Catalog# Description RB200*† RB2001*†

advertisement
Catalog#Description
RB200*†
Indoor Use, 6x 20A Duplex Straight Blade, 1x 30A Locking
RB2001*†
Indoor Use, 7x 20A Duplex Straight Blade
RB201*†
Indoor Use, 6x 20A Single Straight Blade, 1x 30A Locking
RB202*†
Indoor Use, 6x 20A Locking, 1x 30A Locking
RB203*†
Indoor Use, 3x 20A Single Straight Blade, 3x 20A Locking, 1x 30A Locking
RB300*†
Outdoor Use, 6x 20A Duplex Straight Blade, 1x 30A Locking
RB3001*†
Outdoor Use, 7x 20A Duplex Straight Blade
RB301*†
Outdoor Use, 6x 20A Single Straight Blade, 1x 30A Locking
RB302*†
Outdoor Use, 6x 20A Locking, 1x 30A Locking
RB3021*†
Outdoor Use, 7x 20A Locking
RB303*†
Outdoor Use, 3x 20A Single Straight Blade, 3x 20A Locking, 1x 30A Locking
3
3
3
2
3
COOPER Wiring Devices
20 A
OFF
OFF
20 A
OFF
OFF
4
20 A
OFF
1.
2.
3.
4.
3
20 A
1
COOPER Wiring Devices
OFF
COOPER Wiring Devices
COOPER Wiring Devices
20 A
COOPER Wiring Devices
OFF
COOPER Wiring Devices
20 A
COOPER Wiring Devices
OFF
20 A
COOPER Wiring Devices
20 A
*(M) Manual reset GFCIs; (A) Automatic reset GFCIs
**Other configurations may be available upon request
† Ground Fault Protection options available upon request for 30A and 50A outputs
3
125/250V AC 50A Locking Inlet “CS” with flip-up cover on rainproof models.
125/250V 50A Locking Receptacle “CS”, not circuit breaker or GFCI protected.
Class “A” 20A GFCIs.
Circuit breakers.
Cooper Wiring Devices • 203 Cooper Circle, Peachtree City, GA 30269 • 866-853-4293 • www.cooperwiringdevices.com
WARNING
To reduce the risk of electrical shock, ground this unit at the supply source and use only in the upright position.
Test each GFCI module and/or GFCI breaker before use.
APPLICABLE TO AUTOMATIC RESET GFCI Models ONLY
This unit contains Ground Fault Circuit Interrupters that automatically reset upon power up or restoration of power.
DO NOT USE THIS UNIT when automatic power up would create an unsafe condition.
Use only units with manual resetting Ground Fault Circuit Interrupters when such conditions exist.
Caution!
• To reduce the risk of electrical shock, ground this unit at the supply source and use only in the upright position.
Ground fault protection will not guard against shock hazard resulting from:
• Physical contact with both circuit conductors.
• Any defect in the wiring of the electric supply to this unit.
• The Manual Resetting GFCIs (M) require resetting after a power interruption and at power up . The Automatic Resetting GFCIs (A) do not need to be reset after a power interruption. When power is restored, tools and equipment may restart. • The power indicator lamp in the GFCI may fail from age or damage.
Do not assume that the power is OFF if the power indicator light is not lit.
MODELS
• The 30 AMP and 50 AMP receptacles are not GFCI protected.
SPECIFICATION
RB200* RB2001 RB201 RB202 RB3021*RB203*
20A Ground fault module test instructions (automatic models):
Test each GFCI before each use.
RB300*RB3001RB301 RB302 RB303*
1. Apply power to RhinoBox™. Each GFCI power indicator light should turn ON.
50A, 125/250VAC, 60 Hz
2. Press test button. Each GFCI power indicator light should turn OFF.
Input
3-Pole,4-Wire Grounding -
Yes (1) Yes (1) Yes (1) Yes (1) Yes (1) Yes (1)
3. Press reset button again for use.
CS
style
Inlet
(male)
20A Ground fault module test instructions (manual models):
50A, 125/250VAC, 60 Hz
Test each GFCI before each use.
3-Pole, 4-Wire Grounding, -
Yes (1) Yes (1) Yes (1) Yes (1) Yes (1) Yes (1)
1. Apply power to RhinoBox. Press reset button on each GFCI. Each GFCI power
CS6369, CS6364
indicator light should turn ON.
CS style Outlet (female)
2. Press test button. Each GFCI power indicator light should turn OFF.
Single Locking
X
3. Press reset button again for use.
30A, 250VAC, NEMA L6-30R** Y Yes (1)
No Yes (1) Yes (1) No
Yes (1)
G
30A and/or 50A Ground Fault Breaker Protection test instructions for models with
CS6365, CS6375, CS6376
OutputReceptacle
-30GF, -50GF, and/or -30/50GF option:
L6-30R
Single Locking
W
Test each GFCI before each use.
20A, 125VAC,
No
No
No Yes (6) Yes (7) Yes (3)
1. Apply power to RhinoBox. Move the handle of each Ground Fault Breaker from
G
the OFF position to the ON position.
NEMA L5-20R
L5-20R
2. Press each test button. Each GFCI breaker will trip.
Single Straight Blade
G
3. Turn the breakers back to the ON position by moving the switch handles.
20A, 125VACW
No
No Yes (6) No
No
Yes (3)
DO NOT USE IF ABOVE TEST FAILS
NEMA 5-20R
Duplex Straight Blade
Operating Instructions:
5-20R
G
• Make sure no equipment is plugged into the RhinoBox Temporary Power
20A, 125VACW
Yes (6) Yes (7) No
No
No
No
Distribution Box.
NEMA 5-20R
• Make sure all circuit breakers are in the OFF position
GFCI 20A GFCI Module
Yes (6) Yes (6) Yes (6) Yes (6) Yes (6) Yes (6)
5-20R
• Connect the power supply cord to the power supply then connect the 50A inlet
Certifications
cETLus (conforms to UL
to the power supply cord.
Std. 1640); certified to
Yes
Yes
Yes
Yes
Yes
Yes
• Turn on the main power to the RhinoBox.
CAN/CSA C22.2 No. 14
• Energize circuit breakers by turning to the ON position.
Overload
20A Circuit Breaker
Yes (6) Yes (6) Yes (6) Yes (6) Yes (6) Yes (6)
• Test and reset each GFCI. The power indicator light on each GFCI should be
illuminated.
Protection
30A Circuit Breaker
Yes (1) Yes (1) Yes (1) Yes (1) Yes (1) Yes (1)
• The RhinoBox is now ready for use.
All “200-model” RhinoBox devices (i.e. RB200) are built upon a NEMA 1 enclosure designed for indoor use.
• Additional units may be powered through the 50A receptacle.
All “300-model” RhinoBox devices (i.e. RB300) are built upon a NEMA 3R enclosure designed for outdoor use.
GFCI protection for 30A and 50A outlets upon request.
*(M) denotes Manual reset GFCIs; (A) denotes Automatic reset GFCIs.
**Alternate configuration with 30A, 120VAC, NEMA L5-30R available. Add -L5 suffix to model number.
149C-PTM (REV. D)