3C Corrosion-Resistant Dust-tight Watertight Weatherproof NEMA 3, 4X, 12 NCB Series Circuit Breakers and Enclosures 600VAC, 250VDC Heavy Duty Applications: Certifications and Compliances: 3C • NCB circuit breakers are for use in conjunction with a variety of heating, lighting and power circuits to provide disconnect means and short circuit protection. • NEMA: 3, 4X and 12 • CSA Standard: C22.2 No. 94 • UL Standard: 489 Features: Electrical Rating Ranges: • Enclosures are made of Krydon®, Eaton's Crouse-Hinds' high impact strength fiberglass-reinforced polyester material having excellent corrosion resistance and stability to heat • Unitized, strong and durable enclosure construction provides longer service life for equipment • Enclosure has hinged access door which opens 160° for easy wiring and maintenance. Three screws for door frame are hidden behind access door • Access door may be padlocked to prevent unauthorized access • 100, 150, 225, 250 and 400 amp frames Options: Description Suffix • Insulated, groundable type terminal block for grounded or ungrounded neutral can be supplied • Hubs (see "Note on Hubs") – see listing on page 677 • Grounding plate or bushing – see listing on page 677 S618 Circuit breaker enclosure with built-in Krydon material handle Ordering Information To order an enclosure complete with circuit breaker, insert the manufacturer’s symbol in the designated position of the catalog number. Enclosures only can be ordered. Select from listings. Circuit Breaker Voltage Poles Rating Amps 100A Frame (Non-Interchangeable Trip) 15 20 25 30 35 40 240 VAC/ 2 50 250 VDC 60 70 80 90 100 15 20 25 30 35 40 50 60 70 80 90 100 480 VAC/ 250 VDC 2 Enclosure With Circuit Breaker Cat. # NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F ➀15EB 22 ➀20EB 22 ➀25EB 22 ➀30EB 22 ➀35EB 22 ➀40EB 22 ➀50EB 22 ➀60EB 22 ➀70EB 22 ➀80EB 22 ➀90EB 22 ➀100EB 22 NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F ➀15EHB 24 ➀20EHB 24 ➀25EHB 24 ➀30EHB 24 ➀35EHB 24 ➀40EHB 24 ➀50EHB 24 ➀60EHB 24 ➀70EHB 24 ➀80EHB 24 ➀90EHB 24 ➀100EHB 24 NCB1018F ➀Circuit Breakers: NOTE ON HUBS: The following number and sizes of hubs (not mounted) are included when circuit breakers are ordered complete. If enclosures only are ordered, hubs must be ordered separately (see "Options") Frames 600V 225/ 250A 600V Manufacturer General Electric Symbol 100/ 150A 240V 480V TT TEB TED† TED† TFJ Square D DT FAL† FAL† FAL† KAL WT EB EHB, EHD FB, FDB JB, JDB Cutler-Hammer 400A 600V Circuit Breaker Frame Ampere Rating Number Included Hub Size LAL EB, EHD*, FDB‡ EB, EHD*, FDB‡ JDB■ KDB§ 15–50 60–100 110–225 250–400 2 2 2 2 11/4 2 21/2 3 †Specify voltage. 508 www.crouse-hinds.com Without Circuit Breaker Cat. # US: 1-866-764-5454 CAN: 1-800-265-0502 *Formerly EHB. ‡Formerly FB. §Formerly LB. ■Formerly JB. Copyright© 2013 Eaton’s Crouse-Hinds Business Corrosion-Resistant Dust-tight Watertight Weatherproof NEMA 3, 4X, 12 NCB Series Circuit Breakers and Enclosures 600VAC, 250VDC Heavy Duty Circuit Breaker Voltage Poles Rating Circuit Breaker Enclosure With Circuit Breaker Amps Cat. # Without Circuit Breaker Cat. # 3 3 3 240 VDC 