Striplites SNF/SSF Series IAF/ICF Series Narrow and Wide Striplites The new strip family of fixtures is a functional and multi-purpose family that includes a standard body (SSF) and a narrow body (SNF) series that incorporates premium performance and construction durability. Designed with our easy-to-use Flip-Up socket design, the new strip family of fixtures does not require the socket to be attached to the socket track and the end plates to be installed to the channel. The Flip-Up socket simply rotates and locks into place resulting in a significant reduction in installation time and labor cost. SSF Ordering Information . . . . . . . . . . pg. 3-4 SNF Ordering Information . . . . . . . . . . pg. 5-6 IAF/ICF Ordering Information . . . . . . . pg. 7-8 SSF Photometrics. . . . . . . . . . . . . . . . pg. 9-10 SNF Photometrics. . . . . . . . . . . . . . . pg. 11-12 Reflector Ordering Information . . . . . . pg. 13 Options & Accessories . . . . . . . . . . . . . pg. 14 The new strip family can be installed using various mounting methods and numerous options and accessories are available. This family of fixtures can be used in a variety of applications including commercial, industrial, retail and residential applications. Fixtures can be used in storage/utility areas, coves, display cases, shops, task and general area lighting. Features T8 and T5 housings with One, Two or Three lamp configurations Flip-Up socket Designed with our easy-to-use Flip-Up socket design, the new strip family of fixtures does not require the socket to be attached to the socket track and the end plates to be installed to the channel.The Flip-Up socket simply rotates and locks into place resulting in a significant reduction in installation time and labor cost. 1 The SSF and SNF series offer a dedicated housing for T8 and T5 lamping allowing end users to utilize the most current ballast and lamp technologies. The new family of strips is available in one or two lamp configurations and even a three lamp option in the SSF series in both T8 and T5 for those applications that require more light. SSF Series The SSF series standard strip incorporates a 4-1/4” channel and is available in one, two or three lamp configuration utilizing T5, T8, and T12 lamping. Designed with our easy-to-use Flip-Up socket design, the SSF significantly reduces installation time. The performance and application versatility of this series can be increased by incorporating symmetrical or asymmetrical reflectors. The SSF series is ideal for a variety of applications including commercial, industrial, retail and residential applications. SNF Series The SNF series narrow strip incorporates a 2-3/4” channel and is available in a one or two lamp configuration utilizing T5 and T8 lamps and a one lamp configuration utilizing a T12 lamp. Designed with our easy-to-use Flip-Up socket design, the SNF significantly reduces installation time. The performance and application versatility of this series can be increased by incorporating symmetrical or asymmetrical reflectors. The small size of the SNF makes it an ideal choice for size-restricted architectural applications. Standard or Narrow channel The new family of strips is available in two sizes, a standard channel width of 4-1/4" in the SSF series and a narrow channel width of 2-3/4" in the SNF series. This choice of sizes ensures the SSF and the SNF series can be used in a variety of applications including areas that have size restrictions. 2-3/4" [70mm] 4-1/4" [108mm] Narrow (SNF) Standard (SSF) Variety of mounting methods There are a variety of mounting options available for the SSF/SNF family of strips including stem, cable, chain, gripper hanger, tong hanger, and channel connector. The gripper hanger allows for easy mounting to a T-bar grid and can be utilized for stem or surface mounting. The tong hanger is a heavy gauge channel hanger for surface mounting. The CLC channel hanger is a special rigid channel connector designed to give extra support to a continuous channel installation. Gripper 2 Tong Hanger Channel Hanger T8 SSF Ordering Information for T8 S A M P L E N U M B E R : S S F - 2 3 2 - U N V- E B 8 1- U Tandem Blank=2', 3' or 4' Length 8T=8' Length Options GL=Single Element Fuse GM=Double Element Fuse EL4=Emergency Installed (4) EL8=Emergency Installed (8) Series SSF=Commercial Standard Striplite (5) Ballast Type (2) EB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 Number of Lamps (Not Included) 1=1 Lamp 2=2 Lamps 3=3 Lamps (1) Packaging Options (3) RIF1=Radio Interference Suppressor U=Unit Pack 6-3/18 SJT-C&P-515P=Cord & Plug 4B=4 Bulk Packing (48" and 96") (120V), (15 AMP)(6) 6-3/18 SJT-C&P-L715P=Cord & Plug (277V) (15 AMP)(6) PI/CPI=Plug-In Option(6) TILW=Tandem In-Line Wiring Option (Consult TILW Option Catalog Page) (6) A C C E S S O R I E S (Order Separately) EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. No. of Total Harmonic Distortion < 10% Ballast 1 or 2 ER8 = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 ER8 /PLUS= T8 Electronic Program Start. High Ballast Factor >1.13. No. of Total Harmonic