Document 13729678

advertisement
.
INSTALLATION INSTRUCTIONS
V90031
QUIET CEILING ROUND TRIM
QCT900, QCM500 BASED SERIES
Page 1 of 3
Avoid Fire or Electric Shock
THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.
*Installation Instructions for qualified electricians only.
*Install per National Electrical Code and local regulations.
*Read Installation Instructions completely before installation.
*Failure to follow Installation Instructions may void warranties.
Fixture Mounting:
8.
Butterfly Mounting (Commerical):
1.
Fixture comes equipped with Universal Mounting brackets and
can take common 1 inch or 1-1/2 inch Black Iron or
Galvanized Mounting Channels (Supplied By Others).
2.
Position Fixture so the Mounting Channels lie on top of ceiling
runners.
3.
Fasten Mounting Channels securely to ceiling runners.
4.
Secure Mounting channels to Universal Butterfly Mounting
Brackets with wire tire downs.
5.
Adjust elevation of Fixture so Mudding Ring Edge will be flush
with surface of finished Ceiling by loosening two (2) 1/4 inch
Hex Screws on both Universal Mounting Brackets. See Fig. 1.
6.
Tighten two (2) 1/4 inch Hex Screws on both Universal
Butterfly Mounting Brackets to secure Fixture. See Fig. 1.
Hanger Bar Mounting (Residential):
7.
Adjustable hanger bars are preassembled with mounting
bracket and provided with fixture.The preassembled hanger
bars must attached to the fixture prior to installation.Aligh with
two screws on end of fixture and tighten .Hanger bars are
installed in Fig.1.
Mounting Channel
(Supply by Others)
Fixture Housing
Cover
Hanger bars can be used with grid ceilings having T
bars and joist installations of wood.Adjustable hanger
bars are for use in installations with spacing from 10" to 24",
while maintaining minimum 1/2" spacing around fixture
For 10" Spacing,the hanger bar can be shorten by breaking
them at score line as shown in Fig.2.
Grid Ceiling Installation (Figure 3):
Step 1 Extend bar hangers between the T bars and slide the slots
in the mounting tabs over the T-bars.
Step 2 Adjust housing platform position by sliding back and
forth on bar hangers to desired position. Housing may be locked
in the position by tightening bar hanger locking screws on
housing platform.See Detail 3A.
Joist Installation (Figure 4):
Step 1 Extend bar hangers to fit between joist and position
mounting tab locater lip tight to bottom of joist or framing
member. Bar hangers should be level with bottom of joist
or framing member.
Step 2 Attach bar hangers to joist or framing member using
appropriate hardware for material.
Step 3 Adjust housing platform position by sliding back and
forth on bar hangers to desired position. Housing may be locked
into position See Detail 3A.Nail Supplied in hanger bars will be
suitable.
Score Lines
10"
Safety Cable
Bracket
Hanger Bars
Universal Butterfly
Mounting Bracket
1/4" Hex Screw
Mudding Ring
Figure 1
Trim Mechanism
Figure 2
INSTALLATION INSTRUCTIONS
V90031
Avoid Fire or Electric Shock
QUIET CEILING ROUND TRIM
QCT900, QCM500 BASED SERIES
Page 2 of 3
*Installation Instructions for qualified electricians only.
*Install per National Electrical Code and local regulations.
*Read Installation Instructions completely before installation.
*Failure to follow Installation Instructions may void warranties.
THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.
Rotational Adjustment Ring
Lock Knob
Optional
Mudding Ring
Fixture
Mudding Frame
Bracket
Flathead Screw
"T"
Screw
Ceiling
Figure 3
Drywall Tape
Fixture Gap
Mudding Compound
Ball Detent Catch
Trim Mechanism
Figure 5
DETAIL 3A
DETAIL 4A
Figure 4
9.
Mudding Ring is sent unmounted from factory.
Adjust Mudding Ring to applicable Ceiling thickness by
aligning and securing to Fixture using applicable Mounting
Hole Pattern as indicated by Ceiling Thickness Indicator Mark
imprinted on Mudding Ring. See Detail 6A in Fig.6.
10.
Secure Mudding Ring using four (4) #8-32 x 1/2 inch Flat
head Screws (for 1/2 inch, 5/8 inch and 3/4 inch Ceiling thickness)
or four (4) #8-32 x 3/4 inch Flat head Screws (for 1 inch Ceiling
thickness).
11.
Install Ceiling drywall up to Mudding Ring on Fixture
so that the two (2) Mudding Frame Brackets contact
inside of Ceiling. See Fig. 5.
12.
Retain Fixture to Ceiling with one (1) Flathead Screw
through each of two (2) Mudding Frame Brackets.See Fig. 5
13.
Apply Drywall Tape and Mudding Compound to Mudding
Ring overlapping Mudding Ring, Flathead Screws, Fixture
Gap and surrounding area. Feather out Mudding Compound
from Mudding Ring opening to surrounding ceiling area to
produce a smooth, flat finish. See Fig. 5.
INSTALLATION INSTRUCTIONS
V90031
QUIET CEILING ROUND TRIM
QCM900, QCM500 BASED SERIES
Avoid Fire or Electric Shock
Page 3 of 3
THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.
*Installation Instructions for qualified electricians only.
*Install per National Electrical Code and local regulations.
*Read Installation Instructions completely before installation.
*Failure to follow Installation Instructions may void warranties.
5/8"
#8-32 Flathead
Screw
Detail 6A
23.
Be careful to align Tab Alignment Feature on Trim Mechanism with
Tab Alignment feature Notch in Rotational
Adjustment Ring.
24.
Connect Safety Cable attached to Trim to Fixture by inserting Safety
Cable through opening in Fixture and inserting Snap Hook
(See Fig. 1) on end of Safety Cable into hole in Bracket attached to
inside of fixture.Install trim mechanism into fixture by pressing
firmly to seat Ball detent catches.See Fig.5.
Mudding Ring
3/4" Mounting
Hole Pattern
Rotational Adjustment Ring
Figure 6
Tab Alignment Feature Notch
360 Rotational Lamp Adjustment
IF LOCKING KNOB IS UNLOCKED:
14.
Rotate Trim Mechanism to desired lamp bean position by turning
Trim Mechanism up to 360 Degrees.
15.
To lock positioning, remove Trim Mechanism being careful not to
change position.
16.
Tighten Lock Knob inside Fixture to lock Rotational adjustment
Ring. See Fig.7.
17.
Be careful to align Tab Alignment Feature on Trim
Mechanism with Tab Alignment feature Notch in Rotational
Adjustment Ring while installating trim after rotational adjustment.
18.
Connect Safety Cable attached to Trim to Fixture by inserting Safety
Cable through opening in Fixture and inserting Snap Hook
(See Fig. 1) on end of Safety Cable into hole in Bracket attached to
inside of fixture.Install trim mechanism into fixture by pressing
firmly to seat Ball Detent Catches. See Fig.5.
IF LOCKING KNOB IS LOCKED:
19.
Remove Trim Mechanism from Fixture.
20.
Loosen Lock Knob inside Fixture.
21.
To lock positioning, remove Trim Mechanism being careful not to
change position.
22.
Tighten Lock Knob inside Fixture to lock Rotational adjustment
Ring. See Fig.7.
Ceiling Joist Locking Knob
Fixture
Figure 7
(Fixture Cover Removed For Clarity)
Download