The LumaWatt Outdoor Wireless System automates light levels while

advertisement
D ES C R IPTION
The LumaWatt Outdoor Wireless System automates light levels while
metering and reporting system performance, enabling compliance to
energy saving codes and standards. The LumaWatt System is simple to
implement and offers flexible automation options. Sensors are factory
installed in every luminaire for reliability, saving installation time.
Type
Catalog #
Project
Date
Comments
Prepared by
S PEC IFIC A TION FEA T U R E S
Ov e r v i e w
The LumaWatt System is a
peer-to-peer wireless network
of luminaire integrated sensors
that operate in accordance with
stored programmable profiles.
Each sensor is capable of; motion
and photo sensing, metering
power consumption and wireless
communication. Sensor profiles
dictate how the individual
luminaires operate as well as how
it functions within a group. The
end user can create and manage
sensor profiles with web-based
management software and update
sensors via wireless gateways. The
sensor will operate in accordance
to its last-loaded profile, regardless
of network availability.
Fea t u r e s
The LumaWatt software resides
on the locally installed energy
management server. The energy
management software can be
accessed via a web portal by
providing remote access with
web browser capable devices.
Sensor operation is monitored and
reported to verify and document
luminaire performance. Power
is metered, in real-time, to 2%
accuracy. System reliability is
enhanced by failure detection and
notification.
The energy management server
is scalable, addressing up to ten
gateways, each of which can
address an additional 300 sensors,
for up to total system capacity
of 1,000 sensors per energy
management server.
The Router connects to the server
and powers Gateways through
48V PoE (power-over-ethernet)
connections using CAT5 cable.
Gateways communicate to sensors
at a radio frequency of 2405-2480
MHz using the 2.4Hz ISM band
128-bit AES encryption security.
Sensors and gateways can
communicate when within 300’,
line-of-site of each other, without
obstructions.
Factory installed sensors control
luminaire output ON/OFF or dim
in 1% increments. Sensors can be
configured for up to nine events
daily, based on a combination of
time scheduling, photo sensing,
or motion detection. Operational
modes define ramp-up times,
length of operation on occupancy
detection, sensitivity to motion and
ambient light, including dimming
level for each event.
The LumaWatt System is designed
to minimize installation and
commissioning time. Luminaire
commissioning data is discovered
and analyzed by the energy
management software to prepare
for geographic location of
luminaire control icons on site
plans. Hardware self-diagnostics
assist in troubleshooting network
issues.
Op tion al E n closu re
The optional enclosure houses
the LumaWatt gateway or energy
management server and up
to two routers for installation
convenience. Enclosures are
recommended when installing
components outdoors or when
security is needed.
Warran ty
Five-year warranty.
D IMENS IONS
ENERGY MANAGEMENT SERVER (RF-EM-1)
GATEWAY (RF-GW-1)
5"
[127mm]
7"
[178mm]
LUMAWATT
OUTDOOR
WIRELESS
SYSTEM
3"
[76mm]
1/2"
[13mm]
10" [254mm]
4" [102mm]
1-1/4"
[32mm]
WIRELESS CONTROL AND
MONITORING SYSTEM
ROUTER (RF-ROUT-1)
CERTIFICATION DATA
4"
[102mm]
1-1/4"
[32mm]
9-1/4" [235mm]
FCC Part 15 Class A
RoHS
UL and cUL Listed
CE Certified
IEEE 802.15.4 Compliant
SHIPPING DATA
Approximate Net Weight:
LumaWatt Server: 2.3 lbs. (1.04 kgs.)
Gateway: 0.3 lbs. (0.13 kgs.)
Router: 1.7 lbs. (0.77 kgs.)
Enclosure: 38 lbs. (17.3 kgs.)
Luminaire Sensor: 0.2 lbs. (0.09 kgs.)
