www.awc.org AWC’s 2008 Special Design Provisions for Wind and Seismic ASD/LRFD – Part 1: Overview and Changes from Previous Editions Copyright © 2013 American Wood Council 1 www.awc.org Copyright Materials This presentation is protected by US and International Copyright laws. Reproduction, distribution, display and use of the presentation without written permission of AWC prohibited. © American Wood Council 2013 Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 2 www.awc.org Learning Objectives On completion of this course, participants will: 1. Be able to understand load path basics and how it applies to wood structural design. 2. Be familiar with the significant changes between the 2005 and 2008 SDPWS. 3. Be able to identify the lateral resisting systems and understand where to obtain design specifications for these systems 4. Be able to analyze format and content within the 2008 SDPWS. Copyright © 2013 American Wood Council 3 www.awc.org Outline Lateral load basics Code acceptance of Standard 2005/2008 Wind & Seismic Standard Overview 2008 Wind & Seismic Standard Frequently Asked Questions Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 4 www.awc.org Load Path Wind Seismic (Earthquake) Motion IBC Section 1604.4 requires complete load path Point of origin Resisting element Image courtesy APA – The Engineered Wood Association 2003 Copyright © 2013 American Wood Council 5 www.awc.org Lateral Loads Wind Load Path Diaphragm SUPPORTS out‐of‐ plane walls In‐plane walls SUPPORT diaphragm Windward wall Leeward wall Image courtesy APA – The Engineered Wood Association 2003 Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 6 www.awc.org Building Response Motions Horizontal force transfer in‐plane shear Reaction Vmax at edges diaphragm Diaphragm load, w Reaction shear wall Copyright © 2013 American Wood Council 7 www.awc.org Building Response Motions torsion mass center stiffness center mass center stiffness center Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. eccentricity 8 www.awc.org Lateral Structural Elements Shear wall Drag strut (or collector) Vertical plane Diaphragm Horizontal plane Collector beam (or drag strut) Copyright © 2013 American Wood Council 9 www.awc.org Shear Wall ‐ Parts Five parts of a shear wall 2 wood structural panels wood frame 1 3 nails 5 hold downs 4 Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. plate anchors 10 www.awc.org Shear Wall ‐ Types 1. Individual Full‐Height Wall Segments Ignore all but full‐height segments 2. Perforated Shear Walls 3. Force Transfer Shear Walls Moves hold downs to corners With or without force transfer around openings Copyright © 2013 American Wood Council 11 www.awc.org Diaphragm ‐ Types Rigid Diaphragm behaves as a fully rigid body diaphragm < 2shearwalls Inherent and accidental torsion considered in design Flexible Diaphragm behaves as a series of simple beams diaphragm > 2shearwalls No torsion Tributary loading to vertical resisting elements (shear walls) Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 12 www.awc.org Drag Struts and Collectors “collects” diaphragm load and “drags” it back to a shear wall occur most frequently at junction of diaphragm and shear wall Collector beams (floor plane) Drag struts (wall plane) Copyright © 2013 American Wood Council 13 www.awc.org Collector Beam in Floor For “wall continuity” Collector beam Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. Boundary nail (B.N.) diaphragm 14 www.awc.org Drag Strut in Wall Usually the top plate serves as collector and diaphragm chord Might be window or door header Drag strut elements Diaphragm shear Shear wall panel Wall shear Copyright © 2013 American Wood Council 15 www.awc.org Code Acceptance of Standard 2006 IBC Permitted alternative to Section 2305 References 2005 SDPWS 2009 IBC Mandatory References 2008 SDPWS in Section 2305 for lateral design and construction Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 16 General Overview www.awc.org Scope: “The provisions of this document cover materials, design and construction of wood members, fasteners, and assemblies to resist wind and seismic forces.