COOPER LIGHTING - SURE-LITES Type ®

advertisement
COOPER LIGHTING - SURE-LITES ®
DESCRIPTION
The CC Contractor's Choice FasTest(TM) Ultra High-Capacity Emergency
Lighting Unit is an affordable, attractive alternative to standard twoheaded emergency lighting units. All components snap together to
facilitate installation in 5 minutes or less. Field versatility is not sacrificed
for cost, both lighting heads offer full horizontal and vertical adjustability.
Moreover, proper operation of the transfer circuit and emergency lamps
can be quickly and safely verified by using a convenient laser pointer
(accessory). In addition, Watchguard EMS self-diagnostic system is
standard (CC7NCSD only). The CC unit is ideal for applications
demanding minimum cost but maximum flexibility, reliability,
convenience and aesthetics.
Type
Catalog #
Project
Date
Comments
Prepared by
S P E C I F I C AT I O N F E AT U R E S
E l e c t ro n i c
H o u s i n g C o n s t ru c t i o n
- Dual-Voltage Input 120/277 VAC,
60Hz
- Line-Latching
- Solid-State Voltage Limited
Charger
- Solid-State Switching
- Low-Voltage Disconnect
- Brownout Circuit
- Overload/Short Circuit
Protection
- Push-Button Test Switch/Power
Indicator Light
- Remote Photocell Test Switch
(requires accessory laser
for activation)
- Push-In AC Power Connectors
Facilitate Installation
- Automatic 30-Sec. Test
Upon Switch Activation
- Watchguard EMS Self-Diagnostic
System (Standard)
- Snap-Fit Component Design
Facilitates Under-5-Minute
Installation
- Reinforcing Ribs Throughout to
Provide Maximum Strength
- Injection-Molded, Color-Stable
High-Impact UL 94-5V Rated
Polycarbonate Housing and
Mounting Plate
- Designer-White Textured Finish
- Knockouts/Cutouts Provided
in Housing for Surface Conduit
Attachment
- Universal J-Box Mounting
Pattern
- Keyhole Mounting slots
B a tte r y
- Sealed Lead Calcium,
Recombination
- Maintenance-Free, Long-Life
- Full Recharge Time, 24 hrs. (max)
- Polarized Battery Terminals
19”
[483mm]
9 7/8”
[250mm]
- Housing has (8) Locations for
Mounting of Heads [(3) optional
bottom-mount and (3) optional
top-mount locations]
- Optional square and MR16
heads available
- MR16 heads accept up
to 50W lamps.
Code Compliance
- UL 924 Listed
- Life Safety NFPA 101
- NEC/OSHA
- Most State and Local Codes
CC9
SERIES
Wa rra n t y
- Unit: 1-Year
- Battery: 5-Year Pro-Rata
H e a d / L a m p Da t a
- Two 12W, 12V Heads Standard
- Standard Round and Square Head
Design Accepts 12V Sealed Beam
PAR 36 Lamps, 25W Max. MR16
Design Accepts up to 50W
- Glare-Free Lens
- Fully Adjustable Lamp Housing
- High-Impact Polycarbonate
- Matches Housing Finish
- Remote Capability
M o u n t i n g R e q u i re m e n t
P O LYC A R B O N AT E
- Mount only on a vertical plane
(i.e. wall mount, etc.)
U LT R A H I G H C A PAC I T Y
SEALED LEAD
C A L C I U M B AT T E RY
C O NT R AC TO R ' S C H O I C E
FAST E ST L AS E R T E ST
WAT C H G U A R D E M S
S E L F- D I AG N O ST I C SY ST E M
E M E R G E N CY L I G H T I N G
12”
[305mm]
ENERGY
D ATA
8 7/16”
[214mm]
T.H.D.:
120V=<36%
277V=<40%
Standby Mode
21 11/16”
[551mm]
(Fully Charged
Model CC11SD
Battery)
Input Power:
Model CC9SD
120V=5.6W
Input Power:
277V=9.4W
120V=9.1W
277V=6.3W
Input Current (Max.):
120V=.02A
Input Current (Max.):
277V=.01A
120V=.03A
277V=.01A
ORDERING INFORMATION
Power Factor:
120V=>.39
Power Factor:
277V=>.30
120V=>.30
T.H.D.:
277V=>.34
120V=<37%
277V=<38%
T.H.D.:
Series
Options 1, 2, 3
MRT=MR16 Lamp Heads4
Accessories
CC9SD
CC10SD
SQ=Square Heads4
2MSWH=Mounting Shelf
V=Voltmeter
TDM=Time Delay Monitor
Protective Housing
CC11SD
CC12SD
SM=Side Mount Lamps5
TM=Top Mount Lamps5
BM=Bottom Mount Lamps5
6
Mounting Kit
WG3=Wire Guard
VS1=Polycarbonate Vandal Shield
120V=<33%
Model CC12SD
277V=<39%
Input Power:
120V=13W
Model CC10SD
120V=5.1W
Input Current (Max.):
277V=5.2W
120V=.04A
VS1WP=Polycarbonate Vandal Shield - Weather Resistant
LASER=Key Chain, Red Laser Pointer (activation tested at 30
feet).
