COOPER LIGHTING - SURE-LITES ® DESCRIPTION The CC Contractor's Choice FasTest(TM) Ultra High-Capacity Emergency Lighting Unit is an affordable, attractive alternative to standard twoheaded emergency lighting units. All components snap together to facilitate installation in 5 minutes or less. Field versatility is not sacrificed for cost, both lighting heads offer full horizontal and vertical adjustability. Moreover, proper operation of the transfer circuit and emergency lamps can be quickly and safely verified by using a convenient laser pointer (accessory). In addition, Watchguard EMS self-diagnostic system is standard (CC7NCSD only). The CC unit is ideal for applications demanding minimum cost but maximum flexibility, reliability, convenience and aesthetics. Type Catalog # Project Date Comments Prepared by S P E C I F I C AT I O N F E AT U R E S E l e c t ro n i c H o u s i n g C o n s t ru c t i o n - Dual-Voltage Input 120/277 VAC, 60Hz - Line-Latching - Solid-State Voltage Limited Charger - Solid-State Switching - Low-Voltage Disconnect - Brownout Circuit - Overload/Short Circuit Protection - Push-Button Test Switch/Power Indicator Light - Remote Photocell Test Switch (requires accessory laser for activation) - Push-In AC Power Connectors Facilitate Installation - Automatic 30-Sec. Test Upon Switch Activation - Watchguard EMS Self-Diagnostic System (Standard) - Snap-Fit Component Design Facilitates Under-5-Minute Installation - Reinforcing Ribs Throughout to Provide Maximum Strength - Injection-Molded, Color-Stable High-Impact UL 94-5V Rated Polycarbonate Housing and Mounting Plate - Designer-White Textured Finish - Knockouts/Cutouts Provided in Housing for Surface Conduit Attachment - Universal J-Box Mounting Pattern - Keyhole Mounting slots B a tte r y - Sealed Lead Calcium, Recombination - Maintenance-Free, Long-Life - Full Recharge Time, 24 hrs. (max) - Polarized Battery Terminals 19” [483mm] 9 7/8” [250mm] - Housing has (8) Locations for Mounting of Heads [(3) optional bottom-mount and (3) optional top-mount locations] - Optional square and MR16 heads available - MR16 heads accept up to 50W lamps. Code Compliance - UL 924 Listed - Life Safety NFPA 101 - NEC/OSHA - Most State and Local Codes CC9 SERIES Wa rra n t y - Unit: 1-Year - Battery: 5-Year Pro-Rata H e a d / L a m p Da t a - Two 12W, 12V Heads Standard - Standard Round and Square Head Design Accepts 12V Sealed Beam PAR 36 Lamps, 25W Max. MR16 Design Accepts up to 50W - Glare-Free Lens - Fully Adjustable Lamp Housing - High-Impact Polycarbonate - Matches Housing Finish - Remote Capability M o u n t i n g R e q u i re m e n t P O LYC A R B O N AT E - Mount only on a vertical plane (i.e. wall mount, etc.) U LT R A H I G H C A PAC I T Y SEALED LEAD C A L C I U M B AT T E RY C O NT R AC TO R ' S C H O I C E FAST E ST L AS E R T E ST WAT C H G U A R D E M S S E L F- D I AG N O ST I C SY ST E M E M E R G E N CY L I G H T I N G 12” [305mm] ENERGY D ATA 8 7/16” [214mm] T.H.D.: 120V=<36% 277V=<40% Standby Mode 21 11/16” [551mm] (Fully Charged Model CC11SD Battery) Input Power: Model CC9SD 120V=5.6W Input Power: 277V=9.4W 120V=9.1W 277V=6.3W Input Current (Max.): 120V=.02A Input Current (Max.): 277V=.01A 120V=.03A 277V=.01A ORDERING INFORMATION Power Factor: 120V=>.39 Power Factor: 277V=>.30 120V=>.30 T.H.D.: 277V=>.34 120V=<37% 277V=<38% T.H.D.: Series Options 1, 2, 3 MRT=MR16 Lamp Heads4 Accessories CC9SD CC10SD SQ=Square Heads4 2MSWH=Mounting Shelf V=Voltmeter TDM=Time Delay Monitor Protective Housing CC11SD CC12SD SM=Side Mount Lamps5 TM=Top Mount Lamps5 BM=Bottom Mount Lamps5 6 Mounting Kit WG3=Wire Guard VS1=Polycarbonate Vandal Shield 120V=<33% Model CC12SD 277V=<39% Input Power: 120V=13W Model CC10SD 120V=5.1W Input Current (Max.): 277V=5.2W 120V=.04A VS1WP=Polycarbonate Vandal Shield - Weather Resistant LASER=Key Chain, Red Laser Pointer (activation tested at 30 feet). 