Energy Efficiency Programs Worldwide – 01/2015 Rev: 08

advertisement
Energy Efficiency
Programs Worldwide
Rev: 08 – 01/2015
Worldwide Standards Overview
Why is important to know and understand local efficiency regulations?
 Understand OEMs and end customers needs;
 Be a technical reference about efficiency regulations and get
customer’s trustworthy by giving correct support;
 Avoid non compliance efficiency level on the end of the sales process;
 Find the optimal point between stock volume and motor flexibility;
 Be aware and ready to react during shifting of efficiency levels having
the right motors in stock and avoiding stock of outdated motors.
Main Standards Worldwide
NEMA
IEC
ABNT
AS/NZS
Frequency Worldwide
50Hz
60Hz
Green Rate / Efficiency Regulations
IEC
NEMA
AS/NZS
ABNT
China
IE1
IE2
IE3
IE4
Standard
High
Premium
Super Prem.
E1
E2
E3
E3+
Padrão
Alto Rend.
Alto R. Plus
Grade 3
Grade 2
Grade 1
Minimum Efficiency - IEC
IE1
IE2
IE3
China now follow
IE2 efficiency
values (GR3=IE2)
Europe since Jan 2015 (7.5 to 375kW)
and shifting in 2017 (0.75 to 5.5kW)
Minimum Efficiency - NEMA
Std
High
Premium
ME market is basically
IEC, but NEMA is
required for some
projects (oil & gas)
Mandatory at North America
Minimum Efficiency - ABNT
60Hz countries in Latin
America also accept
ABNT motors
Alto Rend.
Mandatory
Minimum Efficiency - AS/NZS
E2
E3
Mandatory
Market buys E3
Labeling Europe Union
IE3 Efficiency Level (7.5 up to 375kW)
Requirements
Applicable to:
Nameplate shall record :

Motors 2, 4 and 6 poles

Efficiency level (IE2/IE3)

Ratings from 0.75 to 375kW

Efficiency values for 50, 75 and 100% load

Frequency: 50, 60 and 50/60Hz

CE mark

Voltage up to 1000V
Not applicable to:

2 speed motors

Integral brake motor

Torque Design D

Dedicated VFD design (not suitable for DOL / up to 2012)

TEAO

Intermittent duty

Ambient temperature out of the range -30 to 60oC

Altitude higher than 4000masl

Hazardous area

Synchronous motors
In 2017 Europe
shifts 0.75 to
5.5kW to IE3
Labeling North America
NEMA Premium Efficiency
Requirements
Applicable to:

Motors 2, 4 and 6 poles

Ratings from 1 to 200HP

Voltage 230 and 460V (EUA & Mexico)

Voltages up to 600V (Canada)

Efficiency level shall be as per NEMA MG1 NEMA Premium

Efficiency level shall be printed on motor nameplate

Motor shall be registered at Department of Energy (DOE)

DOE register number shall be printed on nameplate
(WEG: CC029A)
Not applicable to*:

Dedicated VFD design (not suitable for DOL)

Motors higher than 200HP

Non standard voltages (excluding 230/460V)

Submersible motors (IP68)

Special shaft motors (non T frame) – US only

2 speed motors

Integral brake motor

Torque Design D

TENV and TEAO

Intermittent duty
* All exceptions must meet High Efficiency Level, the only exception for High
Efficiency are the double speed motors.
NEMA PREMIUM
required since
december 2010
Labeling China
GR3 Efficiency Level (GB 18613-2012) *
Requirement Label
Applicable to:

Safe and Hazardous Area

Ratings from 0.75 to 375kW**

Motors 2, 4 and 6 poles

Frequency: 50Hz

Voltage up to 690V / 3ph

Torque design N
Not applicable to:

TENV and TEAO

Increased safety (Exe)

Dedicated VFD design (not suitable for DOL)

Dedicated marine and mining motors

Integrated design with driven machine

Brake motors
* Efficiency values are the same of IEC, GR3 → IE2, GR2
→ IE3, GR1 → IE4
Motors without this label
will not be allowed through
Chinese customs!
GB 18613-2012
Labeling Australia & New Zealand
E2 Efficiency Level
Applicable to:

Motors 2, 4, 6 and 8 poles

Ratings from 0.73 to 185kW

Frequency: 50Hz

Up to 1100V
Requirements

Efficiency level shall be E2 or E3 as per AS/NZS 1359.55

Efficiency level shall be printed on motor nameplate

Motor design shall be registered at following link:
http://reg.energyrating.gov.au/comparator/product_types/
Not applicable to:

2 speed motors

Dedicated VFD design (not suitable for DOL)

Intermittent duty short duty cycles

Integrated design with driven machine
(TEAO not included)

Submersible motors (IP68)
Australia is evaluating a revision at
AS/NZS to follow IEC efficiency
program (to be similar).
It’s not agreed yet!
Market buys E3
Labeling Brazil
Alto Rendimento / Portaria 553
Required Label
Applicable to:

Closed and open enclosures

Motors 2, 4 poles up to 250cv(HP)

Motors 6 poles up to 200cv(HP)

Motors 8 poles up to 180cv(HP)

Frequency: 60Hz (or 50Hz operating in 60Hz)

Voltage up to 1000V

Duty cycle S1 or S3 (ED higher or equal to 80%)

Starting torque as per design N, H, NY or HY (or NEMA equivalent)
Motors without this
label will not be
allowed through
Brazilian customs!
Not applicable to:

Integral brake motor

Dedicated VFD design (not suitable for DOL)

Intermittent duty

Explosion proof (Exd)

Procedure for non approved motors:
Increased safety (Exe)
European electrical design is not
registered on Inmetro!

Check if motor efficiency is meeting ABNT requirements

Ask for an import license from Inmetro prior start export process

Dispatch the motors after receive the authorization from Inmetro

Submit sample motors to the lab for testing (Cepel, IEE/USP, Labelo)

Laboratory will issue a test certificate stating motor performance

After evlauate the test certificate Inmetro releases motors license

More information at www.inmetro.gov.br (Portaria 488)
Labeling South Korea
MEPS South Korea (KEMCO) *
Applicable to:

Closed and open enclosures

Motors 2, 4, 6 and 8 poles

Ratings from 0.75 to 200kW

Voltage up to 600V

Frequency: 60Hz
Not applicable to:

TEAO and TENV

Smoke Extraction

Marine and 2 speed motors

Motors with sleeve or thrust bearings
Not Certified

Hazardous area motors
* Motors Exclusively manufactured at WNT
Required Label
Motors without this label will
not be allowed through
Korean customs!
Labeling Middle East
Efficiency Level

Most of Middle East countries
do not have a minimum
efficiency requirement.

Cyprus, Israel and Turkey are
the exceptions, adopting the
same requirement as Europe
(IEC IE2).

Saudi Arabia is studying also
adopting IEC IE2.
Although IEC is generally
adopted, for some specific
projects NEMA efficiency
levels may be required.
Requirements (only for Cyprus, Israel and Turkey)
Nameplate shall record :

Efficiency level (IE2/IE3)

Efficiency values for 50, 75 and 100% load

CE mark
Download