D ES C R IPTION The LumaWatt Outdoor Wireless System automates light levels while metering and reporting system performance, enabling compliance to energy saving codes and standards. The LumaWatt System is simple to implement and offers flexible automation options. Sensors are factory installed in every luminaire for reliability, saving installation time. Type Catalog # Project Date Comments Prepared by S PEC IFIC A TION FEA T U R E S Ov e r v i e w The LumaWatt System is a peer-to-peer wireless network of luminaire integrated sensors that operate in accordance with stored programmable profiles. Each sensor is capable of; motion and photo sensing, metering power consumption and wireless communication. Sensor profiles dictate how the individual luminaires operate as well as how it functions within a group. The end user can create and manage sensor profiles with web-based management software and update sensors via wireless gateways. The sensor will operate in accordance to its last-loaded profile, regardless of network availability. Fea t u r e s The LumaWatt software resides on the locally installed energy management server. The energy management software can be accessed via a web portal by providing remote access with web browser capable devices. Sensor operation is monitored and reported to verify and document luminaire performance. Power is metered, in real-time, to 2% accuracy. System reliability is enhanced by failure detection and notification. The energy management server is scalable, addressing up to ten gateways, each of which can address an additional 300 sensors, for up to total system capacity of 1,000 sensors per energy management server. The Router connects to the server and powers Gateways through 48V PoE (power-over-ethernet) connections using CAT5 cable. Gateways communicate to sensors at a radio frequency of 2405-2480 MHz using the 2.4Hz ISM band 128-bit AES encryption security. Sensors and gateways can communicate when within 300’, line-of-site of each other, without obstructions. Factory installed sensors control luminaire output ON/OFF or dim in 1% increments. Sensors can be configured for up to nine events daily, based on a combination of time scheduling, photo sensing, or motion detection. Operational modes define ramp-up times, length of operation on occupancy detection, sensitivity to motion and ambient light, including dimming level for each event. The LumaWatt System is designed to minimize installation and commissioning time. Luminaire commissioning data is discovered and analyzed by the energy management software to prepare for geographic location of luminaire control icons on site plans. Hardware self-diagnostics assist in troubleshooting network issues. Op tion al E n closu re The optional enclosure houses the LumaWatt gateway or energy management server and up to two routers for installation convenience. Enclosures are recommended when installing components outdoors or when security is needed. Warran ty Five-year warranty. D IMENS IONS ENERGY MANAGEMENT SERVER (RF-EM-1) GATEWAY (RF-GW-1) 5" [127mm] 7" [178mm] LUMAWATT OUTDOOR WIRELESS SYSTEM 3" [76mm] 1/2" [13mm] 10" [254mm] 4" [102mm] 1-1/4" [32mm] WIRELESS CONTROL AND MONITORING SYSTEM ROUTER (RF-ROUT-1) CERTIFICATION DATA 4" [102mm] 1-1/4" [32mm] 9-1/4" [235mm] FCC Part 15 Class A RoHS UL and cUL Listed CE Certified IEEE 802.15.4 Compliant SHIPPING DATA Approximate Net Weight: LumaWatt Server: 2.3 lbs. (1.04 kgs.) Gateway: 0.3 lbs. (0.13 kgs.) Router: 1.7 lbs. (0.77 kgs.) Enclosure: 38 lbs. (17.3 kgs.) Luminaire Sensor: 0.2 lbs. (0.09 kgs.) TD512002EN 2015-12-01 11:58:30 L U M A W A TT OUT D OOR W I R EL ES S S Y S TEM OCCUPA NC Y S ENS OR D E T E C T I O N P AT T E R N S For Mounting Heights from 8' up to 16' 15 0 10 5 0 5 10 8 15 12 9 4 0 4 9 12 Coverage Top Area (Feet) Coverage Side Area (Feet) For Mounting Heights from 16' up to 40' 0 40 30 20 10 0 20 10 20 30 30 40 40 40 30 20 10 0 10 20 30 40 Coverage Top Area (Feet) Coverage Side Area (Feet) S ENSOR OPTION S Y S T E M C O N F I G URA T IONS LUMINAIRE SENSOR RF-EM-1 Connects up to10 RF-GW-1 (1,000 Sensors Maximum) RF-ROUT-1 Connects up to four RF-GW-1 Luminaire Sensor Factory Installed One per Luminaire 120V AC 3-1/2" [89mm] RF-GW-1 Connects up to 300 Sensors CAT5 Cable (330' maximum) Optional Components 1-3/16" 3/4" [19mm] [30mm] S Y S TEM OR D ER ING INFO R M AT I O N Product Family Components 1 Options Accessories (Order Separately) RF=LumaWatt Outdoor Wireless System EM-1=Energy Management Server 2, 3 GW-1=Gateway 4, 5 ROUT-1=Router 2, 6 ENC3R=NEMA 3R Rated Enclosure 1, 7 RFSEN1LWBZ=Wide Distribution Replacement Luminaire Sensor Finished in Bronze 8 RFSEN1LWWH=Wide Distribution Replacement Luminaire Sensor Finished in White 8 RFSEN1LNBZ=Narrow Distribution Replacement Luminaire Sensor Finished in Bronze 8 RFSEN1LNWH=Narrow Distribution Replacement Luminaire Sensor Finished in White 8 RFPP1=Replacement Fixture Power Pack Luminaire Sensor (Add as Suffix) DIMRF-LW=LumaWatt Wireless Sensor, Wide Lens for 8'-16' Mounting DIMRF-LN=LumaWatt Wireless Sensor, Narrow Lens for 16'-40' Mounting NOTES: 1 Minimum system requires RF-EM-1, RF-GW-1, and RF-ROUT-1. 2. 120 VAC, 50/60 Hz only. 3. Maximum of ten gateways per energy management server. System maximum of 1,000 sensors. 4. Sensors and gateways communicate up to 300' LOS. Maximum 300 sensor per gateway. 5. Connect an appropriate length CAT5 ethernet cable (maximum length 330') to the router PoE (power-over-ethernet) port (ports 1 thru 4). The gateway should be placed on the interior of an exterior building wall, within 150' of one luminaire. 6. Maximum of four gateways per router. 7. ENC3R enclosure consists of, factory installed: RF-EM-1, RF-GW-1, or RF-ROUT-1, see optional components for ordering details. Suitable for 40°C Ambient temperatures. Rated for outdoor use. 8. Factory installed replacement only. See luminaire specification sheet for more information. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. TD512002EN 2015-12-01 11:58:30 L U M A W A TT OUT D OOR W I R EL ES S S Y S TEM OPTION A L C OM PONENTS GATEWAY ENCLOSURE (ENC3R-1G) LARGE ENCLOSURE 11-5/8" [295mm] 20" [508mm] 9-3/8" [239mm] 16" [406mm] 6" [152mm] ENCL OSUR E OR D ER ING I N F O R M AT I O N Sample Number: ENC3R-1EM-8P-120V Product Family Components Number of Switch Ports Voltage ENC3R=NEMA 3R Rated Enclosure Energy Manager 0EM=No Energy Manager 1EM=Energy Manager Installed 8P=8-Port Network Switch 2 120V=120V Gateway 1G=Gateway 1 NOTES: 1. Installed in gateway enclosure. 2. High ambient 8-port switch is standard when ordering enclosures. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. TD512002EN 2015-12-01 11:58:30