Technical Data Effective November 2014 X-Switch motor controllers & disconnect switches Project Name: Prepared By: Project Number: Date: Catalog Number: Type: Product description 3-pole, 3-phase NEMA 4X & NEMA 4X, 12 30A, 40A or 60A, 600V/AC max. Design features AH7810XC11S • Compact NEMA 4X stainless steel enclosure is ideal for washdown environments • High-visibility red handle can be padlocked to meet OSHA lockout/tagout requirements • Retained, quick-drive hex bolts for easy access • Multiple input & output configurations available • Mounting feet provide full 1/4” clearance from mounting surface • Optional breather drain prevents interior condensation buildup • Silicone gasket for superior ingress protection and easy cleaning • Heavy-duty industrial switches designed for long life • Fork terminals allow for easy phase changes • Optional auxiliary contact available (40A & 60A models only) Table 1. Common X-Switch Configurations* Catalog No. AH7810XC000 AH7810XC00S AH7810XC11S AHMC340XC0000 AHMC340XC00SA AHMC340XC1100 AHMC360XC0000 AHMC360XC1100 AHMC360XC00S0 Description X-switch: no input, no output, no breather drain X-switch: no input, no output, with breather drain X-switch: 3/4” input, 3/4” output, with breather drain X-switch: no input, no output, no breather drain, no aux. contacts X-switch: no input, no output, with breather drain, with aux. contacts X-switch: 1” input, 1” output, no breather drain, no aux. contacts X-switch: no input, no output, no breather drain, no aux. contacts X-switch: 1-1/4” input, 1-1/4” output, no breather drain, no aux. contacts X-switch: no input, no output, with breather drain, no aux. contacts Rating A V/AC 30 600 max. 30 600 max. 30 600 max. 40 600 max. 40 600 max. 40 600 max. 60 600 max. 60 600 max. 60 600 max. * Other configurations available Compliances, specifications and availability are subject to change without notice. Technical Data X-Switch motor controllers & disconnect switches Effective November 2014 Project Name: Prepared By: Project Number: Date: Catalog Number: Type: Table 2. Ordering matrix 3-Pole, 30A, 40A or 60A, 600 V/AC X-switch motor controllers & disconnects sample number: AHMC340XC11SA Amperage 7810 = 30A MC340 =40A MC360 =60A Arrow Hart NEMA 4X 40A switch, 1” pre-drilled input & output on bottom, breather drain, aux. contacts, 304 stainless steel enclosure Input options 0 = No input 1 = Pre-drilled thru hole, location: bottom (30A = 3/4", 40A = 1", 60A = 1-1/4") 2 = Pre-drilled thru hole, location: top (30A = 3/4”, 40A = 1”, 60A = 1-1/4”) AH MC340 Output options 0 = No output 1 = Pre-drilled thru hole, location: bottom (30A = 3/4", 40A = 1", 60A = 1-1/4") XC 1 Breather/drain 0 = No drain S = NEMA 4X stainless steel breather drain 1 S A Auxiliary contacts (40A & 60A models only) 0 = No Aux. contacts A = Aux. contacts Enclosure type None =Type 304 stainless steel (-316) =Type 316 stainless steel Applications The X-Switch is designed specifically for industrial manufacturing applications exposed to frequent washdown. It uses a UL 508 motor controller “suitable as motor disconnect” to comply with requirements of NEC® 430 (30A & 40A models). The X-Switch is ideal for food processing, storage and service. Applications include meat & poultry processing, dairy, bottling, bakeries, distilleries and commercial kitchens. The X-Switch also ideal for harsh environments such as mining, wastewater treatment, testing labs and heavy industrial manufacturing. The X-Switch enclosure is specially designed to prevent the penetration of external contaminants while delivering dependable motor control. A variety of input/output options including breather drains and pre-drilled holes provide for maximum flexibility and customization. Table 3. Specifications Device Type 30A , 40A & 60A X-switch motor controllers & disconnects Testing & code compliance • cULus Listed to UL 508, file no. E135083 • NSF evaluated for use in hose-down areas and to NSF/ANSI/3-A Standard 14159-1 Hygiene Requirements for the design of meat and poultry processing equipment Flammability: Meets UL 94 requirements; rated 94-5V Protection: Type 4X Maximum continuous current: 30A, 40A, 60A Endurance, mechanical: 10,000 cycles minimum Endurance, electrical: 6,000 cycles minimum Short cuircuit current rating (SCCR): Rated up to 50,000 RMS symmetrical amps, see chart Motor loads: Horsepower rated per UL 508, see chart Environmental