D ES C R IPTION
The SkyBar™ high bay series reimagines high bay and low bay lighting
by delivering a unique aesthetic with industry-first uplight and leading
performance. By providing multiple lumen packages and distributions,
the SkyBar high bay gives the necessary optical freedom and flexibility
to meet the requirements for a wide variety of lighting applications.
SkyBlade high bay utilizes the advantages of the patented WaveStream™
technology to deliver a stylish LED alternative to traditional high bay
lighting for commercial and industrial applications.
Type
Catalog #
Project
Date
Comments
Prepared by
S PEC IFIC A TION FEA T U R E S
Available in 2-blade (17-1/2" x 503/8") and 4-blade (22-1/2" x 50-3/8")
configurations with PAF side rails
for rigidity. Decorative endplates
give an aesthetically pleasing
look and are attached with screws
for strength. The WaveStream
blades are retained with a clear
polycarbonate bracket which allow
them to be adjusted in the field.
to meet critical life-safety lighting
requirements. The 90-minute
batteries provide constant power
to the LED system, ensuring codecompliance. A test switch/indicator
button can be tested safely from
the ground using a laser pointer,
while the patented EZ Key prevents
accidental discharge of the battery
during construction. See ordering
information for details.
El e c t r i c a l
Co n tro l
Long-Life LED system coupled with
electrical driver to deliver optimal
performance. LED’s available in
3500K, 4000K or 5000k with a CRI
<85. Electronic drivers are available
for 120-277V, 347V and 480V
applications.
Equipped standard with a 0-10V
continuous dimming driver that
works with any standard 0-10V
control/dimmer. Dimming range
is 5% to 100%; varies by control
device. Combine with energysaving products like occupancy
sensors, daylighting controls, and
lighting relay panels from Cooper
Controls (www.coopercontrol.
com) to maximize energy savings.
Optional integrated sensor
Construction
Em e r g e n c y B a t t e r y P a ck Op tio n
Optional 120v-277v integral
emergency battery pack is
available in 7-watts or 14-watts
4-BLADE
provides occupancy detection.
Optics
Precision formed optical assembly
with positively retained high
optical grade acrylic lenses provide
a directed optical distribution using
WaveStream technology.
D river/A ccess
Tool-less driver access from below
the fixture.
Mounting
Suspended using two V-hangers
(included). Optional Y-hook,
Y-Toggle or Surface/stem mount
bracket is also available. Mounting
hardware must be ordered
separately.
SKYBAR
LED
17-1/2" X 50-3/8"
22-1/2" X 50-3/8"
Warranty
SkyBar features a five-year limited
warranty.
LED High Bay Luminaire
2-BLADE
3-3/8"
[86mm]
3-3/8"
[86mm]
5-7/8"
[150mm]
5-7/8"
[150mm]
22-1/2" [572mm]
D IN EM S ION TOP V IE W
17-1/2" [445mm]
COMPLIANCES
Luminaires are cULus listed for damp
Locations 1. 7°C-40°C (35°F-105°F)
ambient environments.
ROHS Compliant, and LED modules
comply with IESNA LM79/LM80
standards
E NE RGY DATA
4-BLADE (Shown with optional integrated sensor)
Catalog No.
22-1/2"
[572mm]
50-3/8" [1280mm]
2-BLADE (Shown with optional integrated sensor)
17-1/2"
[445mm]
50-3/8" [1280mm]
Input Watts
SKBLED-LD1-10
94
SKBLED-LD1-14
152
SKBLED-LD1-19
183
SKBLED-LD1-24
251
SKBLED-LD1-29
313
SH IP P ING DATA
Catalog No
SKBLED-LD1-10
SKBLED-LD1-14
SKBLED-LD1-19
SKBLED-LD1-24
SKBLED-LD1-29
Wt.
31 lbs.
31 lbs.
43 lbs.
43 lbs.
43 lbs.
