• Charles D. Baker. Governor l<aryn E. Polito, Lieutenant Governor Stephanie Pollack, Secretary & CEO Thomas Tinlin, Acting Administrator • #J~IJ1i!!~!2QI ~~ighway Division April 11, 201S Mr. Stephen Aissis Quality Control Technician Morse Ready Mix, LLC P.O. Box 2189 Plainville, MA 02762-0296 Dear Sir, The following cement concrete mix design submittals have been reviewed by this section and are approved as specified below, subject to perfonnanc'e at the plant, on the project or in the laboratory. Any changes will require new mix design submittals and trial batches. Approved Plant Location: MORSE READY MIX - PLAINVILLE, MA Approved Cementitious & Mitigating Materials: CI: TYPE I I 11 DRAGON PRODUCTS - THOMASTON, ME; FA: TYPE F HEADWATERS RESOURCES ­ SOMERSET, MA; SLAG: TYPE 120 LAFARGE NEWCEM - BAL TIM ORE, MD; SF: SIKACRETE 9SODP ­ LYNDHURST, NJ Approved Aggregates: FINE: BYRNE SAND AND GRAVEL - MIDDLEBORO, MA; 3/8": MORSE SAND AND GRAVEL ­ ATTLEBORO, MA; 3/4": MORSE SAND AND GRAVEL - ATTLEBORO, MA; I .S": MORSE SAND AND GRAVEL-ATTLEBORO, MA Approved Admixtures: ADI: TYPE C260 SIKA - SIKA AEA-14; AD2: TYPE A,F SIKA - SIKAMENT 686; AD3: TY.PE A,F SIKA ­ VISCOCRETE 2100; AD4: TYPE D SIKA - PLASTIMENT; ADS: TYPE C SIKA - SIKA CNI; AD6: TYPE C,E SIKA - SIKASET NC; AD7: TYPES W.R. GRACE - DARAFILL Approved Mix Designs: 1.) 3000PSI;3/4";CI: 400LBS.;FAI: 2.) 3000 PSI; 1.S"; Cl: 400 LBS.; FA!: 3.) 3SOO PSI; 314"; Cl: 426 LBS.; FA!: 4.) 3SOO PSI; 1.S"; Cl: 426 LBS.; FA!: S.) 4000 PSI; 314"; Cl: S26 LBS.; FA!: 6.) 4000 PSI; HP; 314"; Cl: 468 LBS.; ADS: 384 OZ. 7.) 4000 PSI; 1.S"; Cl: S26 LBS.; FA!: 8.) 4000 PSI; HP; 1.S"; Cl: 468 LBS.; ADS: 384 OZ. IOOLBS.;ADI: 1.30Z.;AD2: 3SOZ. 100 LBS.; ADI: 1.3 OZ.; AD2: 3S OZ. 106 LBS.; ADI: 1.6 OZ.; AD2: 37.2 OZ. 106 LBS.; ADI: 1.3 OZ.; AD2: 37.2 OZ. 132 LBS.; ADI: 3.9 OZ.; AD2: 46 OZ. FA!: 82 LBS.; SF: 3S LBS.; ADI: 4 OZ.; AD3: 2S OZ.; AD4: 11 OZ.; 132 LBS.; ADI: 2.7 OZ.; AD2: 46 OZ. FA!: 82 LBS.; SF: 3S LBS.; ADI: S OZ.; AD3: 2S OZ.; AD4: 11 OZ.; Leading the Nation in Transportation Excellence Four Hundred D Street, Boston, MA 02110 Tel: 617-951-0590, TDD: 617-973-7306 www.mass.gov/massdot • Charles D. Baker, Governor Karyn E. Polito. Lieutenant Governor Stephanie Pollack. Secretary & CEO Thomas lTnlin. Acting Administrator • ~~IJlf!!!..!lQI ~~ighway Division 9.) 4000 PSI; HIGH SLUMP; 314"; Cl: S26 LBS.; FAI: 132 LBS.; ADI: .1.3 OZ.; AD3: 26.3 OZ. 10.) 