GHG43 Series 4C Control Stations

advertisement
4C GHG43 Series
Control Stations
Nonmetallic or 316L Stainless
Steel Corrosion Resistant
UL/cUL listed
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zones 1 and 2,
(A) Ex de IIB + H2 T6
Cl. II, Div. 1, Groups E, F, G (cUL)
PTB ATEX CERTIFIED 3117
Ex de IIC, T6,
Zones 1 and 2
Ex de IIC,T6 Zones 21 and 22
IP 66, NEMA 4X
4C
Applications:
Control stations are used as a remote
means of:
• Motor control
• Visual indication of equipment
performance
• On-off control of circuits
• Circuit selection
Common applications include:
• Areas which are hazardous due to the
presence of flammable vapors, gases or
highly combustible dusts
• For installation at petroleum refineries,
chemical and petrochemical plants and
other process industry facilities where
similar hazards exist
Features:
GHG43 Nonmetallic Control Stations
• NEMA 4X, IP66 enclosure with formedin-place gasket
• Available with all operators: indicator
lights, potentiometers, control switches,
pushbuttons, terminal blocks and meters
• Base-mounted contact blocks
• Easy change-out components snap in
place on DIN rail
• Enclosure meets UL 94-VO. Also
available in anti-static Ex e materials
• Inserts for mounting DIN rails
• Available with a maximum of 2 entries top and bottom for conduit fittings or
cable glands
• Suitable for universal mounting plates on
pipes, conduit, wall or channels
• Mounting dimensions data molded on
back
• Captive, corrosion-resistant cover
screws
• Built-in mounting slots for wall
installation
• Available in 316L stainless steel
GHG43 Stainless Steel Control Stations
Certifications and
Compliances:
•
•
•
•
•
•
•
•
UL/cUL Listed
Class I, Div. 2, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G (cUL)
Class I, Zones 1 and 2, Ex de IIB + H2, T6
AEx de IIB + H2, T6
Type 3, 4, 4X; IP66
CENELEC-PTB 00 ATEX 3117
Ex de IIC, T6, Zones 1 and 2, IP66
Options:
Description
Eaton's Crouse-Hinds GHG43
Series control stations are now
available with 316L stainless steel
enclosures, making them ideal for
corrosive and adverse locations especially offshore platform
applications
556
www.crouse-hinds.com
Suffix
S860
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
GHG43 Series Control Stations
How to build a GHG43 Series Catalog Number‡
4C
Nonmetallic or 316L Stainless
Steel Corrosion Resistant
GHG43 2 - Size 2 Enclosure
Codes see page 559
4C
Pushbutton DRT
Codes see page 559
Double
Pushbutton
Mounting Area*
GHG43 4 - Size 4 Enclosure
Codes see page 559
Key Operated
Pushbutton
Codes see page 560
Mushroom-Head
Pushbutton
Codes see page 560
Mounting Area*
Signal Lamp
‡For a GHG43 control station with 316L stainless steel enclosure, add suffix "S860" to end of catalog number.
*Unoccupied spaces must be filled in with KLM for correct positioning of devices.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
557
4C
GHG43 Series Control Stations
How to build a GHG43 Series Catalog Number‡
Nonmetallic or 316L Stainless
Steel Corrosion Resistant
Cable Entries
NPT
Metric
No entries
No entries
2 x 1/2" Myers Hub,
STGK1 Zinc Gland
plate
2 x M25 Plastic
Cable gland M25
Blanking plug
4C
Codes see page 561
Potentiometer
Two entries
Codes see page 562
Requires 2 spaces
2 x 3/4" Myers Hub,
2 x M20
STGK2 Zinc Gland
Threaded entries
plate
Gland plate
(Stainless Steel
Control Stations only)
Measuring Instrument
One entry
2 x 1/2" Myers Hub,
SSTGK1 Stainless
steel
Gland plate
Codes see pages 563–564
2 x 3/4" Myers Hub,
1 x M32 Plastic
SSTGK2 Stainless
Cable gland
steel
Gland plate
(Stainless Steel
Control Stations only)
Switch
Codes see pages 563–564
Requires 2 spaces
Control Switch Ex 23 10A
Code see page 561
1 x 3/4" Myers Hub,
STGK2, Zone 1
Gland plate
1 x M25
Threaded Entry,
Blanking plug and
Gland plate
1 x 1/2" Myers Hub,
STGK1, Zone 1
Gland plate
2 x M25
Threaded Entry,
1 blanking plug and
Gland plate
1 x 1/2" Myers Hub,
1 x M20
SSTGK1 Stainless st. Threaded entry
Gland plate
Blanking plug and
Gland plate
Terminals and cover
blanking plug
1 x 3/4" Myers Hub,
1 x 3/ 4"
SSTGK2 Stainless st. Myers Hub
Gland plate
SSTGK2 stainless
steel,
Gland plate
‡For a GHG43 control station with 316L stainless steel enclosure, add suffix "S860" to end of catalog number.
