Marquis LED Sign Light Sheet 1 of 2 INSTALLATION INSTRUCTIONS IMPORTANT: READ BEFORE REMOVING FIXTURE FROM CARTON. RETAIN FOR FUTURE REFERENCE. GENERAL: Upon receipt of fixture, thoroughly inspect for any freight damage, which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the housing to be sure the correct merchandise has been received. SAFETY: This fixture must be wired in accordance with the National Electrical Code, National Electrical Safety Code and applicable local codes and ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation section. This fixture is not suitable for Hazardous or Classified Locations. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and 10/11/10 IMI-742 hazards involved. Consult a qualified electrician to ensure correct branch circuit conductor. WARNING: Risk of Fire/Electric Shock. If not qualified, consult an electrician. WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing. WARNING: Risk of burn. Disconnect power and allow fixture to cool before servicing. WARNING: Risk of personal injury—Fixture may become damaged and/or unstable if not installed properly. Tighten all fixture components to their recommended torque values. WARNING: Fixture weight is 30 lbs. (14kgs), lift with care. WARNING: Make certain power is OFF before starting installation or attempting any maintenance. TOOLS REQUIRED: Wire cutters, flat head screwdriver, 9/16" socket, (7/16" socket, 3/4" socket for slipfitter mount option). FIG. 1 NOTE: Fixture is designed for horizontal mounting or with weep holes in the down position. FIG. 1 1. To access mounting clamps and wire terminal, open unit by releasing latches. FIG. 2 2. Mounting the fixture a. P ipe Mount Configuration (Internal Mast Arm)—Confirm the mounting clamps are loosely resting on the foam spacers. Slide fixture to pole stop. Level fixture using pole stop leveling steps and the internally mounted bulls eye level FIG. 3A. Once the fixture is level, tighten clamping bolts to the recommended torque of 100 in-lbs. b. Direct Mount Configuration—Position fixture as required and drill through mounting plate. Secure fixture with 3/8" diameter Class 5 or greater bolts (not provided). FIG. 3B NOTE: Pipe and Direct Mount—Attach user’s service leads to the three-position terminal block (3-wire service) connect the line lead (black) to #1 terminal and neutral lead to #3 terminal. Green ground wire to be connected to the center #2 terminal. FIG. 3A c. S lipfitter Mount Configuration—The slipfitter can be mounted on 2" or 2-1/2" pipe (2-3/8" to 2-7/8" O.D.). Set screws are provide to clamp it securely to the pipe. Install slipfitter to fixture bottom with provided 1/4-20 bolts. Torque to 70 in-lbs. Power supply leads and ground leads are provided to extend into the bottom half of the slipfitter. Remove the cover plate from the slipfitter and bring leads into compartment. Position fixture on mounting pole. Make power connections in slipfitter knuckle compartment. Securely tighten the pivot retainer bolt after aiming is accomplished. Bottom half of fitter is provided with support for wire coming up pole. FIG. 4 NOTE: Fixtures are wired for specified voltage (see caution label attached to the terminal block). 4. Close and latch door. 5. If the unit is supplied with a Photocell FIG. 5, then receptacle orientation will need to be position to the north direction. CAUTION: Receptacle has a built-in stop which permits 350° of rotation. Do not attempt to rotate beyond the stop. a. Loosen two flat head screws sufficiently to allow rotation of the receptacle. FIG. 5—Detail b. Insert screwdriver into center slot to rotate receptacle until arrow points north. c. Hold receptacle and tighten screws firmly. d. Insert photocell control and twist clockwise to a locked position. The photocell must contain a soft resilient gasket to assure a proper weather seal between photocell and receptacle. NOTE: This orientation procedure is only for photocells which specifically require that the cell be aimed north; otherwise the factory orientation will suffice. Local conditions such as photocell proximity to light-colored building surfaces, lighted flood lights, tree branches, etc., might affect the final required position of the photocell. Horizontal FIG. 2 Fixture must be mounted so weep holes drain water. Open unit by releasing latches #3 White #2 Green FIG. 3A #1 Black Bulls Eye Level Torque to100 in-lbs (8 ft-lbs) Pipe This surface to be level (horizontal) Slide fixture to pipe stop Different stop with different level adjustments These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative. NOTE: Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 P: 770.486.4800 F: 770.486.4801 www.cooperlighting.com ADH100845 Marquis LED Sign Light Sheet 2 of 2 INSTALLATION INSTRUCTIONS IMPORTANT: READ BEFORE REMOVING FIXTURE FROM CARTON. RETAIN FOR FUTURE REFERENCE. 10/11/10 IMI-742 WARNING: Make certain power is OFF before starting installation or attempting any maintenance. FIG. 3B FIG. 4 Drill through mounting plate (not shown). Secure fixture with 3/8" diameter bolts (not provided). Fitter to fixture mounting bolts (4) Torque to 70 in-lbs (6 ft-lbs) 3" [76mm] Wiring Compartment 13/16" [21mm] 5-3/16" [132mm] 3-3/8" [86mm] 1-3/4" [44mm] Fitter bolt (1) Torque to 480 in-lbs (40 ft-lbs) 7-1/2" [191mm] Fitter set screws (3) and jam nuts Torque to 120 in-lbs (10 ft-lbs) FIG. 5—Detail FIG. 5 Photocontrol Location Fixture facing up Photocontrol Location Fixture facing down 1. Pull out the photocell 2. Loosen the bolts Receptacle 3. Twist the receptacle until arrow points to the North These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative. NOTE: Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 P: 770.486.4800 F: 770.486.4801 www.cooperlighting.com ADH100845