Catalog # Type

advertisement
NEO-RAY
DESCRIPTION
Provocative, discrete, vertical illumination, the right light, directed to the
right place, easy to see by, and easy to read by. Straight and narrow rows of
radiant fins, in perfect array, send highly efficient vertical light cascading
between book stacks or anywhere you direct it. The illuminated fins are
white, the housing finished to blend or accentuate.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Construction
20-guage steel housing. Nominal
3', 4', 6' or 8' illuminated sections.
B ... Shielding
Lateral baffle.
A B
C ... Electrical
120, 277, 347 or Universal Voltage
electronic ballast. Fixtures and
electrical components certified to
UL and CUL standards.
C
D ... Finish
Durable, low gloss, white, powder
coated acrylic finish.
Mounting
2DP; Pendant with single stem
(standard) or single cable. Canopy:
Round 5-1/2" diameter.
D
2S/DP
2-S
1 & 2T8
5"
[127mm]
Specialty
Suspended Stack Light
Direct
4" [102mm]
Light Distribution:
6" [152mm]
Indirect - 7.5%
Direct - 92.5%
1"
2"
2"
36" [914mm]; 48" [1219mm];
72" [1829mm]; 96" [2438mm]
ORDERING INFORMATION
Sample Number: 2SDP-1T8-ST-8-1EB-SI-S14
Series
2S=Specialty
Mounting
P=Pendant
Lamp Type
T8=T8
Pendant
SC12=12" Single Cable
Voltage
1=120V
Light Output
D=Direct
Number of Lamps
T5=T5
T5HO=T5HO
SC15=15" Single Cable
SC18=18" Single Cable
2=277V
3=347V
SC21=21" Single Cable
SC24=24" Single Cable
U=Universal
(Not included)
1=1 Lamp
2=2 Lamps
SC48=48" Single Cable
ST24=24" Single Stem
ST36=36" Single Stem
ST48=48" Single Stem
Run Length
Overall Nominal Run Length
___ ft.
Notes: 1
1
Ballast
EB=Electronic Ballast
(Standard)
DB=Dimming Ballast
Emergency
EM=Emergency Pack
(Consult Factory)
Fusing
GLR=GLR
GMF=GMF
Shielding
S14=Contoured Baffle
Specifications and Dimensions subject to change without notice.
Not all options available. Please consult your Cooper Lighting Representative for availability.
Consult your representative for additional options and finishes.
ADN041948
02/09/2010 9:24:54 AM
Neoray 2S/DP, 2S
PHOTOMETRICS
180 °
135 °
Coefficients of Utilization
Effective floor cavity reflectance
80%
50%
rc
rw
RCR
1
2
3
4
5
90°
90°
0°
6
7
8
9
10
45 °
45 °
0°
2S/DP
(1) F40T12/RS/WW
3200 Lumens
Efficiency 68.2%
Test Report
#2/S 4FT for Cat No. 2S
Candela
20%
30%
70
50 30
10
50 30 10
50 30 10
56
51
54 52 50
48 45 42
41 40 39
37 35 33
34 33 32
31 29 28
47
44
40
37
43
38
34
31
39
34
30
27
36
31
27
24
33
30
27
25
31
27
24
22
29
25
22
20
28
25
23
21
26
23
21
19
25
22
19
17
35
32
30
28
28
26
23
21
24
21
19
17
21
19
16
15
22
20
19
17
20
18
16
14
17
16
14
12
19
17
16
14
17
15
14
12
15
14
12
11
Zonal Lumen Summary
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
499
788
1332
15.6
24.6
41.6
22.9
36.1
61.0
0-90
90-180
0-180
2019
164
2183
63.1
5.1
68.2
92.5
7.5
100.0
Angle
0
5
Along II
686
686
45°
686
692
Across ⊥
686
699
15
25
590
464
630
540
686
654
35
45
55
65
332
183
99
60
439
330
279
242
629
580
559
522
75
85
90
35
8
3
247
171
117
487
330
208
95
100
115
125
4
3
0
0
90
58
31
18
146
78
5
4
135
145
155
165
175
0
0
0
0
0
6
0
0
0
0
0
0
0
0
0
180
0
0
0
Total Luminaire Efficiency = 68.2%
MOUNTING INFORMATION
MOUNTING
5"
26"
5"
5"
36"
38"
5"
5"
48"
62"
5"
5"
86"
72"
5"
96"
(INDIVIDUAL FIXTURES ONLY)
CONSULT FACTORY FOR CONTINUOUS
RUN APPLICATIONS
TYPICAL STEM LOCATIONS
BEGINNING OF RUN
5"
8' BOR - (86")
6' BOR - (62")
4' BOR - (38")
3' BOR - (26")
INTERMEDIATE FIXTURE
8' INT - (96")
6' INT - (72")
4' INT - (48")
3' INT - (36")
END OF RUN
8' EOR - (96")
6' EOR - (72")
4' EOR - (48")
3' EOR - (36")
5"
OVERALL LENGTH OF RUN
SHIELDING INFORMATION
S14 Baffle
2” on center, 25˚ cutoff.
Specifications and Dimensions subject to change without notice.
Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADN041948
02/09/2010 9:24:54 AM
Download