specifications Electrical specifications Mechanical Specifications Terminal accommodation: (30A) #14 - 10 AWG; (40A) #14 - 4 AWG; (60A) #14 - 4 AWG; Voltage ratings: Permanently marked on device Table 4. Materials Device Type 30A , 40A & 60A X-switch motor controllers & disconnects Enclosure - body 16 gauge type 304 or 316 stainless steel Mounting feet Enclosure handle Enclosure - screws Lock-out/tag-out bracket Enclosure gasket Manual contactor terminal type Manual contactor terminal screws Manual contactor contacts Manual contactor moveable arm 11 gauge type 304 or 316 stainless steel Red nylon thermoplastic 300 Series stainless steel (captivated) 14 gauge type 304 or 316 stainless steel Silicone (closed cell) 30A - front-wire screw termination; 40A & 60A - box lug termination Nickel plated 260 brass Silver Brass 2 EATON www.arrowhart.com Compliances, specifications and availability are subject to change without notice. Technical Data X-Switch motor controllers & disconnect switches Project Name: Prepared By: Project Number: Date: Catalog Number: Type: Effective November 2014 Table 5. Optional equipment materials Device Type 30A , 40A & 60A X-switch motor controllers & disconnects Breather drain material Type 316 stainless steel Breather drain gasketing Captive “O” ring Table 6. Ratings Horsepower Ratings for Motor Loads per UL508 Short Circuit Current Ratings Poles/Phase X-Switch Amperage Horsepower Rating 120 V/AC 240 V/AC Voltage 3-Pole, 3-Phase 30A 600 V/AC 3 HP 3-Pole, 3-Phase 40A 600 V/AC 3-Pole, 3-Phase 60A 600 V/AC Auxiliary Contacts Rating Information (Switching Duty) Non-Inductive Load Voltage Resistive Load Lamp Load 480 V/AC 600 V/AC 7.5 HP 15 HP 15 HP 3 HP 7.5 HP 15 HP 20 HP 5 HP 10 HP 25 HP 30 HP Inductive Load Inductive Load Motor Load 250 V/AC 10A 1.5A 6A 2A 8 V/DC 10A 3A 6A 3A 30 V/DC 6A 3A 6A 3A 125 V/DC 0.6A 0.1A 0.6A 0.1A 250 V/DC 0.3A 0.05A 0.3A 0.05A 30A X-Switch SCCR: Suitable for use as a Motor Disconnect with the following short-circuit current ratings: • 5,000 RMS symmetrical amps, 600 VAC max when protected with 30A class RK5 fuses • 50,000 RMS symmetrical amps, 600 V/AC max. when protected with 30A class J fuses 40A X-Switch SCCR: Suitable for use as a Motor Disconnect with the following short-circuit current ratings: • 5,000 RMS symmetrical amps, 600 VAC max when protected with 40A class RK5 fuses • 50,000 RMS symmetrical amps, 600 V/AC max. when protected with 40A class J fuses 60A X-Switch SCCR: Suitable for use as a Motor Controller with the following short-circuit current ratings: • 5,000 RMS symmetrical amps, 600 VAC max when protected with 60A class RK5 fuses • 50,000 RMS symmetrical amps, 600 V/AC max. when protected with 60A class J fuses UL/IEC/EN 61058-1 Product Dimensions 6.00" (152.0mm) 7.00" (178.0mm) 5.00" (127.0mm) 6.00" (152.0mm) 6.00" (152.0mm) Mounting Depth 3.4" (87.0mm) 5.00" (127.0mm) 6.00" (152.0mm) 5.00" (127.0mm) 7.9" (200.0mm) 6.9" (175.0mm) Figure 1. 30A x-switch Compliances, specifications and availability are subject to change without notice. Mounting Depth 3.60" (91.0mm) Figure 2. 40A x-switch EATON www.arrowhart.com 3 Technical Data X-Switch motor controllers & disconnect switches Effective November 2014 Project Name: Prepared By: Project Number: Date: Catalog Number: Type: Product Dimensions 8.00" (203.0mm) 7.00" (178.0mm) 7.00" (178.0mm) Mounting Depth 4.00" (98.0mm) 6.00" (152.0mm) 8.9" (225.0mm) Figure 3. 60A x-switch Certifications & Compliances Catalog No. AH7810XC000 AH7810XC00S AH7810XC11S AHMC340XC0000 AHMC340XC00SA AHMC340XC1100 AHMC360XC0000 AHMC360XC1100 AHMC360XC00S0 KEY: cULus • • • • • • • • • • • • • • • • • • • • • • • • • • • NAFTA NSF Compliances, specifications and availability are subject to change without notice. Electrical Sector 203 Cooper Circle Peachtree City, GA 30269 United States Eaton.com Cooperwiringdevices.com Electrical Sector Canada Operations 5925 McLaughlin Road Mississauga, Ontario, L5R 1B8 Canada EatonCanada.ca Cooperwiringdevices.com © 2014 Eaton All Rights Reserved Printed in USA Publication No. E125-0254-14 November 2014 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Electrical Sector Mexico Operations Carr. Tlalnepantla Cuautitlan Km 17.8 s/n Col. Villa Jardin esq. Cerrada 8 de Mayo Cuautitlan, Mexico CP 54800 Mexico Eaton.mx Cooperwiringdevices.com Eaton is a registered trademark. All other trademarks are property of their respective owners.