Midwest & Texas utilities CenterPoint Energy, AEP, Xcel Energy, Entergy, Ameren MTRTX-14

Meter mounting equipment
MTRTX-14
Midwest & Texas utilities
CenterPoint Energy, AEP, Xcel Energy, Entergy, Ameren
Eaton and Cooper united.
Energizing a world
that demands more.
Discover today’s Eaton.
Powering business worldwide
As a global power management company, we help
customers worldwide manage the power needed
for buildings, aircraft, trucks, cars, machinery
and businesses.
Eaton’s innovative technologies help customers manage
electrical, hydraulic and mechanical power more reliably,
efficiently, safely and sustainably.
We deliver:
•
•
We provide integrated
Electrical solutions that use less energy, improve power reliability
and make the places we live and work safer and more comfortable
energy, in all its forms,
Hydraulic and electrical solutions that enable machines
accessible.
to deliver more productivity without wasting power
•
Aerospace solutions that make aircraft lighter, safer and less
costly to operate, and help airports operate more efficiently
•
solutions that help make
Vehicle drivetrain and powertrain solutions that deliver
more power to cars, trucks and buses, while reducing fuel consumption
and emissions
more practical and
With 2013 sales of
$22 billion, Eaton
has approximately
100,000 employees
around the world and
sells products in more
than 175 countries.
Eaton’s electrical business
Eaton is a global leader with expertise in:
•
Power distribution and circuit protection
•
Backup power protection
•
Solutions for harsh and hazardous environments
•
Lighting and security
•
Structural solutions and wiring devices
•
Control and automation
•
Engineering services
Eaton is positioned through its global solutions to answer
today’s most critical electrical power management challenges.
With 100 years of electrical experience behind us, we’re
energized by the challenge of powering up a world that
demands twice as much energy as today. We’re anticipating
needs, engineering products and creating solutions to energize
our markets today and in the future.
We are dedicated to ensuring that reliable, efficient and safe
power is available when it’s needed most.
Eaton.com
Introduction
Company History
In 1993, Eaton’s B-Line Business acquired Circle AW. Our legacy includes a strong history of innovation,
including the introduction of the first UL Listed meter socket in 1955, the first Class 320 Listed meter socket
in 1981, and the first overhead to underground meter adapter in 2010.
Today, we are one of the largest manufacturers of quality meter mounting equipment in the United States,
and continue to drive innovation through new product engineering and services.
Within this catalog, you will find the following products to support residential and commercial metering
applications.
• SingleMeterSockets
• MeterMainsandBreakers
• CTRatedMeterSockets,TestSwitches,andCabinets
• Group/GangMeterSockets
• BussGuttersandTerminationCabinets
For more information on meter mounting products, applications, or utility approvals, please refer to our
website:cooperbline.com/metering.
NOTICE
Eaton’s B-Line Business reserves the right to change the specifications, materials, equipment, prices or the
availability of products at any time without prior notice. While every effort has been made to assure the
accuracy of information contained in this catalog at the time of publication, we are not responsible for
inaccuracies resulting from undetected errors or omissions.
UL Recognized Component
Eaton’s B-Line Business
509 West Monroe Street
Highland, Illinois 62249-0326
Phone: 800-851-7415
Fax: 800-257-4312
cooperbline.com/metering
Meter Mounting - Midwest & Texas Utilities
1
Table of Contents
Introduction .................................................................................................................................................................................................................................................... 1
Table of Contents
.....................................................................................................................................................................................................................................
Service Area Coverage Map
........................................................................................................................................................................................................
2
3
CenterPoint Energy - Single Meter Sockets (Ring Type)
125 & 200 Amp .............................................................................................................................................................................................................................. 5 - 6
CenterPoint Energy - Single Meter Sockets (Ringless)
320 Amp ............................................................................................................................................................................................................................................... 7 - 8
AEP - Single Meter Sockets
125 - 320 Amp .............................................................................................................................................................................................................................. 9 - 10
AEP - Meter Mains
100 - 200 Amp ............................................................................................................................................................................................................................ 11 - 12
AEP - Group Meter Sockets (Horn Bypass)
200 Amp Horizontal ............................................................................................................................................................................................................ 13 - 14
AEP - CT Utility Enclosures
................................................................................................................................................................................................................................................................
15 - 16
Xcel Energy / Entergy - Single Meter Sockets
125 & 200 Amp ........................................................................................................................................................................................................................ 17 - 18
Xcel Energy / Entergy - Single Meter Sockets (Lever Bypass)
200 & 320 Amp ........................................................................................................................................................................................................................ 19 - 20
Xcel Energy / Entergy - Meter Mains
125 & 200 Amp ........................................................................................................................................................................................................................ 21 - 22
Xcel Energy / Entergy - Meter Mains (Lever Bypass)
200 & 320 Amp .......................................................................................................................................................................................................................... 23 - 24
Xcel Energy / Entergy - Group Meter Sockets
200 Amp Horizontal ............................................................................................................................................................................................................. 25 - 26