277V=14.8W Input Power: 277V=.02A Input Current (Max.): 120V=.02A Power Factor: 277V=.01A 120V=>.30 277V=>.32 Notes: 1 Add as a suffix. 2 Alternate Lamps, Head Types, No Head, Multiple Heads and other options. Consult your Cooper Lighting Representative. 3 Alternate lamps specify quantity, lamp number (from Technical Information sections) and mounting location, e.g. CC9SD213SM319TM219BM 4 12W lamp standard. 5 Side Mount Heads (2 lamp max.), Top Mount and Bottom Mount Heads (3 lamp max.) 6 Order separately. Power Factor: 120V=>.27 T.H.D.: 277V=>.34 120V=<44% 277V=<40% Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADX042230 pc 2010-08-20 16:45:38 CC SERIES E L E C T R I C A L R AT I N G S Model Rated Wattage to 87 1/2% of Rated D.C. Voltage Lamp Information DC Voltage Type CC9SD CC10SD C11SD CC12SD CC9SDMRT CC10SDMRT CC11SDMRT CC12SDMRT 12 12 12 12 12 12 12 12 1 1/2 Hours Remote Capability 60 200 240 300 160 200 240 300 136W 176W 216W 276W 136W 176W 216W 276W Incadescent Incadescent Incadescent Incadescent MR16 MR16 MR16 MR16 Wattage Number 12 ea. 12 ea. 12 ea. 12 ea. 12 ea. 12 ea. 12 ea. 12 ea. 029-132 029-132 029-132 029-132 029-141 029-141 029-141 029-141 Spacing (3) 24’ 24’ 24’ 24’ 50’ 50’ 50’ 50’ P H OTO M E T R I C S 029-132 24' Spacing Illuminance Values(Fc) Average=3.09 Maximum =14.6 Minimum =0.4 Avg/Min Ratio=7.73 Max/Min Ratio=8.33 Max/Min Ratio=36.50 Illuminance Values(Fc) Average=0.84 Maximum =5.8 Minimum =0.1 Avg/Min Ratio=8.40 Max/Min Ratio=58.00 For Standard Fixture: CC9SD*** 029-141 50' Spacing For Standard Fixture: CC9SDMRT*** N OT E S The “Rule of Thumb” spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9-foot ceiling with a 6-foot wide walkway and 3-foot path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 8.5 feet. Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance. Specifications and dimensions subject to change without notice. Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADX042230 pc 2010-08-20 16:45:38 2010-08-11 15:08:10 CC SERIES T E C H N I C A L DATA Lamps O ve rl o a d a n d S h o rt - C i rc u i t P ro te c t i o n Self-Diagnostics Designed specifically for emergency lighting applications, the PAR 36 12V sealed-beam type design insures optimum glare-free trapezoidal light distribution along with horizontal and vertical adjustment by rotating the lens within the housing. The solid-state overload monitoring device in the DC circuit disconnects the lamp load from the battery should excessive wattage demands be made and automatically resets when the overload or short circuit is removed. This overload current protective feature eliminates the need for fuses or circuit breakers for the DC load. The unit incorporates a solid-state switching transistor which eliminates corroded and pitted contacts or mechanical failures associated with relays. The switching circuit is designed to detect a loss of AC voltage and automatically energizes the lamps. Upon restoration of the AC power, the emergency lamps will switch off and the charger will automatically recharge the battery. The self-diagnostic unit will automatically perform all tests required by UL924, and NFPA 101. The system indicates the status of the exit at all times using the LED indicator near the test switch on the side of the unit. A 90-minute battery power (emergency mode) simulation test will occur randomly once every six months. A 30 second battery power simulation test will occur every 30 days. The charger function is tested upon initial power-up and after every battery discharge cycle thereafter. The exit lamp circuit and AC/DC power transfer circuit is monitored continuously. The charging mode is also monitored. The unit goes into a high charge mode for 24 hours the first time AC power is applied and when a discharge causes the battery voltage to fall below its nominal