*Unoccupied spaces must be filled in with KLM for correct positioning of devices.
558
www.crouse-hinds.com
2 x M25
Threaded entries
Gland plate
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
GHG43 Series Control Stations
4C
Pushbuttons Technical Data
Nonmetallic or 316L Stainless
Steel Corrosion Resistant
Pushbuttons:
• Used for logic controls in hazardous
areas
• Single or double units
• Used with all operators
• Base mounting
Pushbutton
Ex de IIC T6
PTB No. Ex-87.B.1007U
PTB, UL, cUL
Up to 400V
NEC/CEC 10A IEC 16 A
2 x 2.5mm2 / 14AWG
>105 Operations
Type of Protection
Certificate of Conformity
Approvals
Rated Voltage
Rated Current
Terminal Wiring
Mechanical and Electrical Life
See page 564 for explanation of contact symbols.
Pushbutton DRT
D
R
Code
T
O
A
B
C
D
4C
Contact System
Code B
13
14
Inscription
ALL *
0 I
II Stop
Code C
01
02 03 04 06
Lockout see page 565
Code D (leave blank if no lockout required)
15
Start
Special-Text On Order †
07
99
Double Pushbutton DDTO
D
D
Code
T
O
A
B
C
D
E
Contact System
Code B
43
Inscription
Code C, D Left/Right
44
ALL *
0
01
02 03 04 06
I
II
45
Stop
Start
Special-Text on Order †
07
99
Lockout see page 565
Code E (leave blank if no lockout required)
Key-Operated Pushbutton SLT
S
Code
L
T
O
A
B
C
Contact System
Code B
23
Pushbutton
Key
Not Depressed
Lockable
Key Removable
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Yes
Yes
Yes
Lockable
Key Removable
Yes
No
No
No
Yes
Yes
Yes
Yes
Auto
Yes
Yes
Yes
1
2
3
4
5
6
Depressed
Code C
24
25
* 01 - Includes the following discs - Start, stop, I, O, and red, green, yellow, white and black blank discs.
† For Marking Guide for Pushbuttons see page 565.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
559
4C
GHG43 Series Control Stations
Pushbuttons and Signal Lamps
Technical Data
Nonmetallic or 316L Stainless Steel
Corrosion Resistant
Mushroom-Head Pushbutton SGT
S
G
Code
T
A
B
C
D
E
F
4C
Contact System
Code B
53
54
55
Color of Pushbutton
Code C
Red
1
Yellow
2
Black Actuator
3
Function
Code D
Spring Return
1
Maintained
2
Key Release
3
Inscription
Code E
Stop
06
Start
07
Emergency Stop
11
Lockout
see page 565
Code F (leave blank if no lockout required)
Signal Lamp
tø6TFEGPSQPTJUJWFGFFECBDLJOEJDBUJPO
tø)JHIJOUFOTJUZXJUITQFDJBMSFGMFDUPSBOE
optical lens
tø"DDPNPEBUFTNPTUJOQVUWPMUBHFT
tø#BTFNPVOUJOH
Lamp
Ex de IIC T6
PTB No. Ex-88.B.2106U
PTB, UL, cUL
>100,000 Hours (11.5 Years)
Up to 240VAC, 50 / 60 Hz
Up to 110VDC
Max. 15 mA
<1.2W
2 x 2.5mm2 / 14AWG
Red, Green, Yellow, Clear & Blue
Type of Protection
Certificate of Conformity
Approvals
Lamp Life
Rated Voltages
Rated Current
Power Consumption
Terminal Wiring
Colors
Signal Lamp SIL
Code
S
I
L
A
Colored
Lens Cover White
Code B
1
Voltage
Code C
www.crouse-hinds.com
US: 1-866-764-5454
B
Yellow
2
C
Red
3
20-250VAC/DC
01
CAN: 1-800-265-0502
Copyright© 2016 Eaton
1 pkg
white,
yellow,
red, green
4
Green
5
10-33VAC/DC
31
Blue
6
GHG43 Series Control Stations
4C
Terminal Blocks and Potentiometers
Technical Data
Nonmetallic or 316L Stainless Steel
Corrosion Resistant
Terminal Blocks
• Terminal block for easy field connections
• Base mounting
Terminal Blocks
Ex e II
PTB No. Ex-88.B.3112U
Up to 400V
23A
4mm2 / 12AWG
Type of Protection
Certificate of Conformity
Rated Voltages
Rated Current
Conductor Size
Terminals and Cover Plugs
KLM
K
Code
L
M
A
6 Terminals 2 x 4 mm2
Undrilled Cover (No Terminals)
61
00
Potentiometers
4C