4000PSI;3/8";Cl: S64LBS.;FA1: 141 LBS.;ADI: 2.30Z.;AD2: 490Z. 11.) 4000 PSI; TREMIE; 3/8"; Cl: S64 LBS.; FAI: 141 LBS.; ADI: O.S OZ.; AD3: 28 OZ.; AD4: 49 OZ. 12.) 4000 PSI; HP; 3/8"; Cl: S40 LBS.; FAI: 9S LBS.; SF: 40 LBS.; ADI: 1.6 OZ.; AD3: 29 OZ. ; AD4: OZ.; ADS: 384 OZ. 13.) SOOO PSI; HP; 3/8"; Cl: S68 LBS.; FAI: 99 LBS.; SF: 43 LBS.; ADI: 1.7 OZ.; AD3: 30 OZ. · AD4: OZ.; ADS: 384 OZ. 14.) SOOO PSI; 3/4"; Cl: S64 LBS.; FAI: 141 LBS.; ADI: 2.1 OZ.; AD2: 49 OZ. IS.) SOOO PSI; HP; 314"; Cl: S48 LBS.; FAI: 96 LBS.; SF: 41 LBS.; ADI: 1.6 OZ.; AD3: 29 OZ.; AD4: OZ.; ADS: 384 OZ. 16.) ; CDF; Cl: 100 LBS. ; AD7: 3 OZ. 17.) 3000 PSI; 314"; Cl: 2SO LBS.; SLAG: 2SO LBS.; ADI: 1.3 OZ.; AD2: 3S OZ. 18.) 3000 PSI; 1.S"; Cl: 2SO LBS.; SLAG: 2SO LBS.; ADI: 1.3 OZ.; AD2: 3S OZ. 19.) 3SOO PSI; 314"; Cl: 266 LBS.; SLAG: 266 LBS.; ADI: 1.6 OZ.; AD2: 37.2 OZ. 20.) 3SOO PSI; 1.S"; Cl: 266 LBS.; SLAG: 266 LBS.; ADI: 1.3 OZ.; AD2: 37.2 OZ. 21.) 4000 PSI; 314"; Cl: 329 LBS.; SLAG: 329 LBS.; ADI: 3.9 OZ.; AD2: 46 OZ. 22.) 4000 PSI; HP; 3/4" ; Cl: 293 LBS.; SLAG: 2S7 LBS.; SF: 3S LBS.; ADI: 4 OZ.; AD3: 2S OZ. ; AD4: OZ.; ADS: 384 OZ. 23.) 4000 PSI; 1.S"; Cl: 329 LBS.; SLAG: 329 LBS.; ADI: 2.7 OZ. ;·AD2: 46 OZ. 24.) 4000 PSI; HP; 1.S"; Cl: 293 LBS.; SLAG: 2S7 LBS.; SF: 3S LBS.; ADI: S OZ.; AD3: 2S OZ. ; AD4: OZ.; ADS: 384 OZ. 2S.) 4000 PSI; HIGH SLUMP; 314"; Cl: 329 LBS.; SLAG: 329 LBS.; ADI: 1.3 OZ.; AD3: 26.3 OZ. 26.) 4000 PSI; 3/8"; Cl: 3S3 LBS.; SLAG: 3S3 LBS.; ADI: 2.3 OZ.; AD2: 49 OZ. 27.) 4000 PSI; TREMIE; 3/8"; Cl: 3S3 LBS.; SLAG: 3S3 LBS. ; ADI: O.S OZ.; AD3: 28 OZ.; AD4: 49 OZ. 28.) 4000 PSI; HP; 3/8" ; Cl: 338 LBS.; SLAG: 297 LBS.; SF: 40 LBS.; ADI: 1.6 OZ.; AD3: 29 OZ.; AD4: OZ.; ADS: 384 OZ. 29.) SOOO PSI; HP; 3/8" ; Cl: 3SS LBS.; SLAG: 312 LBS.; SF: 43 LBS.; ADI: 1.7 OZ.; AD3: 30 OZ.; AD4: OZ. ; ADS: 384 OZ. 30.) SOOO PSI; 3/4"; Cl: 3S3 LBS.; SLAG: 3S3 LBS.; ADI: 2.1 OZ.; AD2: 49 OZ. 31.) SOOO PSI; HP; 3/4" ; Cl: 343 LBS.; SLAG: 301 LBS.; SF: 41 LBS.; ADI: 1.6 OZ.; AD3: 29 OZ.; AD4: OZ.; ADS: 384 OZ. r1·~· ii fp,,,, Director of Research and Materials RFM/ms/wk Attachments C: District S Materials Engineer R&M Job File Leading the Nation in Transportation Excellence Four Hundred D Street, Boston, MA 02110 Tel: 617-951-0590, TDD: 617-973-7306 www.mass.gov/ massdot 13 14 13 11 11 13 14 13 • Charles D. Baker, Governor Karyn E. Polito. Lieutenant Governor Stephanie Pollack. Secretary & CEO Thomas "Tinlin. Acting Administrator •IJ.