5073E-T MANAGED ETHERNET SWITCH INSTALLATION GUIDE
Terminal Block for Digital Inputs (DI0, DI1)
and Digital Outputs (DO0, DO1)
Terminal Block for Power 1,
Power 2 and Fault Alarm Contact
POWER SUPPLY WIRING
10/100/1000T RJ-45 Ethernet Ports
5073E-T
Surge EARTH
Power Supply 2*
100/1000M SFP Sockets (3)
RS-232 Console Port
10/100/1000T RJ-45 Ethernet Port
10/100 TX RJ-45 Ethernet Ports (3)
DC
DC Power Input Range:
12VDC ~ 48VDC
DC
Power Supply 1
10/100 TX
RJ-45 Ethernet Ports (4)
Power Input, Fault Alarm Contact, and Digital Input and Digital Output Wire Gauge: 12 ~ 24 AWG RJ-45.
Port Connection: Use four twisted pair Cat 5e or Cat 6 cables less than 100 meters long.
Fiber Connection: See the 5073E-T Users Manual for details.
NOTE This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or
non-hazardous locations only.
WARNING – EXPLOSION HAZARD!
• Do not disconnect equipment while the circuit is live unless the area is known to be free
of ignitable concentrations.
• Do not disconnect equipment unless power has been removed or the area is know to be
non-hazardous.
• Substitution of any components may impair suitability for Class I, Division 2.
• The area must be known to be non-hazardous before servicing or replacing the unit and
before installing the unit.
WARNING Exposure to some chemicals may degrade the sealing properties of materials used
in the sealed relay device. It is recommended to inspect the sealed relay device periodically
and to check for any degradation of the materials and to replace the complete product (not
the sealed device) if any degradation is found.
*Power Supply 2 is used for
redundant supplies.
1. Insert DC power wires into the contacts for Power Supply 1 and 2.
2. Tighten the terminal screws to ensure that the wires do not come loose.
DIGITAL INPUT/OUTPUT & FAULT CONTACT WIRING
+V Supply
5073E-T
DC Load (relay, lamp, etc)
DO Max Rating 40V 200mA
DO1
+Using Switch:
Inputs internally pulled high.
Switch to GND will turn DI off.
*Using Input Supply:
Powered Input Levels
-30 to +2VDC = Off
+10 to +30 VDC = On
Surge EARTH
DO0
FAULT ALARM
CONTACT
1A@24V
N/C Contact.
Contact will open
when a fault occurs
+Switch can be used on either DI0 or DI1.
*Input Supply can be used on either DI0 or DI1.
©2013 Cooper Bussmann
www.cooperbussmann.com/wirelessresources
06/13Page 1 of 2Version 1.0
5073E-T MANAGED ETHERNET SWITCH INSTALLATION GUIDE
RS-232 CONSOLE PORT CABLE
DIN-RAIL MOUNTING
1. Insert the top of the DIN rail clip
onto the DIN rail.
2. Press the 5073E-T onto the DIN rail
until it clicks into place.
Pin Connections
DB-9 Female
RJ-45
Pin - 2
2 - Orange
Pin - 3
3 - Green/White
Pin - 5
5 - Blue/White
Other Pins - NC
Other Pins - NC
RS-232 Connection Setting:
9600 baud, 8 bits, no parity,
1 stop bit, no flow control
CONNECTING TRANSCEIVER & FIBER CABLE
3. Check the module is securely attached to the DIN rail.
4. To remove the 5073E-T from the DIN rail, press down on the rear top
of the module and swing the bottom of the module forward.
WALL MOUNT PLATE MOUNTING
Insert the transciever into the
100/1000 SFP socket and
slide until you hear a click.
Transceiver is inserted.
Insert the LC fiber connector
into the transceiver.
REMOVING FIBER CABLE & TRANSCEIVER
Remove the LC connector
from the transceiver.
1. Remove the DIN rail from the 5073E-T by
loosening the three screws.
2. Place the wall mount plates on the rear panel of
the 5073E-T.
3. Use six screws to screw the wall mount plates
onto the 5073E-T.
4. Use the hook holes at the corners of the wall
mount plates to mount the 5073E-T on the wall.
5. To remove the 5073E-T from the wall, reverse
the above steps.
Pull the transceiver out by the
plastic handle.
©2013 Cooper Bussmann
www.cooperbussmann.com/wirelessresources
06/13Page 2 of 2Version 1.0