Code B
B
Potentiometers
• Used to adjust resistance to vary motor
speed or light levels
• Scale 0 to 100%
• Base mounting
Type of Protection
Certificate of Conformity
Approvals
Rated Voltages
Power Consumption
Resistance
Angle of Rotation
Scale
Connection Terminals
Ex de IIC T6
PTB No. Ex-87.B.1007U
PTB, UL, cUL
>250V
1.0W
100–10,000W
270°
0–100%
2 x 2.5mm2 / 14AWG
Potentiometer POT
P
Code
O
A
T
B
Power Consumption
1W
Resistance W
Code B
1,000
4
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
2,200
7
4,700
5
10,000
6
Copyright© 2013 Eaton’s Crouse-Hinds Business
561
GHG43 Series Control Stations
4C
Ammeters
Technical Data
Nonmetallic or 316L Stainless Steel
Corrosion Resistant
Ammeters
• Used to measure motor current draw for
efficiencies and maintenance
• Slide in scales to accommodate any
amperage range
• Red indicator for quick visual indication
to compare set points and actual values
4C
Ammeters
Type of Protection
Certificate of Conformity
Ex e II T6
PTB No. Ex-87.B.2016U
Approvals
PTB, UL, cUL
Movement
Moving iron (core)
Accuracy
2.5% of range (class 2.5)
Measuring Range
0-16A direct, C.T. n/1 A
Operating Position
Vertical
Scale
Interchangeable for C.T. n/1 A
Zero Adjustment
At instrument
Terminal Wiring
2 x 2.5 mm2 / 14 AWG
Rated Current Marking
Red indicator
Ammeter Measuring
Instrument AM 72*
M
7
Code
2
A
B
C
Movement
Direct
n/1 A
0 - 2 mA
Code B
1
2
3
Movements 0-20 mA and 4-20 mA are only available with 0 - 100 / 120% scale
Direct Measurement
Code C
Scale
Interchangeable Scale for C.T. n/1A
Code C
Scale
Code C
02
03
04
05
07
02
03
04
05
06
08
0
0
0
0
0
-1/1.5A
- 2.5/3.75A
-5/7.5A
- 10/15A
- 16/24A
0
0
0
0
0
0
-1/1.5A
- 2.5/3.75A
-5/7.5A
- 10/15A
-15/22.5A
- 20/30A
09
10
11
12
13
14
15
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
6
Scale
Code C
Scale
0
0
0
0
0
0
0
16
17
18
19
20
21
22
0
0
0
0
0
0
0
- 30/45A
- 40/60A
- 50/75A
- 60/90A
-75/112.5A
- 100/150A
- 150/225A
* Requires 2 spaces.
562
4-20 mA
Copyright© 2013 Eaton’s Crouse-Hinds Business
-
200/300A
250/375A
300/450A
400/600A
500/750A
600/900A
100/150A
GHG43 Series Control Stations
4C
Rotary Switches
Technical Data
Nonmetallic or 316L Stainless Steel
Corrosion Resistant
Rotary Control Switches
• Used for selectable operations (i.e.
Hand–Off–Auto)
• 2 independent contacts
• Available in any contact configuration
• Spring return or maintained position
• Available with lockout positions
Type of Protection
Certificate of Conformity
Approvals
Rated Votage
Rated Current
Terminal Wiring
Mechanical Life
Electrical Life
Switching Capacity
Ex 23
Ex de IIC T6
Ex.87.B.1007U
PTB, UL, cUL
400 V
NEC 10 A
IEC 16 A
2 x 2.5mm2 / 14 AWG
>105 Operations
>105 Operations
AC II: 20V/6A
400V/4A
DC II: 24V/6A
60V/0.8A
110V/.5A
220V/.2A
Ex de IIC T6
PTB no. Ex-88.B.1047U
PTB, UL, cUL
Up to 500 V
NEC 10 A
IEC 16 A
2 x 2.5mm2 / 14 AWG
>105 Operations
>105 Operations
AC I: 500G/10A
AC II: 230V/6A
500V/6A
DC II: 24V/6A
48V/4A
60V/0.8A
110V/0.5A
220V/0.4A
4C
SCT
Rotary Control Switch SCT
S
C
Code
T
A
B
C
D
Switch Mechanism
Code B
Code C
01
03
04
06
29
Same as SCT above except up to 4
independent contacts
Inscription
0
STOP
HAND
REMOTE
OFF
I
START
AUTO
LOCAL
ON
Code C
Inscription
07
13
14
15
99
I
LOCAL
STOP
HAND
Special – text
0
II
REMOTE
AUTO
0
START
0
AUTO
to be given on order
Contact
System
Code D
1
2
3
4
5
6
Rotary Control Switch Ex 23*
E
Code
x
2
3
A
Code B
01
03
04
06
07
13
14
23
24
27
29
32