Safe and convenient means of
disconnecting power
ADF131311
2016-02-18 11:15:32
S K B LE D
PH OTOM ETR IC S
60˚
3900
45˚
5850
0˚
15˚
30˚
Electronic Driver
Linear LED 4000K
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 1.6 x
mounting height
Lumens: 18964
Input Watts: 183
Efficacy: 105 lm/W
Test Report:
SKBLED-LD1-19-WUNV-L840-CD2-U
T
75˚
1950
SKBLED-LD1-19-WUNV-L840-CD2-U
Candela
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
90˚
Along II
4550
4528
4462
4352
4199
3998
3757
3468
3145
2786
2396
1990
1576
1179
831
557
353
195
71
45°
4550
4968
5134
5418
5496
5474
5276
4959
4537
4049
3556
3074
2618
2205
1834
1513
1228
941
647
Across
4550
5036
5513
5881
6066
6083
5829
5348
4734
4091
3484
2938
2460
2050
1710
1420
1144
881
622
75˚
3000
60˚
6000
45˚
9000
0˚
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
117
105
95
87
79
73
67
62
58
54
51
117
100
87
76
67
60
54
49
44
41
37
117
95
79
68
58
51
45
40
36
32
30
117
91
73
61
51
44
38
34
30
27
24
113
101
92
83
76
70
65
60
56
52
49
113
97
84
74
65
58
52
47
43
40
37
113
92
77
66
57
50
44
39
35
32
29
113
88
72
60
50
43
38
33
30
27
24
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
105
90
79
69
61
55
50
45
41
38
35
99
85
74
65
58
52
47
43
39
36
33
93
80
69
61
55
49
44
41
37
34
32
90
73
60
50
43
37
32
28
25
23
20
105
87
73
63
54
48
42
38
34
31
28
105
84
69
57
49
42
37
32
29
26
23
99
82
69
60
52
46
40
36
33
30
27
99
79
65
55
47
41
36
31
28
25
23
93
77
66
57
49
44
39
35
32
29
26
93
75
63
53
45
39
34
31
27
25
22
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Lumens
4412
7359
12783
17040
18964
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
5066
5049
4976
4843
4655
4410
4114
3758
3352
2903
2420
1928
1453
1031
687
432
258
136
46
Across
5066
5907
7382
8284
8463
8287
7410
6192
4986
4000
3218
2573
1938
1451
1058
752
483
279
137
45°
5066
5570
6459
7321
7680
7619
7253
6532
5644
4749
3893
3131
2483
1932
1420
1027
714
437
231
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
118
108
99
91
83
77
71
66
62
58
54
118
104
91
81
72
65
58
53
49
45
41
118 118
100 96
85 79
73 67
64 57
56 50
50 44
45 39
40 35
37 31
33 28
115
105
96
88
81
75
69
64
60
56
53
115
101
89
79
70
63
57
52
48
44
41
115
97
83
72
63
55
49
44
40
36
33
115
94
78
66
57
49
43
39
34
31
28
20%
50%
50 30 10
30%
50 30 10
50
109
96
85
75
67
61
55
50
46
42
39
103
91
81
72
65
58
53
48
44
41
38
98
87
77
69
62
56
51
47
43
40
37
109
93
80
69
61
54
48
43
39
36
33
109
90
75
64
55
48
43
38
34
31
28
103
89
77
67
59
52
47
42
38
35
32
103
86
73
63
54
47
42
37
34
30
28
10%
30 10
98
85
74
65
57
51
46
41
37
34
31
98
83
71
61
53
47
41
37
33
30
27
0%
0
95
81
69
59
51
44
39
35
31
28
26
Zonal Lumen Summary
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
0-180
30˚
Electronic Driver
Linear LED 4000K
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 1.6 x
mounting height
Lumens: 19152
Input Watts: 183
Efficacy: 105 lm/W
Test Report:
SKBLED-LD1-19-NUNV-L840-CD2-U
Candela
C o e f fi c i e n t s o f U t i l i z a t i o n
C o e f fi c i e n t s o f U t i l i z a t i o n
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
15˚
SKBLED-LD1-19-NUNV-L840-CD2-U
T
90˚
Zone
0-30
0-40
0-60
0-90
0-180
%Fixture
23.3
38.8
67.4
89.9
100.0
Lumens
5754
9410
15174
18272
19152
%Fixture
30.0
49.1
79.2
95.4
100.0
Metalux SkyBar-CCT Multiplier Table
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
CCT
Multipliers from 3500K
3500K
1.000
Multipliers from 4000K
0.0977
Multipliers from 5000K
0.0936
4000K
1.024
1.000
0.959
5000K
1.068
1.043
1.000
ADF131311
2016-02-18 11:15:32
S K B LE D
ORDER ING INFOR M A TION
SAMPLE NUMBER: SKBLED-LD1-14-W-UNV-L850-CD2-U
Series
SKBLED=WaveStream
High Bay
Lamp Type
LD1=LED 1.0
LED Lumen Output
2 Blades
10=10,000 Lumens
14=14,000 Lumens
4 Blades
19=19,000 Lumens
24=24,000 Lumens (5)
29=29,000 Lumens (5)
Distribution
N=Narrow
W=Wide
Voltage (1)
120V=120 Volt
277V=277 Volt
347V=347 Volt (4)
480V=480 Volt (4)
UNC=Universal Voltage
347-480 (4)
UNV=Universal Voltage
120-277
Options
Emergency
EL7W=7-watt, 120V-277V emergency
battery pack installed (6)
EL14W=14-watt 120V-277V emergency
battery pack installed (6)
GTD2=Bodine Generator Transfer Device (7)
ETS2=IOTA Emergency Transfer Switch (7)
Driver Type
CD=0-10V Dimming
Driver
5LT=Fifth Light
(DALI) Driver
Options
SVP3=Integrated occupancy dimming
sensor, 1200 sq. ft. coverage
MP=Modular Power
Receptacle (used for all
Cord or Cord and Plug
options) (2)
MSI=Fixture integrated 360° or
180° motion sensor installed
Packaging
U=Unit Pack
PALC=Job
Pack, in carton
Number of Drivers
1=1 Drivers (10,000 Lumens)
2=2 Drivers (14,000 and 19,000 Lumens)
4=4 Drivers (24,000 and 29,000 Lumens)
5LT
2=2 Drivers (10,000 Lumens)
4=4 Drivers (19,000 and 24,000 Lumens)
Accessories (order separately)
HBL-SPM=Single Monopoint Hanger w/Hub (3)
FH-1=Fixture Hook
FL-1=Fixture Loop
Y-TOGGLE=Y Mounting Toggle, #2 Cable
(Specify 10' or 30")
HBAYC-CHAIN/SET/U=(2) V-Hook Hangers, 36"
Chain Sets w/S-Hooks
MPC3=3' Modular Power Cord & Plug (Specify
Voltage)
MC6=6' Modular Power Cord
C6=120-277
PC6=120-277
ISHH-01=Programming Remote for Integrated Sensor
ISHH-02=Personal Control Remote for Integrated Sensor
CCT
L835=3500K
L840=4000K
L850=5000K
NOTES: (1)Voltage must be specified when ordered with plugs or emergency ballasts. (2)Requires use of MC or MPC cord accessories, specify voltage for plugs (MP). (3)Not available with UNC and EL options together.