Xcel Energy / Entergy - Group Meter Sockets (Lever Bypass)
200 Amp Horizontal ............................................................................................................................................................................................................ 27 - 28
Ameren - Single Meter Sockets (Lever Bypass)
200 & 320 Amp ........................................................................................................................................................................................................................ 29 - 30
Ameren - Group Meter Sockets (Lever Bypass)
200 Amp Horizontal ............................................................................................................................................................................................................. 31 - 32
Ameren - Group Meter Sockets (Lever Bypass)
200 Amp Vertical.................................................................................................................................................................................................................... 33 - 34
Universal Bussed Gutters
400 - 2000 Amp ......................................................................................................................................................................................................................... 35 - 36
Termination Enclosures
100 - 1200 Amp ......................................................................................................................................................................................................................... 37 - 38
Disconnects - Air Conditioning
................................................................................................................................................................................................................................................................
39 - 40
Accessories
AW Hubs, H-Base Hubs, Supplemental Ground Lug, Lug Kits
Stud/Lug Landing Pad Kits, Cap Set Screw Assemblies ........................................................................................................................ 41
Cap Set Screw Assemblies with Grounding Electrode Connector,
Horned Bypass Cap Assemblies, Jumper Link, Closing Plate,
5th & 7th Jaw Terminal Kits, Touch-Up Paint .................................................................................................................................................... 42
Miscellaneous Data
............................................................................................................................................................................................................................................................................
2
43
Meter Mounting - Midwest & Texas Utilities
Service Area Coverage Map
B
B
B
B
B
B
A
D
A
B
A
E
A
E
A B C E
A
A
D
A
A
E
A - AEP
B - Xcel Energy
C - CenterPoint Energy
D - Ameren
E - Entergy
†
†
†
†
†
† Utilities shown are brand names of their respective owners.
Meter Mounting - Midwest & Texas Utilities
3
Notes
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Texas & Midwest Utilities
4
CenterPoint Energy - Single Meter Sockets (Ring Type)
125 & 200 Amp
Application
•Singlemeterposition
•ReceiveANSIC12.10watthourmeters
•Surfaceorflushmount(seechart)
Construction
•Ringtype
•NEMAType3R
•ANSI61grayE-coatfinish
•Aluminumsnapringincluded
Standards
•UL414Listed
•ANSIC12.7
204-HLP
(open)
Accessories
207-HLP
(open)
•5thJawKit-50365
•200ATriplexGround-ETB200
•AWHub
Part/UPC
Number
Catalog
Number
Amp
Rating
Jaws
Service
Type
Bypass
Access
Utility†
Line
Connections
Load
Neutral
78205126113
78205126114
78205156628
78205126115
78205125629
011-HLP
204-HLP
U204-HLP
207-HLP
U207-HLP
125
200
200
200
200
4
4
4
7
7
1Ø/3W
1Ø/3W
1Ø/3W
3Ø/4W
3Ø/4W
------
OH
OH/UG
UG
OH/UG
UG
CenterPoint
CenterPoint
CenterPoint
CenterPoint
CenterPoint
#14 - 2/0
#6 - 250 MCM
#6 - 250 MCM
#6 - 250 MCM
#6 - 250 MCM
#14 - 2/0
#6 - 250 MCM
#6 - 250 MCM
#6 - 250 MCM
#6 - 250 MCM
#14 - 2/0
#6 - 350 MCM
#6 - 350 MCM
#6 - 250 MCM
#6 - 250 MCM
Part/UPC
Number
Catalog
Number
Height
78205126113
78205126114
78205156628
78205126115
78205125629
011-HLP
204-HLP
U204-HLP
207-HLP
U207-HLP
12”
15”
15”
18”
18”
Overall Dimensions
Width
Depth
8”
12”
12”
12”
12”
4 5/8”
4 5/8”
4 5/8”
5”
5”
Top
Provision
Knockout
Layout
AW Hub
AW Hub
-AW Hub
--
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 4
† Utilities shown are brand names of their respective owners.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
5
Meter Mounting - Midwest & Texas Utilities
CenterPoint Energy - Single Meter Sockets (Ring Type)
125 & 200 Amp
Knockouts - Conduit Sizes
Style #
011
(U) 204
(U) 207
927
Suffixes
1W = 1⁄4”
1A = 1⁄2”
2A = 1⁄2” - 1⁄4”
4F = 2” - 11⁄2” - 11⁄4” - 1”
4G=21⁄2” - 2” - 11⁄2” - 11⁄4”
Top Provision = See Chart
F - Flush Mount
MS68 - 2” Conduit Hub
MS68A - MS73 + MS68
MS73 - AL Screw Type Ring
SS - Stainless Steel
Knockout Layouts
Fig. 1
Fig. 2
Top Provision
Top Provision
4F
4F
4F
4F
both
sides
4F
both
sides
1A
4F
1A
Fig. 4
Fig. 3
Top Provision
Top Provision
4F
4G
4F
4F
4G
4G
4G
both
sides
1W
4G
4G
4G
both
sides
2A
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
6
CenterPoint Energy - Single Meter Sockets (Ringless)
320 Amp
Application
•Singlemeterposition
•ReceiveANSIC12.10watthourmeters
•Surfacemount
Construction
•Ringlesscover
•NEMAType3R
•ANSI61grayE-coatfinish
Standards
•UL414Listed
•ANSIC12.7
Accessories
EL32T76GR1E
(open)
•5thJawKit-50366
•200ATriplexGround-ETB200
•AWHub,HHub
•7thJawKit-50368
EL32T44GRST
(open)
Part/UPC
Number
Catalog
Number
Amp
Rating
Jaws
Service
Type
Bypass
Access
78205140883
78205138485
78205178095
79903860556
78205178094
EL32T44GRST
EL32T46GRST
EL32L53GR1E
EL32T74GR1E
EL32T76GR1E
320
320
320
320
320
4
4
5
7
7
1Ø/3W
1Ø/3W
1Ø/3W or 3Ø/3W
3Ø/4W
3Ø/4W
Lever
Lever
Lever
Lever
Lever
UG (Bussed)
OH/UG (Bussed)
OH/UG
UG (Bussed)
OH/UG (Bussed)
Part/UPC
Number
Catalog
Number
Height
78205140883
78205138485
78205178095
79903860556
78205178094
EL32T44GRST
EL32T46GRST
EL32L53GR1E
EL32T74GR1E
EL32T76GR1E
27 5/8”
36 5/8”
36 1/8”
27 5/8”
39 1/8”
Overall Dimensions
Width
Depth
18 1/4”
18 1/4”
16 1/8”
20 1/4”
20 1/4”
6 1/2”
6 1/2”
6 1/2”
6 1/2”
6 1/2”
Utility†
Line
Connections
Load
Neutral
3
3
3
CenterPoint
/8” Studs
/8” Studs
/8” Studs
3
3
3
/8” Studs
/8” Studs
/8” Studs
CenterPoint
CenterPoint (2) #6 - 250 MCM (2) #6 - 250 MCM (2) #6 - 250 MCM
3
3
3
/8” Studs
/8” Studs
/8” Studs
CenterPoint
3
3
3
/8” Studs
/8” Studs
/8” Studs
CenterPoint
Top
Provision
Knockout
Layout
-H Hub, Cap
H Hub, Cap
-H Hub, Cap
Fig. 1
Fig. 2
Fig. 3
Fig. 1
Fig. 1
† Utilities shown are brand names of their respective owners.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
7
Meter Mounting - Midwest & Texas Utilities
CenterPoint Energy - Single Meter Sockets (Ringless)
320 Amp
Knockouts - Conduit Sizes
1Y = 5⁄16”
2B = 3⁄4” - 1⁄2”
4J=31⁄2” - 3” - 21⁄2” - 2”
4K=4”-31⁄2” - 3” - 21⁄2”
Top Provision = See Chart
Knockout Layouts
Fig. 1
Fig. 2
Fig. 3
Top Provision
Top Provision
Top Provision
4K
4K
both
sides
4K
4K
1Y
4K
both
sides
4J
1Y
2B
2B
1Y
2B
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
4J
both
sides
8
AEP - Single Meter Sockets
125 - 320 Amp
Application
•Singlemeterposition
•ReceiveANSIC12.10watthourmeters
•Surfacemount
Construction
•Ringlesscover
•NEMA Type3R
•ANSI61grayE-coatfinish
