GENERAL: Upon receipt of fixture, thoroughly inspect for any freight damage, which
should be brought to the attention of the delivery carrier. Compare the catalog
description listed on the packing slip with the fixture label on the housing to be sure
the correct merchandise has been received.
SAFETY: This fixture must be wired in accordance with the National Electrical Code,
National Electrical Safety Code and applicable local codes and ordinances. Proper
grounding is required to insure personal safety. Carefully observe grounding procedure
under installation section. This fixture is not suitable for Hazardous or Classified
Locations. This product must be installed in accordance with the applicable installation
code by a person familiar with the construction and operation of the product and
10/11/10
IMI-742
hazards involved. Consult a qualified electrician to ensure correct branch circuit
conductor.
WARNING: Risk of Fire/Electric Shock. If not qualified, consult an electrician.
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before
installing or servicing.
WARNING: Risk of burn. Disconnect power and allow fixture to cool before servicing.
WARNING: Risk of personal injury—Fixture may become damaged and/or unstable
if not installed properly. Tighten all fixture components to their recommended torque
values.
WARNING: Fixture weight is 30 lbs. (14kgs), lift with care.
WARNING: Make certain power is OFF before starting installation or attempting any maintenance.
TOOLS REQUIRED: Wire cutters, flat head screwdriver, 9/16" socket, (7/16" socket, 3/4" socket for
slipfitter mount option).
FIG. 1
NOTE: Fixture is designed for horizontal mounting or with weep holes in the down position. FIG. 1
1. To access mounting clamps and wire terminal, open unit by releasing latches. FIG. 2
2. Mounting the fixture
a. P
ipe Mount Configuration (Internal Mast Arm)—Confirm the mounting clamps are loosely
resting on the foam spacers. Slide fixture to pole stop. Level fixture using pole stop
leveling steps and the internally mounted bulls eye level FIG. 3A. Once the fixture is level,
tighten clamping bolts to the recommended torque of 100 in-lbs.
b. Direct Mount Configuration—Position fixture as required and drill through mounting plate.
Secure fixture with 3/8" diameter Class 5 or greater bolts (not provided). FIG. 3B
NOTE: Pipe and Direct Mount—Attach user’s service leads to the three-position terminal
block (3-wire service) connect the line lead (black) to #1 terminal and neutral lead to #3
terminal. Green ground wire to be connected to the center #2 terminal. FIG. 3A
c. S
lipfitter Mount Configuration—The slipfitter can be mounted on 2" or 2-1/2" pipe
(2-3/8" to 2-7/8" O.D.). Set screws are provide to clamp it securely to the pipe.
Install slipfitter to fixture bottom with provided 1/4-20 bolts. Torque to 70 in-lbs. Power supply
leads and ground leads are provided to extend into the bottom half of the slipfitter. Remove
the cover plate from the slipfitter and bring leads into compartment. Position fixture on
mounting pole. Make power connections in slipfitter knuckle compartment. Securely tighten
the pivot retainer bolt after aiming is accomplished. Bottom half of fitter is provided with
support for wire coming up pole. FIG. 4
NOTE: Fixtures are wired for specified voltage (see caution label attached to the terminal block).
4. Close and latch door.
5. If the unit is supplied with a Photocell FIG. 5, then receptacle orientation will need to be position to
the north direction. CAUTION: Receptacle has a built-in stop which permits 350° of rotation. Do not
attempt to rotate beyond the stop.
a. Loosen two flat head screws sufficiently to allow rotation of the receptacle. FIG. 5—Detail
b. Insert screwdriver into center slot to rotate receptacle until arrow points north.
c. Hold receptacle and tighten screws firmly.
d. Insert photocell control and twist clockwise to a locked position. The photocell must contain a
soft resilient gasket to assure a proper weather seal between photocell and receptacle.
NOTE: This orientation procedure is only for photocells which specifically require that the cell be
aimed north; otherwise the factory orientation will suffice. Local conditions such as photocell
proximity to light-colored building surfaces, lighted flood lights, tree branches, etc., might
affect the final required position of the photocell.
Horizontal
FIG. 2
Fixture must be mounted
so weep holes drain water.
Open unit by
releasing
latches
#3 White
#2 Green
FIG. 3A
#1 Black
Bulls Eye Level
Torque to100 in-lbs
(8 ft-lbs)
Pipe
This surface to be level (horizontal)
Slide fixture to pipe stop
Different stop with different level adjustments
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact
your nearest representative. NOTE: Specifications and dimensions subject to change without notice.
Customer First Center
1121 Highway 74 South
Peachtree City, GA 30269
P: 770.486.4800 F: 770.486.4801
www.cooperlighting.com
ADH100845
Marquis LED
Sign Light
Sheet 2 of 2
INSTALLATION INSTRUCTIONS
IMPORTANT: READ BEFORE REMOVING FIXTURE FROM CARTON.
RETAIN FOR FUTURE REFERENCE.
10/11/10
IMI-742
WARNING: Make certain power is OFF before starting installation or attempting any maintenance.
FIG. 3B
FIG. 4
Drill through mounting plate
(not shown). Secure fixture
with 3/8" diameter bolts
(not provided).
Fitter to fixture
mounting bolts (4)
Torque to 70 in-lbs (6 ft-lbs)
3"
[76mm]
Wiring
Compartment
13/16"
[21mm]
5-3/16"
[132mm]
3-3/8"
[86mm]
1-3/4"
[44mm]
Fitter bolt (1) Torque to
480 in-lbs (40 ft-lbs)
7-1/2"
[191mm]
Fitter set screws (3) and jam nuts
Torque to 120 in-lbs (10 ft-lbs)
FIG. 5—Detail
FIG. 5
Photocontrol Location
Fixture facing up
Photocontrol Location
Fixture facing down
1. Pull out the photocell
2. Loosen the bolts
Receptacle
3. Twist the receptacle until
arrow points to the North
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact
your nearest representative. NOTE: Specifications and dimensions subject to change without notice.
Customer First Center
1121 Highway 74 South
Peachtree City, GA 30269
P: 770.486.4800 F: 770.486.4801
www.cooperlighting.com
ADH100845
Download