480 VAC 600 VAC 15 20 25 30 35 40 50 70 80 90 100 NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F ➀15EB 32 ➀20EB 32 ➀25EB 32 ➀30EB 32 ➀35EB 32 ➀40EB 32 ➀50EB 32 ➀70EB 32 ➀80EB 32 ➀90EB 32 ➀100EB 32 15 20 25 30 35 40 50 70 80 90 100 NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F ➀15EHB 34 ➀20EHB 34 ➀25EHB 34 ➀30EHB 34 ➀35EHB 34 ➀40EHB 34 ➀50EHB 34 ➀70EHB 34 ➀80EHB 34 ➀90EHB 34 ➀100EHB 34 15 20 25 30 35 40 50 70 80 90 100 NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F NCB1018F ➀15FB 36 ➀20FB 36 ➀25FB 36 ➀30FB 36 ➀35FB 36 ➀40FB 36 ➀50FB 36 ➀70FB 36 ➀80FB 36 ➀90FB 36 ➀100FB 36 NCB1018F Enclosure With Circuit Breaker Amps Cat. # Without Circuit Breaker Cat. # 225/50A Frame (Non-Interchangeable Trip)§ 110 NCB1024F ➀110JB 125 NCB1024F ➀125JB 600 150 NCB1024F ➀150JB VAC/ 2 175 NCB1024F ➀175JB 250 200 NCB1024F ➀200JB VDC 225 NCB1024F ➀225JB 26 26 26 26 26 26 NCB1024F NCB1024F NCB1024F NCB1024F NCB1024F NCB1024F NCB1024F ➀110JB ➀125JB ➀150JB ➀175JB ➀200JB ➀225JB 36 36 36 36 36 36 NCB1024F 400A Frame (Interchangeable Trip)* 250 NCB1426F 300 NCB1426F 600 VAC/ 2 350 NCB1426F 250 VDC 400 NCB1426F ➀250LB ➀300LB ➀350LB ➀400LB 26 26 26 26 NCB1426F ➀250LB ➀300LB ➀350LB ➀400LB 36 36 36 36 NCB1426F 3 3 600 VDC 600 VAC 110 125 150 175 200 225 250 300 350 400 NCB1426F NCB1426F NCB1426F NCB1426F 3C 100/150A Frame (Non-Interchangeable Trip) – continued 15 NCB1018F ➀15FB 26 20 NCB1018F ➀20FB 26 25 NCB1018F ➀25FB 26 30 NCB1018F ➀30FB 26 35 NCB1018F ➀35FB 26 600 VAC/ 40 NCB1018F ➀40FB 26 2‡ NCB1018F 250 VDC 50 NCB1018F ➀50FB 26 70 NCB1018F ➀70FB 26 80 NCB1018F ➀80FB 26 90 NCB1018F ➀90FB 26 100 NCB1018F ➀100FB 26 Voltage Poles Rating 3C ➀Circuit Breakers: NCB1018F Manufacturer General Electric Symbol Frames 100/ 150A 240V 480V TT TEB TED† TED† TFJ Square D DT FAL† FAL† FAL† KAL EB EHB, EHD FB, FDB JB, JDB Cutler-Hammer WT 600V 225/ 250A 600V 400A 600V LAL Note on Hubs: The following number and sizes of hubs (not mounted) are included when circuit breakers are ordered complete. If enclosures only are ordered, hubs must be ordered separately (see "Options"). NCB1018F Circuit Breaker Frame Ampere Rating Number Included Hub Size EB, EHD✪, FDB▲ EB, EHD✪, FDB▲ JDB■ ■Formerly JB ✪Formerly EHB ▲Formerly FB 15–50 60–100 110–225 2 2 2 11/4 2 21/2 †Specify voltage. ‡2-pole, 600 VAC/250 VDC for Square D circuit breakers only. *For Square D circuit breakers only. §Also available with interchangeable trip breakers. Specify on order. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 509 3C Corrosion-Resistant Dust-tight Watertight Weatherproof NEMA 3, 4X, 12 NCB Series Circuit Breakers and Enclosures 600VAC, 250VDC Heavy Duty Dimensions 3C In Inches* Outside Dimensions Cat. # l NCB1018 19 /32 NCB1024 NCB1426 25 /32 2713/32 Mounting Dimensions Door Opening Dimensions d mw ml dl 11 /32 8 /32 7 /8 11 /32 1513/32 8 /32 923/32 7 /8 117/8 w 13 13 13 13 23 23 7 7 19 /8 16 /8 511/16 25 /8 271/4 22 /8 2311/16 511/16 911/16 3 *Dimensions are approximate, not to be used for construction purposes. 510 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 dw 7 3 Copyright© 2013 Eaton’s Crouse-Hinds Business 7