Standards
•UL414Listed
•ANSIC12.7
Accessories
EH20L43GR1N
(open)
EH20L73GR1N
(open)
•5thJawKit-50366
•200ATriplexGround-ETB200
•AWHub,HHub
•7thJawKit-50368
Part/UPC
Number
Catalog
Number
Amp
Rating
Jaws
Service
Type
Bypass
Access
Utility†
Line
Connections
Load
79903859775
79903859776
79903859777
79903859778
79903859779
79903859780
78205138484
EH12L41GR1N
EH20L41GR1N
EH20L44GR1N
EL20L73GR1N
EL32T43GR1N
EL32T53GR1N
EL32T75GR1N
125
200
200
200
320
320
320
4
4
4
7
4
5
7
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
3Ø/4W
1Ø/3W
3Ø/4W
Horn
Horn
Horn
Lever
Lever
Lever
Lever
OH
OH
UG (Bussed)
OH/UG
OH/UG
OH/UG
OH/UG
AEP
AEP
AEP
AEP
AEP
AEP
AEP
#14 - 2/0
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
3
/8” Studs
3
/8” Studs
3
/8” Studs
#14 - 2/0
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
3
/8” Studs
3
/8” Studs
3
/8” Studs
Part/UPC
Number
Catalog
Number
Height
79903859775
79903859776
79903859777
79903859778
79903859779
79903859780
78205138484
EH12L41GR1N
EH20L41GR1N
EH20L44GR1N
EL20L73GR1N
EL32T43GR1N
EL32T53GR1N
EL32T75GR1N
12”
15”
15”
21 1/4”
36”
36”
38 1/8”
Overall Dimensions
Width
Depth
8”
8”
13 1/4”
13 1/4”
16”
16”
18 1/4”
4 5/8”
4 5/8”
5”
5”
6 1/2”
6 1/2”
6 1/2”
Top
Provision
Knockout
Layout
AW Hub
AW Hub
-AW Hub, Cap
H Hub, Cap
H Hub, Cap
H Hub, Cap
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 5
Fig. 6
Neutral
#14 - 2/0
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
3
/8” Studs
3
/8” Studs
3
/8” Studs
† Utilities shown are brand names of their respective owners.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
9
Meter Mounting - Midwest & Texas Utilities
AEP - Single Meter Sockets
125 - 320 Amp
Knockouts - Conduit Sizes
1W = 1⁄4”
1Y = 5⁄16”
1Z = 7⁄16”
2A = 1⁄2” - 1⁄4”
2B = 3⁄4” - 1⁄2”
2D = 11⁄4” - 1”
4F = 2” - 11⁄2” - 11⁄4” - 1”
4G=21⁄2” - 2” - 11⁄2” - 11⁄4”
5G=21⁄2” - 2” - 11⁄2” - 11⁄4” - 1”
4H=3”-21⁄2” - 2” - 11⁄2”
4J=31⁄2” - 3” - 21⁄2” - 2”
4K=4”-31⁄2” - 3” - 21⁄2”
Top Provision = See Chart
Knockout Layouts
Fig. 1
Top Provision
Top Provision
1Z
on cover
4F
4F
2A
both
sides
1Z
on cover
4H
4G
4G
Fig. 4
1Z
5G
4H
4F
2D
4F
both
sides
2A
Fig. 5
Top Provision
on cover
1Z
on cover
both
sides
2A
4H
Fig. 3
Fig. 2
Fig. 6
Top Provision
Top Provision
5G
both
sides
4K
1Z
2B
on
cover
1W
4J
4J 1Z
on
4J
cover
4K
both
sides
4K
both
sides
1Y
1Y
2B
2B
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
10
AEP - Meter Mains
100 - 200 Amp
Application
•Singlemeterposition
•ReceiveANSIC12.10watthourmeters
•Surfacemount
Construction
•Ringlesscover
•NEMAType3R
•ANSI61grayE-coatfinish
Standards
•UL414Listed
•ANSIC12.7
Accessories
ENCB20L24A3GR1N
(open)
Part/UPC
Number
Catalog
Number
79903859782
79903859783
79903859784
78205138497
78205162268
78205138500
78205138499
ENCB10L24A3GR1N
ENCB15L24A3GR1N
ENCB20L24A3GR1N
ECCB10L24A3GR1N
ECCB10L27A3GR1N
ELCB20L24A5GR1N
ELCB20L27A5GR1N
Part/UPC
Number
Catalog
Number
79903859782
79903859783
79903859784
78205138497
78205162268
78205138500
78205138499
ENCB10L24A3GR1N
ENCB15L24A3GR1N
ENCB20L24A3GR1N
ECCB10L24A3GR1N
ECCB10L27A3GR1N
ELCB20L24A5GR1N
ELCB20L27A5GR1N
•5thJawKit-50365
•AWHub
ECCB10L27A3GR1N
(open)
Amp
Rating
Jaws
Service
Type
Bypass
Access
Utility†
Voltage
Main Breaker
AIC
Main
100
150
200
100
100
200
200
4
4
4
4
7
4
7
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
3Ø/4W
1Ø/3W
3Ø/4W
---Lever
Lever
Lever
Lever
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
AEP
AEP
AEP
AEP
AEP
AEP
AEP
120/240
120/240
120/240
120/240
120/240
120/240
120/240
10K
10K
10K
10K
10K
10K
10K
(1) 100A, 2P
(1) 150A, 2P
(1) 200A, 2P
(1) 100A, 2P
(1) 100A, 2P
(1) 200A, 2P
(1) 200A, 2P
Line
#14 - 2/0
#6 - 350 MCM
#6 - 350 MCM
#14 - 2/0
#14 - 2/0
#6 - 350 MCM
#6 - 350 MCM
Connections
Load
Neutral
#10 - 2/0
#4 - 4/0
2/0 - 300 MCM
#14 - 1/0
#14 - 1/0
2/0 - 300 MCM
2/0 - 300 MCM
#14 - 2/0
#6 - 350 MCM
#6 - 350 MCM
#14 - 2/0
#14 - 2/0, #10 - 1/0
#6 - 350 MCM
#6 - 350 MCM
Overall Dimensions
Height
Width Depth
29 1/8”
34 1/8”
34 1/8”
19 1/2”
19 1/2”
34 1/8”
34 1/8”
13”
13”
13”
13”
13”
16 1/4”
19 1/4”
5“
5“
5“
5“
5“
5“
5“
Top
Provision
Knockout
Layout
AW Hub, Cap
AW Hub, Cap
AW Hub, Cap
AW Hub, Cap
AW Hub, Cap
H Hub, AW Cap
H Hub, AW Cap
Fig. 1
Fig. 2
Fig. 2
Fig. 3
Fig. 3
Fig. 4
Fig. 4
† Utilities shown are brand names of their respective owners.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
11
Meter Mounting - Midwest & Texas Utilities
AEP - Meter Mains
Main Breaker Data
100 - 200 Amp
Catalog
Number
B-Line
Breaker #
Eaton
Breaker #
Amps
Voltage
Poles
AIC
ENCB10L25A3GR1N
ENCB15L25A3GR1N
ENCB20L25A3GR1N
CBLA047458
CBLC019307
CBLC019301
BR2100
CC2150X
CCV2200X
100
150
200
240
240
240
2P
2P
2P
10K
10K
10K
ECCB10L25A3GR1N
CBLA047458
BR2100
100
240
2P
10K
ECCB10L27A3GR1N
CBLA047954
BR3100
100
240
3P
10K
ELCB20L25A3GR1N
CBLC019301
CCV2200X
200
240
2P
10K
ELCB20L27A3GR1N
CBLC019306
CC3200X
200
240
3P
10K
Knockout Layouts
Fig. 1
Knockouts - Conduit Sizes
Fig. 2
Top Provision
Top Provision
1W = 1⁄4”
1Z = 7⁄16”
2B = 3⁄4” - 1⁄2”
4G=21⁄2” - 2” - 11⁄2” - 11⁄4”
5G=21⁄2” - 2” - 11⁄2” - 11⁄4” - 1”
4H=3”-21⁄2” - 2” - 11⁄2”
Top Provision = See Chart
1Z
1Z
on
cover
on
cover
5G
4H
5G
5G
both
sides
4H
1W
4H
5G
both
sides
4H
2B
1W
2B
Fig. 3
Fig. 4
Top Provision
Top Provision
1Z
on
cover
1Z
on
cover
4H
5G
4G
both
sides
1W
2B
2B
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
12
5G
both
sides
5G
5G
1W
AEP - Group Meter Sockets (Horn Bypass)
200 Amp Horizontal
Application
•Formulti-meterinstallations-6positionmaximum
•400Aand600Amainbuss
•ReceiveANSIC12.10watthourmeters
•Overhead&undergroundfeed(seechart)
•Surfacemount
Construction
•Ringlesscover
•NEMAType3R
•ANSI61grayE-coatfinish
•16ga. galvanized/galvannealedsteel
HEH20432CGR1N
(closed)
HEH20432CGR1N
(open)
Standards
•UL414Listed
•ANSIC12.7
Accessories
•AWHubassemblies
•5thJawKits-50365
•Hornbypasslugcaps
Part/UPC
Number
Catalog
Number
# of
Positions
79903859787
79903859788
79903859789
79903859790
79903859791
HEH20432CGR1N
HEH20433CGR1N
HEH20434CGR1N
HEH20435CGR1N
HEH20436CGR1N
2
3
4
5
6
Buss
Amps
400
400
400
600
600
Part/UPC
Number
Catalog
Number
Height
79903859787
79903859788
79903859789
79903859790
79903859791
HEH20432CGR1N
HEH20433CGR1N
HEH20434CGR1N
HEH20435CGR1N
HEH20436CGR1N
18 1/8”
18 1/8”
18 1/8”
18 1/8”
18 1/8”
Amp
Rating
Jaws
Service
Type
Bypass
Access
Utility†
200
200
200
200
200
4
4
4
4
4
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
Horn
Horn
Horn
Horn
Horn
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
AEP
AEP
AEP
AEP
AEP
Overall Dimensions
Width
Depth
20 1/2”
28 3/4”
37”
45 1/4”
53 1/2”
4 5/8”
4 5/8”
4 5/8”
4 5/8”
4 5/8”
Top
Provision
Knockout
Layout
AW Hub, Cap
AW Hub, Cap
AW Hub, Cap
AW Hub, Cap
AW Hub, Cap
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Line
Connections
Load
/8” Studs
/8” Studs
3
/8” Studs
3
/8” Studs
3
/8” Studs
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
3
3
Neutral
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
† Utilities shown are brand names of their respective owners.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
13
Meter Mounting - Midwest & Texas Utilities
AEP - Group Meter Sockets (Horn Bypass)
200 Amp Horizontal
Fig. 2
Fig. 1
Top Provision
1Z
1Z
on
cover
4H
5G
5G
1W
1W = 1⁄4”
1Z = 7⁄16”
3C = 1” - 3⁄4” - 1⁄2”
5G=21⁄2” - 2” - 11⁄2” - 11⁄4” - 1”
4H=3”-21⁄2” - 2” - 11⁄2”
Top Provision = See Chart
Top Provision
4H
on cover
Knockouts - Conduit Sizes
1W
3C
Knockout Layouts
3C
Fig. 3
Fig. 4
Top Provision
Top Provision
1Z
1Z
on
cover
on
cover
4H
1W
4H
5G
1W
3C
3C
Fig. 5
Top Provision
1Z
on
cover
4H
1W
5G
