TM Mesa INSTALLATION INSTRUCTIONS IMPORTANT: Read carefully before installing fixture. Retain for future reference. General: Upon receipt of fixture thoroughly inspect for any freight damage, which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct merchandise. Sheet 1 of 3 3/10/04 IMI-574 Safety: This fixture must be wired in accordance with the national electrical code and applicable local codes and ordinance. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation section. All work should be done by a qualified electrician. WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing. NOTE: A 3”-OD tenon structure is required for both single and double post mount fixtures. A. To post mount a single fixture. A1. Loosen the captive screw and take off the cap shown in Fig. A1. A2. Pull supply wires from post through the hole originally covered by the cap. A3. Pull all leads from fixture out of the same hole. A4. Slip fit the fixture onto the tenon. A5. Rotate the fixture to desired position. A6. Tighten all four (4) 3/8-16 set screws (provided) to approximately 215 in/lbs. Over tightening screws may cause fixture damage. A7. Connect leads properly. A8. Push wires back into the hole. A9. Close the hole with cap and tighten the captive screw to seal the hole. B. To post mount double fixtures with arm B1. Loosen the captive screw and take off the cap shown in Fig. B1. B2. Pull supply wires from post through the hole originally covered by the cap. B3. Pull all leads from post and both arm wings out of the hole. B4. Slip fit the arm onto the tenon. B5. Rotate the arm to desired position. B6. Tighten all eight (8) 3/8-16 set screws (provided) to approximately 215 in/lbs. Over tightening screws may cause arm damage. B7. Connect leads properly. B8. Push wires back into the hole. B9. Repeat steps A1 through A9 above to mount both fixtures onto the arm, one on each wing. B10.Close the hole with cap and tighten the captive screw to seal the hole. CAP FIG. A CAP FIG. B These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative. Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-574 AVU040082 TM Mesa INSTALLATION INSTRUCTIONS IMPORTANT: Read carefully before installing fixture. Retain for future reference. Sheet 2 of 3 3/10/04 IMI-574 WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing. C. To wall mount a fixture with arm, C1. Using wall mount plate as a template, drill six (6) holes in wall. Install appropriate wall anchors (not supplied). Silicone caulk around junction box and wall anchors. Secure wall mount plate to wall with six (6) 1/2-13 x 1-1/2 long bolts and six (6) lockwashers. Torque bolts to 450 in/lbs. C2. Extend supply wires from junction box to minimum 3 feet in length. C3. Pull extended supply wires through arm and hook the arm over installed wall mount plate. C4. Secure the arm by tightening the set screw on bottom to approximately 215 in/lbs toward wall mount plate. C5. Repeat steps A1 through A9 above to mount fixture onto the arm. WALL MOUNT PLATE J-BOX LOCKWASHERS BOLTS WALL MOUNT ARM 1" SET SCREW WALL ANCHORS WALL FIG. C D. To relamp, D1. Loosen all four (4) captive screws at locations shown in Fig. D1 until disengaged inside. D2. On top of fixture, look for an arrow sign and word “OPEN HERE”. Open the top firmly and slowly from this location. D3. ENGAGE THE HINGE LOCK as shown in Fig. D2. Failure to engage the hinge may cause injury. D4. Rotate all four (4) U-shape brackets to unlock the reflector. D5. Remove the reflector. D6. Relamp. Make sure that the old lamp is cool before relamp. D7. Reposition the reflector. D8. Rotate all four (4) brackets to lock the reflector. Hand tighten each thumb screw on bracket if it is loose. D9. Hold the top firmly and DISENGAGE THE HINGE LOCK as shown in Fig. D2. Failure to disengage the hinge will cause hinge damage. D10. Close the top slowly. D11. Tighten back all four (4) captive screws. SCREWS BOTTOM VIEW FIG. D1 These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative. Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-574 AVU040082 TM Mesa INSTALLATION INSTRUCTIONS IMPORTANT: Read carefully before installing fixture. Retain for future reference. Sheet 3 of 3 3/10/04 IMI-574 WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing. ENGAGE TO KEEP DOOR OPEN DISENGAGE TO CLOSE DOOR FIG. D2 E. To replace the ballast tray, E1. Open the top of fixture as described in D1 through D3. E2. Disconnect the ballast tray completely by disengaging all connectors in the fixture. E3. Disengage all three (3) wing head screws on the tray from the housing. E4. Remove the tray using the handle on top of the tray. E5. Place new tray back, align bottom edge to the channel and all three (3) wing head screws to receptacles on housing. Tighten three (3) screws evenly. E6. Re-connect all connectors that were previously disconnected. E7. Close the top as described in D9 through D11. WING HEAD SCREWS FIG. E These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative. Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-574 AVU040082