Ballasts are CBM/ETL Class "P" and
are positively secured by mounting
bolts. Rotor Lock lampholders.
UL/CUL listed. Suitable for damp
locations.
A ... Construction
Channel is die formed cold-rolled
steel with numerous KOs for ease
of installation. Groove for Tong
Hanger. End plate quickly converts
to snap-in channel connector for
continuous row alignment. Lamp
holder bracket flips in place.
Channel/wireway cover secured
with quarter-turn fasteners.
D ... Channel/Wireway Cover
Die formed heavy gauge steel.
Tight fit for ease of maintenance.
Easily removed without use of
tools. Optional reflector available
incorporating silver technology
enhancements (Silver Lining).
Consult Pre Sales Technical
Support.
C ... Finish
Multistage iron phosphate
pretreatment ensures maximum
bonding and rust inhibitor.
Lighting upgrade, baked white
enamel finish. Prepainted material
is standard, PAF optional.
A
B
C
SNF
114T5
124T5
128T5
154T5
214T5
224T5
228T5
254T5
D
(T5) 3-3/16"
[81mm]
2-3/4"
[70mm]
2' or 4' STRIP
1 OR 2 T5 OR T5HO LAMPS
Narrow Striplite
MOUNTING DATA
2'
Y
2-11/16" [68mm]
Y=5"
[127mm]
Y
1 LAMP
Ceiling Stand-Off Embossments
Ground Screw
7/8" [22mm]
K.O. (2)
9/16"
X
[15mm]
22-3/8" [568mm]
Y=5"
[127mm]
4'
LAMP CONFIGURATIONS
Ceiling Stand-Off
Embossments
(T5)
3-3/16"
[81mm]
X=3-1/2"
[89mm]
Input Watts:
Electronic Ballast & STD Lamps
(T5) 3-3/16"
[81mm]
2-3/4"
[70mm]
Z
E N E R G Y D ATA
2 LAMP
7/8" [22mm] K.O.
Hole for Toggle
Ground Screw
X
2-3/4"
[70mm]
X=1/4"
[7mm]
8'
Y=5"
[127mm]
X
Y
7/8" [22mm] K.O. (3)
2" [51mm] K.O.
46" [1169mm]
Ceiling Stand-Off
Embossments
11/16" [17mm]
K.O. (2)
Luminaire Efficacy Rating
LER = FS-75
Catalog Number: SNF-228T5
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $3.20
2-11/16" [68mm]
X=2-1/2"
[64mm]
Z=3-1/2"
[89mm]
114 (19), 214 (38), 124 (25), 224 (52),
128 (34), 228 (68), 154 (54), 254 (106)
7/8" [22mm]
K.O. (3)
Ground Screw
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
7/8" [22mm] K.O.
Hole for Toggle
1
One lamp only.
2-11/16" [68mm]
15-3/16" [386mm]
24-1/2" [622mm]
2" [51mm] K.O.
92" [2338mm]
3-1/2"
[89mm]
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADF081659
05/18/2009 6:48:12 PM
PHOTOMETRICS
.
SNF T5
SNF-128T5-UNV-EBT1 C a n d l e p o w e r
Electronic Ballast
F28T5/835 Lamps
2600 Lumens
Spacing criterion:
(II) 1.3 x mounting
height, ( ) 1.5 x
mounting height
Efficiency 100.9%
Test Report: 122P110
LER = FS-75
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.20
Along II
484
489
485
477
463
444
420
392
361
326
290
251
211
170
129
88
51
20
1
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
SNF-154T5-UNV-EBT1 C a n d l e p o w e r
Electronic Ballast
45°
484
487
488
485
478
468
455
438
418
395
374
352
333
314
296
272
242
221
206
Across
484
485
490
491
491
487
480
469
460
450
442
435
428
418
400
375
355
339
323
F54T5/835 Lamps
4400 Lumens
Spacing criterion:
(II) 1.3 x mounting
height, ( ) 1.5 x
mounting height
Efficiency 94.6%
Test Report: 122P112
LER = FS-67
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.51
C o e f fi c i e n t s o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
115
95
81
70
61
54
48
44
40
36
33
115
89
73
61
52
44
39
34
31
28
25
115
84
66
53
44
37
32
28
25
22
20
110
96
86
77
70
64
59
55
51
48
45
110
91
77
67
58
52
46
42
38
35
32
110
86
70
58
50
43
38
33
30
27
24
110
81
63
51
43
36
31
27
24
21
19
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Lumens
400
672
1289
2080
545
2624
%Lamp
15.4
25.8
49.6
80.0
20.9
100.9
45°
764
770
772
767
756
740
721
694
661
626
593
560
530
500
471
434
386
353
328
Across
764
767
774
776
776
771
757
739
725
711
699
686
673
659
631
591
557
532
507
C o e f fi c i e n t s o f U t i l i z a t i o n
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
115
101
91
82
74
68
63
58
54
50
47
Along II
764
768
763
750
728
698
662
619
570
517
461
403
342
280
216
152
90
34
1
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
100
82
70
61
53
47
42
38
35
32
30
92
75
63
55
48
43
39
35
32
29
27
84
68
57
50
44
39
35
32
29
27
25
80
59
47
38
31
26
23
20
18
16
14
100
78
64
54
46
40
35
31
28
25
23
100
75
59
48
40
34
29
25
23
20
18
92
72