“ ASD and LRFD Copyright © 2013 American Wood Council 17 www.awc.org General Overview Outline Chapter 1: Flowchart Chapter 2: General Design Requirements Chapter 3: Members and Connections Chapter 4: Lateral Force Resisting Systems Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 18 www.awc.org Chapter 1 – Designer Flowchart Copyright © 2013 American Wood Council 19 www.awc.org Chapter 2 – General Requirements General Terminology Notation Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 20 www.awc.org Chapter 2 – Design Methodologies Copyright © 2013 American Wood Council 21 www.awc.org Chapter 3 ‐ Members and Connections Framing Sheathing Connections Covers out‐of‐plane wind load resistance of shear walls and diaphragms Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 22 www.awc.org Chapter 3 ‐ Members and Connections Framing – walls Accounts for composite action Extension of 1.15 repetitive member factor, Cr Copyright © 2013 American Wood Council 23 www.awc.org Chapter 3 ‐ Members and Connections Sheathing ‐ walls Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 24 www.awc.org Chapter 3 ‐ Members and Connections Sheathing – roof Copyright © 2013 American Wood Council 25 www.awc.org Chapter 4 ‐ Lateral Force‐Resisting Systems General Wood Diaphragms Wood Shear Walls Covers in‐plane wind and seismic load resistance of shear walls and diaphragms Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 26 www.awc.org Chapter 4 ‐ Lateral Force‐Resisting Systems Wood Diaphragms Copyright © 2013 American Wood Council 27 www.awc.org Chapter 4 ‐ Lateral Force‐Resisting Systems Wood Diaphragms Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 28 www.awc.org Chapter 4 ‐ Lateral Force‐Resisting Systems • Wood Diaphragms • • Deflection example 2008 SDPWS Commentary Copyright © 2013 American Wood Council 29 www.awc.org Chapter 4 – Design Value Format Nominal design values tabulated for diaphragms: ASD reduction factor (2.0) LRFD resistance factor (0.80) Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 30 www.awc.org Chapter 4 ‐ Lateral Force‐Resisting Systems Wood Diaphragms Copyright © 2013 American Wood Council 31 www.awc.org Chapter 4 – Nominal Design Value Wind nominal unit shear capacity vw IBC allowable stress design value x 2.8 Seismic nominal unit shear capacity vs vs = vw / 1.4 Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 32 www.awc.org Chapter 4 ‐ Lateral Force‐Resisting Systems Wood Shear Walls Copyright © 2013 American Wood Council 33 www.awc.org Chapter 4 – Design Value Format Nominal design values tabulated for shear walls: ASD reduction factor (2.0) LRFD resistance factor (0.80) Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 34 www.awc.org Chapter 4 ‐ Lateral Force‐Resisting Systems Wood Perforated Shear Walls Copyright © 2013 American Wood Council 35 www.awc.org Chapter 4 ‐ Lateral Force‐Resisting Systems Adhesive Attachment of Shear Wall Sheathing SDPWS 4.3.6.3.1 Exception… Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 36 www.awc.org Chapter 4 ‐ Lateral Force‐Resisting Systems Wood Shear Walls 2:1 unless va = 2(bs/h) 2:1 3:1 3½:1 1.00 0.67 0.57 Copyright © 2013 American Wood Council 37 www.awc.org Chapter 4 ‐ Lateral Force‐Resisting Systems Panel Widths for Shear Walls 4.3.7.1…Panels shall not be less than 4′×8′, except at boundaries and changes in framing where 24″ is allowed unless framing members or blocking is provided at the edges of all panels. Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 38 www.awc.org Chapter 4 – Nominal Design Value Wind nominal unit shear capacity vw IBC allowable stress design value x 2.8 Seismic nominal unit shear capacity vs vs = vw / 1.4 Copyright © 2013 American Wood Council 39 www.awc.org Chapter 4 – Nominal Unit Shear Capacities ASD Reduction factor = 2.0 Wind Seismic = 0.8 LRFD vw / 2.0 vs / 2.0 Wind Seismic vw x 0.8 vs x 0.8 = vw x 0.8 / 1.4 = vw x 0.57 LRFD has up to 12% strength benefit for seismic design for shear when using the following IBC load factors: LRFD: 1.0E or 1.6W ASD: 0.7E or 1.0W Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 40 www.awc.org Chapter 4 ‐ Lateral Force‐Resisting Systems Summing Shear Capacities 4.3.3.2 Summing Shear Capacities… For shear walls sheathed with dissimilar materials on opposite sides, the combined nominal unit shear capacity, (νsc) or (νwc), shall be either two times the smaller nominal unit shear capacity or the larger nominal unit shear capacity, whichever is greater. Copyright © 2013 American Wood Council 41 www.awc.org Appendix A Nominal Shear Capacity Tables Wood‐Frame Plywood Blocked Wood Structural Panel Diaphragms Wood‐Frame Plywood Unblocked Wood Structural Panel Diaphragms Wood‐Frame Plywood Shear Walls Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 42 www.awc.org 2008 Wind & Seismic Standard Top Ten Changes! 