Catalog # Type

advertisement
CORELITE
DESCRIPTION
Corelite's Stellar 9" 2T8 suspended direct-indirect fluorescent luminaire
produces energy efficient ambient illumination. The rugged painted
aluminum baffle assembly delivers high vertical footcandles ideal for stacks
and room perimeters. Stellar may be mounted individually or continuously
with 4', 8' and 12' modular sections. Luminaires align with T-Grid and
interface with all ceiling types. Stellar is best suited for high-ceiling open
offices, private offices, library stacks, conference rooms, corridors, schools,
labs and public spaces.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Construction
Die-formed all aluminum baffle
assembly mechanically (2" blade
spacing) attached to a corrosion
resistant formed steel ballast
channel. Perforated siderail
sections are 23% open with 0.0625"
stagger hole spacing. Standard
4'-0", 8-0", and 12'-0" fixture
lengths combine for continuous
rows.
B ... End Plates
Laser cut 14-gauge cold rolled
steel, mechanically attached
without exposed fasteners.
C ... Electrical
Fixtures are prewired with quick
wire connectors and use UL listed
Class P, 265ma T8 instant start
universal voltage electronic
ballasts. Power factor of 95% with
less than 10% THD. Fixtures and
electrical components certified to
UL and CUL standards.
D ... Finish
Fixture housings are standard
white using electrostatically
applied polyester powder coat
paint. Consult factory for custom
finishes.
Mounting
Standard aircraft cable mounts on
4'-0", 8'-0" and 12'-0" centers. Refer
to installation section for various
ceiling interface details and rigid
pendant mounting details.
Stellar
9"
S IDE V IE W
A
C
B
D
2T8
Suspended
2-7/8"
[74mm]
2-7/8"
[73mm]
Direct/Indirect
Light Distribution
Indirect - 54.0%
Direct - 46.0%
3/32" [2 mm]
9" [229mm]
MO DUL E S
AND
DIME NS IO NS *
48" [1219mm]
96" [2438mm]
144" [3658mm]
*Dimens ions do not include end plates .
ORDERING INFORMATION
Sample Number: S2-WB-2T8-1C-UNV-AC48-T1-12
Series
S2=Stellar 9"
Suspended
(2T8)
Optics Up
W=White
Optics Down
B=Baffle
Number of Lamps
2=2 Lamps
Lamp Type
T8=T8 Normal Output
Number of Circuits
1=1 Circuit
1
Wiring 1
B=Battery Pack
Voltage 1
120=120V
Suspension
A=Aircraft Cable
Suspension
Length
Ceiling Type
T1=1" T-Bar
C=Standard Circuit
D=Dimming
277=277V
347=347V
P=Rigid Pendant
Fixed Cable
T9=9/16" T-Bar
TS=Slotted T-Bar
E=Emergency
T=Nightlight
UNV=Universal
(120V277V)
Y=Daylight
2=2 Circuits
Power Feed 1
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
12", 15", 18", 21", 24",
or 27" (+/- 1/2"
adjustment)
Adjustable Cable
48", 120", 240", 300",
or 360" (infinite
adjustment along
entire length of cable)
Rigid Pendant
2
12", 15", 18", 21", 24",
or 27"
Notes: 1
2
Not all options available. Please consult your Cooper Lighting Representative
for availability.
ST=Structure
JB=4" Octagonal
J-Box
Run Length
Individually Mounted
Luminaires may be 4', 8', or 12' in
length
Continuously Mounted
Standard row configurations over
12' consist of 8' and 12' sections
Consult adder section of the price guide for additional standard lengths.