99
B
C
D
E
Inscription
0
I
STOP
START
HAND
AUTO
remote
local
I
0
LOCAL
REMOTE
STOP
0
OFF
0
HAND
OFF
START
STOP
OFF
ON
ON
OFF
Special – text to be given on order
AUTO
START
ON
AUTO
* Requires 2 spaces in cover.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
563
4C
GHG43 Series Control Stations
Rotary Switches
Technical Data
Nonmetallic or 316L Stainless Steel
Corrosion Resistant
Type
Code C
00
2 Position
09
3 Position
01
2 Position
10
3 Position
02
2 Position
12
3 Position
03
Single Pole
Changeover
13
2 Position
05
HOA
14
2 Position
07
3 Position Single
Level
15
3 Position Double
Pole Changeover
4C
Code C
Contact System
Contact System
Type
Switched Mechanism
Code D
Padlocking Facility
Code E
Contact Configurations
Normally Closed
Normally Open
Normally Closed Extended Over
2 Positions
Normally Open Early Make/Late
Break
Change-Over Break Before Make
Change-Over Make Before Break
Example of Switch Type 10
This example is the switch type 10 Stop-Run-Stop. The switch has 3
positions – the normal position is center and can be switched left or
right. An arrow (→←) indicates spring return. (See codes for switch
mechanism). Contacts 1–2 only close in the Stop position. Contacts 3–
4 close only in the Start position. Contacts 5–6 are normally closed
and remain closed when switched to the Start position and open when
switched to the Stop position.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2014 Eaton’s Crouse-Hinds Business
GHG43 Series Control Stations
Lockouts for Pushbuttons
and Marking Guide for Pushbuttons
4C
Nonmetallic or 316L Stainless Steel
Corrosion Resistant
Lockouts for DRTO Pushbuttons
X
Code D
Shroud Cover For
Pushbutton
Y-Lockout with bolt and chain
Z
Code D
Padlocking Fire Alarm
Cover For Pushbutton
Lockouts for DDTO Double Pushbuttons
Z
Code E
Padlocking Cover For
Double Pushbutton
With Hole
4C
X
Code ED
Padlocking Cover For
Double Pushbutton
Without Hole
Lockouts for SGT Mushroom-Head Pushbuttons
X
Code F
Padlocking Cover For
Emergency Stop Pushbutton
Z
Code F
Padlocking Cover For
Emergency Stop Pushbutton
With Bolt & Chain
Not permitted in IEC hazardous
locations.
Marking Guide For Pushbuttons
Special Text
Marking Required
Acknowledge
Alarm
Automatic
Close
Down
Standard Abbreviation
AK
AM
AU
CL
DN
Actual Marking on Disc
ACK
ALARM
AUTO
CLOSE
DOWN
Fast
Forward
Hand
High
In
Jog
FS
FW
HN
HI
IN
JG
FAST
FWD
HAND
HIGH
IN
JOG
Local
Lower
Maintain
Manual
Normal
Off
LC
LO
MT
MN
NR
OF
LOCAL
LOWER
MAINT
MANUAL
NORMAL
OFF
On
Open
Out
Raise
Remote
Reset
ON
OP
OT
RA
RM
RS
ON
OPEN
OUT
RAISE
REMOTE
RESET
Reverse
Run
Slow
Test
Trip
Up
RV
RN
SL
TT
TP
UP
REV
RUN
SLOW
TEST
TRIP
UP
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
565
4C
GHG43 Series Control Stations
Dimensions
Nonmetallic or 316L Stainless Steel
Corrosion Resistant
4C
GHG43 Nonmetallic Control Stations
End View of Back Box
GHG43 Size 4 Nonmetallic
GHG43 Size 2 Nonmetallic
GHG43 Stainless Steel Control Stations
Box Type
Dimension (inches)
A
B
C
D
E
F
G
H
J
K
L
M
1 Operator Control Station
4.72
4.72
4.96
4.96
3.60
3.94
3.94
3.15
2.76
0.79
2.36
2.36
2 Operator Control Station
6.69
4.72
6.93
4.96
3.60
5.90
3.94
5.12
2.76
0.79
4.33
2.36
3 Operator Control Station
8.66
4.72
8.90
4.96
3.60
7.87
3.94
7.09
2.76
0.79
6.30
2.36
4 Operator Control Station
10.63
4.72
10.87
4.96
3.60
9.84
3.94
9.06
2.76
0.79
8.27
2.36
566
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
Download