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. High load diaphragms WSP ‐ combined uplift and shear Unblocked shear walls Shear wall anchorage provisions - 3x square WSP over gypsum shear walls Shear walls sheathed on 2 sides Fiberboard shear wall aspect ratio adjustment Increased strength limit for PSW PSW shear strength equation Appendix: Standard Nail Sizes and Cut Washers Copyright © 2013 American Wood Council 43 www.awc.org High Load Diaphragms (4.2.7.1.2) Consistent with IBC 2006 Includes apparent shear stiffness (Ga) Table 4.2B Nominal Unit Shear Capacities for Blocked Wood-Frame Diaphragms Utilizing Multiple Rows of Fasteners (High Load Diaphragms) Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 44 www.awc.org High Load Diaphragms 4.2.7.1.2 rules for building them Need 3" or greater nominal members Copyright © 2013 American Wood Council 45 www.awc.org High Load Diaphragms Boundary and panel edge nailing details Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 46 www.awc.org Combined Wind Uplift & Shear ‐ WSP Wood structural panels (WSP) Resist combined wind uplift and shear Resist tension only from wind uplift Alternate to metal straps Copyright © 2013 American Wood Council 47 www.awc.org Combined Wind Uplift & Shear ‐ WSP Table 4.4.1 Shear & Uplift amount of available uplift capacity beyond shear capacity Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 48 www.awc.org Combined Wind Uplift & Shear ‐ WSP Minimum panel thickness = 7/16“ Vertical sheathing Minimum spacing of fasteners in a row = 3“ Horizontal blocking All shear wall types Individual full‐height Perforated Force‐transfer Photo: APA Copyright © 2013 American Wood Council 49 www.awc.org Combined Wind Uplift & Shear ‐ WSP Critical details Note minimum edge distance is 1/2" Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 50 www.awc.org Combined Wind Uplift & Shear ‐ WSP Sheathing tension splice vs. shear blocking (for shear) (deals with tension perp) Copyright © 2013 American Wood Council 51 www.awc.org Combined Wind Uplift & Shear ‐ WSP Sheathing Splices per 4.4.1.7 Number of Stories No Horizontal Sheathing Joint over Studs Horizontal Sheathing Joint over Studs Sheathing Tension Splice over Studs One‐Story No splice required •Blocking to resist Resists both shear shear (4.4.1.3) and uplift •Stud nailing to resist (4.4.1.7 Exception) uplift (4.4.1.7(2)) Multi‐Story Nail spacing at common horizontal framing > 3″ single row or > 6″ double row (4.4.1.7 (1) and Fig. 4H) •Blocking to resist Resists both shear shear (4.4.1.3) and uplift •Stud nailing to resist (4.4.1.7 Exception) uplift (4.4.1.7(2)) Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 52 www.awc.org Combined Wind Uplift & Shear ‐ WSP Multi‐story – sheets splice at band joist Nail spacing limited to address tension perp Combined Uplift Shear 6″ o.c. minimum 3″ o.c. minimum Copyright © 2013 American Wood Council 53 www.awc.org Combined Wind Uplift & Shear ‐ WSP Multi‐story – sheets splice at stud mid‐height Combined Uplift Shear Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 54 www.awc.org Combined Wind Uplift & Shear ‐ WSP Example: Splice over studs 110 MPH Exposure B Uplift to resist: 277 plf • Use (2.0 x 277 = 554 plf) and Table 4.4.1 below Copyright © 2013 American Wood Council 55 www.awc.org Combined Wind Uplift & Shear ‐ WSP Example: Splice over studs Uplift too high to allow multi‐story splice to occur over band joist, so design splice over studs Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 56 www.awc.org Combined Wind Uplift & Shear ‐ WSP Example: Splice over studs Double row 8d nails @ 4″ o.c. 4 x 12 4x8 Copyright © 2013 American Wood Council 57 www.awc.org Combined Wind Uplift & Shear ‐ WSP Example: Splice over studs Single row 8d nails @ 4″ o.c. See 4.4.1.7 (1) 4 x 12 4x8 Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 58 www.awc.org Combined Wind Uplift & Shear ‐ WSP Example: Splice over studs Additional nails (n) required above and below joint studs to resist uplift capacity (4.4.1.7(2)): in For 8d @ 4” & 12” ASD Capacity = 324 plf > 277 plf OK n = [324 x 16/12]/Z x C_D = [324 x 16/12]/[67 x 1.6] 4 x 12 = 4.03 use 4 nails per stud 4x8 Copyright © 2013 American Wood Council 59 www.awc.org Combined Wind Uplift & Shear ‐ WSP Example: Splice over studs Check field nailing requirements for stud supporting 4 x 12 panel below the rim joist: Min. stud length on 4 x 12 panel below rim = 31.875” #nails/stud = 31.875”/12” + 1 = 3.65 nails = 4 nails Total # nails required/stud = 4 + 4 = 8 nails Spacing: 31.875”/(8‐1) = 4.55” 4 x 12 Specify 4” o.c. in field 4x8 Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 60 www.awc.org Combined Wind Uplift & Shear ‐ WSP Uplift only case Single or double row of fasteners Tension not shear Test verified Copyright © 2013 American Wood Council 61 www.awc.org Combined Wind Uplift & Shear ‐ WSP Default anchorage (4.4.1.6) Anchor bolts at 16" o.c. with 3" x 3" x 0.229" steel plate washer Plate washer within ½" of sheathing