. INSTALLATION INSTRUCTIONS V90031 QUIET CEILING ROUND TRIM QCT900, QCM500 BASED SERIES Page 1 of 3 Avoid Fire or Electric Shock THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. *Installation Instructions for qualified electricians only. *Install per National Electrical Code and local regulations. *Read Installation Instructions completely before installation. *Failure to follow Installation Instructions may void warranties. Fixture Mounting: 8. Butterfly Mounting (Commerical): 1. Fixture comes equipped with Universal Mounting brackets and can take common 1 inch or 1-1/2 inch Black Iron or Galvanized Mounting Channels (Supplied By Others). 2. Position Fixture so the Mounting Channels lie on top of ceiling runners. 3. Fasten Mounting Channels securely to ceiling runners. 4. Secure Mounting channels to Universal Butterfly Mounting Brackets with wire tire downs. 5. Adjust elevation of Fixture so Mudding Ring Edge will be flush with surface of finished Ceiling by loosening two (2) 1/4 inch Hex Screws on both Universal Mounting Brackets. See Fig. 1. 6. Tighten two (2) 1/4 inch Hex Screws on both Universal Butterfly Mounting Brackets to secure Fixture. See Fig. 1. Hanger Bar Mounting (Residential): 7. Adjustable hanger bars are preassembled with mounting bracket and provided with fixture.The preassembled hanger bars must attached to the fixture prior to installation.Aligh with two screws on end of fixture and tighten .Hanger bars are installed in Fig.1. Mounting Channel (Supply by Others) Fixture Housing Cover Hanger bars can be used with grid ceilings having T bars and joist installations of wood.Adjustable hanger bars are for use in installations with spacing from 10" to 24", while maintaining minimum 1/2" spacing around fixture For 10" Spacing,the hanger bar can be shorten by breaking them at score line as shown in Fig.2. Grid Ceiling Installation (Figure 3): Step 1 Extend bar hangers between the T bars and slide the slots in the mounting tabs over the T-bars. Step 2 Adjust housing platform position by sliding back and forth on bar hangers to desired position. Housing may be locked in the position by tightening bar hanger locking screws on housing platform.See Detail 3A. Joist Installation (Figure 4): Step 1 Extend bar hangers to fit between joist and position mounting tab locater lip tight to bottom of joist or framing member. Bar hangers should be level with bottom of joist or framing member. Step 2 Attach bar hangers to joist or framing member using appropriate hardware for material. Step 3 Adjust housing platform position by sliding back and forth on bar hangers to desired position. Housing may be locked into position See Detail 3A.Nail Supplied in hanger bars will be suitable. Score Lines 10" Safety Cable Bracket Hanger Bars Universal Butterfly Mounting Bracket 1/4" Hex Screw Mudding Ring Figure 1 Trim Mechanism Figure 2 INSTALLATION INSTRUCTIONS V90031 Avoid Fire or Electric Shock QUIET CEILING ROUND TRIM QCT900, QCM500 BASED SERIES Page 2 of 3 *Installation Instructions for qualified electricians only. *Install per National Electrical Code and local regulations. *Read Installation Instructions completely before installation. *Failure to follow Installation Instructions may void warranties. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. Rotational Adjustment Ring Lock Knob Optional Mudding Ring Fixture Mudding Frame Bracket Flathead Screw "T" Screw Ceiling Figure 3 Drywall Tape Fixture Gap Mudding Compound Ball Detent Catch Trim Mechanism Figure 5 DETAIL 3A DETAIL 4A Figure 4 9. Mudding Ring is sent unmounted from factory. Adjust Mudding Ring to applicable Ceiling thickness by aligning and securing to Fixture using applicable Mounting Hole Pattern as indicated by Ceiling Thickness Indicator Mark imprinted on Mudding Ring. See Detail 6A in Fig.6. 10. Secure Mudding Ring using four (4) #8-32 x 1/2 inch Flat head Screws (for 1/2 inch, 5/8 inch and 3/4 inch Ceiling thickness) or four (4) #8-32 x 3/4 inch Flat head Screws (for 1 inch Ceiling thickness). 11. Install Ceiling drywall up to Mudding Ring on Fixture so that the two (2) Mudding Frame Brackets contact inside of Ceiling. See Fig. 5. 12. Retain Fixture to Ceiling with one (1) Flathead Screw through each of two (2) Mudding Frame Brackets.See Fig. 5 13. Apply Drywall Tape and Mudding Compound to Mudding Ring overlapping Mudding Ring, Flathead Screws, Fixture Gap and surrounding area. Feather out Mudding Compound from Mudding Ring opening to surrounding ceiling area to produce a smooth, flat finish. See Fig. 5. INSTALLATION INSTRUCTIONS V90031 QUIET CEILING ROUND TRIM QCM900, QCM500 BASED SERIES Avoid Fire or Electric Shock Page 3 of 3 THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. *Installation Instructions for qualified electricians only. *Install per National Electrical Code and local regulations. *Read Installation Instructions completely before installation. *Failure to follow Installation Instructions may void warranties. 5/8" #8-32 Flathead Screw Detail 6A 23. Be careful to align Tab Alignment Feature on Trim Mechanism with Tab Alignment feature Notch in Rotational Adjustment Ring. 24. Connect Safety Cable attached to Trim to Fixture by inserting Safety Cable through opening in Fixture and inserting Snap Hook (See Fig. 1) on end of Safety Cable into hole in Bracket attached to inside of fixture.Install trim mechanism into fixture by pressing firmly to seat Ball detent catches.See Fig.5. Mudding Ring 3/4" Mounting Hole Pattern Rotational Adjustment Ring Figure 6 Tab Alignment Feature Notch 360 Rotational Lamp Adjustment IF LOCKING KNOB IS UNLOCKED: 14. Rotate Trim Mechanism to desired lamp bean position by turning Trim Mechanism up to 360 Degrees. 15. To lock positioning, remove Trim Mechanism being careful not to change position. 16. Tighten Lock Knob inside Fixture to lock Rotational adjustment Ring. See Fig.7. 17. Be careful to align Tab Alignment Feature on Trim Mechanism with Tab Alignment feature Notch in Rotational Adjustment Ring while installating trim after rotational adjustment. 18. Connect Safety Cable attached to Trim to Fixture by inserting Safety Cable through opening in Fixture and inserting Snap Hook (See Fig. 1) on end of Safety Cable into hole in Bracket attached to inside of fixture.Install trim mechanism into fixture by pressing firmly to seat Ball Detent Catches. See Fig.5. IF LOCKING KNOB IS LOCKED: 19. Remove Trim Mechanism from Fixture. 20. Loosen Lock Knob inside Fixture. 21. To lock positioning, remove Trim Mechanism being careful not to change position. 22. Tighten Lock Knob inside Fixture to lock Rotational adjustment Ring. See Fig.7. Ceiling Joist Locking Knob Fixture Figure 7 (Fixture Cover Removed For Clarity)