TD512002EN
2015-12-01 11:58:30
L U M A W A TT OUT D OOR W I R EL ES S S Y S TEM
OCCUPA NC Y S ENS OR D E T E C T I O N P AT T E R N S
For Mounting Heights from 8' up to 16'
15
0
10
5
0
5
10
8
15
12
9
4
0
4
9
12
Coverage Top Area (Feet)
Coverage Side Area (Feet)
For Mounting Heights from 16' up to 40'
0
40
30
20
10
0
20
10
20
30
30
40
40
40
30
20
10
0
10
20
30
40
Coverage Top Area (Feet)
Coverage Side Area (Feet)
S ENSOR OPTION
S Y S T E M C O N F I G URA T IONS
LUMINAIRE SENSOR
RF-EM-1
Connects up to10 RF-GW-1
(1,000 Sensors Maximum)
RF-ROUT-1
Connects up to four RF-GW-1
Luminaire Sensor
Factory Installed
One per Luminaire
120V AC
3-1/2" [89mm]
RF-GW-1
Connects up to
300 Sensors
CAT5 Cable (330' maximum)
Optional Components
1-3/16"
3/4"
[19mm] [30mm]
S Y S TEM OR D ER ING INFO R M AT I O N
Product Family
Components 1
Options
Accessories (Order Separately)
RF=LumaWatt
Outdoor
Wireless
System
EM-1=Energy Management
Server 2, 3
GW-1=Gateway 4, 5
ROUT-1=Router 2, 6
ENC3R=NEMA 3R Rated Enclosure 1, 7
RFSEN1LWBZ=Wide Distribution Replacement Luminaire Sensor Finished in Bronze 8
RFSEN1LWWH=Wide Distribution Replacement Luminaire Sensor Finished in White 8
RFSEN1LNBZ=Narrow Distribution Replacement Luminaire Sensor Finished in Bronze 8
RFSEN1LNWH=Narrow Distribution Replacement Luminaire Sensor Finished in White 8
RFPP1=Replacement Fixture Power Pack
Luminaire Sensor (Add as Suffix)
DIMRF-LW=LumaWatt Wireless Sensor,
Wide Lens for 8'-16' Mounting
DIMRF-LN=LumaWatt Wireless Sensor,
Narrow Lens for 16'-40' Mounting
NOTES:
1 Minimum system requires RF-EM-1, RF-GW-1, and RF-ROUT-1.
2. 120 VAC, 50/60 Hz only.
3. Maximum of ten gateways per energy management server. System maximum of 1,000 sensors.
4. Sensors and gateways communicate up to 300' LOS. Maximum 300 sensor per gateway.
5. Connect an appropriate length CAT5 ethernet cable (maximum length 330') to the router PoE (power-over-ethernet) port (ports 1 thru 4). The gateway should be placed on the interior of an exterior building wall, within 150' of
one luminaire.
6. Maximum of four gateways per router.
7. ENC3R enclosure consists of, factory installed: RF-EM-1, RF-GW-1, or RF-ROUT-1, see optional components for ordering details. Suitable for 40°C Ambient temperatures. Rated for outdoor use.
8. Factory installed replacement only. See luminaire specification sheet for more information.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
TD512002EN
2015-12-01 11:58:30
L U M A W A TT OUT D OOR W I R EL ES S S Y S TEM
OPTION A L C OM PONENTS
GATEWAY ENCLOSURE (ENC3R-1G)
LARGE ENCLOSURE
11-5/8"
[295mm]
20"
[508mm]
9-3/8"
[239mm]
16"
[406mm]
6"
[152mm]
ENCL OSUR E OR D ER ING I N F O R M AT I O N
Sample Number: ENC3R-1EM-8P-120V
Product Family
Components
Number of Switch Ports
Voltage
ENC3R=NEMA 3R Rated Enclosure
Energy Manager
0EM=No Energy Manager
1EM=Energy Manager Installed
8P=8-Port Network Switch 2
120V=120V
Gateway
1G=Gateway 1
NOTES:
1. Installed in gateway enclosure.
2. High ambient 8-port switch is standard when ordering enclosures.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
TD512002EN
2015-12-01 11:58:30
Download