face that provides uplift Resist cross grain bending of bottom plate Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 62 www.awc.org Shear Wall Anchorage – 3" x 3" Default New shear wall anchorage provisions at foundation – Section 4.3.6.4.3 3" x 3" x 0.229" steel slotted hole permitted placed within ½" of sheathing material automatically satisfied for 2x4 plate Copyright © 2013 American Wood Council 63 www.awc.org Shear Wall Anchorage – 3" x 3" Default New shear wall anchorage provisions at foundation– Section 4.3.6.4.3 Exception: round washers permitted • provided hold down appropriately sized for overturning • Only applies to Individual Full‐ Height Wall Segments • Limited shear wall capacities Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 64 www.awc.org Unblocked Shear Walls Nails 6" panel edge spacing Up to 2:1 aspect ratio 16' height limit Based on cyclic testing Shear capacity reduction Copyright © 2013 American Wood Council 65 www.awc.org Unblocked Shear Walls Deflection (4.3.2.2) Less stiffness Deflection component amplified by: v Cub Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 66 www.awc.org WSP over Gypsum Shear Walls Section 4.3.7.2 and Table 4.3B Consistent with IBC 2006 Shear wall with fire resistance Copyright © 2013 American Wood Council 67 www.awc.org WSP over Gypsum Shear Walls Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 68 www.awc.org Shear Walls Sheathed on 2 Sides IBC 2006 provisions for shear walls sheathed on two sides ‐ Table 4.3A Footnote 6 6. Where panels are applied on both faces of a shear wall and nail spacing is less than 6" on center on either side, panel joints shall be offset to fall on different framing members. Alternatively, the width of the nailed face of framing members shall be 3" nominal or greater at adjoining panel edges and nails at all panel edges shall be staggered. Copyright © 2013 American Wood Council 69 www.awc.org Shear Walls Sheathed on 2 Sides Adjoining Panel Edge Details Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 70 www.awc.org Structural Fiberboard Shear Walls Aspect ratio adjustment for structural fiberboard shear walls Table 4.3.4 Footnote 3 Now permitted up to 3.5:1 based on cyclic testing • used to be 1.5:1 Copyright © 2013 American Wood Council 71 www.awc.org Structural Fiberboard Shear Walls Aspect ratio adjustment If < 1:1 reduce design unit shear Wind factor tied to strength • at 3.5:1 wind factor = 0.78 Seismic factor tied to equivalent stiffness for same seismic drift level • at 3.5:1 seismic factor = 0.36 - Structural Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 72 www.awc.org Structural Fiberboard Shear Walls Structural fiberboard shear walls – Table 4.3A Nail size recommendation • 8d common is dropped 4.3.7.4 increased minimum distance from panel edge at top and bottom plates to 3/4" Copyright © 2013 American Wood Council 73 www.awc.org PSW Increased Strength Limit Increased strength limit for perforated shear walls ‐ Section 4.3.5.3 (3) 1740 plf nominal seismic shear capacity (980 plf nominal in 2005 SDPWS) 2435 plf nominal wind shear capacity (1370 plf nominal in 2005 SDPWS) Tests with10d nails @ 2" o.c. edge Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 74 www.awc.org PSW Shear Strength Equation Copyright © 2013 American Wood Council 75 www.awc.org PSW Shear Strength Equation Section 4.3.3.5 Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 76 www.awc.org PSW Shear Strength Equation Alternative to tabulated values – Section 4.3.3.5 Allows more efficient designs • Actual area of openings Table requires maximum opening size • Example: 1 door & 2 windows • Table assumes windows are same height as door • Takes away panel shear area Table Copyright © 2013 American Wood Council 77 www.awc.org Standard Nails and Cut Washers Appendix A Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 78 www.awc.org Wind & Seismic Standards More details on changes Wood Design Focus papers 2005 Special Design Provisions for Wind and Seismic (SDPWS) 2008 Special Design Provisions for Wind and Seismic Use of Wood Structural Panels to Resist Combined Shear and Uplift from Wind Download free at www.awc.org Copyright © 2013 American Wood Council 79 www.awc.org Frequently Asked Questions Q: What about pneumatic nails or staples? A: Design capacities are provided in a National Evaluation Report held by International Staple and Nail Tool Association: www.isanta.org Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 80 www.awc.org Questions? www.awc.org Online eCourses FAQ’s Calculators Copyright © 2013 American Wood Council Copyright © 2013 American Wood Council. All rights reserved. 81