3C
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
14
5G
AEP - CT Utility Enclosures
Application
•Designedtohousecurrenttransformers(CT)
•Usedaswiringboxes,junctionandpullboxes
•Protectsagainstfallingrain,sleet,andexternal
ice formation
•Surfacemount
Construction
484812 WB DDHRTCT
(open)
484812 WB DDHRTCT
(closed)
•NEMAType3R
•Mountingprovisionsinstalled
•Doorshaveaquick-releasepadlockhaspwith
installed door stop mechanism
•Master/Slavestyleoverlappingdoors
•Plywoodbackpanelinstalled
Standards
•UL414Listed
Finish
•ANSI61graypowdercoated
Part/UPC
Number
Catalog
Number
79903857536 363612 WB DDHRTCT
78205168670 484812 WB DDHRTCT
79903857537 606015 WB DDHRTCT
Cover
Double Door
Double Door
Double Door
Overall Dimensions
Height
Width
Depth
Utility†
AEP
AEP
AEP
36”
48”
60”
36”
48”
60”
12”
12”
15”
Knockout
Layout
Fig. 1
Fig. 1
Fig. 1
† Utilities shown are brand names of their respective owners.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
15
Meter Mounting - Midwest & Texas Utilities
AEP - CT Utility Enclosures
Style #
XXXXXX RTCT
Suffixes
AL - Aluminum
SS - Stainless Steel
Layouts
Fig. 1
Stud & Wingnut Seal
(2 Places)
Padlockable Hasp
Height
Plywood Back
Lift-Off Hinge
Ground Lug
Mounting Hole
Width
Depth
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
16
Xcel Energy / Entergy - Single Meter Sockets
125 & 200 Amp
Application
•Singlemeterposition
•ReceiveANSIC12.10watthourmeters
•Surfacemount
Construction
•Ringlesscover
•NEMAType3R
•ANSI61grayE-coatfinish
Standards
•UL414Listed
•ANSIC12.7
Part/UPC
Number
Catalog
Number
Accessories
EN12L43GR1F
(closed)
EN12L43GR1F
(open)
•5thJawKit-50365
•200ATriplexGround-ETB200
•AWHub
Amp
Rating
Jaws
Service
Type
Access
Utility†
Line
125
125
125
200
200
200
5
5
5
5
5
5
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
OH
UG
OH/UG
OH
UG
OH/UG
Xcel/Entergy
Xcel/Entergy
Xcel/Entergy
Xcel/Entergy
Xcel/Entergy
Xcel/Entergy
#14 - 2/0
#14 - 2/0
#14 - 2/0
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
79903855133
79903855134
79903855135
79903855148
79903855149
79903855150
EN12L51GR1F
EN12L52GR1F
EN12L53GR1F
EN20L51GR1F
EN20L52GR1F
EN20L53GR1F
Part/UPC
Number
Catalog
Number
Height
79903855133
79903855134
79903855135
79903855148
79903855149
79903855150
EN12L51GR1F
EN12L52GR1F
EN12L53GR1F
EN20L51GR1F
EN20L52GR1F
EN20L53GR1F
12”
12”
12”
15”
15”
15”
Overall Dimensions
Width
Depth
8”
12”
12”
8”
12”
12”
4 5/8”
4 5/8”
4 5/8”
4 5/8”
4 5/8”
4 5/8”
Connections
Top
Provision
Knockout
Layout
AW Hub
-AW Hub, Cap
AW Hub
-AW Hub, Cap
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 5
Load
#14 - 2/0
#14 - 2/0
#14 - 2/0
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
† Utilities shown are brand names of their respective owners.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
17
Meter Mounting - Midwest & Texas Utilities
Xcel Energy / Entergy - Single Meter Sockets
125 & 200 Amp
Knockouts - Conduit Sizes
2A = 1⁄2” - 1⁄4”
4F = 2” - 11⁄2” - 11⁄4” - 1”
4G=21⁄2” - 2” - 11⁄2” - 11⁄4”
4H=3”-21⁄2” - 2” - 11⁄2”
Top Provision = See Chart
Knockout Layouts
Fig. 1
Fig. 2
Fig. 3
Top Provision
4F
2A
Top Provision
4F
4H
4F
both
sides
4F
4F
4F
both
sides
4H
4G
2A
2A
Fig. 4
Fig. 5
Top Provision
Top Provision
4G
4G
4G
both
sides
4F
both
sides
4G
both
sides
2A
4F
2A
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
18
Xcel Energy / Entergy - Single Meter Sockets (Lever Bypass)
200 & 320 Amp
Application
• Singlemeterposition
• ReceiveANSIC12.10watthourmeters
• Surfacemount
Construction
• Ringlesscover
• NEMAType3R
• ANSI61grayE-coatfinish
Standards
• UL414Listed
• ANSIC12.7
EL20L71GRST
(open)
Accessories
• 5thJawKit-50365
• AWHub
• 200ATriplexGround-ETB200
• 7thJawKit-50368
EL32T76GR1F
(open)
Part/UPC
Number
Catalog
Number
Amp
Rating
Jaws
Service
Type
Bypass
Access
Utility†
Line
Connections
Load
Neutral
78205132605
78205138487
78205138488
79903860555
79903859792
79903859793
79903859794
79903859795
EL20L53GRST
EL20L71GRST
EL20L73GRST
EL20L76GRST
EL32T53GR1X
EL32T56GR1X
EL32T75GR1X
EL32T76GRX
200
200
200
200
320
320
320
320
5
7
7
7
5
5
7
7
1Ø/3W
3Ø/4W
3Ø/4W
3Ø/4W
1Ø/3W
1Ø/3W
3Ø/4W
3Ø/4W
Lever
Lever
Lever
Lever
Lever
Lever
Lever
Lever
OH/UG
OH
OH/UG
OH/UG (Bussed)
OH/UG
OH/UG (Bussed)
OH/UG
OH/UG (Bussed)
Xcel/Entergy
Xcel/Entergy
Xcel/Entergy
Xcel/Entergy
Xcel/Entergy
Xcel/Entergy
Xcel/Entergy
Xcel/Entergy
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
3
/8” Studs
3
/8” Studs
3
/8” Studs
3
/8” Studs
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
3
/8” Studs
3
/8” Studs
3
/8” Studs
3
/8” Studs
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
3
/8” Studs
3
/8” Studs
3
/8” Studs
3
/8” Studs
Top
Provision
Knockout
Layout
AW Hub, Cap
AW Hub
AW Hub, Cap
H Hub, Cap
H Hub, Cap
H Hub, Cap
H Hub, Cap
H Hub, Cap
Fig. 1
Fig. 2
Fig. 1
Fig. 6
Fig. 3
Fig. 4
Fig. 5
Fig. 4
Part/UPC
Number
Catalog
Number
Height
78205132605
78205138487
78205138488
79903860555
79903859792
79903859793
79903859794
79903859795
EL20L53GRST
EL20L71GRST
EL20L73GRST
EL20L76GRST
EL32T53GR1X
EL32T56GR1X
EL32T75GR1X
EL32T76GR1X
19 1/8”
21 1/4”
21 1/4”
19 1/2”
38 1/8”
36 5/8”
38 1/8”
39 1/8”
Overall Dimensions
Width
Depth
13 1/4”
10 1/4”
13 1/4”
18 1/8”
18 1/4”
18 1/4”
18 1/4”
20 1/4”
5”
5”
5”
6 1/2”
6 1/2”
6 1/2”
6 1/2”
6 1/2”
† Utilities shown are brand names of their respective owners.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
19
Meter Mounting - Midwest & Texas Utilities
Xcel Energy / Entergy - Single Meter Sockets (Lever Bypass)
200 & 320 Amp
Knockouts - Conduit Sizes
1V = 1⁄4” hole
1W = 1⁄4”
1Y = 5⁄16”
1Z = 7⁄16”
2A = 1⁄2” - 1⁄4”
2B = 3⁄4” - 1⁄2”
5G=21⁄2” - 2” - 11⁄2” - 11⁄4” - 1”
4H=3”-21⁄2” - 2” - 11⁄2”
4J=31⁄2” - 3” - 21⁄2” - 2”
4K=4”-31⁄2” - 3” - 21⁄2”
Top Provision = See Chart
Fig. 3
Top Provision
Knockout Layouts
Fig. 1
Fig. 2
Top Provision
5G
4H
Top Provision
4J
5G
4H
both
sides
5G
2B
2B
1W
4J
both
sides
5G
both
sides
1Y
2B
1V
Fig. 4
Fig. 5
Top Provision
Fig. 6
Top Provision
Top Provision
1Z
on
cover
4K
4K
4K
4K
4K
both
sides
2B
4K
both
sides
1Y
1Y
2B
1Y
2A
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
20
4K
both
sides
Xcel Energy / Entergy - Meter Mains
125 & 200 Amp
Application
• Singlemeterposition
• ReceiveANSIC12.10watthourmeters
• Surfacemount
Construction
• Ringlesscover
• NEMAType3R
• ANSI61grayE-coatfinish
Standards
• UL414Listed
• ANSIC12.7
ENCB20L24A3GR1F
(open)
Accessories
ENCB20L24A3GR1F
(closed)
• 5thJawKit-50365
• AWHub
Part/UPC
Number
Catalog
Number
Amp
Rating
Jaws
Service
Type
Access
Utility†
Voltage
Main Breaker
AIC
Main
79903855171
ENCB10L25A3GR1F
125
5
1Ø/3W
OH/UG
Xcel/Entergy
120/240
10K
(1) 100A, 2P
--
78205159267
EN4C10L25A3GRST
125
5
1Ø/3W
OH/UG
Xcel/Entergy
120/240
10K
(1) 100A, 2P
(2) 1P
79903855172
ENCB15L25A3GR1F
200
5
1Ø/3W
OH/UG
Xcel/Entergy
120/240
10K
(1) 150A, 2P
--
79903855173
ENCB20L25A3GR1F
200
5
1Ø/3W
OH/UG
Xcel/Entergy
120/240
10K
(1) 200A, 2P
--
Part/UPC
Number
Catalog
Number
79903855171
ENCB10L25A3GR1F
78205159267
79903855172
79903855173
EN4C10L25A3GRST
ENCB15L25A3GR1F
ENCB20L25A3GR1F
Line
Connections
Load
Neutral
Height
#14 - 2/0
#10 - 2/0
#14 - 2/0
29 1/8”
13”
#14 - 2/0
#6 - 350 MCM
#6 - 350 MCM
29 /8”
34 1/8”
34 1/8”
13”
13”
13”
#14 - 2/0
#10 - 2/0
#6 - 350 MCM
#4 - 4/0
#6 - 350 MCM 2/0 - 300 MCM
1
Overall Dimensions
Width
Depth
Provision
Top
Provision
Knockout
Layout
5”
AW Hub, Cap
Fig. 1
5”
5”
5”
AW Hub, Cap
AW Hub, Cap
AW Hub, Cap
Fig. 1
Fig. 2
Fig. 2
† Utilities shown are brand names of their respective owners.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
21
Meter Mounting - Midwest & Texas Utilities
