100-Watt Driver POWER SUPPLY 100ND-12X6X4 Key Features UL Class 2 Ultra small, compact size Tightly regulated output: 1% line, 5% load Power factor: 90% min Total harmonic distortion: 20% max Current crest factor: 1.5 max Specifications Location: Damp IP66 Output Voltage: 24v DC Output Power: 100w Input Voltage: 120 to 277 VAC Ambient Temp: -40˚C to +50˚C Weight: 1.41 lbs Dimming: Requires io provided Dimming Module Note: 11” (L) x 4” (W) x 4” (H) enclosure is requied by UL. Remote Distance 7'-0"(2.1m) 18'-0" (5.5m) 46'-0" (14.0m) 71'-0" (21.6m) 100W Diameter w/22 AWG w/18 AWG w/14 AWG w/12 AWG Max Run Length in Series (.644mm) (1.02mm) (1.63mm) (2.05 mm) Max Run Lengths in Parallel line .75 - SO / ledge / luxrail47’ (14.33m)87’ (26.52m) line .75 - MO / ledge / luxrail19’ (5.79m) 35’ (10.67m) line .75 - HO / ledge / luxrail12’ (3.66m)23’ (7.018m) line .75 - VHO (and color) / ledge9’ (2.74m)17’ (5.18m) line 1.5 - SO 30’ (3.66m)60’(18.23m) line 1.5 - MO 12’ (2.29m)24’ (7.32m) line 1.5 - HO 8’ (2.44m)16’ (4.88m) line 1.5 - VHO (and color) 6’ (1.82m)12’(3.66m) line 2.0 - SO 26’ (7.92m)26’ (7.92m) line 2.0 - HO 17’ (5.18m)17’ (5.18m) line 2.0 - VHO 12’ (3.66m)12’ (3.66m) line 2.0 - V2HO / B / G / A8’ (2.44m)8’ (2.44m) lineBusch 2.0 Pkwy - ioR6’ (1.82m)6’ (1.82m) Buffalo Grove, 1100 Busch IL 60089 Pkwy Buffalo Grove, IL 60089 io Lighting 1100 Lighting T 847.777.3900 F 847.777.3901 T 847.777.3900 E info@iolighting.com F 847.777.3901 W iolighting.com E info@iolighting.com W iolighting.com 04_16_14 io Lighting 1100 Busch Pkwy io Lighting Buffalo Grove, 1100 Busch IL 60089 Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 T 847.777.3900 E info@iolighting.com F 847.777.3901 W iolighting.com E info@iolighting.com W iolighting.com 12x6x4 Enclosure POWER SUPPLY 100ND-12X6X4 Enclosure Construction Enclosure and cover are fabricated from code 16 gauge steel. Enclosure body has mounting holes on the back and are available with or without knock outs on the sides, top and bottom ends. Cover is secured to the body with plated hex head combo screws, and has keyhole slots for easy removal without removing screws. Enclosure Industry Standards UL 50 Listed, Type 1 CSA C22.2 No. 40 certified, Type 1 Conforms to NEMA standard for Type 1 IEC 60529, IP30 *One driver enclosure can hold one 20W or 100W driver and one dimming module. Left End With Cover Front View Without Cover knockout area (see table for pattern, see detail for size) 4’’ 12’’ A-1.00 (25) .25 (6) mounting hole (4PL) Conduit Sizes 1.62’’ (41) 1.87’’ (47) 1.87’’ (47) 6’’ 1.62’’ (41) Note: Dimensions are in inches. Millimeters are for reference only. Data subject to change withoutW iolighting.com notice. Buffalo Grove, 1100 Busch IL 60089 Pkwy Buffalo Grove, IL 60089 io Lighting 1100 Busch Pkwy io Lighting T 847.777.3900 F 847.777.3901 T 847.777.3900 E info@iolighting.com F 847.777.3901 E info@iolighting.com W iolighting.com D ¾-1 E ½-¾ F 1-1¼ G ½-¾ H ¾-1 04_16_14 io Lighting 1100 Busch Pkwy io Lighting Buffalo Grove, 1100 Busch IL 60089 Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 T 847.777.3900 E info@iolighting.com F 847.777.3901 W iolighting.com E info@iolighting.com W iolighting.com