Distortion < 10% Ballast 1 or 2 HPT8 Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 max. HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 Wattage 17=17W T8 (24") 25=25W T8 (36") 28T8=28W T8 (48") (7) 32=32W T8 (48") 96T8=59W T8 SL (96") 48T8HO=44W (48") 96T8HO=86W (96") Voltage (2) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 A1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling (Use 2 Per Fixture) GRP-SSF=Gripper Hanger (Use 2 Per Fixture) AYC-Chain/Set=36" Chain Hanger (Use 1 Set Per Fixture) SCF=Fixed Stem Set (Specify Length) SCS=Swivel Stem Set (Specify Length) SCA=Adjustable 48" Stem Set CLC-SSF=Long Channel Connector SSF SSF-ASY-3=3" Asymmetric Reflector (Specify 2', 3', or 4') (9) SSF-REV-3=3" Asymmetric Reverse Reflector SSF (Specify 2', 3', or 4') (9) SSF-SYM-3=6" Symmetric Reflector Specify (2', 3' or 4') SSF-SYM12-4=12" Symmetric Reflector WG/SSF-2FT=2' Wire Guard WG/SSF-3FT=3' Wire Guard WG/SSF-4FT=4' Wire Guard TOGGLE=Single Toggle NO. 2 (Specify Length) Y-TOGGLE=Y Toggle NO. 2 (Specify Length) NOTES: (1) Available in 28T8 and 32 watt. (2) Products also available in non-US voltages and frequencies for international markets. Voltage must be specified when ordered with plugs or emergency ballast. (3) For SilverLining reflector add SS in Catalog Number, Example: SSF-ASY-SS-4. (4) Not available for 2' version. (5) For other emergency options specify manufacturer part number and consult the factory for availability (example: EL-FBP240H). (6) Socket brackets left uninstalled. (7) When utilizing 28W T8 lamps, HPT8 Ballast must be specified. Other ballast restrictions may apply. (8) Available for 96T8, 48T8HO and 96T8HO. (9) For T12 or T8 applications only (no T12 Slimline or T12 HO). Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. T12 SSF Ordering Information for T12 S A M P L E N U M B E R : S S F - 2 2 0 - LT S - 1 2 0 V- U Tandem Blank=2', 3', 4' or 8' Length Series SSF=Commercial Standard Striplite Number of Lamps 1=1 Lamp (Not Included) 2=2 Lamps (Not Included) Wattage 20=20W T12 (24") 30=30W T12 (36") 48=40W T12 SL (48") 48HO=60W T12 HO (48") 96=75W T12 SL (96") 96HO=110W T12 (96") Voltage (1) 120V=120 Volt 277V=277 Volt 347V=347 Volt Options (1) GL=Single Element Fuse GM=Double Element Fuse EL4=Emergency Installed (3) Packaging Options (2) RIF1=Radio Interference Suppressor U=Unit Pack (5) 6-3/18 SJT-C&P-515P=Cord & Plug (120V) (15 AMP) 4B=4 Bulk Packing (5) 6-3/18 SJT-C&P-L715P=Cord & Plug (277V) (15 AMP) (48" and 96") PI/CPI=Plug-In Option(5) TILW=Tandem In-Line Wiring Option (Consult TILW Option Catalog Page) (5) A C C E S S O R I E S (Order Separately) (4) A1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling (Use 2 Per Fixture) GRP-SSF=Gripper Hanger (Use 2 Per Fixture) AYC-Chain/Set=36" Chain Hanger (Use 1 Set Per Fixture) SCF=Fixed Stem Set (Specify Length) SCS=Swivel Stem Set (Specify Length) SCA=Adjustable 48" Stem Set CLC-SSF=Long Channel Connector SSF SSF-ASY-3=3" Asymmetric Reflector (Specify 2', 3', or 4') (6) SSF-REV-3=3" Asymmetric Reverse Reflector SSF (Specify 2', 3', or 4') (6) SSF-SYM-3=6" Symmetric Reflector Specify (2', 3' or 4') SSF-SYM12-4=12" Symmetric Reflector WG/SSF-2FT=2' Wire Guard WG/SSF-3FT=3' Wire Guard WG/SSF-4FT=4' Wire Guard TOGGLE=Single Toggle NO. 2 (Specify Length) Y-TOGGLE=Y Toggle NO. 2 (Specify Length) Ballast Type (1), (4) Blank=Standard Magnetic Ballast LE3=T12 Electronic Ballast EB2 = T12 Electronic Rapid Start. Total Harmonic Distortion < 20% No. of Ballast 1 or 2 Ballast Start Type LTS=Low Trigger Start (20W only) (120V only) HTS=High Trigger Start (20W only) LRS=Low Rapid Start (30W only) (120V only) HRS=High Rapid Start (30W only) (120V only) NOTES: (1) Products also available in non-US voltages and frequencies for international markets. (2) For SilverLining reflector add SS in Catalog Number, Example: SSF-ASY-SS-4. (3) Not available for 2' version. For other emergency options specify manufacturer part number and consult the factory for availability (example: EL-FBP240H). (4) Maximum width clearance for ballast in channel is 2-7/32". (5) Socket brackets left uninstalled. (6) For T12 or T8 applications only (no T12 Slimline or T12 HO). Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. 3 T5 SSF Ordering Information for T5 S A M P L E N U M B E R : S S F - 2 2 4 T 5 - U N V- E B T 1- U Tandem Blank=2' or 4' Length 8T=8' Length Series SSF=Commercial Standard Striplite Number of Lamps (Not Included) 1=1 Lamp 2=2 Lamps 3=3 Lamps Wattage 14T5=14W T5 (24") 24T5=24W T5HO (24") 28T5=28W T5 (48") 54T5=54W T5HO (48") Voltage (1) 347V=347 Volt UNV=Universal Voltage 120-277 Ballast Type (1) EBT Options(1) GL=Single Element Fuse GM=Double Element Fuse EL5=Emergency Installed EL5HO=Emergency Installed for T5HO No. of Ballast 1 or 2 =T5 or T5HO Linear Electronic Program Rapid Start Total Harmonic Distortion < 10% Ballast Factor/Type (For 28W T5 Lamp Only) N=Normal Light Output .95 BF H=High Light Output 1.15 BF (3) NDIM=Normal .95-1.0 BF Step Dimming (4) HDIM=High 1.15 BF Step Dimming (3) (4) NOTES: (1) Products also available in