Xcel Energy / Entergy - Meter Mains
125 & 200 Amp
Knockouts - Conduit Sizes
Main Breaker Data
Catalog
Number
B-Line
Breaker #
Eaton
Breaker #
Amps
Voltage
Poles
AIC
ENCB10L25A3GR1F
CBLA047458
BR2100
100
240
2P
10K
EN4C10L25A3GRST
ENCB20L25A3GR1F
CBLA047458
CBLC019301
BR2100
CCV2200X
100
200
240
240
2P
2P
10K
10K
ENCB15L25A3GR1F
CBLC019307
CC2150X
150
240
2P
10K
1W = 1⁄4”
2B = 3⁄4” - 1⁄2”
5G=21⁄2” - 2” - 11⁄2” - 11⁄4” - 1”
4H=3”-21⁄2” - 2” - 11⁄2”
Top Provision = See Chart
Knockout Layouts
Fig. 1
Fig. 2
Top Provision
Top Provision
5G
4H
4H
5G
5G
both
sides
1W
4H
2B
4H
5G
both
sides
1W
2B
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
22
Xcel Energy / Entergy - Meter Mains (Lever Bypass)
200 & 320 Amp
Application
• Singlemeterposition
• ReceiveANSIC12.10watthourmeters
• Surfacemount
Construction
• Ringlesscover
• NEMAType3R
• ANSI61grayE-coatfinish
Standards
• UL414Listed
• ANSIC12.7
Accessories
• 5thJawKit-50366
• 7thJawKit-50368
• AWHub
ELCB32C25A4GRST
(open)
ELCB20L27A3GR1F
(open)
Part/UPC
Number
Catalog
Number
Amp
Rating
Jaws
Service
Type
Bypass
Access
Utility†
Voltage
Main Breaker
AIC
Main
79903855176
79903855177
79903859796
79903859797
ELCB20L25A3GR1F
ELCB20L27A3GR1F
ELCB32C25A4GR1X
ELCB32C25A5GR1X
200
200
320
320
5
7
5
5
1Ø/3W
3Ø/4W
1Ø/3W
1Ø/3W
Lever
Lever
Lever
Lever
OH/UG
OH/UG
UG (Bussed)
OH/UG
Xcel/Entergy
Xcel/Entergy
Xcel/Entergy
Xcel/Entergy
120/240
120/240
120/240
120/240
10K
10K
10K
10K
(1) 200A, 2P
(1) 200A, 3P
(2) 200A, 2P
(2) 200A, 2P
Part/UPC
Number
Catalog
Number
Connections
Load
Neutral
2/0 - 300 MCM
2/0 - 300 MCM
2/0 - 300 MCM
2/0 - 300 MCM
#6 - 350 MCM
#6 - 350 MCM
3
/8” Studs
3
/8” Studs
Line
79903855176 ELCB20L25A3GR1F #6 - 350 MCM
79903855177 ELCB20L27A3GR1F #6 - 350 MCM
3
/8” Studs
79903859796 ELCB32C25A4GR1X
3
/8” Studs
79903859797 ELCB32C25A5GR1X
Overall Dimensions
Height
Width
Depth
34 1/8”
34 1/8”
30 1/8”
30 1/8”
13”
13”
25 1/4”
25 1/4”
5”
5”
6 1/4”
6 1/4”
Top
Provision
Knockout
Layout
AW Hub, Cap
AW Hub, Cap
-H Hub, AW Adapter
Fig. 1
Fig. 1
Fig. 2
Fig. 3
† Utilities shown are brand names of their respective owners.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
23
Meter Mounting - Midwest & Texas Utilities
Xcel Energy / Entergy - Meter Mains (Lever Bypass)
200 & 320 Amp
Knockouts - Conduit Sizes
Main Breaker Data
Catalog
Number
B-Line
Breaker #
Eaton
Breaker #
Amps
Voltage
Poles
AIC
ELCB20L25A3GR1F
ELCB20L27A3GR1F
ELCB32C25A4GRST
ELCB32C24A5GR1F
CBLC019301
CBLC019306
CBLA047485
CBLA047485
CCV2200X
CC3200X
CCV2200
CCV2200
200
200
200
200
240
240
240
240
2P
3P
2P
2P
10K
10K
10K
10K
1Y = 5⁄16”
1Z = 7⁄16”
2A = 1⁄2” - 1⁄4”
2B = 3⁄4” - 1⁄2”
5G=21⁄2” - 2” - 11⁄2” - 11⁄4” - 1”
4H=3”-21⁄2” - 2” - 11⁄2”
4K=4” - 31⁄2” - 3” - 21⁄2”
Top Provision = See Chart
Knockout Layouts
Fig. 1
Fig. 2
Top Provision
4H
4K
4H
5G
both
sides
1Y
2A
2B
Fig. 3
Top Provision
1Z
on
cover
4H
4K
1Y
2A
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
24
Xcel Energy / Entergy - Group Meter Sockets
200 Amp Horizontal
Application
•Formulti-meterinstallations-6positionmaximum
•400Aand600Amainbuss
•ReceiveANSIC12.10watthourmeters
•Overhead&undergroundfeed(seechart)
•Surfacemount
Construction
•Ringlesscover
•NEMAType3R
•ANSI61grayE-coatfinish
•16ga. galvanized/galvannealedsteel
HEH20432CGRST
(closed)
HEH20432CGRST
(open)
Standards
•UL414Listed
•ANSIC12.7
Accessories
•AWHubassemblies
•5thJawKits-50365
•Hornbypasslugcaps
Part/UPC
Number
Catalog
Number
# of
Positions
Buss
Amps
Amp
Rating
Jaws
Service
Type
Access
Utility†
79903859798
79903859799
79903859800
79903859801
79903859802
HEN20532CGRST
HEN20533CGRST
HEN20534CGRST
HEN20535CGRST
HEN20536CGRST
2
3
4
5
6
400
400
400
600
600
200
200
200
200
200
5
5
5
5
5
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
Xcel/Entergy
Xcel/Entergy
Xcel/Entergy
Xcel/Entergy
Xcel/Entergy
Part/UPC
Number
Catalog
Number
Height
79903859798
79903859799
79903859800
79903859801
79903859802
HEN20532CGRST
HEN20533CGRST
HEN20534CGRST
HEN20535CGRST
HEN20536CGRST
18 1/8”
18 1/8”
18 1/8”
18 1/8”
18 1/8”
Overall Dimensions
Width
Depth
20 1/2”
28 3/4”
37”
45 1/4”
53 1/2”
4 5/8”
4 5/8”
4 5/8”
4 5/8”
4 5/8”
Top
Provision
Knockout
Layout
AW Hub, Cap
AW Hub, Cap
AW Hub, Cap
AW Hub, Cap
AW Hub, Cap
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Line
Connections
Load
Neutral
/8” Studs
/8” Studs
3
/8” Studs
3
/8” Studs
3
/8” Studs
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
3
3
† Utilities shown are brand names of their respective owners.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
25
Meter Mounting - Midwest & Texas Utilities
Xcel Energy / Entergy - Group Meter Sockets
200 Amp Horizontal
Fig. 2
Fig. 1
Top Provision
4H
5G
5G
1W
1W = 1⁄4”
3C = 1” - 3⁄4” - 1⁄2”
5G=21⁄2” - 2” - 11⁄2” - 11⁄4” - 1”
4H=3”-21⁄2” - 2” - 11⁄2”
Top Provision = See Chart
Top Provision
4H
1W
3C
Knockouts - Conduit Sizes
Knockout Layouts
3C
Fig. 3
Fig. 4
Top Provision
4H
4H
1W
Top Provision
5G
1W
3C
3C
Fig. 5
Top Provision
4H
1W
5G
3C
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
26
5G
Xcel Energy / Entergy - Group Meter Sockets (Lever Bypass)
200 Amp Horizontal
Application
•Formulti-meterinstallations-6positionmaximum
•400Aand600Amainbuss
•ReceiveANSIC12.10watthourmeters
•Overhead&undergroundfeed(seechart)
•Surfacemount
Construction
•Ringlesscover
•NEMAType3R
•ANSI61grayE-coatfinish
•16ga.galvanized/galvannealedsteel
•6o’clock/9o’clockpositionable5thjaw
HEL20434CGR1F
(open)
Standards
•UL414Listed
•ANSIC12.7
Accessories
•AW&Hhubassemblies
•5thjawkits-50366
HEL20434CGR1F
(closed)
Part/UPC
Number
Catalog
Number
# of
Positions
Buss
Amps
Amp
Rating
Jaws
Service
Type
Bypass
Access
Utility†
79902855234
HEL20432CGR1F
2
400
200
5
1Ø/3W
Lever
OH/UG
Xcel/Entergy
79902855235
HEL20433CGR1F
3
400
200
5
1Ø/3W
Lever
OH/UG
Xcel/Entergy
79902855236
HEL20434CGR1F
4
400
200
5
1Ø/3W
Lever
OH/UG
Xcel/Entergy
79902855237
HEL20435CGR1F
5
600
200
5
1Ø/3W
Lever
OH/UG
Xcel/Entergy
79902855239
HEL20436CGR1F
6
600
200
5
1Ø/3W
Lever
OH/UG
Xcel/Entergy
79902855222
HEL20732CGR1F
2
400
200
7
3Ø/4W
Lever
OH/UG
Xcel/Entergy
79902855223
HEL20733CGR1F
3
400
200
7
3Ø/4W
Lever
OH/UG
Xcel/Entergy
79902855224
HEL20734CGR1F
4
400
200
7
3Ø/4W
Lever
OH/UG
Xcel/Entergy
79902855225
HEL20735CGR1F
5
600
200
7
3Ø/4W
Lever
OH/UG
Xcel/Entergy
79902855226
HEL20736CGR1F
6
600
200
7
3Ø/4W
Lever
OH/UG
Xcel/Entergy
Part/UPC
Number
Catalog
Number
79902855234
79902855235
79902855236
79902855237
79902855239
79902855222
79902855222
79902855223
79902855225
79902855226
HEL20432CGR1F
HEL20433CGR1F
HEL20434CGR1F
HEL20435CGR1F
HEL20436CGR1F
HEL20732CGR1F
HEL20733CGR1F
HEL20734CGR1F
HEL20735CGR1F
HEL20736CGR1F
Phase & Line Conductors
Line
Load
/8” Studs
/8” Studs
3
/8” Studs
3
/8” Studs
3
/8” Studs
3
/8” Studs
3
/8” Studs
3
/8” Studs
3
/8” Studs
3
/8” Studs
3
3
Overall Dimensions
Height
Width
Depth
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
25”
25”
25”
25”
25”
25”
25”
25”
25”
25”
30 3/4”
41”
511/4”
611/2”
713/4”
30 3/4”
41”
511/4”
611/2”
713/4”
6”
6”
6”
6”
6”
6”
6”
6”
6”
6”
Top
Provision
Knockout
Layout
(2) H Hub, Cap
(2) H Hub, Cap
(2) H Hub, Cap
(2) H Hub, Cap
(2) H Hub, Cap
(2) H Hub, Cap
(2) H Hub, Cap
(2) H Hub, Cap
(2) H Hub, Cap
(2) H Hub, Cap
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
† Utilities shown are brand names of their respective owners.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
27
Meter Mounting - Midwest & Texas Utilities
Xcel Energy / Entergy - Group Meter Sockets (Lever Bypass)
200 Amp Horizontal
Knockouts - Conduit Sizes
1W = 1⁄4” dia.