(4)
UNC, 347V and 480V not available with switching in 10K, 14K, 19K. (5)EL not available with bi level switching. (6) With integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per
watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire under emergency operation available. (7) Used to transfer fixture to secondary
power source for life-safety operation. When used with a dimming fixture, two devices are required to ensure control is disabled while operating under emergency power.
Specifications and dimensions subject to change without notice. Consult your Eaton representative for availability and ordering information.
Product shipped in the “S” state, installer must rotate blades into position 1 or 2 to meet
DLC general highbay category.
Blades in position 1
Blades in position 2
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
ADF131311
2016-02-18 11:15:32
S K B LE D
INTEG R A TED S ENS OR
The SkyBar with Integrated Sensor technology provides automatic energy savings without sacrificing performance.
Traditionally these types of energy savings required coordination between the luminaire and a lighting control system.
The SkyBar delivers superior lighting with integrated occupancy controls.
Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for
new construction or retrofit the SkyBar delivers automatic ON to an energy saving light level, while turned OFF when
the space is unoccupied.
Occupied light levels and unoccupied light levels can be adjusted using the integrated sensor programming
remote (Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog Number: ISHH-02)
provides code compliant manual raise, lower, ON, OFF control.
The SkyBar with Integrated Sensor is easy to install with no special wiring and ensures energy savings
out-of-the-box with default control settings.
How i t w o r k s :
• As the user enters the space controlled by the integral sensor, the lighting turns ON to full light
output. This can be changed using the optional remote.
• Lighting will remain at that the occupied level until the space is unoccupied. This will start the
occupancy timeout period (default 20 minutes).
• If the space remains unoccupied for half of the timeout period, the lighting will automatically
reduce to the Energy Saver light level. This adjustable light level is typically half of the
occupied level.
• At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level
uses the OFF default setting.
(OCC)
Occupied Level
(OCC)
Occupied Level
Energy Savings
Opportunities
Light Level
100
(ES)
Energy Saver
Light Level
0
Timeout Value
Unoccupied
Occupied
(UNOCC)
Unoccupied Level
Unoccupied
S VPD 3 C o v e r a g e P a t te rn
Occupied
Optional Remote
C ontrols
Side View
0
SE
T
75
6.1m
[20 ft.]
1.
3.
12.2m 9.1m 6.1m 3m
[40 ft.] [30 ft.] [20 ft.] [10 ft.]
0
3m 6.1m 9.1m 12.2m
[10 ft.] [20 ft.] [30 ft.] [40 ft.]
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
Pr
o
gr
am
IS
H
To
S
Ra et
O
is
50
M
AX
5
2. 0, 7 e, L utp
To
5, ow
ut
Se save Max er o
rP
lec
.
re
t O pres
ss
s
cc
M
or SET
in.
Un
Oc
c
U
Oc n
c
R
Lo ais e
we /
r
5
LO
M
IN
9.1m
[30 ft.]
R
Lo aise
we /
r
M
AX
10
HI
75
15
ES
50
20
Oc
Oc
c
To
IS
ISHH-01 Remote
Se
M
c
ES
Pre
Th ss th lec
tS
e
st o li g e S
C E ce
h ti
re
n
N
d
li g n g w E b e s
ht
u
i
lev ll a d tt on
els
ju st .
..
to
Pe
m
ing
H- Remo
01 te
SC
EN
E
Tim
Ou e
t
IN
U
Oc n
c
rso
na
HH l Rem
-0 o te
2
ISHH-02 Remote
ADF131311
2016-02-18 11:15:32
Download