~IJli!.@.QI .I~ighway Division April 11, 201S Mr. Stephen Aissis Quality Control Technician Morse Ready Mix, LLC P.O. Box 2189 Plainville, MA 02762-0296 Dear Sir, The following cement concrete mix design submittals have been reviewed by this section and are approved as specified below, subject to performance at the plant, on the project or in the laboratory. Any changes will require new mix design submittals and trial batches. Approved Plant Location: MORSE READY MIX - PLAINVILLE, MA Aporoved Cementitious & Mitigating Materials: Cl: TYPE I I II DRAGON PRODUCTS - THOMASTON, ME; FA: TYPE F HEADWATERS RESOURCES ­ SOMERSET, MA; SLAG: TYPE 120 LAFARGE NEWCEM - BALTIMORE, MD; SF: SIKACRETE 9SODP ­ LYNDHURST, NJ Approved Aggregates: FINE: BYRNE SAND AND GRAVEL - MIDDLEBORO, MA; 3/8": MORSE SAND AND GRAVEL ­ ATTLEBORO, MA; 3/4": MORSE SAND AND GRAVEL - ATTLEBORO, MA; 1.S": MORSE SAND AND GRAVEL-ATTLEBORO, MA Approved Admixtures: AD I: TYPE C260 W. R. GRACE - DA REX II AEA; AD2: TYPE A,F W. R. GRACE - ADV A 140 (M); AD3: TYPE F W.R. GRACE- EXP 9SO; AD4: TYPE B,D W.R. GRACE- DARATARD 17; ADS: TYPE CW. R. GRACE- DCI S; AD7: TYPES W. R. GRACE - DARAFILL Approved Mix Designs: I.) 3000 PSI; 3/4"; Cl: 400 LBS.; FAI: 100 LBS.; ADI: 1.3 OZ.; AD2: 3S OZ. 2.) 3000 PSI; l.S"; Cl: 400 LBS.; FAI: 100 LBS.; ADI: 1.3 OZ.; AD2: 3S OZ. 3.) 3SOOPSI;3/4";CI: 426LBS.;FAI: 106LBS.;ADI: l.60Z.;AD2: 37.20Z. 4.) 3SOOPSI;l.S";Cl: 426LBS.;FA1: 106LBS.;ADI: l.30Z.;AD2: 37.20Z. S.) 4000 PSI; 3/4"; Cl: S26 LBS.; FA!: 132 LBS.; ADI: 3.9 OZ.; AD2: 39.S OZ. 6.) 4000 PSI; HP; 314"; Cl: 468 LBS.; FAI: 82 LBS.; SF: 3S LBS.; ADI: 4 OZ.; AD3: 2S OZ.; AD4: 11 OZ.; ADS: 384 OZ. 7.) 4000 PSI; l.S"; Cl: S26 LBS.; FAI: 132 LBS.; ADI: 2.7 OZ.; AD2: 46 OZ.; AD3: 13 OZ. 8.) 4000 PSI; HP; 1.S"; Cl: 468 LBS.; FA!: 82 LBS.; SF: 3S LBS.; ADI: S OZ.; AD3: 2S OZ.; AD4: 11 OZ.; ADS: 384 OZ. Leading the Nation in Transportation Excellence Four Hundred D Street, Boston, MA 021 10 Tel: 617-951-0590, TDD: 617-973-7306 www.mass.gov/massdot Charles D. Baker. Governor Karyn E. Polito. Lieutenant Governor Stephanie Pollack. Secretary & CEO Thomas Tinlin. Acting Administrator • ~;y!!E!~~QQI ~~ighway Division 9.) 4000 PSI; 3/4"; Cl: S26 LBS.; FAI: 132 LBS.; ADI: 1.3 OZ. ; AD3: 26.3 OZ. 10.) 