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADE032207
04/15/2009 2:06:01 PM
PHOTOMETRICS
Corelite
Coeffici e nts o f U tili zatio n
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30
rc
rw
S2-WB-2T8
(2) F32T8/TL835
3000 Lumens
Cand ela
20%
10
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
RCR
0
89
89
89
89
82
82
82
82
68
68
68
56
56
56
44
44
44
39
1
2
81
74
78
68
75
63
72
59
75
68
72
63
69
59
66
55
60
53
58
50
56
47
49
43
48
41
46
39
39
35
38
33
37
32
33
28
3
4
5
6
68
62
57
53
60
54
47
43
55
47
41
36
50
42
36
31
62
57
52
48
56
50
44
40
51
44
38
34
47
40
34
29
47
42
37
34
43
38
33
29
40
34
29
26
39
35
31
28
36
32
28
25
34
29
25
22
31
28
25
23
29
26
23
20
28
24
21
18
24
21
18
16
7
8
9
10
49
45
41
38
38
35
31
28
32
28
25
22
27
24
21
18
45
41
38
35
36
32
29
26
30
26
23
21
26
22
19
17
30
27
25
23
26
23
20
18
22
20
17
15
25
23
21
19
22
19
17
15
19
17
15
13
21
19
17
16
18
16
14
13
16
14
12
11
14
12
11
09
Along II
45
Across I
0
1004
1004
1004
5
15
980
860
990
898
998
948
25
35
697
515
770
638
893
836
45
55
65
75
327
212
134
69
501
364
222
121
767
608
383
215
85
90
95
105
17
5
42
165
72
65
127
285
130
107
162
311
115
125
135
145
298
426
525
592
452
548
607
640
480
620
656
664
155
165
175
180
639
661
665
662
656
663
663
662
663
656
658
662
Efficiency 83.9%
Test Report
#LSI13378
Zon al Lum en Summa r y
Lu mi nance D ata
Zone
0-30
Lumens
706
%Lamp
11.78
%Fixture
14.03
Angle
in Deg
0-Deg
cd/sm
45-Deg
cd/sm
90-Deg
cd/sm
0-40
0-60
0-90
1114
1853
2315
18.58
30.89
38.60
22.14
36.81
45.99
45
55
65
1664
1333
1136
2509
2234
1756
3811
3571
2746
40-90
60-90
90-180
0-180
1200
462
2719
5035
20.01
7.70
45.33
83.93
23.85
9.18
54.01
100.00
75
85
957
690
1312
1174
1984
1588
o
Angle
COMMON CIRCUIT CONFIGURATIONS FOR TWO LAMP SUSPENDED FIXTURE
2C =T wo circuit luminaire
2E =T wo circuit luminaire with emergency circuit
2C
1B =S ingle circuit luminaire with battery pack
48"(1219mm)
=C ircuit 1
2E
=E mergency C ircuit
=B attery C ircuit
96"(2438mm)
=P ower Mount
1B
=Non-P ower Mount
144"(3658mm)
STANDARD ROW CONFIGURATIONS
F IXT UR E
L E NG T H
4'
4'
1
8'
12'
8'
12' 16' 20' 24' 28' 32' 36' 40' 44' 48'
1
2
1
1
1
2
2
1
1
2
3
2
1
2
3
4
52' 56' 60' 64' 68'
2
1
3
4
5
2
1
4
5
72' 76' 80' 84' 88' 92' 96' 100' 104' 108'
6
2
1
5
6
7
Specifications and Dimensions subject to change without notice.
Corelite • 18001 E. Colfax Ave. • Aurora, CO 80011 • 303.393.1522 • FAX 303.393.1477
2
1
6
7
8
2
1
7
8
9
ADE032207
04/15/2009 2:06:01 PM
PHOTOMETRICS
C o e f f i c i e n ts
rc
rw
RCR
S B -WB -2T 8
DL 100
100% Downlight K it
(2) F 32T 8/T L835
3000 Lumens
E fficiency 64.5%
T es t R eport
#LS I14066
o f U ti l i z a ti o n
C andela
E ffec tive floor c avity reflec tanc e
80%
70%
20%
50%
30%
10%
0%
A ngle
0
A long II
1549
45 o
1549
A c ros s I
1549
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
5
15
1526
1392
1535
1434
1542
1489
0
1
76
70
76
67
76
65
76
62
74
68
74
66
74
63
74
61
71
63
71
61
71
59
67
60
67
58
67
67
64
57
64
56
64
55
63
53
25
35
1194
958
1275
1087