277V=14.8W
Input Power:
277V=.02A
Input Current (Max.):
120V=.02A
Power Factor:
277V=.01A
120V=>.30
277V=>.32
Notes:
1 Add as a suffix. 2 Alternate Lamps, Head Types, No Head, Multiple Heads and other options. Consult your Cooper Lighting Representative. 3 Alternate lamps specify quantity, lamp number (from Technical Information sections) and mounting location, e.g. CC9SD213SM319TM219BM 4 12W lamp standard. 5 Side Mount
Heads (2 lamp max.), Top Mount and Bottom Mount Heads (3 lamp max.) 6 Order separately.
Power Factor:
120V=>.27
T.H.D.:
277V=>.34
120V=<44%
277V=<40%
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADX042230 pc
2010-08-20 16:45:38
CC SERIES
E L E C T R I C A L R AT I N G S
Model
Rated Wattage to 87 1/2% of Rated D.C. Voltage
Lamp Information
DC Voltage
Type
CC9SD
CC10SD
C11SD
CC12SD
CC9SDMRT
CC10SDMRT
CC11SDMRT
CC12SDMRT
12
12
12
12
12
12
12
12
1 1/2 Hours
Remote Capability
60
200
240
300
160
200
240
300
136W
176W
216W
276W
136W
176W
216W
276W
Incadescent
Incadescent
Incadescent
Incadescent
MR16
MR16
MR16
MR16
Wattage
Number
12 ea.
12 ea.
12 ea.
12 ea.
12 ea.
12 ea.
12 ea.
12 ea.
029-132
029-132
029-132
029-132
029-141
029-141
029-141
029-141
Spacing (3)
24’
24’
24’
24’
50’
50’
50’
50’
P H OTO M E T R I C S
029-132
24' Spacing
Illuminance Values(Fc)
Average=3.09
Maximum =14.6
Minimum =0.4
Avg/Min Ratio=7.73
Max/Min Ratio=8.33
Max/Min Ratio=36.50
Illuminance Values(Fc)
Average=0.84
Maximum =5.8
Minimum =0.1
Avg/Min Ratio=8.40
Max/Min Ratio=58.00
For Standard Fixture: CC9SD***
029-141
50' Spacing
For Standard Fixture: CC9SDMRT***
N OT E S
The “Rule of Thumb” spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100
feet long, 9-foot ceiling with a 6-foot wide walkway and 3-foot path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 8.5 feet.
Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance.
Specifications and dimensions subject to change without notice.
Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADX042230 pc
2010-08-20 16:45:38
2010-08-11 15:08:10
CC SERIES
T E C H N I C A L DATA
Lamps
O ve rl o a d a n d S h o rt - C i rc u i t P ro te c t i o n
Self-Diagnostics
Designed specifically for emergency lighting
applications, the PAR 36 12V sealed-beam type
design insures optimum glare-free trapezoidal
light distribution along with horizontal and
vertical adjustment by rotating the lens within
the housing.
The solid-state overload monitoring device in
the DC circuit disconnects the lamp load from
the battery should excessive wattage demands
be made and automatically resets when the
overload or short circuit is removed. This
overload current protective feature eliminates
the need for fuses or circuit breakers for the DC
load.