4000PS1;3/8";Cl: S64LBS.;FA1: 141 LBS.;ADI: 2.30Z.;AD2: 490Z.;AD3: 140Z. 11.) 4000 PSI; TREMIE ; 3/8"; Cl: S64 LBS.; FAI: 141 LBS.; ADI: 0.1 OZ.; AD3: 28 OZ.; AD4: 49 OZ. 12.) 4000 PSI; HP; 3/8" ; Cl: S40 LBS.; FAI: 9S LBS.; SF: 40 LBS.; ADI: 1.6 OZ.; AD3: 29 OZ.; AD4: OZ.; ADS: 384 OZ. 13.) SOOO PSI; HP; 3/8" ; Cl: S68 LBS.; FAI: 99 LBS.; SF: 43 LBS.; ADI: 1.7 OZ.; AD3: 30 OZ.; AD4: OZ.; ADS: 384 OZ. 14.) SOOO PSI; 3/4"; Cl: S64 LBS.; FAI: 141 LBS.; ADI: 2.1 OZ. ; AD2: 49.4 OZ.; AD3: 14 OZ. IS.) SOOO PSI; HP; 3/4" ; Cl: S48 LBS.; FAI: 96 LBS.; SF: 41 LBS.; ADI: 1.6 OZ.; AD3: 29 OZ.; AD4: OZ.; ADS: 384 OZ. 16.) ;CDF;Cl: IOOLBS. ; AD7: 30Z. 17.) 3000 PSI; 3/4"; Cl: 2SO LBS.; SLAG: 2SO LBS.; ADI: 1.3 OZ.; AD2: 3S OZ. 18.) 3000 PSI ; 1.S" ; Cl: 2SO LBS.; SLAG: 2SO LBS.; ADI: 1.3 OZ.; AD2: 3S OZ. 19.) 3SOO PSI ; 3/4" ; Cl: 266 LBS.; SLAG: 266 LBS.; ADI: 1.6 OZ.; AD2: 37.2 OZ. 20.) 3SOO PSI ; l.S" ; Cl: 266 LBS.; SLAG: 266 LBS.; ADI: 1.3 OZ.; AD2: 37.2 OZ. 21.) 4000 PSI ; 3/4" ; Cl: 329 LBS.; SLAG: 329 LBS.; ADI: 3.9 OZ.; AD2: 39.S OZ. 22.) 4000 PSI ; HP ; 314" ; Cl: 293 LBS.; SLAG: 2S7 LBS.; SF: 3S LBS.; ADI: 4 OZ.; AD3: 2S OZ. ; AD4: OZ. ; ADS: 384 OZ. 23.) 4000 PSI ; 1.S" ; Cl: 329 LBS.; SLAG: 329 LBS.; ADI: 2.7 OZ.; AD2: 46 OZ.; AD3: 13 OZ. 24.) 4000 PSI ; HP ; 1.S" ; Cl: 293 LBS.; SLAG: 2S7 LBS.; SF: 3S LBS.; ADI: S OZ.; AD3: 2S OZ. ; AD4: OZ. ; ADS: 384 OZ. 2S.) 4000 PSI; 314" ; Cl: 329 LBS.; SLAG: 329 LBS.; ADI: 1.3 OZ.; AD3: 26.3 OZ. 26.) 4000 PSI ; 3/8" ; Cl: 3S3 LBS.; SLAG: 3S3 LBS.; ADI: 2.3 OZ.; AD2: 49 OZ.; AD3: 14 OZ. 27.) 4000 PSI ; TREMIE ; 3/8"; Cl: 3S3 LBS.; SLAG: 3S3 LBS. ; ADI: 0.1 OZ.; AD3: 28 OZ.; AD4: 49 OZ. 28.) 4000 PSI; HP; 3/8"; Cl: 338 LBS.; SLAG: 297 LBS.; SF: 40 LBS.; ADI: 1.6 OZ.; AD3: 29 OZ.; AD4: OZ.; ADS: 384 OZ. 29.) SOOO PSI; HP; 3/8"; Cl: 3SS LBS.; SLAG: 312 LBS.; SF: 43 LBS.; ADI: 1.7 OZ.; AD3: 30 OZ.; AD4: OZ. ; ADS: 384 OZ. 30.) SOOO PSI; 3/4"; Cl: 3S3 LBS.; SLAG: 3S3 LBS.; ADI: 2.1 OZ.; AD2: 49.4 OZ.; AD3: 14 OZ. 31.) SOOO PSI; HP; 314"; Cl: 343 LBS.; SLAG: 301 LBS.; SF: 41 LBS.; ADI: 1.6 OZ.; AD3: 29 OZ.; AD4: OZ.; ADS: 384 OZ. rf.~. ti'~ Director of Research and Materials RFM/ms/wk Attachments C: District S Materials Engineer R&M Job File Leading the Nation in Transportation Excellence Four Hundred D Street. Boston. MA 02 I I 0 Tel: 6I7-951-0590, TDD: 6 I 7-973-7306 www.mass.gov/ massdot 13 14 13 11 11 13 14 13