5073E-T MANAGED ETHERNET SWITCH INSTALLATION GUIDE Terminal Block for Digital Inputs (DI0, DI1) and Digital Outputs (DO0, DO1) Terminal Block for Power 1, Power 2 and Fault Alarm Contact POWER SUPPLY WIRING 10/100/1000T RJ-45 Ethernet Ports 5073E-T Surge EARTH Power Supply 2* 100/1000M SFP Sockets (3) RS-232 Console Port 10/100/1000T RJ-45 Ethernet Port 10/100 TX RJ-45 Ethernet Ports (3) DC DC Power Input Range: 12VDC ~ 48VDC DC Power Supply 1 10/100 TX RJ-45 Ethernet Ports (4) Power Input, Fault Alarm Contact, and Digital Input and Digital Output Wire Gauge: 12 ~ 24 AWG RJ-45. Port Connection: Use four twisted pair Cat 5e or Cat 6 cables less than 100 meters long. Fiber Connection: See the 5073E-T Users Manual for details. NOTE This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or non-hazardous locations only. WARNING – EXPLOSION HAZARD! • Do not disconnect equipment while the circuit is live unless the area is known to be free of ignitable concentrations. • Do not disconnect equipment unless power has been removed or the area is know to be non-hazardous. • Substitution of any components may impair suitability for Class I, Division 2. • The area must be known to be non-hazardous before servicing or replacing the unit and before installing the unit. WARNING Exposure to some chemicals may degrade the sealing properties of materials used in the sealed relay device. It is recommended to inspect the sealed relay device periodically and to check for any degradation of the materials and to replace the complete product (not the sealed device) if any degradation is found. *Power Supply 2 is used for redundant supplies. 1. Insert DC power wires into the contacts for Power Supply 1 and 2. 2. Tighten the terminal screws to ensure that the wires do not come loose. DIGITAL INPUT/OUTPUT & FAULT CONTACT WIRING +V Supply 5073E-T DC Load (relay, lamp, etc) DO Max Rating 40V 200mA DO1 +Using Switch: Inputs internally pulled high. Switch to GND will turn DI off. *Using Input Supply: Powered Input Levels -30 to +2VDC = Off +10 to +30 VDC = On Surge EARTH DO0 FAULT ALARM CONTACT 1A@24V N/C Contact. Contact will open when a fault occurs +Switch can be used on either DI0 or DI1. *Input Supply can be used on either DI0 or DI1. ©2013 Cooper Bussmann www.cooperbussmann.com/wirelessresources 06/13Page 1 of 2Version 1.0 5073E-T MANAGED ETHERNET SWITCH INSTALLATION GUIDE RS-232 CONSOLE PORT CABLE DIN-RAIL MOUNTING 1. Insert the top of the DIN rail clip onto the DIN rail. 2. Press the 5073E-T onto the DIN rail until it clicks into place. Pin Connections DB-9 Female RJ-45 Pin - 2 2 - Orange Pin - 3 3 - Green/White Pin - 5 5 - Blue/White Other Pins - NC Other Pins - NC RS-232 Connection Setting: 9600 baud, 8 bits, no parity, 1 stop bit, no flow control CONNECTING TRANSCEIVER & FIBER CABLE 3. Check the module is securely attached to the DIN rail. 4. To remove the 5073E-T from the DIN rail, press down on the rear top of the module and swing the bottom of the module forward. WALL MOUNT PLATE MOUNTING Insert the transciever into the 100/1000 SFP socket and slide until you hear a click. Transceiver is inserted. Insert the LC fiber connector into the transceiver. REMOVING FIBER CABLE & TRANSCEIVER Remove the LC connector from the transceiver. 1. Remove the DIN rail from the 5073E-T by loosening the three screws. 2. Place the wall mount plates on the rear panel of the 5073E-T. 3. Use six screws to screw the wall mount plates onto the 5073E-T. 4. Use the hook holes at the corners of the wall mount plates to mount the 5073E-T on the wall. 5. To remove the 5073E-T from the wall, reverse the above steps. Pull the transceiver out by the plastic handle. ©2013 Cooper Bussmann www.cooperbussmann.com/wirelessresources 06/13Page 2 of 2Version 1.0