2B = 3⁄4” - 1⁄2”
4K=4”-31⁄2” - 3” - 21⁄2”
5G=21⁄2” - 2” - 11⁄2” - 11⁄4” - 1”
Top Provision = See Chart
Knockout Layouts
Fig. 1
Top
Provision
Top Provision
Fig. 2
Top
Provision
Top Provision
5G
5G
5G
1W 2B
both
sides
4K
5G
4K
both
sides
5G
5G
5G
Fig. 3
Top
Provision
5G
5G
1W 2B
Top
Provision
1W 2B
4K
Fig. 4
Top Provision
5G
5G
1W 2B
Top Provision
4K
5G
5G
5G
both
sides
both
sides
Top Provision
Top Provision
5G
1W 2B
4K
Fig. 5
5G
5G
both
sides
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
28
Ameren - Single Meter Sockets (Lever Bypass)
200 & 320 Amp
Application
•Singlemeterposition
•ReceiveANSIC12.10watthourmeters
•Surfacemount
Construction
•Ringlesscover
•NEMAType3R
•ANSI61grayE-coatfinish
Standards
•UL414Listed
•ANSIC12.7
ELCB32C25A4GRST
(open)
EL20L71GRST
(open)
Part/UPC
Number
Catalog
Number
Amp
Rating
Jaws
Service
Type
Bypass
78205132605
78205138488
78205138486
79903860558
EL20L53GRST
EL20L73GRST
EL32T76GRST
ELCB32C25A4GRST
200
200
320
320
5
7
7
5
1Ø/3W
3Ø/4W
3Ø/4W
1Ø/3W
Lever
Lever
Lever
Lever
Part/UPC
Number
Catalog
Number
78205132605
EL20L53GRST
#6 - 350 MCM
78205138488
EL20L73GRST
#6 - 350 MCM
3
/8” Studs
78205138486
EL32T76GRST
3
/8” Studs
79903860558 ELCB32C25A4GRST
•5thJawKit-50366
•7thJawKit-50368
•AWHub
Utility†
Voltage
Main Breaker
AIC
Main
OH/UG
Ameren
OH/UG
Ameren
OH/UG (Bussed) Ameren
UG (Bussed)
Ameren
---120/240
---10K
---(2) 200A
Access
Connections
Load
Neutral
#6 - 350 MCM
#6 - 350 MCM
3
/8” Studs
2/0 - 300 MCM
#6 - 350 MCM
#6 - 350 MCM
3
/8” Studs
#6 - 350 MCM
Line
Accessories
Overall Dimensions
Height
Width
Depth
19 1/8”
211/4”
39 1/8”
28 1/2”
13 1/4”
13 1/4”
20 1/4”
25 1/2”
5”
5”
6 1/2”
6 1/2”
Top
Provision
Knockout
Layout
AW Hub, Cap
AW Hub, Cap
H Hub, Cap
--
Fig. 1
Fig. 1
Fig. 2
Fig. 3
† Utilities shown are brand names of their respective owners.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
29
Meter Mounting - Midwest & Texas Utilities
Ameren - Single Meter Sockets (Lever Bypass)
200 & 320 Amp
Knockouts - Conduit Sizes
1W = 1⁄4”
1Y = 5⁄16”
2A = 1⁄2” - 1⁄4”
2B = 3⁄4” - 1⁄2”
5G=21⁄2” - 2” - 11⁄2” - 11⁄4” - 1”
4H=3”-21⁄2” - 2” - 11⁄2”
4K=4”-31⁄2” - 3” - 21⁄2”
Top Provision = See Chart
Knockout Layouts
Fig. 1
Fig. 2
Top Provision
5G
4H
2B
Top Provision
5G
4H
both
sides
1W
Fig. 3
4K
4K
Top Provision
both
sides
1Y
2B
4H
4K
1Y
2A
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
30
Ameren - Group Meter Sockets (Lever Bypass)
200 Amp Horizontal
Application
•Formulti-meterinstallations-6positionmaximum
•400Aand600Amainbuss
•ReceiveANSIC12.10watthourmeters
•Overhead&undergroundfeed(seechart)
•Surfacemount
Construction
HEL20434CGR1N (closed)
•Ringlesscover
•NEMAType3R
•ANSI61grayE-coatfinish
•16ga.galvanized/galvannealedsteel
•6o’clock/9o’clockpositionable5thjaw
Standards
•UL414Listed
•ANSIC12.7
Accessories
•AW&Hhubassemblies
•5thjawkits-50366
HEL20434CGR1N (open)
Part/UPC
Number
Catalog
Number
# of
Positions
Buss
Amps
Amp
Rating
Jaws
Service
Type
Bypass
Access
Utility†
79903860559
HEL20532CGR1N
2
400
200
5
1Ø/3W
Lever
OH/UG
Ameren
79903860560
HEL20533CGR1N
3
400
200
5
1Ø/3W
Lever
OH/UG
Ameren
79903860561
HEL20534CGR1N
4
400
200
5
1Ø/3W
Lever
OH/UG
Ameren
78205140301
HEL20732CGR1N
2
400
200
7
3Ø/4W
Lever
OH/UG
Ameren
78205163153
HEL20733CGR1N
3
400
200
7
3Ø/4W
Lever
OH/UG
Ameren
78205163154
HEL20734CGR1N
4
400
200
7
3Ø/4W
Lever
OH/UG
Ameren
Part/UPC
Number
Catalog
Number
79903860559
79903860560
79903860561
78205140301
78205163153
78205163154
HEL20532CGR1N
HEL20533CGR1N
HEL20534CGR1N
HEL20732CGR1N
HEL20733CGR1N
HEL20734CGR1N
Phase & Line Conductors
Line
Load
/8” Studs
/8” Studs
3
/8” Studs
3
/8” Studs
3
/8” Studs
3
/8” Studs
3
3
Overall Dimensions
Height
Width
Depth
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
25”
25”
25”
25”
25”
25”
30 3/4”
41”
511/4”
30 3/4”
41”
511/4”
6”
6”
6”
6”
6”
6”
Top
Provision
Knockout
Layout
(2) H Hub, Cap
(2) H Hub, Cap
(2) H Hub, Cap
(2) H Hub, Cap
(2) H Hub, Cap
(2) H Hub, Cap
Fig. 1
Fig. 2
Fig. 3
Fig. 1
Fig. 2
Fig. 3
† Utilities shown are brand names of their respective owners.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
31
Meter Mounting - Midwest & Texas Utilities
Ameren - Group Meter Sockets (Lever Bypass)
200 Amp Horizontal
Knockouts - Conduit Sizes
1W = 1⁄4” dia.
1Z = 7⁄16”
2B = 3⁄4” - 1⁄2”
4K=4”-31⁄2” - 3” - 21⁄2”
5G=21⁄2” - 2” - 11⁄2” - 11⁄4” - 1”
Top Provision = See Chart
Knockout Layouts
Fig. 1
Top
Provision
Fig. 2
Top
Provision
Top Provision
Top Provision
5G
5G
5G
1W 2B
4K
5G
both
sides
1Z
on
cover
5G
5G
1W 2B
4K
5G
1Z
on
cover
Fig. 3
Top
Provision
5G
5G
1W 2B
Top
Provision
4K
5G
1Z
on
cover
5G
both
sides
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
32
both
sides
Ameren - Group Meter Sockets (Lever Bypass)
200 Amp Vertical
Application
•Formulti-meterinstallations-5positionmaximum
•400Aand640Amainbuss
•ReceiveANSIC12.10watthourmeters
•Overhead&undergroundfeed(seechart)
•Surfacemount
Construction
•Ringlesscover
•NEMAType3R
•ANSI61grayE-coatfinish
•16ga.galvanized/galvannealedsteel
•6o’clock/9o’clockpositionable5thjaw
Standards
VELMP20435CGRST5K9 (closed)
•UL414Listed
•ANSIC12.7
Accessories
•AW&Hhubassemblies
•5thjawkits-50366
Part/UPC
Number
Catalog
Number
# of
Positions
Buss
Amps
Amp
Rating
Jaws
Service
Type
Bypass
Access
Utility†
78205141433
VELMP20432LGRST5K9
2
400
200
5
1Ø/3W
Lever
OH/UG
Ameren
78205141434
VELMP20433LGRST5K9
3
400
200
5
1Ø/3W
Lever
OH/UG
Ameren
78205141435
VELMP20434CGRST5K9
4
640
200
5
1Ø/3W
Lever
OH/UG
Ameren
78205141436
VELMP20435CGRST5K9
5
640
200
5
1Ø/3W
Lever
OH/UG
Ameren
Part/UPC
Number
Catalog
Number
Main Breaker
Provision
Top
Provision
Knockout
Layout
(2) 2P*
(2) H Hub, Cap
Fig. 1
Phase & Line Conductors
Line
Load
78205141433
VELMP20432LGRST5K9
3
Overall Dimensions
Height
Width
Depth
/8” Studs
#6 - 350 MCM
45 1/4”
/8” Studs
/8” Studs
/8” Studs
78205141434
VELMP20433LGRST5K9
3
78205141435
VELMP20434CGRST5K9
3
78205141436
VELMP20435CGRST5K9
3
29”
6”
#6 - 350 MCM
1
60 /4”
29”
6”
(3) 2P*
(2) H Hub, Cap
Fig. 2
#6 - 350 MCM
45”
46 1/2”
6”
(4) 2P*
(2) H Hub, Cap
Fig. 3
#6 - 350 MCM
60 1/4”
46 1/2”
6”
(5) 2P*
(2) H Hub, Cap
Fig. 1
† Utilities shown are brand names of their respective owners.
* Accepts plug in style main breakers.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
33
Meter Mounting - Midwest & Texas Utilities
Ameren - Group Meter Sockets (Lever Bypass)
200 Amp Vertical
Knockouts - Conduit Sizes
Knockout Layouts
1W = 1⁄4” dia.