value. Pressing the test switch causes the unit to use battery power and test the battery capacity for 30 seconds. The LED indicator is off when the unit is in the emergency mode and on continuously when the unit is fully charged. The LED blinks when the unit is in the high charge mode. It blinks twice (then repeats) when the battery needs to be replaced, or if it is disconnected. It blinks three times if there is a circuit board (charger or AC/DC transfer function) failure, and four times if the exit lamps fail. L ow- Vo l t a ge D i s c o n n e c t S e a l e d L e a d C a l c i u m B a tte r y When the battery’s terminal voltage falls below 80% of the rated voltage, the low-voltage circuitry disconnects the lighting load. The disconnect remains in effect until normal utility power is restored, preventing deep battery discharge. The fully sealed, long-life, maintenance-free lead-calcium battery is ideal for emergency lighting applications. These recombinant cycle batteries typically provide eight to ten years of life and may be operated in any position. Housing The subtly detailed Model CC housing is constructed of flame-retardant and impactresistant polycarbonate in a color-stable designer-white finish. All electrical components are securely attached in the housing and prewired for fast AC connection. The housing snaps on to the hinged mounting plate with two integral locking tabs. The mounting plate has keyhole mounting slots and a universal mounting pattern for quick, efficient installation.The housing contains knockouts/cutouts for surface conduit attachment. All structural components are designed with reinforcing ribs to add additional rigidity and to maximize structural integrity. L i n e - L a t ch e d Sure-Lites’ line-latched electronic circuitry makes installation easy and economical. A labor efficient AC-activated load switch prevents the lamps from turning on during installation to a non-energized AC circuit. Line-latching eliminates the need for a contractor’s return to a job site to connect the batteries when the building’s main power is permanently turned on. S o l i d - S t a te C h a rge r Supplied with a 120/277 VAC, voltage regulated solid-state charger. Immediately upon restoration of AC current after a power failure, the charger provides a high charge rate. The charge circuit reacts to the condition of the battery and alters the rate of charge in order to maintain peak battery capacity and maximize battery life. Solid-state construction recharges the battery following a power failure in accordance with UL 924. B row n o u t C i rc u i t The brownout circuit in Sure-Lites units monitors the flow of AC current to the unit and activates the emergency lighting system when a predetermined reduction of AC power occurs. This dip in voltage will cause most ballasted fixtures to extinguish causing loss of normal lighting even though a total power failure has not occurred. S o l i d - S t a te Tra n s fe r Wa rra n t y Te s t Sw i t ch / Powe r I n d i c a to r L i g h t Conveniently located combination Test Switch/Power Indicator Light allows for manual verification of proper operation of the transfer circuit and emergency lamps. The emergency lamps will test for 30 seconds when activated. All Sure-Lites units are backed by a firm oneyear warranty against defect in material and workmanship (excluding lamps). Maintenancefree, long-life, sealed lead calcium batteries carry a five-year Pro-Rata warranty. P h o to c e l l Te s t Sw i t ch Allows verification of proper operation of the transfer circuit and emergency lamps with a laser pointer (laser is sold as an accessory). The emergency lamps will test for 30 seconds when activated. Specifications and dimensions subject to change without notice. Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADX042230 pc 2010-08-20 16:45:38 2010-08-11 15:08:10