0057-2852-MTDC September 2000 5100/5700 Airtanker United States Department of Agriculture Forest Service Drop Guides Technology & Development Program Ground Pattern Performance of the Snow Air Tractor with Constant Flow Tank Paul Solarz, Project Leader, and Cammie Jordan, Project Assistant T he Wildland Fire Chemical Systems (WFCS) program tests a variety of fixed- and rotary-wing tankers to determine the parameters for optimal ground pattern coverage over a wide range of fuel and fire conditions. The Snow Air Tractor AT-802F, owned and operated by Queen Bee Air Specialties, is one of a family of smaller airtankers used for initial attack fire suppression. The Snow Air Tractor fire retardant door system contains a constant flow tank made of stainless steel. The 800-gallon single tank is divided into two hoppers with a connecting lower section. Two opposing doors that hinge on the airtanker’s longitudinal axis are used to control the flow. The drop system control panel allows the pilot to select coverage level settings of 0.5 to 4 (77 to 450 gal/sec) or a salvo drop, which opens the doors completely. A hydraulic system actuates the door opening. The control system specifies the amount of retardant to be dropped, coverage level, and ground speed. Tests included airspeeds from 78 to 87 knots (90 to 100 mph) and drop heights from 40 to 113 feet (measured from the bottom of the tank to ground). The drops were made with three different materials: water, foam, and gumthickened retardant. The Missoula Technology and Development Center tested the Snow Air Tractor (Figure 1) with a series of drops over an array of plastic bowls much like Cool Whip containers. The quantity of material in each bowl was measured and the data were used to determine the drop pattern. Figure 1 100% 4.875 x 2.488 Original Photo 5x3.5 Print to Outside Edge of Borders No Not Print Borders Figure 1 —The constant flow tank for the AeroUnion SP-2H. Flow rate, drop height, and airspeed affect the drop pattern. Increasing the drop height gradually widens the drop while decreasing the coverage levels. This effect is modified by the ambient wind. Increasing windspeed widens the drop and decreases coverage levels. Increasing airspeed increases the line length while reducing the coverage level. Because this airtanker has variable flow rates, it can produce specific coverage levels needed for accurate drops using all of the liquid in the tank. Figures 2, 3, 4, 5 and 6 show the effect of increasing the coverage level setting from 0.5 to 4. The proper amount of fire-retarding material (expressed as coverage levels in gallons per 100 square feet) differs depending on the fuel model. Table 1 shows the coverage needed for specific fuel models using both the National Fire Danger Rating System (NFDRS) and the Fire Behavior Fuel Model. For additional Information contact: Greg Lovellette, Project Leader; Missoula Technology & Development Center; 5785 Hwy 10 W; Missoula, MT 59808 Phone: 406-329-4815; Fax: 406-329-4811; E-mail: glovellette@fs.fed.us; Lotus Notes: Greg Lovelletteß/WO/USDAFS 1 Table 1—Retardant coverage levels needed for specific fuel models. Fuel Model National Fire Danger Rating System (NFDRS) Fire Behavior Coverage Level (gal/100 sq. ft) A,L,S 1 C 2 H,R 8 E,P,U 9 Longneedle conifer; fall hardwood T 2 Sagebrush with grass N 3 Sawgrass F 5 K 11 G 10 O 4 F,Q 6 B,O 4 J 12 I 13 The results of drop tests allow managers to estimate the length of line a specific airtanker produces at various coverage levels. Table 2 or 1 Description Annual and perennial western grasses, tundra Conifer with grass 2 3 Shortneedle closed conifer; summer hardwood Intermediate brush (green) Light slash 4 Shortneedle conifer (heavy dead litter) Southern rough 6 Intermediate brush (cured), Alaska black spruce California mixed chaparral, high pocosin Greater than 6 Medium slash Heavy slash Figure 7 can be used to estimate the flow rate for a water drop to obtain the longest line of the desired coverage level. Table 3 or Figure 8 Table 2–Water tests producing the longest line at various flow rate settings using a constant flow tank. Coverage Level (gal/100 sq. ft) Flow Rate (gal/sec) Coverage Level (setting) Drop Length (feet) 0.5 1.0 2.0 3.0 4.0 6.0 8.0 10.0 77 77 277 277 405 405 450 450 0.5 0.5 2 2 3 4 4 4 1604 1075 484 339 262 102 28 10 Table 3–Foam tests producing the longest line at various coverage level settings using a constant flow tank. Coverage Level (gal/100 sq. ft) Flow Rate (gal/sec) Coverage Level (setting) Drop Length (feet) 0.5 1.0 2.0 3.0 4.0 6.0 8.0 10.0 77 140 277 277 405 405 405 - 0.5 1 2 2 3 3 3 - 1602 940 437 319 171 31 2 0 can be used to estimate the flow rate for a foam drop to obtain the longest line of the desired coverage level. Table 4 or Figure 9 can be used to estimate the flow rate for a gumthickened retardant drop to obtain the longest line of the desired coverage level. 