Engineering Data Comparison of Specific Applications of Enclosures for Indoor Nonhazardous Locations Enclosure Type Provides a degree of protection against the following environmental conditions Incidental contact with the enclosed equipment Falling Dirt Falling liquids and light splashing Circulating dust, lint, fibers and flyings** Settling airborne dust, lint, fibers and flyings** Hosedown and splashing water Oil and coolant seepage Oil or coolant spraying and splashing Corrosive agents Occasional temporary submersion Occasional prolonged submersion 1* 4 4X 12 12K 13 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X * These enclosures may be ventilated. ** These fibers and flying are nonhazardous materials and are not considered the Class III type ignitable fibers or combustible flyings. For Class III type ignitable fibers or combustible flyings see the National Electrical Code, Article 500. Comparison of Specific Applications of Enclosures for Outdoor Nonhazardous Locations Enclosure Type Engineering Data Provides a degree of protection against the following environmental conditions: Incidental contact with the enclosed equipment Rain, snow and sleet* Sleet** Windblown dust Hosedown Corrosive agents Occasional temporary submersion Occasional prolonged submersion 3 3R*** X X X X X 4 4X X X X X X X X X X * External operating mechanisms are not required to be operable when the enclosure is ice covered. ** External operating mechanisms are operable when the enclosure is ice covered. *** These enclosures may be ventilated. “This material is reproduced by permission of the National Electrical Manufacturers Association from NEMA Standards Publication 250, copyright 1996 by NEMA.” Eaton 460 B-Line series electrical enclosures Engineering Data Comparison Between NEMA Enclosure Type Numbers and IEC Enclosure Classification Designations IEC Publication 529 Classification of Degrees of Protection Provided by Enclosures provides a system for specifying the enclosures of electrical equipment on the basis of degree of protection provided by the enclosure. IEC 529 does not specify degrees of protection against mechanical damage of equipment, risk of explosions, or conditions such as moisture (produced for example by condensation), corrosive vapors, fungus or vermin. NEMA Standards Publication 250 does test for environmental conditions such as corrosion, rust, icing, oil and coolants. For this reason, and because the tests and evaluations for other characteristics are not identical, the IEC Enclosure Classification Designations cannot be exactly equated with NEMA Enclosure Type Numbers. The IEC designation consists of the letters IP followed by two numerals. The first characteristic numeral indicates the degree of protection provided by the enclosure with respect to persons and solid foreign objects entering the enclosure. The second characteristic numeral indicates the degree of protection provided by the enclosure with respect to the harmful ingress of water. Table A-1 provides an equivalent conversion from NEMA Enclosure Type Numbers to IEC Enclosure Classification Designations. The NEMA Types meet or exceed the test requirements for the associated IEC Classifications; for this reason Table A-1 cannot be used to convert from IEC Classifications to NEMA Types. Table A-1 Conversion of NEMA Type Numbers to IEC Classification Designations (Cannot be used to convert IEC Classification Designations to NEMA Type Numbers) NEMA Enclosure Type Number IEC Enclosure Classification Designation 1 IP20 2 IP22 3 IP55 3R IP24 3S IP55 4 and 4X IP66 5 IP53 6 and 6P IP67 12 and 12K IP54 13 IP54 Note: This comparison is based on tests specified in IEC Publication 529. Engineering Data Components Suitable for Closing Openings in Enclosures Enclosure Type Openings shall be closed by equipment rated for enclosure types 3 3, 3S, 4, 4X 3R 3, 3R, 3S, 4, 4X 4 4, 4X 4X 4X 12,12K 12, 12K, 13, 4, 4X 13 13 B-Line series electrical enclosures 461 Eaton