1Z = 7⁄16”
2A = 1⁄2” - 1⁄4”
4F = 2” - 11⁄2” - 11⁄4” - 1”
4K=4”-31⁄2” - 3” - 21⁄2”
Top Provision = See Chart
Fig. 2
Fig. 1
Top Provision
Top Provision
1Z
1Z
on
cover
on
cover
2A
4K
4K
1W
4F
2A 1W
4F
Fig. 4
Fig. 3
Top Provision
Top Provision
1Z
1Z
on
cover
on
cover
4K
4F
2A
4K
4F
1W
4F
2A
4F
1W
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
34
Universal Bussed Gutters
400 - 2000 Amp
Application
•WithKOsforgangingTB/MTBunits
under a common feed
•Surfacemount
Construction
•NEMAType3R
•ANSI61grayE-coatfinish
•Aluminumbussing
Standards
R1060HEE
(closed)
R1060HEE
(open)
•UL1773Listed
Part/UPC
Number
Catalog
Number
Buss
Amps
Service
Type
AIC
Line
Connections
Load
Neutral
Overall Dimensions
Height
Width
Depth
Knockout
Layout
78205118055
78205118065
78205118075
78205118085
78205118095
78205118115
78205118125
78205118135
78205118145
78205118325
78205118335
78205118345
R1024 HC
R1036 HC
R1048 HC
R1060 HC
R1072 HC
R1036 HD
R1048 HD
R1060 HD
R1072 HD
R1048 HE
R1060 HE
R1072 HE
400
400
400
400
400
600
600
600
600
800
800
800
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
1Ø/3W
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
#4 - 600 MCM
#4 - 600 MCM
#4 - 600 MCM
#4 - 600 MCM
#4 - 600 MCM
(2) #4 - 600 MCM
(2) #4 - 600 MCM
(2) #4 - 600 MCM
(2) #4 - 600 MCM
(3) #4 - 600 MCM
(3) #4 - 600 MCM
(3) #4 - 600 MCM
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
#4 - 600 MCM
#4 - 600 MCM
#4 - 600 MCM
#4 - 600 MCM
#4 - 600 MCM
(2) #4 - 600 MCM
(2) #4 - 600 MCM
(2) #4 - 600 MCM
(2) #4 - 600 MCM
(3) #4 - 600 MCM
(3) #4 - 600 MCM
(3) #4 - 600 MCM
22”
22”
22”
22”
22”
22”
22”
22”
22”
22”
22”
22”
24”
36”
48”
60”
72”
36”
48”
60”
72”
48”
60”
72”
6”
6”
6”
6”
6”
6”
6”
6”
6”
6”
6”
6”
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
78205118215
78205118225
78205118235
78205118245
78205118255
78205108075
78205118275
78205118285
78205118295
78205118305
78205131978
78205118150
78205118375
78205118385
78205118395
78205118401
78205118160
78205131970
78205131972
78205118200
78205118170
78205131974
78205118205
78205118190
78205131976
78205118210
78205118195
R1024 HCC
R1036 HCC
R1048 HCC
R1060 HCC
R1072 HCC
R1096 HCC
R1036 HDD
R1048 HDD
R1060 HDD
R1072 HDD
R1096 HDD
R10120 HDD
R1048 HEE
R1060 HEE
R1072 HEE
R1096 HEE
R10120 HEE
R1060 HFF
R1072 HFF
R1096 HFF
R10120 HFF
R1072 HGG
R1096 HGG
R10120 HGG
R1072 HHH
R1096 HHH
R10120 HHH
400
400
400
400
400
400
600
600
600
600
600
600
800
800
800
800
800
1200
1200
1200
1200
1600
1600
1600
2000
2000
2000
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
3Ø/4W
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
#4 - 600 MCM
#4 - 600 MCM
#4 - 600 MCM
#4 - 600 MCM
#4 - 600 MCM
#4 - 600 MCM
(2) #4 - 600 MCM
(2) #4 - 600 MCM
(2) #4 - 600 MCM
(2) #4 - 600 MCM
(2) #4 - 600 MCM
(2) #4 - 600 MCM
(3) #4 - 600 MCM
(3) #4 - 600 MCM
(3) #4 - 600 MCM
(3) #4 - 600 MCM
(3) #4 - 600 MCM
(4) #4 - 600 MCM
(4) #4 - 600 MCM
(4) #4 - 600 MCM
(4) #4 - 600 MCM
(6) #4 - 600 MCM
(6) #4 - 600 MCM
(6) #4 - 600 MCM
(6) #4 - 600 MCM
(6) #4 - 600 MCM
(6) #4 - 600 MCM
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
See Note *
#4 - 600 MCM
#4 - 600 MCM
#4 - 600 MCM
#4 - 600 MCM
#4 - 600 MCM
#4 - 600 MCM
(2) #4 - 600 MCM
(2) #4 - 600 MCM
(2) #4 - 600 MCM
(2) #4 - 600 MCM
(2) #4 - 600 MCM
(2) #4 - 600 MCM
(3) #4 - 600 MCM
(3) #4 - 600 MCM
(3) #4 - 600 MCM
(3) #4 - 600 MCM
(3) #4 - 600 MCM
(4) #4 - 600 MCM
(4) #4 - 600 MCM
(4) #4 - 600 MCM
(4) #4 - 600 MCM
(6) #4 - 600 MCM
(6) #4 - 600 MCM
(6) #4 - 600 MCM
(6) #4 - 600 MCM
(6) #4 - 600 MCM
(6) #4 - 600 MCM
22”
22”
22”
22”
22”
22”
28 1/2”
28 1/2”
28 1/2”
28 1/2”
28 1/2”
28 1/2”
28 1/2”
28 1/2”
28 1/2”
28 1/2”
28 1/2”
36”
36”
36”
36”
36”
36”
36”
36”
36”
36”
24”
36”
48”
60”
72”
96”
36”
48”
60”
72”
96”
120”
48”
60”
72”
96”
120”
60”
72”
96”
120”
72”
96”
120”
72”
96”
120”
6”
6”
6”
6”
6”
6”
6”
6”
6”
6”
6”
6”
6”
6”
6”
6”
6”
6”
6”
6”
6”
8”
8”
8”
8”
8”
8”
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Note: * 5/16” mounting holes for load lugs - single location per phase per foot of width.
Note: Every 600 MCM lug barrel will accept (2) 1/0 - 250 MCM cables
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
35
Meter Mounting - Midwest & Texas Utilities
Universal Bussed Gutters
400 - 2000 Amp
Style #
R1024
R1036
R1048
R1060
R1072
R1096
R10120
Suffixes
SS - Stainless Steel
/CU - Copper Buss
Layouts
Fig. 1
All cabinets 60” and wider have two (2) doors.
Cabinets 48” wide and 28 1/2” tall also have two (2) doors.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
36
Termination Enclosures
100 - 1200 Amp
Application
•Forterminationofutilitysupplycables
•Usedasaterminationpointbefore
bussedguttersinundergroundapplications
•Surfacemount
Construction
•NEMAType3R
•ANSI61grayE-coatfinish
•Aluminumbussing
•Removabledoorwithsealingprovision
and lifting handles
Standards
•UL1773Listed
R9000EE
(closed)
R9000EE
(open)
Part/UPC
Number
Catalog
Number
Amp
Rating
Service
Type
Access
AIC
Phase & Neutral Connections
Line
Load
Overall Dimensions
Height Width Depth
Knockout
Layout
78205153196
R9007 A
100
1Ø or 3Ø/3W
UG
10K
#14 - 2/0
#14 - 2/0
8”
12”
4”
Fig. 1
78205158183
R9000 B
200
1Ø or 3Ø/3W
UG
10K
#6 - 250 MCM
#6 - 250 MCM
26”
12”
6”
Fig. 1
78205153189
R9000 BB
200
3Ø/4W
UG
10K
#6 - 250 MCM
#6 - 250 MCM
26”
16”
6”
Fig. 1
78205153184
R9000 C
400
1Ø or 3Ø/3W
UG
42K
2 Studs / Ø
#6 - 600 MCM
44”
12”
7”
Fig. 1
78205153190
R9000 CC
400
3Ø/4W
UG
42K
2 Studs / Ø
#6 - 600 MCM
44”
18”
7”
Fig. 1
78205153186
R9000 E
800
1Ø or 3Ø/3W
UG
65K
4 Studs / Ø
(3) #4 - 600 MCM
52”
18”
11”
Fig. 1
78205153192
R9000 EE
800
3Ø/3W
UG
65K
4 Studs / Ø
(3) #4 - 600 MCM
52”
26”
11”
Fig. 1
78205153188
R9000 F
1200
1Ø or 3Ø/3W
UG
65K
6 Studs / Ø
(4) #4 - 600 MCM
52”
24”
11”
Fig. 1
78205153194
R9000 FF
1200
3Ø/4W
UG
65K
6 Studs / Ø
(4) #4 - 600 MCM
52”
36”
11”
Fig. 1
78205107197
R9000 CL
400
1Ø or 3Ø/3W
OH/UG
42K
#4 - 600 MCM
#4 - 600 MCM
44”
12”
7”
Fig. 1
78205107200
R9000 CCL
400
3Ø/4W
OH/UG
42K
#4 - 600 MCM
#4 - 600 MCM
44”
18”
7”
Fig. 1
78205107198
R9000 EL
800
1Ø or 3Ø/3W
OH/UG
65K
(3) #4 - 600 MCM
(3) #4 - 600 MCM
52”
18”
11”
Fig. 1
78205107201
R9000 EEL
800
3Ø/3W
OH/UG
65K
(3) #4 - 600 MCM
(3) #4 - 600 MCM
52”
26”
11”
Fig. 1
78205107199
R9000 FL
1200
1Ø or 3Ø/3W
OH/UG
65K
(4) #4 - 600 MCM
(3) #4 - 600 MCM
52”
24”
11”
Fig. 1
78205107202
R9000 FFL
1200
3Ø/4W
OH/UG
65K
(4) #4 - 600 MCM
(3) #4 - 600 MCM
52”
36”
11”
Fig. 1
Notes:
Every 600 MCM lug barrel will accept (2) 1/0 - 250 MCM cables.