1403
1279
2
3
4
5
64
59
55
50
60
53
48
42
56
48
42
37
52
44
38
33
63
58
53
49
58
52
47
42
55
48
42
36
51
44
38
33
56
50
45
40
53
46
41
35
50
43
37
32
53
48
43
38
41
45
39
35
49
42
37
32
51
46
41
37
49
43
38
34
47
41
36
31
46
40
34
30
45
55
65
75
701
433
238
118
868
614
375
210
1081
818
518
259
6
7
8
9
46
43
39
36
38
34
31
28
33
29
26
23
29
25
22
19
45
42
38
35
37
34
30
27
32
29
25
22
28
25
22
19
36
33
29
27
32
28
25
22
28
25
22
19
35
31
28
26
31
27
24
22
28
24
21
19
34
31
28
25
30
27
24
21
27
24
21
18
26
23
20
17
85
90
95
105
23
0
0
0
121
89
70
33
146
102
85
40
10
34
25
20
17
33
25
20
17
24
20
17
23
19
16
23
19
16
15
115
0
16
15
125
135
0
0
10
5
11
11
145
155
165
175
180
0
0
0
0
0
2
0
0
0
0
7
0
0
0
0
A ngle
0
5
15
A long II
1262
1248
1144
45 o
1262
1252
1175
A c ros s I
1262
1252
1209
Zonal L umen S ummary
L u m i n a n c e D a ta
Zone
0-30
0-40
0-60
L umens
1142
1828
3054
%L amp
19.04
30.48
50.90
%F ixture
29.52
47.26
78.94
A ngle
0-Deg
in Deg
45
55
c d/s m
4267
3251
45-Deg
c d/s m
5194
4512
90-Deg
c d/s m
6443
5762
0-90
40-90
60-90
3754
1925
700
62.57
32.10
11.67
97.04
49.78
18.10
65
75
85
2423
1957
1148
3541
2736
2357
4459
2871
2137
90-180
0-180
114
3868
1.91
64.48
2.96
100.00
PHOTOMETRICS
C o e f f i c i e n ts
rc
rw
o f U ti l i z a ti o n
C andela
E ffec tive floor c avity reflec tanc e
80%
70%
20%
50%
30%
10%
0%
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
0
1
2
3
4
5
82
75
69
63
58
53
82
72
63
56
50
44
82
69
59
51
44
39
82
67
55
47
40
34
78
71
65
60
55
50
78
68
60
54
48
43
78
66
56
49
43
37
78
63
53
45
39
33
69
61
54
49
43
39
69
59
51
45
39
34
69
58
49
42
36
31
62
55
49
44
39
35
62
54
47
41
36
31
62
52
44
38
33
29
55
49
44
39
35
32
55
48
42
37
33
29
55
47
40
35
31
26
52
44
38
33
28
24
25
35
45
55
65
75
968
776
567
348
191
95
1041
883
719
527
320
178
1139
1048
913
691
435
216
6
7
49
45
40
36
34
30
30
26
46
43
38
34
33
29
29
25
35
31
30
27
27
24
32
29
28
25
25
22
29
26
26
23
23
20
21
19
85
90
20
0
98
77
120
94
8
9
42
39
32
29
27
23
23
20
39
36
31
28
26
23
22
19
28
26
24
21
20
18
26
23
22
19
19
17
23
21
20
18
18
15
16
14
95
105
11
69
79
137
101
155
10
36
27
21
17
34
25
20
17
23
19
16
21
17
15
19
16
14
12
115
125
135
191
205
253
221
284
135
145
155
165
175
180
239
270
291
308
299
295
282
298
310
308
296
295
305
308
307
299
293
295
RCR
S B -WB -2T 8
DL 70
70% Downlight K it
(2) F 32T 8/T L835
3000 Lumens
E fficiency 73.1%
T es t R eport
#LS I14067
Zonal L umen S ummary
L u m i n a n c e D a ta
Zone
0-30
L umens
931
%L amp
15.53
%F ixture
21.23
A ngle
in Deg
0-Deg
c d/s m
45-Deg
c d/s m
90-Deg
c d/s m
0-40
0-60
0-90
40-90
60-90
90-180
0-180
1493
2518
3109
1616
591
1279
4388
24.88
41.97
51.82
26.94
9.86
21.32
73.15
34.02
57.38
70.85
36.83
13.48
29.15
100.00
45
55
65
75
85
2874
2179
1624
1320
813
3586
3225
2520
1927
1593
4534
4054
3117
1991
1465
Specifications and Dimensions subject to change without notice.
Corelite • 18001 E. Colfax Ave. • Aurora, CO 80011 • 303.393.1522 • FAX 303.393.1477
ADE032207
04/15/2009 2:06:01 PM
Download