NEO-RAY DESCRIPTION Provocative, discrete, vertical illumination, the right light, directed to the right place, easy to see by, and easy to read by. Straight and narrow rows of radiant fins, in perfect array, send highly efficient vertical light cascading between book stacks or anywhere you direct it. The illuminated fins are white, the housing finished to blend or accentuate. Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES A ... Construction 20-guage steel housing. Nominal 3', 4', 6' or 8' illuminated sections. B ... Shielding Lateral baffle. A B C ... Electrical 120, 277, 347 or Universal Voltage electronic ballast. Fixtures and electrical components certified to UL and CUL standards. C D ... Finish Durable, low gloss, white, powder coated acrylic finish. Mounting 2DP; Pendant with single stem (standard) or single cable. Canopy: Round 5-1/2" diameter. D 2S/DP 2-S 1 & 2T8 5" [127mm] Specialty Suspended Stack Light Direct 4" [102mm] Light Distribution: 6" [152mm] Indirect - 7.5% Direct - 92.5% 1" 2" 2" 36" [914mm]; 48" [1219mm]; 72" [1829mm]; 96" [2438mm] ORDERING INFORMATION Sample Number: 2SDP-1T8-ST-8-1EB-SI-S14 Series 2S=Specialty Mounting P=Pendant Lamp Type T8=T8 Pendant SC12=12" Single Cable Voltage 1=120V Light Output D=Direct Number of Lamps T5=T5 T5HO=T5HO SC15=15" Single Cable SC18=18" Single Cable 2=277V 3=347V SC21=21" Single Cable SC24=24" Single Cable U=Universal (Not included) 1=1 Lamp 2=2 Lamps SC48=48" Single Cable ST24=24" Single Stem ST36=36" Single Stem ST48=48" Single Stem Run Length Overall Nominal Run Length ___ ft. Notes: 1 1 Ballast EB=Electronic Ballast (Standard) DB=Dimming Ballast Emergency EM=Emergency Pack (Consult Factory) Fusing GLR=GLR GMF=GMF Shielding S14=Contoured Baffle Specifications and Dimensions subject to change without notice. Not all options available. Please consult your Cooper Lighting Representative for availability. Consult your representative for additional options and finishes. ADN041948 02/09/2010 9:24:54 AM Neoray 2S/DP, 2S PHOTOMETRICS 180 ° 135 ° Coefficients of Utilization Effective floor cavity reflectance 80% 50% rc rw RCR 1 2 3 4 5 90° 90° 0° 6 7 8 9 10 45 ° 45 ° 0° 2S/DP (1) F40T12/RS/WW 3200 Lumens Efficiency 68.2% Test Report #2/S 4FT for Cat No. 2S Candela 20% 30% 70 50 30 10 50 30 10 50 30 10 56 51 54 52 50 48 45 42 41 40 39 37 35 33 34 33 32 31 29 28 47 44 40 37 43 38 34 31 39 34 30 27 36 31 27 24 33 30 27 25 31 27 24 22 29 25 22 20 28 25 23 21 26 23 21 19 25 22 19 17 35 32 30 28 28 26 23 21 24 21 19 17 21 19 16 15 22 20 19 17 20 18 16 14 17 16 14 12 19 17 16 14 17 15 14 12 15 14 12 11 Zonal Lumen Summary Zone Lumens %Lamp %Fixture 0-30 0-40 0-60 499 788 1332 15.6 24.6 41.6 22.9 36.1 61.0 0-90 90-180 0-180 2019 164 2183 63.1 5.1 68.2 92.5 7.5 100.0 Angle 0 5 Along II 686 686 45° 686 692 Across ⊥ 686 699 15 25 590 464 630 540 686 654 35 45 55 65 332 183 99 60 439 330 279 242 629 580 559 522 75 85 90 35 8 3 247 171 117 487 330 208 95 100 115 125 4 3 0 0 90 58 31 18 146 78 5 4 135 145 155 165 175 0 0 0 0 0 6 0 0 0 0 0 0 0 0 0 180 0 0 0 Total Luminaire Efficiency = 68.2% MOUNTING INFORMATION MOUNTING 5" 26" 5" 5" 36" 38" 5" 5" 48" 62" 5" 5" 86" 72" 5" 96" (INDIVIDUAL FIXTURES ONLY) CONSULT FACTORY FOR CONTINUOUS RUN APPLICATIONS TYPICAL STEM LOCATIONS BEGINNING OF RUN 5" 8' BOR - (86") 6' BOR - (62") 4' BOR - (38") 3' BOR - (26") INTERMEDIATE FIXTURE 8' INT - (96") 6' INT - (72") 4' INT - (48") 3' INT - (36") END OF RUN 8' EOR - (96") 6' EOR - (72") 4' EOR - (48") 3' EOR - (36") 5" OVERALL LENGTH OF RUN SHIELDING INFORMATION S14 Baffle 2” on center, 25˚ cutoff. Specifications and Dimensions subject to change without notice. Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADN041948 02/09/2010 9:24:54 AM