non-US voltages and frequencies for international markets. Voltage must be specified when ordered with plugs or emergency ballast. (2) For SilverLining reflector add SS in Catalog Number, Example: SSF-ASY-SS-4T5. (3) Socket brackets left uninstalled. Consult your Cooper Lighting Representative for availability and ordering information. (4) Step dimming ballast available for 28T5, 14T5 lamps only. Options(2) RIF1=Radio Interference Suppressor 6-3/18 SJT-C&P-515P= Cord & Plug (120V) (15 AMP)(3) 6-3/18 SJT-C&P-L715P=Cord & Plug (277V) (15 AMP)(3) PI/CPI=Plug-In Option(3) TILW=Tandem In-Line Wiring Option (Consult TILW Option Catalog Page) (2) Packaging U=Unit Pack 4B=4 Bulk Packing Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. A C C E S S O R I E S (Order Separately) A1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling (Use 2 Per Fixture) GRP-SSF=Gripper Hanger (Use 2 Per Fixture) AYC-Chain/Set=36" Chain Hanger (Use 1 Set Per Fixture) SCF=Fixed Stem Set (Specify Length) SCS=Swivel Stem Set (Specify Length) SCA=Adjustable 48" Stem Set CLC-SSF=Long Channel Connector SSF SSF-ASY-4T5=3" Asymmetric Reflector (Specify 2' or 4') SSF-REV-4T5 (5) =3" Asymmetric Reverse Reflector SSF (Specify 2', 3', or 4') SSF-SYM-4T5=6" Symmetric Reflector Specify (2' or 4') ICF-4FTT5-REFL(5) =12" Symmetric Reflector T5 WG/SSF-4FT=Wire Guard TOGGLE=Single Toggle NO. 2 (Specify Length) Y-TOGGLE=Y Toggle NO. 2 (Specify Length) standard striplite 4 T8 SNF Ordering Information for T8 S A M P L E N U M B E R : S N F - 2 3 2 - U N V- E B 8 1- U Ballast Type (2), (5) EB8 = T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 Tandem Blank=2', 3' or 4' Length 8T=8' Length Series SNF=Commercial Narrow Striplite Number of Lamps 1=1 Lamp 2=2 Lamp (1) (Not Included) Options(3) RIF1=Radio Interference Suppressor 6-3/18 SJT-C&P-515P=Cord & Plug (120V)(15 AMP)(6) 6-3/18 SJT-C&P L715P= Cord & Plug (277V)(15 AMP)(6) PI/CPI=Plug-In Option(6) ER8 = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 ER8 /PLUS= T8 Electronic Program Start. High Ballast Factor >1.13. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 Wattage 17=17W T8 (24") 25=25W T8 (36") 28T8=28W T8 (48") (7) 32=32W T8 (48") Voltage (2) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 Options GL=Single Element Fuse GM=Double Element Fuse EL4LP=Low Profile Emergency Installed (4) , (5) HPT8 Ballast Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 Packaging U=Unit Pack 6B=6 Bulk Packing (96") A C C E S S O R I E S (Order Separately) AYC-Chain/Set=36" Chain Hanger (Use 1 Set Per Fixture) SCF=Fixed Stem Set (Specify Length) SCS=Swivel Stem Set (Specify Length) SCA=Adjustable 48" Stem Set EYE CHAIN SET/3FT=Eye Bolt Chain (Use 1 Set Per Fixture) SNF-ASY-3=3" Asymmetric Reflector (Specify Length) SNF-SYM-3=6" Symmetric Reflector (Specify Length) SNF-REV=Reverse Asymmetric Reflector WG/SNF-2FT=2' Wire Guard WG/SNF-3FT=3' Wire Guard WG/SNF-4FT=4' Wire Guard A1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling (Use 2 Per Fixture) TOGGLE=Single Toggle NO. 2 (Specify Length) Y-TOGGLE=Y Toggle NO. 2 (Specify Length) NOTES: (1) 2 lamps T8 only. (2) Products also available in non-US voltages and frequencies for international markets. Voltage must be specified when ordered with plugs or emergency ballast. (3) For SilverLining reflector add SS in Catalog Number, Example: SNF-ASY-SS-4. (4) Not available for 2' version. (5) Maximum width clearance for ballast in channel is 2-7/32". (6) Socket brackets left uninstalled. (7) When utilizing 28W T8 lamps, HPT8 Ballast must be specified. Other ballast restrictions may apply. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. T12 SNF Ordering Information for T12 S A M P L E N U M B E R : S N F - 1 2 0 - LT S - 1 2 0 V- U Tandem Blank=18", 2' or 3' Length Voltage (1) 120V=120 Volt 277V=277 Volt Series SNF=Commercial Narrow Striplite Options GL=Single Element Fuse GM=Double Element Fuse EL4LP=Low Profile Emergency Installed (3) (4) Number of Lamps 1=1 Lamp (Not Included) Wattage 15=15W T12 (18") 20=20W T12 (24") 30=30W T12 (36") Ballast Start Type LTS=Low Trigger Start (20W only) (120V only) HTS=High Trigger Start (20W only) LRS=Low Rapid Start (30W only) (120V only) HRS=High Rapid Start (30W only) (120V only) Options (2) RIF1=Radio Interference Suppressor 6-3/18 SJT-C&P-515P=Cord & Plug (120V) (15 AMP)(5) 6-3/18 SJT-C&P-L715P=Cord & Plug (277V) (15 AMP)(5) PI/CPI=Plug-In Option(5) Packaging U=Unit Pack 6B=6 Bulk Packing (96") A C C E S S O R I E S (Order Separately) A1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling (Use 2 Per Fixture) GRP-SSF=Gripper Hanger (Use 2 Per Fixture) AYC-Chain/Set=36" Chain Hanger (Use 1 Set Per Fixture) SCF=Fixed Stem Set (Specify Length) SCS=Swivel Stem Set (Specify Length) SCA=Adjustable 48" Stem Set SNF-ASY-3=3" Asymmetric Reflector (Specify 2', 3', or 4') SNF-REV-3=3" Asymmetric Reverse Reflector SSF (Specify 2', 3', or 4') SNF-SYM-3=6" Symmetric Reflector Specify (2', 3' or 4') WG/SNF-2FT=2' Wire Guard WG/SNF-3FT=3' Wire Guard WG/SNF-4FT=4' Wire Guard TOGGLE=Single Toggle NO. 2 (Specify Length) Y-TOGGLE=Y Toggle NO. 2 (Specify Length) Ballast Type (1), (4) Blank=Standard Magnetic Ballast LE3=T12 Magnetic Energy Saving EB2 = T12 Electronic Rapid Start. Total Harmonic Distortion < 20% (30 Watt only) No. of Ballast 1 or 2 NOTES: (1) Products also available in non-US voltages and frequencies for international markets. (2) For SilverLining reflector add SS in Catalog Number, Example: SNF-ASY-SS-4. (3) Not available for 2' version. (4) Maximum width clearance for ballast in channel is 2-7/32". (5) Socket brackets left uninstalled. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. 5 T5 SNF Ordering Information for T5 S A M P L E N U M B E R : S N F - 2 2 8 T 5 - U N V- E B T 1- U Tandem Blank=2' or 4' Length 8T=8' Length Number of Lamps 1=1 Lamp 2=2 Lamp (Not Included) Series SNF=Commercial Narrow Striplite Wattage 14T5=14W T5 (24") 24T5=24W T5HO (24") 28T5=28W T5 (48") 54T5=54W T5HO (48") Voltage (1) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 Ballast Type (1), (4) EBT No. of Ballast 1 or 2 Options GL=Single Element Fuse GM=Double Element Fuse EL5=Emergency Installed (3) , (4) EL5HO=Emergency Installed for T5HO = T5 or T5HO Linear Electronic Program Rapid Start. Total Harmonic Distortion < 10% Ballast Factor/Type (For 28W T5 and 14WT5 Lamps Only) N=Normal Light Output .95 BF (1) H=High Light Output 1.15 BF (1), (6) NDIM=Normal .95-1.0 BF Step Dimming (7) HDIM=High 1.15 BF Step Dimming (6), (7) Options(2) RIF1=Radio Interference Suppressor 6-3/18 SJT-C&P-515P=Cord & Plug (120V)(15 AMP)(5) 6-3/18 SJT-C&P L715P= Cord & Plug (277V)(15 AMP)(5) PI/CPI=Plug-In Option(5) Packaging U=Unit Pack 6B=6 Bulk Packing (96") A C C E S S O R I E S (Order Separately) NOTES: (1) Products also available in non-US voltages and frequencies for international markets. Voltage must be specified when ordered with plugs or emergency ballast. (2) For SilverLining reflector add SS in Catalog Number, Example: SNF-ASY-SS-4T5. (3) Not available for 2' version. (4) Maximum width clearance for ballast in channel is 27/32". (5) Socket brackets left uninstalled. (6) 1-Lamp ballast in the High Ballast factor not available. 2-Lamp ballast will not operate 1-Lamp. (7) Step Dimming ballast available for 28W T5 and 14WT5 lamps only. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. AYC-Chain/Set=36" Chain Hanger (Use 1 Set Per Fixture) SCF=Fixed Stem Set (Specify Length) SCS=Swivel Stem Set (Specify Length) SCA=Adjustable 48" Stem Set EYE CHAIN SET/3FT=Eye Bolt Chain (Use 1 Set Per Fixture) SNF-ASY-3=3" Asymmetric Reflector (Specify Length) SNF-SYM-3=6" Symmetric Reflector (Specify Length) SNF-REV-3=Reverse Asymmetric Reflector WG/SNFT5-4FT=Wire Guard A1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling (Use 2 Per Fixture) TOGGLE=Single Toggle NO. 2 (Specify Length) Y-TOGGLE=Y Toggle NO. 2 (Specify Length) narrow striplite 6 T8 & T12 HO Tandem Blank=4'Length 8T=8' Length Series IAF=Apertured Reflector ICF=Closed Top Reflector SilverLining SS=Silver-Lining Housing and Ballast Cover (5) Number of Lamps 2=Lamps (Not Included) Wattage 28T8=28W T8 (48") (4) 32=32W T8 (48") 48HO=60W T12 (48") HO 48T8HO=44W T8 (48") HO 96HO=95/110W T12 (96") HO 96T8HO=86W T8 (96") HO 48=40W T12 (48") SL 96=60/75W T12 (72") SL 96=59W T8 (96") SL Voltage (1) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (2) IAF/ICF Ordering Information for T8 & High Output S A M P L E N U M B E R : I A F - 2 9 6 T 8 H O - 1 2 0 V- E B 8 1- U Ballast Type (1) EB8 = T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 ER8 = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 ER8 /PLUS= T8 Electronic Program Start. High Ballast Factor >1.13. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB2 =T12 Electronic Rapid Start. No. of Ballast 1 or 2 Options Packaging RIF1=Radio Interference Suppressor U=Unit Pack 6-3/18 SJT-C&P-515P=Cord & Plug 4B=4 Bulk (120V), (15 AMP) (3) 6-3/18 SJT-C&P-L715P=Cord & Plug (277V), (15 AMP)(3) PI/CPI=Plug-In Option(4) TILW=Tandem In-Line Wiring Option (Consult TILW Option Catalog Page)(3) (See options & accessories) A C C E S S O R I E S (Order Separately) A-1-B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling (Use 2 per fixture) GRP-SSF=Gripper Hanger (Use 2 per fixture) SCF=Fixed Stem Set (Specify Length) SCS=Swivel Stem Set (Specify Length) SCA=Adjustable 48" Stem Set AYC-Chain/Set-U=Chain Hanger Set (Use 1 set per fixture) WG/ICF-4FT-U2 =Wire Guard CLC-SSF=Long Channel Connector SSF TOGGLE=Single Toggle NO. 2 (Specify Length) Y-TOGGLE=Y Toggle NO. 2 (Specify Length) HPT8 Ballast Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 Options GL=Single Element Fuse GM=Double Element Fuse EL4=Emergency Installed EL8=Emergency Installed closed top reflector 7 NOTES: (1) Products also available in non-US voltages and frequencies for international markets. (2) Not available when specifying emergencies, voltage must be specific. Exception EL4. (3) Socket brackets left uninstalled. (4) When utilizing 28W T8 lamps, HPT8 Ballast must be specified. (5) Not available with HO lamps. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. T5 IAF/ICF Ordering Information for T5 S A M P L E N U M B E R : I A F - 2 2 8 T 5 - U N V- E B 8 1- U Tandem Blank=4'Length 8T=8' Length Series IAF=Apertured Reflector ICF=Closed Top Reflector SilverLining SS=Silver-Lining Housing and Ballast Cover Number of Lamps 2=Lamps (Not Included) Wattage 28T5=28W T5 (48") 54T5=54W T5HO (48") Voltage (1) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (2) Options GL=Single Element Fuse GM=Double Element Fuse EL5=Emergency Installed EL5HO=Emergency Installed for T5HO Ballast Type (1) EBT No. of Ballast 1 or 2 Options RIF1=Radio Interference Suppressor 6-3/18 SJT-C&P-515P=Cord & Plug (120V), (15 AMP)(4) 6-3/18 SJT-C&P-L715P=Cord & Plug (277V), (15 AMP)(3) PI/CPI=Plug-In Option(3) TILW=Tandem In-Line Wiring Option (Consult TILW Option Catalog Page)(3) Packaging U=Unit Pack 4B=4 Bulk (See options & accessories) A C C E S S O R I E S (Order Separately) A-1-B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling (Use 2 per fixture) = T5 or T5HO Linear Electronic Program Rapid Start. Total Harmonic Distortion < 10% Ballast Factor/Type (For 28W T5 and 14WT5 Lamps Only) N=Normal Light Output .95 BF (1) H=High Light Output 1.15 BF (1), (4) NDIM=Normal .95-1.0 BF Step Dimming (5) HDIM=High 1.15 BF Step Dimming (4), (5) GRP-SSF=Gripper Hanger (Use 2 per fixture) SCF=Fixed Stem Set (Specify Length) SCS=Swivel Stem Set (Specify Length) SCA=Adjustable 48" Stem Set AYC-Chain/Set-U=Chain Hanger Set (Use 1 set per fixture) WG/ICF-4FT-U2 =Wire Guard CLC-SSF=Long Channel Connector SSF TOGGLE=Single Toggle NO. 2 (Specify Length) Y-TOGGLE=Y Toggle NO. 2 (Specify Length) NOTES: (1) Products also available in non-US voltages and frequencies for international markets. (2) Not available when specifying emergencies, voltage must be specific. (3) Socket brackets left uninstalled. (4) 1-Lamp ballast in the High Ballast factor not available. 2-Lamp ballast will not operate 1-Lamp. (5) Step Dimming ballast available for 28W T5 and 14WT5 lamps only. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. open top reflector 8 SSF-T8 Photometrics C o e ff i c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 SSF-228T8 Electronic Ballast F28T8-SP35-UMX-ECO Lamps 2750 Lumens Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.5 x mounting height Efficiency 86.2% Test Report: SSF228T8.IES LER = FS-95 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 99 88 79 71 64 59 54 50 46 43 40 99 83 70 61 53 47 42 38 34 31 29 99 78 63 53 45 38 34 30 26 24 22 99 74 57 46 38 32 28 24 21 19 17 95 84 75 67 61 56 51 48 44 41 39 95 79 67 58 51 45 40 36 33 30 28 95 75 61 51 43 37 33 29 26 23 21 95 71 56 45 37 31 27 23 21 18 17 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 88 73 62 53 47 42 37 34 31 28 26 81 67 57 49 43 38 34 31 28 26 24 75 62 52 45 40 35 32 29 26 24 23 73 55 43 35 29 24 21 18 16 14 13 88 69 57 47 40 35 31 27 24 22 20 88 66 52 42 35 30 26 22 20 18 16 81 64 53 44 38 33 29 26 23 21 19 81 62 49 40 33 28 24 21 19 17 15 75 60 49 41 35 31 27 24 22 20 18 75 58 46 37 31 27 23 20 18 16 14 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens %Lamp %Fixture 758 1291 2533 3988 751 4739 13.8 23.5 46.1 72.5 13.6 86.2 16.0 27.2 53.5 84.2 15.8 100.0 45° 929 928 925 914 899 888 876 860 837 808 771 727 675 632 598 554 443 340 234 Across⊥ 929 927 928 927 936 945 949 946 934 915 889 866 845 818 775 674 568 453 349 Angle Along II 45° 1017 1017 0 1007 1010 5 949 985 10 857 951 15 738 906 20 588 830 25 422 727 30 252 632 35 104 456 40 0 253 45 0 320 50 0 246 55 0 199 60 0 131 65 0 69 70 0 17 75 0 1 80 0 0 85 0 0 90 Across⊥ 1017 1021 1030 1042 1029 978 920 834 601 393 518 430 353 263 167 76 7 0 0 Angle Along II 929 0 927 5 916 10 896 15 869 20 834 25 792 30 742 35 687 40 627 45 561 50 492 55 418 60 340 65 261 70 181 75 106 80 41 85 5 90 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.53 C o e ff i c i e n t s o f U t i l i z a t i o n SSF-232 Electronic Ballast FO32T8 Lamps 2900 Lumens Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.6 x mounting height Efficiency 91.6% Test Report: SSF232.IES LER = FS-88 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 105 93 83 75 68 62 57 53 49 46 43 92 76 65 56 49 44 39 35 32 30 27 84 70 59 51 45 40 36 33 30 27 25 77 64 54 47 41 37 33 30 27 25 23 74 56 44 36 30 25 22 19 17 15 13 105 87 74 64 56 50 44 40 36 33 30 105 83 67 56 48 41 36 32 28 25 23 105 78 61 49 41 35 30 26 23 20 18 100 100 100 100 88 84 79 75 79 71 65 59 71 62 54 48 65 54 46 40 59 48 40 34 54 43 35 29 50 38 31 25 47 35 27 22 44 32 25 20 41 29 22 18 92 73 60 50 43 37 32 29 26 23 21 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens %Lamp %Fixture 830 1411 2753 4288 1023 5311 14.3 24.3 47.5 73.9 17.6 91.6 15.6 26.6 51.8 80.7 19.3 100.0 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.73 9 92 70 55 45 37 32 27 24 21 19 17 84 67 55 46 39 34 30 27 24 22 20 84 64 51 42 35 30 26 22 20 18 16 77 61 51 42 36 32 28 25 22 20 18 77 59 47 39 32 28 24 21 19 17 15 SSF-T5 Photometrics C o e ff i c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 SSF-228T5-UNV-EBT1 Electronic Ballast F28T5/835 Lamps 