High capacity surge protective devices for switchboards BUSSMANN SERIES

BUSSMANN
SERIES
BSPD surge protective devices
High capacity surge protective devices
for switchboards
Product description:
Features and benefits:
Eaton’s Bussmann series
BSPD Surge Protective
Devices (SPDs) help protect
electrical and electronic
equipment from overvoltage
surges. What’s more, they
enable compliance with 2014
NEC® 700.8 that requires a
listed SPD to be installed
in or on all emergency
system switchboards and
panelboards.
•
®
Bussmann series
high current capacity
SPDs deliver reliable
surge protection for
switchboards and
power distribution
panels.
The RoHS compliant
BSPD uses thermally
protected Bussmann series
SurgePOD™ technology to
safely shunt overvoltages
to ground while its thermal
disconnect capability
eliminates the need for
additional fusing.
120kA to 400kA surge
current capacity
ratings (Imax) meet the
requirements of larger
switchboards and
electrical panels.
•UL® maximum 20kA
nominal discharge
current rating (In) and
200kA Short-Circuit
Current Rating (SCCR)
meet most system
requirements.
•
easyID™ LED indicators
provide surge protection
status at a glance.
•
Available Form C
contact, EMI/RFI
filtering and surge
counter options to meet
specific application
requirements.
NEMA® 1 enclosure
Prewired and factory sealed for easy
installation and enhanced electrical
safety.
NEMA 4X enclosure
304 stainless steel housing meets the
needs of demanding environments
and also comes prewired and factory
sealed for easy installation and
enhanced electrical safety.
Value features:
All BSPD units are UL Listed 1449 3rd Edition SPDs with Bussmann
series SurgePOD thermally protected MOV technology that delivers
reliable surge protection with high surge current capacity. Every
BSPD unit is factory sealed to enhance safety by preventing access
to energized parts, and eliminate arc flash and shock hazards. All
units are prewired with a conduit interface — just make conduit
runs, mount the unit and make all wire connections.
They are available in NEMA 1 and 4X enclosures that are up to 50%
smaller than other products with comparable ratings. Enhanced
protection status indication is provided by green and red LEDs that
show the true surge protection status on a phase, not the power
status on the phase. This is more reliable and accurate than many
surge protective devices that only have single color indicators that
simply show if power is applied to a phase, not the protection status
on the phase. There are also green and red LED indicators for Wye
units to show the N-G mode surge protection status.
Specifications*
BSPD catalog number system
Description
Ratings
System voltages available (Vac)
Build-a-code catalog numbering system permits specifying any
configuration for an SPD that best meets your requirements.
Three-phase Wye (4 wires plus
ground)
120/208, 277/480, 600
BSPD
Three-phase Delta (3 wires plus
ground)
240, 480, 600
Catalog symbol
BSPD
Input power frequency
SPD type
Short-Circuit Current Rating (SCCR)
50/60Hz
Type 2 (standard and standard with
surge counter configurations)
Nominal discharge current (In)
20kA
Surge current capacity per phase (Imax)
120kA, 200kA, 300kA and 400kA
Protection modes
Three-phase Wye
L-N, L-G, L-L, N-G
Three-phase Delta
L-G, L-L
Conductor length/gauge
48” (1.22m) 10AWG stranded copper
Enclosures
NEMA 1 or NEMA 4X
Operating temperature and humidity
–40°C to 50°C (–40°F to 122°F)
5% to 95% RH, non-condensing
Basic, standard and standard with
surge counter configurations UL
Listed 1449 3rd Edition File E316410
Guide VZCA, CSA® Certified Notice
516 File 243397
Agency information
Warranty
kA rating
per phase
120kA
200kA
300kA
400kA
Type 1 (basic configuration, can also
be used in Type 2 applications)
200kA
Standard and standard with surge
counter configurations are also
UL Recognized 1283 5th Edition
File E316410 Guide VZCA2, CSA
Component Acceptance Std. C22.2
No. 8-M1986 File 243397
•
•
•
Voltage/system type code
208Y=120/208 Wye (4W+G)
480Y=277/480 Wye (4W+G)
600Y=347/600 Wye (4W+G)
240D=240 Delta (3W+G)
480D=480 Delta (3W+G)
600D=600 Delta (3W+G)
K
Enclosure
rating
K=NEMA 1
P=NEMA 4X
Configurations
Basic
•
Cost-effective solution
•
This Type 1 SPD can be installed on the lineside or loadside of
the service entrance panel overcurrent protective device
Standard
•
This Type 2 SPD can be installed
anywhere on the loadside of the service entrance panel overcurrent protective device
•
Audible alarm with silence button
•
EMI/RFI filtering for up to 50dB of noise attenuation from 10kHz
to 100MHz
•
Form C contact relay for easy
integration into a remote monitoring system
Standard with surge counter
•
© 2015 Eaton
All Rights Reserved
Printed in USA
Publication No. 10208
November 2015
2
Three configurations:
*Complete specifications available in data sheet No. 10209.
Bussmann Division
114 Old State Road
Ellisville, MO 63021
United States
Eaton.com/bussmannseries
480D
1=Basic
Green and red LEDs per phase to indicate protection status
Green and red LEDs on Wye units to indicate protection status of the neutral-to-ground
mode
2=Standard
Green and red LEDs per phase to indicate protection status
Green and red LEDs on Wye units to indicate protection status of the neutral-to-ground
mode audible alarm with silence button
3=Standard with surge counter
Green and red LEDs per phase to indicate protection status
Green and red LEDs on Wye units to indicate protection status of the neutral-to-ground
mode audible alarm with silence button
Form C contact relay
EMI/RFI filtering provide up to 50dB of noise attenuation from 10kHz to 100MHz surge
counrter with reset button
10 years (see warranty statement
3A1502 for details at
www.cooperbussmann.com/surge)
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
200
Everything the Standard configuration has, plus a six-digit surge
counter (held in battery-free nonvolatile memory) with reset
button
Eaton, Bussmann, easyID and SurgePOD
are valuable trademarks of Eaton in the US
and other countries. You are not permitted
to use the Eaton trademarks without prior
written consent of Eaton.
CSA is a registered trademark of the
Canadian Standards Group.
NEC is a registered trademark of the
National Fire Protection Association, Inc.
NEMA is a registered trademark of
the National Electrical Manufacturers
Association.
UL is a registered trademark of the
Underwriters Laboratories, Inc.
For Eaton’s Bussmann series
product information,
call 1-855-287-7626 or visit:
Eaton.com/bussmannseries
Follow us on social media to get the
latest product and support information.