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
37
Meter Mounting - Midwest & Texas Utilities
Termination Enclosures
100 - 1200 Amp
Style #
R9000
Suffixes
SS - Stainless Steel
Layouts
Fig. 1
52” tall cabinets have two (2) overlapping doors as shown on the
R9000EE photo (page 30)
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
38
Disconnects - Air Conditioning
Application
•NEMA® 3R outdoor enclosures offered in metallic and nonmetallic
versions
•Horsepowerrated(10hpmaximumat240Vac)
•Surfaceorflushmount(seechart)
Construction
•Easy-to-removehighstrengthprotectiveshieldforeasierwiring
and mounting
• Easy-to-removefrontcover(noscrewsorfastenerstoremove)
• Amplewiringspaceformountingwithastudgun(simple
keyhole,twoorthree-pointmounting)
• Fuseddevicesareserviceentrancerated
• Padlockabledoorprovisionforsafetyandreductionoftampering
• Metallicenclosuresarebottomentryandexitonly
• Metallicenclosureshaveknockoutsandahubprovisionfortop
access
• Nonmetallicenclosureshaveasingleunitdoorandprotective
shield for installer convenience
• Nonmetallicenclosuresaredurableandprovideexcellent
resistance to climate changes
AC60NOMT0
(shown open & closed)
Standards
•ULlistedfileNo.E5239
•SeparateCSA® approved unit
AC30FPNM0
(shown open & closed)
Part/UPC
Number
Power Specification
•10,000amperesrmssymmetricalinterruptingrating
•Horsepowerrated
•Fusibleandnon-fusiblepulloutandmoldedcaseswitchdesigns
•30and60amperesavailableinfusible
•60amperesavailableinnon-fusibleandmoldedswitchcase
•ClassHfuseclipsprovidedonfusiblepulloutdesign
Catalog
Number
Maximum
HP
AC Disconnect
Wire Range
CU
AL
Neutral
Conductor
CU / AL
Wire Rating
Line
Load
CU °C
AL °C
Overall Dimensions
Height
Width Depth
Figure
Number
AC60NOMT0
AC60NONM0
10
10
#14 - #2
#14 - #2
#12 - #6
#12 - #6
#14 - #4
#14 - #4
60°/75°
60°/75°
60°/75°
60°/75°
8 3/4”
8 11/16”
5 3/8”
6 1/4”
3 1/8”
3 3/8”
Fig. 1
Fig. 2
AC30FPMT0
AC30FPNM0
10
10
#14 - #2
#14 - #2
#12 - #6
#12 - #6
#14 - #4
#14 - #4
60°/75°
60°/75°
60°/75°
60°/75°
8 3/4” 5 3/8”
8 11/16” 6 1/4”
3 1/8”
3 3/8”
Fig. 1
Fig. 2
AC60FPMT0
AC60FPNM0
10
10
#14 - #2
#14 - #2
#12 - #6
#12 - #6
#14 - #4
#14 - #4
60°/75°
60°/75°
60°/75°
60°/75°
8 3/4” 5 3/8”
8 11/16” 6 1/4”
31/8”
3 3/8”
Fig. 1
Fig. 2
#14 - #2
#12 - #6
#14 - #4
60°/75°
60°/75°
4 3/4”
Fig. 3
60 Amp - Nonfusible
78205139801
78205141681
30 Amp - Fused
78205141677
78205141679
60 Amp - Fused
78205141687
78205141680
60 Amp - Nonfusible with GFCI Duplex Receptacle
78205139802
AC60NOMT2
10
13”
7 1/2”
Fused non-metallic units require the addition of GB5NM ground bar
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
39
Meter Mounting - Midwest & Texas Utilities
Disconnects - Air Conditioning
Knockouts - Conduit Sizes
1X = 9⁄32”
2B = 3⁄4” - 1⁄2”
2C = 1” - 3⁄4”
3C = 1” - 3⁄4” - 1⁄2”
3D = 11⁄4” - 1” - 3⁄4”
4E = 11⁄2” - 11⁄4” - 1” - 3⁄4”
Knockout Layouts
Fig. 1
2B
Fig. 2
3D
3C
2B
2C
2B
2B
3C
1X
Fig. 3
4E
3C
2B
2B
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
40
2C
Accessories
AW Hubs
Lug Kits
Part/UPC
Number
Catalog
Number
Description
78205139040
78205139050
AW100
AW125
1” Conduit
11/4” Conduit
78205139060
78205139070
78205139080
78205134721
AW150
AW200
AW250
AWCAP
11/2” Conduit
2” Conduit
2 1/2” Conduit
AW Cap - Gray
AW125
AW200
Part/UPC
Number
Catalog
Number
78205163260
78205163261
78205163262
78205163263
78205139641
78205139642
78205139643
78205139647
78205139648
78205139644
78205139645
78205139649
78205139650
101
103
201
202
212
311
312
331
332
611
612
631
632
Description
1/0 Single Lug Kit, 1 Per Set
1/0 Triple Lug Kit, 1 Per Set
2/0 Single Lug Kit, 1 Per Set
2/0 Dual Lug Kit, 1 Per Set
250 KCMIL Dual Lug Kit, 1Ø, 3 Per Set
350 KCMIL Single Lug Kit, 1Ø, 3 Per Set
350 KCMIL Double Lug Kit, 1Ø, 3 Per Set
350 KCMIL Single Lug Kit, 3Ø, 4 Per Set
350 KCMIL Double Lug Kit, 3Ø, 4 Per Set
600 KCMIL Single Lug Kit, 1Ø, 3 Per Set
600 KCMIL Double Lug Kit, 1Ø, 3 Per Set
600 KCMIL Single Lug Kit, 3Ø, 4 Per Set
600 KCMIL Double Lug Kit, 3Ø, 4 Per Set
202
212
312
332
612
632
101
201
311
331
611
631
AWCAP
H-Base Hubs
Part/UPC
Number
Catalog
Number
78205141100
78205141110
78205141130
78205141132
78205141134
H7
H10
H30
H35
H40
Description
103
Hub Adapter AW To H-Base
H-Base Cap - Gray
3” Conduit
3 1/2” Conduit
4” Conduit
Stud/Lug Landing Pad Kits
H7
Part/UPC
Number
Catalog
Number
78205144475
ES38
3
78205144476
ES12
1
Description
/8” Stud, 3 Per Set
/2” Stud, 3 Per Set
H10
H30
ES12
Supplemental Ground Lug
Cap Set Screw Assemblies
Part/UPC
Number
Catalog
Number
Description
Part/UPC
Number
Catalog
Number
78205141670
TGK102
Supplemental Ground Lug
78205126400
EB125
For 125A, 2/0 Lay-In Lugs
12 pieces per set
78205126401
EB200
For 200A, 350 kcmil Lay-In Lugs
Description
12 pieces per set
TGK102
EB200
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
41
Meter Mounting - Midwest & Texas Utilities
Accessories
Cap Set Screw Assemblies with
Grounding Electrode Connector
5th Jaw Terminal Kits
Part/UPC
Number
Catalog
Number
78205144647
ETB125
For 125A, 2/0 Lay-In Lugs
78205144649
ETB200
For 200A, 350 kcmil Lay-In Lugs
Description
Part/UPC
Number
Catalog
Number
78205139465
50365
For Non-Lever Bypass 1Ø/3W Applications
78205139429
50366
For Lever Bypass 1Ø/3W Applications
Description
1 per kit
12 pieces per set
ETB200
50366
50365
Horned Bypass Cap Assemblies
7th Jaw Terminal Kits
Part/UPC
Number
Catalog
Number
Description
Part/UPC
Number
Catalog
Number
78205132343
EHB125
For 150A max / 125A cont., 2/0 Lay-In Lugs
78205144474
50368
78205132352
EHB200
For 250A max / 200A cont., 350 kcmil Lay-In Lugs
Description
For Lever Bypass 3Ø/4W Applications
1 kit per bag
12 pieces per set
50368
EHB200
Jumper Link
Touch-Up Paint
Part/UPC
Number
Catalog
Number
Description
Part/UPC
Number
Catalog
Number
Description
78205152102
SJ-100
100A & 200A Jumper Link
78205183012
84034
ANSI 61 Gray Touch-up Paint
1 piece per bag
SJ-100
Closing Plate
Part/UPC
Number
Catalog
Number
Description
78205139430
25162
Clear Plastic Closing Plate
84034
25162
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
Meter Mounting - Midwest & Texas Utilities
42
Miscellaneous Data
ANSI - S-Form Meter Configurations
4-Terminal
Form 1S & 2S
6-Terminal
Form 4S
5-Terminal
Form 3S
7-Terminal
Form 14S, 15S,
16S, 17S, 24S
8-Terminal
Form 5S, 35S, 45S
13-Terminal
Form 6S, 8S, 9S,
10S, 29S, 36S, 46S
15-Terminal
Form 11S, 39S, 76S
Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches.
43
Meter Mounting - Midwest & Texas Utilities
B-Line reserves the right to make changes to the specifications, materials, equipment, prices, or the
availabilityofproductsatanytimewithoutpriornotice.Whileeveryefforthasbeenmadetoassurethe
accuracyofinformationcontainedinthiscatalogatthetimeofpublication,wecannotacceptresponsibility
for inaccuracies resulting from undetected errors or omissions.
Meter Mounting - Midwest & Texas Utilities
For more information, visit
cooperbline.com/metering.
B-Line’s U.S. Customer Service Center is staffed Monday through Friday from 7 a.m. to 5 p.m. Central Standard Time.
Eaton’s B-Line Business
509 West Monroe Street
Highland,IL62249
United States
Phone:800-851-7415
www.cooperbline.com/contactus
Eaton
1000 Eaton Boulevard
Cleveland,OH44122
United States
Eaton.com
Eaton’s B-Line Business
509 West Monroe Street
Highland,IL62249
Eaton.com
© 2014 Eaton
All Rights Reserved
Printed in USA
PublicationNo.MTRTX-14
December2014
Eaton is a registered trademark.
All other trademarks are property
of their respective owners.