2600 Lumens Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.5 x mounting height Efficiency 96.5% Test Report: 122P106 LER = FS-78 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.07 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 111 98 88 79 72 66 61 56 52 48 45 111 92 78 68 59 52 47 42 38 35 32 111 87 71 59 50 43 38 33 30 27 24 111 82 64 52 43 36 31 27 24 21 19 106 106 106 106 93 88 83 79 83 75 68 62 75 65 57 50 68 57 48 42 62 50 42 35 57 45 37 30 53 41 32 26 49 37 29 23 46 34 26 21 43 31 24 19 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Candela 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 98 81 69 59 52 46 42 38 34 31 29 90 74 63 54 48 43 38 35 32 29 27 83 68 58 50 44 39 35 32 29 27 25 79 60 47 38 32 27 23 20 18 16 14 98 77 63 53 45 39 34 30 27 25 22 98 74 58 47 39 33 29 25 22 20 18 90 71 58 49 42 36 32 28 26 23 21 90 68 54 44 37 31 27 24 21 19 17 83 66 54 45 39 34 30 27 24 22 20 83 63 50 41 35 30 26 22 20 18 16 Ty p i c a l VC P Pe r c e n t a g e s Lumens %Lamp %Fixture 805 1360 2634 4129 888 5016 15.5 26.1 50.6 79.4 17.1 96.5 16.1 27.1 52.5 82.3 17.7 100.0 Height Along 8.5’ 10.0’ 28 38 18 25 15 20 15 20 11 14 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Height Across 8.5’ 10.0’ 16 25 8 13 3 5 10 15 4 6 C o e ff i c i e n t s o f U t i l i z a t i o n 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 112 99 89 80 73 66 61 56 52 49 46 99 82 70 60 53 47 42 38 35 32 29 91 75 64 55 48 43 39 35 32 29 27 84 69 58 51 44 40 36 32 30 27 25 81 61 48 39 32 27 23 20 18 16 14 SSF-254T5-UNVEBT1 Electronic Ballast F54T5/835 Lamps 4400 Lumens Zonal Lumen Summary Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.5 x mounting height Efficiency 97.3% Test Report: 122P108 LER = FS-73 Zone 0-30 0-40 0-60 0-90 90-180 0-180 112 93 79 68 60 53 47 43 39 35 32 112 88 71 59 50 43 38 34 30 27 24 112 83 65 52 43 36 31 27 24 21 19 107 107 107 107 94 89 84 80 84 76 69 63 76 65 57 51 69 57 49 42 63 51 42 36 58 45 37 31 54 41 33 27 50 37 29 23 47 34 26 21 44 31 24 19 99 78 64 53 45 39 35 31 27 25 23 99 74 59 48 40 34 29 25 22 20 18 91 72 59 49 42 37 32 29 26 23 21 91 69 55 45 37 32 27 24 21 19 17 84 67 55 46 39 34 30 27 24 22 20 84 64 51 42 35 30 26 23 20 18 16 Ty p i c a l VC P Pe r c e n t a g e s Lumens %Lamp %Fixture 1376 2326 4516 7118 1448 8565 15.6 26.4 51.3 80.9 16.4 97.3 16.1 27.2 52.7 83.1 16.9 100.0 45° 973 979 982 977 964 945 920 887 853 821 787 749 699 639 586 535 506 373 223 Across⊥ 973 978 990 994 995 987 978 971 964 950 927 890 852 812 772 756 670 494 345 45° 1661 1672 1675 1666 1647 1616 1575 1521 1461 1405 1348 1285 1209 1109 1011 929 871 654 395 Across⊥ 1661 1670 1689 1698 1699 1690 1674 1661 1645 1623 1589 1535 1467 1401 1332 1298 1135 855 603 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Angle Along II 973 0 979 5 972 10 955 15 926 20 887 25 840 30 783 35 720 40 650 45 574 50 496 55 414 60 330 65 244 70 161 75 87 80 29 85 1 90 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.28 10 Height Along 8.5’ 10.0’ 16 24 10 14 8 10 8 11 5 8 Height Across 8.5’ 10.0’ 8 14 4 7 1 2 5 8 2 3 Angle Along II 1661 0 1672 5 1661 10 1631 15 1584 20 1518 25 1439 30 1345 35 1239 40 1122 45 997 50 867 55 731 60 591 65 448 70 306 75 171 80 60 85 3 90 SNF-T8 Photometrics C o e ff i c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 SNF-132 Electronic Ballast F32T8/35K Lamps 2900 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.5 x mounting height Efficiency 93.4% Test Report: SNF132.IES LER = FS-19 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 107 94 84 76 69 63 58 53 49 45 42 94 77 66 57 50 44 39 35 31 28 26 86 71 60 52 46 40 36 32 29 26 24 79 64 54 47 42 37 33 29 26 24 22 76 57 44 36 30 25 21 18 15 13 11 107 89 75 65 57 50 44 40 36 32 29 107 84 68 57 48 41 35 31 27 24 21 107 79 61 50 41 34 29 25 21 18 16 102 102 102 102 90 85 80 76 80 72 65 59 72 62 55 48 66 55 47 40 60 48 39 33 55 43 34 28 50 38 30 24 46 34 26 21 43 31 23 18 40 28 21 16 94 74 60 51 43 37 32 28 24 21 19 94 70 55 45 38 31 27 23 20 17 15 86 68 55 47 40 34 30 26 23 20 18 86 65 51 42 35 29 25 21 18 16 14 79 62 51 43 37 31 27 24 21 19 17 79 60 48 39 33 27 23 20 17 15 13 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens %Lamp %Fixture 391 662 1307 2192 515 2708 13.5 22.8 45.1 75.6 17.8 93.4 14.4 24.5 48.3 81.0 19.0 100.0 Angle Along II 481 0 474 5 448 10 405 15 347 20 278 25 201 30 120 35 44 40 2 45 2 50 2 55 2 60 3 65 0 70 0 75 0 80 0 85 0 90 45° 481 478 468 447 421 393 367 332 278 237 213 120 38 2 0 0 0 0 0 Across⊥ 481 479 481 479 480 481 474 449 408 368 367 259 144 42 0 0 0 0 0 45° 990 989 986 977 959 938 918 896 868 835 797 747 689 628 564 496 413 333 272 Across⊥ 990 988 992 989 990 994 996 992 982 957 922 878 829 775 716 643 566 484 421 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.04 C o e ff i c i e n t s o f U t i l i z a t i o n SNF-232 Electronic Ballast FO32T8 Lamps 2800 Lumens Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.6 x mounting height Efficiency 90.1% Test Report: SNF232.IES LER = FS-77 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 103 91 82 74 67 62 57 52 49 45 