For the ConTech Lighting LED Puck Accent Lights: PA1, PA3, and PA4 Series The PA1, PA3 and PA4 LED Puck Accent Lights are suitable for recessed/surface mount installation into ceilings, cabinets, furniture, and no-permanent attachments to a building’s structure. Recessed applications: Cut hole in surface for the fixture Surface applications: Mark locations for surface collar mounting. PLUG-AND-PLAY applications: Use PLE2, PLE4, or PLE6. NOTE: If there are any open/empty terminals, use the closed loop plug (PLE-CL) to complete the circuit. PLE2 PLE4 PLE6 PLE-CL For HARDWIRE applications, cut off the plug-and-play connector and separate the red and black wires. The LED Puck Accent Lights need to be wired in series. For example, red wire from fixture 1 wires to the black wire from fixture 2 and the red from fixture 2 wires to the black wire from fixture 3. 1 Red 2 Black Red 3 Black Red Black Once wiring is completed, push fixture into the hole or surface collar. Fixture should be held in by the retention clips. 5 + _ 120VAC INPUT CLASS II LED DRIVER Give the fixture 1/4 turn to secure the fixture into the opening. All specifications subject to change without notice. 1-847-559-5500 www.contechlighting.com This document can be recycled. INST PASERIES For the ConTech Lighting LED Puck Accent Lights: PA1, PA3, and PA4 Series LED DRIVER SELECTION CHART Drivers are 120VAC and 350mA. Each driver needs to be wried in a series as shown in Figure 3. For any further questions, call the Technical Support department at ConTech Lighting: 847.559.5500 LED DRIVER FIXTURE LED3503 LED3512 LED3513 LED3518 LED350-12D1-120* PA1 1-2 1-9 5-10 9-15 2-8 PA3 0 1-3 2-3 3-5 1-3 PA4 0 1-2 2 3 1-2 *LED350-12D1-120 is a Triac dimmable driver WIRING INFORMATION For HARDWIRE application wiring, the recommended wire size is 18awg. From the positive terminal out to each fixture and back to negative terminal should be no further than 60ft. For PLUG-AND-PLAY applications, the chart below shows total included wire lengths on each component. COMPONENT LENGTH PA1 20" PA3 20" PA4 20" PLE2 6.5 FT PLE4 6.5 FT PLE6 6.5 FT IMPORTANT SAFETY INSTRUCTIONS: • Read all the instructions before installation. Save instructions for later use. • Turn off power at fuse or circuit breaker box before installation or before doing any maintenance work. • Product must be grounded to avoid potential electric shock and any other potential hazards. • Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in compliance with National Electrical Code and local codes. Use of accessory equipment is not recommended. • Installing contrary to instructions may cause unsafe conditions. • Do not block light from the trim aperture, in whole or in part, as this may cause unsafe conditions. • Warning: Risk of fire. Most dwellings built before 1985 have supply wire rated at 60°C. Consult a qualified electrician before installation. • Avoid hazards to children: account for all parts and properly dispose of all packing materials. • Call the Technical Support department at ConTech Lighting with any installation questions: 847.559.5500 All specifications subject to change without notice. 1-847-559-5500 www.contechlighting.com This document can be recycled. INST PASERIES