2 Table 4–Gum-thickened retardant test producing the longest line at various flow rate settings using a constant flow tank. Coverage Level (gal/100 sq. ft) Flow Rate (gal/sec) Coverage Level (setting) Drop Length (feet) 0.5 1.0 2.0 3.0 4.0 6.0 8.0 10.0 77 77 140 277 405 450 450 450 0.5 0.5 1 2 3 4 4 4 1710 1536 608 423 274 156 82 68 Snow Air Tractor With Constant Flow Tank 120 120 2.0 60 1.0 1.0 0.5 0 0 200 400 600 800 1.0 1.0 Width (feet) Coverage Level Setting 0.5 1.0 60 0 1000 1200 1400 1600 1800 2000 Length (feet) Figure 2–Drop pattern characteristics for the Snow Air Tractor with a coverage level setting of 0.5, an airspeed of 85 knots (98 mph), and a drop height of 46 feet. The contour lines are at coverage levels of 0.5, 1, 2, 3, 4, 6, 8, and 10 gallons per 100 square feet. The graphs predict line length (in feet) as a function of flow rate (in gal/sec). The tables are constructed by selecting the drop producing the longest line (on the ground) at each coverage level. Either the graphs or tables may be used to estimate the flow rate required to produce the longest line for a given coverage level. The tables show an ideal case, while the graphs represent an average. To select the proper flow rate, first use Table 1 to determine the coverage level required by the NFDRS or Fire Behavior Fuel Model. The coverage levels in Table 1 represent the coverage level required for average fire intensity for each fuel model. The required coverage level can be adjusted up or down depending on the actual fire intensity. Once the required coverage level is determined, the flow rate can be found. Use the graph for the material dropped (water, foam, or gum-thickened retardant) to find the flow rate that produces the longest line for the desired coverage level. The same information can be found in the appropriate drop table. 3 Snow Air Tractor With Constant Flow Tank Width (feet) Coverage Level Setting 1 120 60 2.0 2.0 1.0 0 .5 120 60 0 0 0 200 400 600 800 1000 Length (feet) 1200 1400 1600 1800 2000 Figure 3–Drop pattern characteristics for the Snow Air Tractor with a coverage level setting of 1, an airspeed of 85 knots (98 mph), and a drop height of 90 feet. The contour lines are at coverage levels of 0.5, 1, 2, 3, 4, 6, 8, and 10 gallons per 100 square feet. Coverage Level Setting 2 0 120 0 1. 3. Width (feet) Snow Air Tractor With Constant Flow Tank 60 3.0 120 3.0 .0 2 .5 60 0 0 0 0 200 400 600 800 1000 Length (feet) 1200 1400 1600 1800 2000 Figure 4–Drop pattern characteristics for the Snow Air Tractor with a coverage level setting of 2, an airspeed of 87 knots (100 mph), and a drop height of 99 feet. The contour lines are at coverage levels of 0.5, 1, 2, 3, 4, 6, 8, and 10 gallons per 100 square feet. For example, if a fire is burning in NFDRS Fuel Model C (Fire Behavior Model 2), represented by conifer with grass, a coverage level of 2 is required (Table 1). The graph for gum-thickened retardant shows that for coverage level 2, a coverage level setting of 1 produces the longest line (608 feet). The ground drop characteristics for the Snow Air Tractor were derived through controlled drop test procedures on flat ground (Figure 10). This information is to serve only as a guide to help field personnel determine the proper drop height, airspeed, and door opening for delivering water, foam, or gumthickened retardant. Actual coverage may vary depending on terrain, wind, weather, a nd pilot proficiency. 4 Snow Air Tractor With Constant Flow Tank Width (feet) Coverage Level Setting 3 4. 