42 90 75 64 55 49 43 39 35 32 29 27 83 68 58 51 44 40 36 32 29 27 25 76 62 53 46 41 36 33 30 27 25 23 72 55 44 35 30 25 22 19 17 15 13 103 86 73 64 56 49 44 40 36 33 30 103 81 66 55 47 41 36 31 28 25 23 103 77 60 49 41 34 30 26 23 20 18 99 87 78 70 64 58 54 50 46 43 40 99 82 70 61 53 47 42 38 35 32 29 99 78 64 53 45 39 34 30 27 25 22 99 74 58 47 39 33 29 25 22 20 18 90 72 59 49 42 37 32 28 25 23 21 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens %Lamp %Fixture 805 1364 2639 4050 994 5044 14.4 24.4 47.1 72.3 17.7 90.1 16.0 27.0 52.3 80.3 19.7 100.0 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.11 11 90 68 54 44 37 31 27 24 21 19 17 83 66 54 45 39 34 30 27 24 22 20 83 63 50 41 35 29 25 22 20 18 16 76 60 50 42 36 31 28 25 22 20 18 76 58 47 38 32 27 24 21 19 17 15 Angle Along II 990 0 988 5 975 10 954 15 925 20 885 25 836 30 780 35 717 40 647 45 573 50 495 55 414 60 332 65 248 70 167 75 92 80 30 85 1 90 SNF-T5 Photometrics C o e ff i c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 SNF-228T5-UNV-EBT1 Electronic Ballast F28T5/835 Lamps 2600 Lumens Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.5 x mounting height Efficiency 97.8% Test Report: 122P109 LER = FS-79 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.03 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 112 99 89 80 73 67 61 57 53 49 46 98 81 69 60 53 47 42 38 34 32 29 89 74 63 55 48 43 38 35 32 29 27 81 67 57 50 44 39 35 32 29 27 25 78 59 47 38 32 27 23 20 18 16 14 112 93 80 69 60 53 48 43 39 35 33 112 88 72 60 51 44 38 34 30 27 25 112 84 66 53 44 37 32 28 24 22 19 107 107 107 107 94 89 85 80 84 76 69 63 76 66 58 51 69 58 49 43 63 51 42 36 58 46 37 31 54 41 33 27 50 37 29 24 46 34 26 21 43 31 24 19 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Candela 98 78 64 53 45 39 35 31 27 25 22 98 74 59 48 40 34 29 25 22 20 18 89 71 58 49 42 36 32 28 26 23 21 89 68 55 45 37 32 27 24 21 19 17 81 65 54 45 39 34 30 26 24 22 20 81 63 50 41 35 29 26 22 20 18 16 Ty p i c a l VC P Pe r c e n t a g e s Lumens %Lamp %Fixture 799 1349 2628 4046 1039 5085 15.4 25.9 50.5 77.8 20.0 97.8 15.7 26.5 51.7 79.6 20.4 100.0 Height Along 8.5’ 10.0’ 18 27 12 16 10 13 10 14 8 10 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Height Across 8.5’ 10.0’ 9 16 5 8 2 3 7 10 3 4 C o e ff i c i e n t s o f U t i l i z a t i o n SNF-154T5-UNV-EBT1 Electronic Ballast F54T5/835 Lamps 4400 Lumens Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.5 x mounting height Efficiency 94.6% Test Report: 122P112 LER = FS-67 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.58 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 108 95 85 77 70 64 59 54 50 47 44 94 77 66 57 50 44 40 36 33 30 28 86 70 59 51 45 40 36 33 30 28 25 79 64 54 47 41 37 33 30 27 25 23 75 55 44 35 29 25 21 19 16 15 13 108 84 68 57 48 42 36 32 29 26 23 108 79 62 50 41 35 30 26 23 20 18 103 103 103 103 90 85 80 76 80 72 65 59 73 62 54 48 66 55 46 40 60 48 40 34 56 43 35 29 51 39 31 25 48 36 28 22 45 33 25 20 42 30 23 18 Zone 0-30 0-40 0-60 0-90 90-180 0-180 94 73 60 50 43 37 33 29 26 23 21 94 70 55 45 37 32 27 24 21 19 17 86 67 55 46 39 34 30 27 24 22 20 86 64 51 41 35 29 25 22 20 18 16 79 61 50 42 36 31 28 25 22 20 19 79 59 47 38 32 27 24 21 19 17 15 Ty p i c a l VC P Pe r c e n t a g e s Zonal Lumen Summary Lumens %Lamp %Fixture 631 1062 2041 3304 858 4161 14.3 24.1 46.4 75.1 19.5 94.6 15.2 25.5 49.0 79.4 20.6 100.0 45° 955 962 970 973 964 945 915 877 844 812 784 757 714 666 608 513 414 305 223 Across⊥ 955 959 981 991 991 976 967 962 961 959 942 913 893 829 745 654 534 433 346 45° 764 770 772 767 756 740 721 694 661 626 593 560 530 500 471 434 386 353 328 Across⊥ 764 767 774 776 776 771 757 739 725 711 699 686 673 659 631 591 557 532 507 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 108 89 76 65 57 51 45 41 37 34 31 Angle Along II 955 0 963 5 957 10 939 15 911 20 873 25 826 30 771 35 708 40 639 45 566 50 489 55 409 60 326 65 242 70 161 75 88 80 33 85 2 90 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 12 Height Along 8.5’ 10.0’ 23 33 14 19 11 15 11 16 8 11 Height Across 8.5’ 10.0’ 12 20 6 10 2 3 7 12 2 3 Angle Along II 764 0 768 5 763 10 750 15 728 20 698 25 662 30 619 35 570 40 517 45 461 50 403 55 342 60 280 65 216 70 152 75 90 80 34 85 1 90 SNF SNF Strip Series SNF=Narrow Reflector Ordering Information ASY SS NOTES: (1) For SNF only. (2) Will ship as (2) 4 ft. reflectors. (3) For SSF only. (4) For slimline or T12HO (2 Lamp only). (5) For T12 or T8 applications only (no T12 Slimline or T12 HO). 4 Reflector Style Finish ASY=Asymmetric (5) Blank=White SYM=Symmetric SS=Specular Steel SYM12=12" Symmetric (3) REV=Reverse Asymmetric (5) Length 18=18 Inch (1) 2=2 Foot 2T5=2 Foot T5 3=3 Foot 4=4 Foot 4T5=4 Foot T5 8T=8 Foot (2) 8T5=8 Foot T5 For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. 