59
49
42
37
32
29
26
23
21
92
69
54
44
37
32
27
24
21
19
17
84
65
54
45
39
34
30
26
24
22
20
84
63
50
41
34
29
25
22
20
18
16
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Ty p i c a l VC P Pe r c e n t a g e s
%Fixture
15.2
25.6
49.1
79.2
20.8
100.0
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Height Along
8.5’
10.0’
34
46
23
30
19
24
18
24
13
18
Height Across
8.5’
10.0’
19
30
10
16
3
5
13
19
4
6
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
108
95
85
77
70
64
59
54
50
47
44
108
89
76
65
57
51
45
41
37
34
31
108 108
84 79
68 62
57 50
48 41
42 35
36 30
32 26
29 23
26 20
23 18
103
90
80
73
66
60
56
51
48
45
42
103
85
72
62
55
48
43
39
36
33
30
103
80
65
54
46
40
35
31
28
25
23
103
76
59
48
40
34
29
25
22
20
18
20%
50%
50 30 10
30%
50 30 10
50
94
77
66
57
50
44
40
36
33
30
28
86
70
59
51
45
40
36
33
30
28
25
79
64
54
47
41
37
33
30
27
25
23
94
73
60
50
43
37
33
29
26
23
21
94
70
55
45
37
32
27
24
21
19
17
86
67
55
46
39
34
30
27
24
22
20
86
64
51
41
35
29
25
22
20
18
16
Zonal Lumen Summary
Ty p i c a l VC P Pe r c e n t a g e s
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Lumens
631
1062
2041
3304
858
4161
%Lamp
14.3
24.1
46.4
75.1
19.5
94.6
%Fixture
15.2
25.5
49.0
79.4
20.6
100.0
10%
30 10
79
61
50
42
36
31
28
25
22
20
19
Height Along
8.5’
10.0’
23
33
14
19
11
15
11
16
8
11
0%
0
79
59
47
38
32
27
24
21
19
17
15
75
55
44
35
29
25
21
19
16
15
13
Height Across
8.5’
10.0’
12
20
6
10
2
3
7
12
2
3
ORDERING INFORMATION
S A M P L E N U M B E R : S N F - 2 2 8 T 5 - U N V- E B T 1 - U
Tandem
Blank=2' or
4' Length
8T=8' Length
Number of Lamps
1=1 Lamp
2=2 Lamp
Series
SNF=Commercial
Narrow Striplite
Wattage
14T5=14W T5 (24")
24T5=24W T5HO (24")
28T5=28W T5 (48")
54T5=54W T5HO (48")
(Not Included)
Ballast Type (1), (4)
EBT
Voltage (1)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277
No. of Ballast
1 or 2
(1)
Options
GL=Single Element Fuse
GM=Double Element Fuse
EL5LP=Emergency Installed (3) , (4)
EL5HOLP=Emergency Installed for T5HO
= T5 or T5HO Linear
Electronic Program
Rapid Start.
Total Harmonic
Distortion < 10%
Ballast Factor/Type
(For 28W T5 and 14WT5 Lamps Only)
N=Normal Light Output .95 BF (1)
H=High Light Output 1.15 BF (1), (6)
NDIM=Normal .95-1.0 BF Step Dimming (7)
HDIM=High 1.15 BF Step Dimming (6), (7)
Options
RIF1=Radio Interference
Suppressor
6-3/18 SJT-C&P-515P=
Cord & Plug (120V)
(15 AMP)(5)
6-3/18 SJT-C&P L715P=
Cord & Plug (277V)
(15 AMP)(5)
PI/CPI=Plug-In Option(5)
(1)
ACCESSORIES (Order Separately)
AYC-Chain/Set=36" Chain Hanger (Use 1 Set Per Fixture)
SCF=Fixed Stem Set (Specify Length)
SCS=Swivel Stem Set (Specify Length)
SCA=Adjustable 48" Stem Set
EYE-CHAIN/SET-B=Eye Bolt Chain (Use 1 Set Per Fixture)
SNF-ASY-4T5 (2) =3" Asymmetric Reflector (Specify 2' or 4')
SNF-SYM-4T5 (2) =6" Symmetric Reflector (Specify 2' or 4')
SNF-REV-4T5(2) =Reverse Asymmetric Reflector (Specify 2' or 4')
WG/SNFT5-4FT=Wire Guard
A1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling (Use 2 Per Fixture)
TOGGLE=Single Toggle NO. 2 (Specify Length)
Y-TOGGLE=Y Toggle NO. 2 (Specify Length)
Packaging
U=Unit Pack
6B=6 Bulk
Packing (96")
(2)
NOTES: Products also available in non-US voltages and frequencies for international markets. For SilverLining reflector add
(3)
(4)
SS in Catalog Number, Example: SNF-ASY-SS-4T5. Not available for 2' version. Maximum width clearance for ballast in
(5)
(6)
channel is 2-7/32". Socket brackets left uninstalled. 1-Lamp ballast in the High Ballast factor not available. 2-Lamp ballast
(7)
will not operate 1-Lamp. Step Dimming ballast available for 28W T5 and 14WT5 lamps only.
Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and
ordering information.
(Additional Accessories Available. See Options and Accessories Section.)
SHIPPING INFORMATION
Catalog No.
SNF-114T5
SNF-124T5
SNF-128T5
SNF-154T5
SNF-214T5
SNF-224T5
SNF-228T5
SNF-254T5
8TSNF-228T5
Specifications and Dimensions subject to change without notice.
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
Wt.
4
5
5
5
6
6
6
6
14
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
ADF081659
05/18/2009 6:48:12 PM
Download