MECKLENBURG COUNTY Land Use and Environmental Services Agency Code Enforcement ______________________________________________________________________________ CODE INTERPRETATION Mechanical/Plumbing Code Volume Reference: NC Residential 2009 Code Chapter Reference: R606.10 Subject: Lintels on Package Equipment Effective Date: 2/1/2000 Prepared/Revision Date: 3/26/2009 CODE: 604.10 Lintels. Masonry over openings shall be supported by steel lintels, reinforced concrete or masonry lintels or masonry arches, designed to support load imposed. INTERPRETATION: Any outdoor HVAC equipment, whose duct system penetrates the outside masonry wall shall have the masonry above the penetration supported with a steel, concrete or masonry lintel as approved by the building section 604.10 of the 2009 NC Residential Building Code. Steel lintels must extend a minimum of three inches (3”) into undisturbed masonry on each side of the penetration. Prepared by: Consistency Team Approved by: Philip B. Edwards, M/P Code Administrator