Catalog # Type

advertisement
CORELITE
DESCRIPTION
Corelite's Class A Indirect suspended fluorescent luminaire combines classic
design with contemporary styling perfect for today's interiors. The
engineered optical system provides a widespread uplight distribution for
excellent ceiling uniformity and wide row spacing. Class A Indirect may be
mounted individually or continuously with 4', 8' and 12' modular sections.
Luminaires align with T-Grid and interface with all ceiling types. Class A
Indirect is best suited for opens offices, private offices, conference rooms,
corridors, schools, libraries, labs and public spaces.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Construction
Housing is one piece die-formed
20-gauge cold rolled steel, forming
a 9" x 2 7/8" architectural profile.
Standard 4'-0", 8'-0", and 12'-0"
fixture lengths combine for
continuous runs.
B ... End Plates
Standard laser cut 14-gauge cold
rolled steel, mechanically attached
with no exposed fasteners.
Optional die-cast aluminum end
caps also available.
A C
C ... Reflectors
Reflector pan is painted with a high
reflectance white powder coat
finish. Optional die-formed side
reflectors are highly specular
anodized aluminum.
D ... Electrical
Fixtures are prewired with quick
wire connectors and use UL listed
Class P, 265ma T8 instant start
universal voltage electronic
ballasts. Power factor of 95% with
less than 10% THD. Fixtures and
electrical components certified to
UL and CUL standards.
D
E ... Finish
Fixture housings are standard
white using electrostatically
applied polyester powder coat
paint.
Mounting
Standard aircraft cable mounts on
4'-0", 8'-0" and 12'-0" centers. Refer
to installation section for various
ceiling interface details and rigid
pendant mounting details.
B
E
2-7/8"
[73mm]
F LAT E ND P LAT E (S tandard)
9" [229mm]
1/8"
[3mm]
C enter Lamp Angled
Class A
Indirect
E T =T AP E R E D E ND C AP
MO DUL E S
AND
DIME NS IO NS *
3T8
5"
[127mm]
48" [1219mm]
Suspended
96" [2438mm]
Full Indirect
E R =R OUNDE D E ND C AP
Light Distribution
144" [3658mm]
Indirect - 100.0%
Direct - 0.0%
2-1/4"
[57mm]
*Dimens ions do not include end plates .
ORDERING INFORMATION
Sample Number: AI-WN-3T8-1C-UNV-AC48-T1-12-ET
Series
AI=Class A Indirect
Suspended
Optics Up
S=Specular
W=White
Optics Down
N=None
Number of Lamps
3=3 Lamps
Lamp Type
T8=T8 Normal Output
Number of Circuits
1=1 Circuit
1
Wiring 1
B=Battery Pack
Voltage 1
120=120V
C=Standard Circuit
D=Dimming
277=277V
347=347V
E=Emergency
T=Nightlight
UNV=Universal
(120V-277V)
Y=Daylight
2=2 Circuits
Suspension
A=Aircraft Cable
P=Rigid Pendant
Power Feed 1
C=Straight Cord
Notes: 1
2
Not all options available. Please consult your Cooper Lighting Representative for
availability.
Consult adder section of the price guide for additional standard lengths.
K=Curly Cord
P=Rigid Pendant
Suspension
Length
Fixed Cable
12", 15", 18", 21", 24",
or 27" (+/- 1/2"
adjustment)
Adjustable Cable
48", 120", 240", 300",
or 360" (infinite
adjustment along
entire length of cable)
Rigid Pendant
2
12", 15", 18", 21", 24",
or 27"
Ceiling Type
T1=1" T-Bar
Options
ER=Rounded End Cap
T9=9/16" T-Bar
TS=Slotted T-Bar
ET=Tapered End Cap
ST=Structure
JB=4" Octagonal
J-Box
Run Length
Individually Mounted
Luminaires may be 4', 8', or 12'
in length
Continuously Mounted
Standard row configurations over
12' consist of 8' and 12' sections
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADE032158
09/27/2012 6:36:16 PM
PHOTOMETRICS
Corelite
C o e f f i c i e n ts
o f U ti l i z a ti o n
C andela
E ffec tive floor c avity reflec tanc e
80%
70%
rc
rw
20%
50%
30%
10%
0%
A ngle
90
95
A long II
0
56
o
45
0
158
A c ros s I
0
157
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
0
83
83
83
83
71
71
71
71
49
49
49
28
28
28
09
09
09
00
105
115
283
589
746
1466
706
1474
1
2
3
4
76
69
63
57
72
63
55
49
69
58
49
42
66
54
45
38
65
59
53
49
62
54
47
42
59
50
43
37
57
47
39
33
42
37
33
29
41
35
30
26
40
33
27
23
24
21
19
17
24
20
17
15
23
19
16
14
08
07
06
05
08
07
06
05
07
06
05
04
00
00
00
00
125
135
145
155
886
1146
1370
1545
1832
1973
1982
1916
2106
2342
2336
2164
5
6
7
8
52
48
44
41
43
38
34
31
37
32
28
25
32
27
24
20
44
41
38
35
37
33
30
27
32
28
24
21
28
24
21
18
25
23
20
18
22
19
17
15
20
17
15
13
15
13
12
11
13
11
10
09
12
10
09
08
05
04
04
03
04
04
03
03
04
03
03
02
00
00
00
00
165
175
180
1659
1715
1704
1797
1711
1704
1925
1714
1704
9
10
38
28
22
18
32
24
19
16
17
13
11
10
08
07
03
03
02
00
35
25
20
16
30
22
17
14
15
12
10
09
07
06
03
02
02
00
RCR
A I-S N-3T 8
(3) F 32T 8/T L841
3000 Lumens
E fficiency 87.6%
T es t R eport
#IT L46591
Zonal L umen S ummary
Zone
0-90
90-120
L umens
0
2180
%L amp
0.0
24.2
%F ixture
0.0
27.7
90-130
90-150
90-180
3689
6341
7883
41.0
75.5
87.6
46.8
80.4
100.0
0-180
7883
87.6
100.0
COMMON CIRCUIT CONFIGURATIONS FOR TWO LAMP SUSPENDED FIXTURE
2C =T wo circuit luminaire
2E =T wo circuit luminaire with emergency circuit
2C
1B =S ingle circuit luminaire with battery pack
48"(1219mm)
=C ircuit 1
=C ircuit 2
=E mergency C ircuit
2E
=B attery C ircuit
96"(2438mm)
=P ower Mount
1B
=Non-P ower Mount
144"(3658mm)
STANDARD ROW CONFIGURATIONS
F IXT UR E
L E NG T H
4'
4'
1
8'
12'
8'
12' 16' 20' 24' 28' 32' 36' 40' 44' 48'
1
2
1
1
1
2
2
1
1
2
3
2
1
2
3
4
52' 56' 60' 64' 68'
2
1
3
4
5
2
1
4
5
72' 76' 80' 84' 88' 92' 96' 100' 104' 108'
6
2
1
5
6
7
Specifications and Dimensions subject to change without notice.
Corelite • 18001 E. Colfax Ave. • Aurora, CO 80011 • 303.393.1522 • FAX 303.393.1477
2
1
6
7
8
2
1
7
8
9
ADE032158
09/27/2012 6:36:16 PM
Download