3" SNF ASY Reflector 3" SNF REV/ASY Reflector WHITE SPECULAR SNF-ASY-18IN SNF-ASY-2 SNF-ASY-3 SNF-ASY-4 SNF-ASY-8T SNF-ASY-2T5 SNF-ASY-4T5 SNF-ASY-8T5 SNF-ASY-SS-18IN SNF-ASY-SS-2 SNF-ASY-SS-3 SNF-ASY-SS-4 SNF-ASY-SS-8T-2 SNF-ASY-SS-2T5 SNF-ASY-SS-4T5 SNF-ASY-SS-8T5 SSF SSF Strip Series SSF=Standard WHITE SNF-REV-2 SNF-REV-3 SNF-REV-4 SNF-REV-8T SNF-REV-2T5 SNF-REV-4T5 SNF-REV-8T5 SPECULAR SNF-REV-SS-2 SNF-REV-SS-3 SNF-REV-SS-4 SNF-REV-SS-8T SNF-REV-SS-2T5 SNF-REV-SS-4T5 SNF-REV-SS-8T5 WHITE SNF-SYM-18IN SNF-SYM-2 SNF-SYM-3 SNF-SYM-4 SNF-SYM-8T 6" SPECULAR SNF-SYM-SS-18IN SNF-SYM-SS-2 SNF-SYM-SS-3 SNF-SYM-SS-4 SNF-SYM-SS-8T Reflector Ordering Information ASY SS Reflector Style Finish ASY=Asymmetric (5) Blank=White SYM=Symmetric SS=Specular Steel SYM12=12" Symmetric (3) REV=Reverse Asymmetric (5) NOTES: (1) For SNF only. (2) Will ship as (2) 4 ft. reflectors. (3) For SSF only. (4) For slimline or T12HO (2 Lamp only). (5) For T12 or T8 applications only (no T12 Slimline or T12 HO). 4 Length 18=18 Inch (1) 2=2 Foot 2T5=2 Foot T5 3=3 Foot 4=4 Foot 4T5=4 Foot T5 8T=8 Foot (2) 8T5=8 Foot T5 For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. 3" SSF ASY Reflector WHITE SSF-ASY-2 SSF-ASY-3 SSF-ASY-4 SSF-ASY-8T SSF-ASY-2T5 SSF-ASY-4T5 SSF-ASY-8T5 SNF SYM Reflector 3" SPECULAR SSF-ASY-SS-2 SSF-ASY-SS-3 SSF-ASY-SS-4 SSF-ASY-SS-8T SSF-ASY-SS-2T5 SSF-ASY-SS-4T5 SSF-ASY-SS-8T5 SSF REV/ASY Reflector WHITE SSF-REV-2 SSF-REV-3 SSF-REV-4 SSF-REV-8T SSF-REV-2T5 SSF-REV-4T5 SSF-REV-8T5 SPECULAR SSF-REV-SS-2 SSF-REV-SS-3 SSF-REV-SS-4 SSF-REV-SS-8T SSF-REV-2T5 SSF-REV-4T5 SSF-REV-8T5 13 SSF SYM Reflector WHITE SSF-SYM-2 SSF-SYM-2T5 SSF-SYM-3 SSF-SYM-4 SSF-SYM-4T5 SSF-SYM-8T SSF-SYM-8TT5 SSF-SYM-4HO (4) SSF-SYM-8HO (4) SSF-SYM12-4 SSF-SYM12-4HO SSF-SYM12-8 SSF-SYM12-8HO 6" SPECULAR SSF-SYM-SS-2 SSF-SYM-SS-2T5 SSF-SYM-SS-3 SSF-SYM-SS-4 SSF-SYM-SS-4T5 SSF-SYM-SS-8T SSF-SYM-SS-28TT5 SSF-SYM-SS-4HO SSF-SYM-SS-8HO SSF-SYM12-SS-4 SSF-SYM12-SS-4HO SSF-SYM12-SS-4 SSF-SYM12-SS-8HO SNF/SSF Options & Accessories MOUNTING D E S I G N AT I O N DESCRIPTION Gripper Hanger GRP-SSF-U (Use with SSF, IAF/ICF) using 11/16" hole provided. For mounting on T-bar grid. Use two per fixture. Can also be stem mounted or bolted to surface Fixture spacing 1-1/2". GRP-STN-U (Use with STM, DIM) GRP-SNF-U (Use with SNF, not suitable for stem mounted or bolted to surface) Tong Hanger ATG SSF-4-U (Use with SSF, IAF/ICF) Heavy Gauge Channel Tong Hanger. Use two per fixture. Fixture spacing 1-1/2". ATG SNF-4-U (Use with SNF) Spacer A-1-B/Spacer-U (Use with all Strips and Industrials) Spaces fixture 1-1/2" to 2-1/2" from ceiling Suspension Sets/Stem Sets CCF SCF-XX-U - Fixed Stem Set SCS-XX-U - Swivel Stem Set (Deep canopy, 3/8" IPS stem, 5/8" outside diameter) XX= Length 6, 8, 12, 24, 36, 48, 60, 72 SCF SCS Type of Kit CCA=Adjustable Cable Kit CCF=Fixed Length Cable Kit SCA SCA-48-U - Adjustable Stem Set (1/4" IPS Stem, 1/2" Outside Diameter). Used with all surface fixtures as stem sets. SCS stems have 45° swivel, one direction. One set consists of one stem assembly. Minimum of two sets required per fixture. NOTE: Coupler, 3/8" IPS Pipe Coupler to join lengths. Coupler is standard baked white enamel or special order of black. Chain Hanger Channel Connector 18 Length of Cable Fixed Length 12=12" Long 15=15" Long 18=18" Long 21=21" Long 24=24" Long 27=27" Long 48=48" Long Adjustable 120=120" Long NPF Configuration NPF=Non Power Feed PFS=Straight Cord Power PFC=Curly Cord Power Feed CCA PFC CCA PFS CCA NPF AYC-Chain/Set-U (Use with all strips and industrials except STW) Sturdy wire hook and 36" chain set. Use two per fixture. One set of two provided Eye Chain Set/3 Ft. (SNF only) Eye bolt and 36" chain. Use two per fixture. One set of two provided CLC-SSF-B (LA City Approved) CLC-SSF-EXT-B (External Connector SSF) (1) CLC-SNF-EXT-B (Long Connector SNF) (1) Special rigid channel connector designed to give extra support to continuous channel installation (Use with SSF, IAF/ICF). Provision for hanging device. NOTES: (1) Not recommended with wire guard. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Items listed are the major accessories available on Metalux Recessed (Parabolic and Recessed) and Surface Fixtures. Additional options and accessories are available. Consult Pre-Sales Technical Support for additional information. 14 Cooper Lighting, LLC. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 International Sales, USA Cooper Lighting, LLC. 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 F: 770-486-4801 P: 770-486-4800 F: 770-486-4801 www.cooperlighting.com Canada Cooper Lighting, LLC. 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 P: 905-507-4000 F: 905-568-7049 Domestic Facilities Cranbury, New Jersey Elk Grove Village, Illinois Irving, Texas Ontario, California Peachtree City, Georgia Canadian Facility Calgary, Alberta T2E 7V9 Mississauga, Ontario L5R 1B8 Cooper Lighting and Metalux are valuable trademark of Cooper Industries in the United States and other countries. You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries. Cooper Industries, Ltd. 600 Travis, Ste. 5800 Houston, TX 77002-1001 P: 713-209-8400 www.cooperindustries.com ADF090667 Printed in USA The Cooper Lighting Family Halo Metalux Lumark Sure-Lites Neo-Ray Corelite Portfolio Iris Shaper io Lumière Invue McGraw-Edison Streetworks Fail-Safe PDS MWS RSA Ametrix