The unit incorporates a solid-state switching
transistor which eliminates corroded and pitted
contacts or mechanical failures associated with
relays. The switching circuit is designed to
detect a loss of AC voltage and automatically
energizes the lamps. Upon restoration of the AC
power, the emergency lamps will switch off and
the charger will automatically recharge the
battery.
The self-diagnostic unit will automatically
perform all tests required by UL924, and NFPA
101. The system indicates the status of the exit at
all times using the LED indicator near the test
switch on the side of the unit. A 90-minute
battery power (emergency mode) simulation
test will occur randomly once every six months.
A 30 second battery power simulation test will
occur every 30 days. The charger function is
tested upon initial power-up and after every
battery discharge cycle thereafter. The exit lamp
circuit and AC/DC power transfer circuit is
monitored continuously. The charging mode is
also monitored. The unit goes into a high charge
mode for 24 hours the first time AC power is
applied and when a discharge causes the
battery voltage to fall below its nominal value.
Pressing the test switch causes the unit to use
battery power and test the battery capacity for
30 seconds. The LED indicator is off when the
unit is in the emergency mode and on
continuously when the unit is fully charged. The
LED blinks when the unit is in the high charge
mode. It blinks twice (then repeats) when the
battery needs to be replaced, or if it is
disconnected. It blinks three times if there is a
circuit board (charger or AC/DC transfer
function) failure, and four times if the exit lamps
fail.
L ow- Vo l t a ge D i s c o n n e c t
S e a l e d L e a d C a l c i u m B a tte r y
When the battery’s terminal voltage falls below
80% of the rated voltage, the low-voltage
circuitry disconnects the lighting load. The
disconnect remains in effect until normal utility
power is restored, preventing deep battery
discharge.
The fully sealed, long-life, maintenance-free
lead-calcium battery is ideal for emergency
lighting applications. These recombinant cycle
batteries typically provide eight to ten years of
life and may be operated in any position.
Housing
The subtly detailed Model CC housing is
constructed of flame-retardant and impactresistant polycarbonate in a color-stable
designer-white finish. All electrical components
are securely attached in the housing and
prewired for fast AC connection. The housing
snaps on to the hinged mounting plate with two
integral locking tabs. The mounting plate has
keyhole mounting slots and a universal
mounting pattern for quick, efficient
installation.The housing contains
knockouts/cutouts for surface conduit
attachment. All structural components are
designed with reinforcing ribs to add additional
rigidity and to maximize structural integrity.
L i n e - L a t ch e d
Sure-Lites’ line-latched electronic circuitry
makes installation easy and economical. A labor
efficient AC-activated load switch prevents the
lamps from turning on during installation to a
non-energized AC circuit. Line-latching
eliminates the need for a contractor’s return to a
job site to connect the batteries when the
building’s main power is permanently turned
on.
S o l i d - S t a te C h a rge r
Supplied with a 120/277 VAC, voltage regulated
solid-state charger. Immediately upon
restoration of AC current after a power failure,
the charger provides a high charge rate. The
charge circuit reacts to the condition of the
battery and alters the rate of charge in order to
maintain peak battery capacity and maximize
battery life. Solid-state construction recharges
the battery following a power failure in
accordance with UL 924.
B row n o u t C i rc u i t
The brownout circuit in Sure-Lites units
monitors the flow of AC current to the unit and
activates the emergency lighting system when a
predetermined reduction of AC power occurs.
This dip in voltage will cause most ballasted
fixtures to extinguish causing loss of normal
lighting even though a total power failure has
not occurred.
S o l i d - S t a te Tra n s fe r
Wa rra n t y
Te s t Sw i t ch / Powe r I n d i c a to r L i g h t
Conveniently located combination Test
Switch/Power Indicator Light allows for manual
verification of proper operation of the transfer
circuit and emergency lamps. The emergency
lamps will test for 30 seconds when activated.
All Sure-Lites units are backed by a firm oneyear warranty against defect in material and
workmanship (excluding lamps). Maintenancefree, long-life, sealed lead calcium batteries
carry a five-year Pro-Rata warranty.
P h o to c e l l Te s t Sw i t ch
Allows verification of proper operation of the
transfer circuit and emergency lamps with a
laser pointer (laser is sold as an accessory). The
emergency lamps will test for 30 seconds when
activated.
Specifications and dimensions subject to change without notice.
Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADX042230 pc