For ConTech Lighting Ceiling Mount Cylinder Fixtures: CM6C, CM8C, CF6C, CF8C, CI6C, CI8C CEILING MOUNT INSTALLATION INSTRUCTIONS Cylinder Lid 1. Detach the cylinder lid from the fixture by twisting the lid counter-clockwise and pull it up. Figure 1. 2. Install the lid to the junction box with included screws. Figure 2. 3. Connect the cylinder wires and the input power wires from the junction box (Black to Black, White to White, Green to Green) with included wire nuts. Figure 2. 4. Attach the cylinder to the lid by twisting the cylinder counter-clockwise until hearing a locking noise. 5. Attach the reflector by aligning the screws next to the socket with the key-hole slots on the reflector. Turn the reflector so that the screws slide over the narrow portion of the key-hole slots. Tighten the screws with a Philips head screwdriver. Figure 3. 6. For baffle assembly, push the baffle into the reflector for a tight fit. 7. Insert the appropriate wattage lamp per the UL relamping label. Turn lid counter-clockwise, pull up to detach IMPORTANT SAFETY INSTRUCTIONS: Read all the instructions before installation. Save the instructions for later use. Turn off the power at the fuse or circuit breaker box before installation or any maintenance work. Wear rubber-soled shoes and work on a sturdy wooden or other nonconductive ladder. Fixtures must be installed according to national electrical code and local building codes. For indoor use only. To avoid a hazard to any children, account for all parts and destroy all packing materials. Do not install any fixtures closer than 6” from any curtain or similar combustible material. Warning: Risk of fire. Most dwellings built before 1985 have supply wire rated at 60°C. Consult a qualified electrican before installation. Call the Technical Support department at ConTech Lighting if you have any installation questions. 800.728.0312 Install Cylinder lid to junction box Safety Chain Connect cylinder wires to power supply wires Keyhole Slots Philips Head Screws Socket View of Socket 1-800-728-0312 www.contechlighting.com All specifications subject to change without notice. CM_INST