2.0 3.0.0 0 1 0.5 120 60 120 60 0 0 0 200 400 600 800 1000 Length (feet) 1200 1400 1600 1800 2000 Figure 5–Drop pattern characteristics for the Snow Air Tractor with a coverage level setting of 3, an airspeed of 81 knots (93 mph), and a drop height of 110 feet. The contour lines are at coverage levels of 0.5, 1, 2, 3, 4, 6, 8, and 10 gallons per 100 square feet. Snow Air Tractor With Constant Flow Tank Width (feet) Coverage Level Setting 4 2.0 3.0 4.0 1.0 0.5 120 60 120 60 0 0 0 200 400 600 800 1000 1200 1400 1600 1800 2000 Length (feet) Figure 6–Drop pattern characteristics for the Snow Air Tractor with a coverage level setting of 4, an airspeed of 78 knots (90 mph), and a drop height of 113 feet. The contour lines are at coverage levels of 0.5, 1, 2, 3, 4, 6, 8, and 10 gallons per 100 square feet. 5 Effect of Flow Rate on Length of Line at Various Coverage Levels Effect of Flow Rate on Length of Line at Various Coverage Levels 1750 Snow Air Tractor With Constant Flow Tank Using Foam Snow Air Tractor With Constant Flow Tank Using Water 1750 1575 CL = 0.5 CL = 1 CL = 2 CL = 3 CL = 4 CL = 6 CL = 8 1400 1050 1400 CL = 0.5 CL = 1 CL = 2 CL = 3 CL = 4 CL = 6 1225 CL = Coverage Level Line Length (feet) Line Length (feet) 1225 1575 875 700 1050 CL = Coverage Level 875 700 525 525 350 350 175 175 0 75 150 225 300 375 450 0 75 Flow Rate (gal/sec) Figure 7–Use this graph to estimate the flow rate needed to produce the longest line of water at various coverage 150 225 300 375 450 Flow Rate (gal/sec) Figure 8–Use this graph to estimate the flow rate needed to produce the longest line of foam at various coverage levels. 6 Effect of Flow Rate on Length of Line at Various Coverage Levels Snow Air Tractor With Constant Flow Tank Using Gum-Thickened Retardant 1750 CL = 0.5 CL = 1 CL = 2 CL = 3 CL = 4 CL = 6 CL = 8 CL = 10 1575 1400 Line Length (feet) 1225 1050 CL = Coverage Level 875 700 525 350 175 0 75 150 225 300 375 450 Flow Rate (gal/sec) Figure 9–Use this graph to estimate the flow rate needed to produce the longest line of gumthickened retardant at various coverage levels. 7 About the Authors Figure 10 83% 4.875 x 5.348 Original Photo 8 1/2 x 11 Print to Outside Edge of Borders No Not Print Borders Paul Solarz is Program Leader for the Wildland Fire Chemical Systems Group. He received his bachelor’s degree from Eastern Oregon State College in 1986. Paul has worked in Aviation and Fire Management since 1973, serving at seven Ranger Districts and in two Forest Supervisor’s offices. He has an extensive operational background in fire, fuels, and aviation. Additional single copies of this document may be ordered from: USDA Forest Service Missoula Technology and Development Center 5785 Hwy 10 W Missoula, MT 59808 Phone: (406) 329-3978 Fax: (406) 329-4811 Internet: wo_mtdc_pubs@fs.fed.us Figure 10–Drop test of the Aero Union SP-2H. The Forest Service, United States Department of Agriculture, has developed this information for the guidance of its employees, its contractors, and its cooperating Federal and State agencies, and is not responsible for the interpretation or use of this information by anyone except its own employees. The use of trade, firm, or corporation Cammie Jordan is a Project Assistant for the Wildland Fire Chemical Systems Program at MTDC. She is currently enrolled at the University pursuing a bachelorís degree in Elementary Education with a Special Education Endorsement. She has worked for MTDC in Missoula since 1998. names in this publication is for the information and convenience of the reader, and does not constitute an endorsement by the Department of any product or service to the exclusion of others that may be suitable. The United States Department of Agriculture (USDA), prohibits discrimination in all its programs and activities on the basis of race, color, national origin, sex, religion, age, disability, political beliefs, sexual orientation, and marital or family status. (Not all prohibited bases apply to all programs.) Persons with disabilities who require alternative means for communication of program information (Braille, large print, audiotape, etc.) should phone USDA’s TARGET Center at (202) 720- For additional technical information, contact Greg Lovellette at the address above. Phone: (406) 329-4815 Fax: (406) 329-4811 Lotus Notes: Greg Lovellette/WO/ USDAFS Internet: glovellette@fs.fed.us An electronic copy of this document is available on the Forest Service s FSWeb Intranet at: http://fsweb.mtdc.wo.fs.fed.us For additional Information contact: Greg Lovellette, Project Leader Missoula Technology & Development Center 5785 Hwy 10 W Missoula, MT 59808 Phone: 406-329-4815 Fax: 406-329-4811 E-mail: glovellette@fs.fed.us Lotus Notes: Greg Lovellette/WO/ USDAFS 2600 (voice and TDD). To file a complaint of discrimination, write: USDA, Director, Office of Civil Rights, Room 326-W, Whitten Building, 1400 Independence Avenue, SW, Washington, DC 20250-9410, or call (202) 720-5964 (voice and TDD). USDA is an equal opportunity provider and employer. 8