Building Consistency Meeting Residential Date: 8/3/2005 Recorder: Danny Wooten, minutes prepared by: Jeff Griffin Staff present: Jeff Griffin; Gene Morton; George Rogers; Danny Wooten; Ron Dishman; Harold Sinclair; David Morton; Steve Kellen; George Rogers; Eric Brown. Public present: Frank Burke (Grimmer-Kempf & Assoc); David Schwiemon (Public); Daniel Mcbridge (The Cunnane Group); Bob Mckee (Ryan Homes); Chad Nelson (Shea Homes); Tony Smith (Hobart Smith); Shawn Polakiewicz (Saussy Burbank); Dave Reynolds/Toby Brundage (Builder 1st Source); Steve Corriher (CPCC); Mike Mcgee/Doc Mcgee/Michael Watkins (Mcgee Brothers); Bill Green (Barefoot Co.); Stu Jelenick (BRI); Bob Otto (NARI-representative); Adam Kuhn/Dave Patterson (Craft Homes). Topics/Subject Decisions/Conclusions/Actions Old Business Insulation vapor barrier The NC Building Code Council has approved the removal of the interior vapor barrier in most of the State. This code change can now be accepted in Mecklenburg County which will no longer require the installation of a paper face product or 4 mil poly coverage on wall cavities. New Business Code Update Final enforcement date for the next residential Code change is scheduled for June 1st, 2006. With this the requirement for Low E glazing will be required (SHGC). • NC Code Commentary-work will begin on developing a Code Commentary (State residential Ad Hoc Committee) that • • • explains/illustrates many sections of the code to help with interpretations and Code intent. Work will begin in October on the 1st NC version of a commentary and hope to have out with the Code change next year. Deck Code appendix M-Cantilever section of the code has been changed as far as item #9. There is a new cantilever section in chapter 5 of the Code that will allow for 2x8 and other lengths of cantilevered floor systems. This will also be allowed to be used when building decks. Table 602.10.5- Committee moved to keep this table as it relates to a single wall line the same as is currently used. New version of the Code had language that if you could not get your bracing like at garage lugs then you could use this table only if you completely sheathed the entire house with OSB/plywood. Currently it looked at as only that braced wall line has to be all plywood/OSB. Appendix P cantilevers has been deleted completely in 2006 Code. Closed crawl spaces Closed crawl spaces are currently being installed and are permitted now; see Code changes on DOI website for the September 2004 building Code council minutes. The issue that has recently come up is that this is being installed way too early. A sealed crawl space cannot have walls and floor covered before the foundation inspection has passed. It also is not practical to have the floor covered until after frame due to the likelihood that liner will trap moisture under the house (house not dried in) and that trades may damage liner. Foundations that are covered over, meaning poly and foam on walls, prior to foundation inspection will be turned down. CPCC Code change training Discussed efforts to put together a 1/2 day training class on just dealing with the Code changes in the 2006 NC Code. Intent is to have something available to builders through CPCC that can be taught on campus or at builder’s offices and be ready by March of 2006. Will let builders know once this course has been set up. Question raised about porch suspended slabs and if inspection is required. General rule is if space under the slab can be seen at a later time like at final with crawl access then not generally required. If suspended slab well area cannot be seen then it should be checked prior to concrete placement. This question was asked as a follow up to the effective date of any Code change and the issue date of the permit applies to the code being enforced at that time. Question presented to mechanical and they will require 13 SEER system on any permits issued after January 1, 2006. Suspended slab porch inspections Mechanical system requirement 13SEER Next meeting is on September 7th Woods room 1st floor at 8:00am, 700 N. Tryon St.