Proceedings of MNHMT2009 ASME 2009 2nd Micro/Nanoscale Heat & Mass Transfer International Conference December 18-22, 2009, Shanghai, China MNHMT2009-18118 UNSTEADY HEAT TRANSFER AND PHASE CHANGING PROCESS WITHIN SMALL ICING WATER DROPLETS Hui HU 1 and Zheyan JIN 2 1 2 Department of Aerospace Engineering, Iowa State University, Ames, Iowa 50011, USA. School of Aerospace Engineering & Applied Mechanics, Tongji University, Shanghai, 200092, China. ABSTRACT We report progress made in our recent effort to develop and implement a novel, lifetime-based molecular tagging thermometry (MTT) technique to quantify unsteady heat transfer and phase changing process inside small icing water droplets pertinent to wind turbine icing phenomena. The lifetime-based MTT technique was used to achieve temporallyand-spatially resolved temperature distribution measurements within small, convectively-cooled water droplets to quantify unsteady heat transfer within the small water droplets in the course of convective cooling process. The transient behavior of phase changing process within small icing water droplets was also revealed clearly by using the lifetime-based MTT technique. Such measurements are highly desirable to elucidate underlying physics to improve our understanding about important micro-physical phenomena pertinent to ice formation and accreting process as water droplets impinging onto wind turbine in cold atmospheric environment. Keywords: Molecular Tagging Thermometry, Micro Scale Heat Transfer, Water Droplets, Multiphase Flow, Wind Turbine Icing INTRODUCTION Wind energy is one of the cleanest renewable power sources in the world today. U.S. Department of Energy has challenged the nation to produce 20% of its total power from wind by 2030. It has been found that the majority of wind energy potential available in U.S. is in the northern states such as North Dakota, Kansas, South Dakota, Montana, Nebraska, Wyoming, Minnesota, and Iowa, where wind turbines are subjected to the problems caused by cold climate conditions. Wind turbine icing represents the most significant threat to the integrity of wind turbines in cold weather. It has been found that wind turbine icing would cause a variety of problems to the safe and efficient operations of wind turbines. Ice accretion on turbine blades was found to reduce the aerodynamic efficiency of wind turbines considerably, which results in wind turbine power production reduction. It has also been found that the operation of a wind turbine with an imbalance caused by ice accretion would experience an increase in the loads imposed on all turbine components, which would shorten the lifetime for wind turbine components. Uncontrolled shedding of large ice chunks from turbine blades was also found to be of special danger to service personnel as well as nearby residents, particularly when the wind power plant site borders public roads, housing, power lines, and shipping routes. In addition, Icing was found to affect tower structures by increasing stresses, due to increased loads from ice accretion. This would lead to structural failures, especially when coupled to strong wind loads. Ice accretion was also found to affect the reliability of anemometers, thereby, leading to inaccurate wind speed measurements and resulting in resource estimation errors. Advancing the technology for safe and efficient wind turbine operation in atmospheric icing conditions requires a better understanding of the important micro-physical processes pertinent to wind turbine icing phenomena. In order to elucidate underlying physics, advanced experimental techniques capable of providing accurate measurements to quantify important ice formation and accreting process, such as 1 Copyright © 2009 by ASME the unsteady heat transfer and phase changing processes inside small icing water droplets, are highly desirable. In the present study, we report progress made in our recent effort to develop and implement a novel, lifetime-based molecular tagging thermometry (MTT) technique to quantify the unsteady heat transfer and phase changing process within small icing water droplets in order to improve our understanding about the underlying physics pertinent to wind turbine icing phenomena for the development of effective and robust anti-/de-icing strategies tailored for wind turbine icing mitigation. Lifetime-based MTT technique used in the present study can be considered as an extension of the Molecular Tagging Velocimetry and Thermometry (MTV&T) technique developed by Hu & Koochesfahani [1]. In the sections that follow, the technical basis of the lifetime-based MTT will be described briefly along with the related properties of the phosphorescent tracer used for the MTT measurements. The application of the lifetime-based MTT technique to quantify the unsteady heat transfer and phase changing process will be given to elucidate underlying physics to improve our understanding about important micro-physical phenomena pertinent to ice formation and accreting process as water droplets impinging on wind turbine blades in cold weather. LIFETIME-BASED MTT TECHNIQUE It is well known that both fluorescence and phosphorescence are molecular photoluminescence phenomena. Compared with fluorescence, which typically has a lifetime on the of order nanoseconds, phosphorescence can last as long as microseconds, even minutes. Since emission intensity is a function of the temperature for some substances, both fluorescence and phosphorescence of tracer molecules may be used for temperature measurements. Laser-induced fluorescence (LIF) techniques have been widely used for temperature measurements of liquid droplets for combustion applications [2, 3]. Laser-induced phosphorescence (LIP) techniques have also been suggested recently to conduct temperature measurements of “in-flight” or levitated liquid droplets [4, 5]. Compared with LIF techniques, the relatively long lifetime of LIP could be used to prevent interference from scattered/reflected light and any fluorescence from other substances (such as from solid surfaces) that are present in the measurement area, by simply putting a small time delay between the laser excitation pulse and the starting time for phosphorescence image acquisitions. Furthermore, LIP was found to be much more sensitive to temperature variation compared with LIF [2-6], which is favorable for the accurate measurements of small temperature differences within small liquid droplets. The lifetime-based MTT technique used in the present study is a LIP-based technique. According to quantum theory [7], the intensity of a firstorder photoluminescence process (either fluorescence or phosphorescence) decays exponentially. As described in reference 1 , for a diluted solution and unsaturated laser excitation, the collected phosphorescence signal (S) by using a gated imaging detector with integration starting at a delay time to after the laser pulse and a gate period of δt can be given by ( S = AI i Cε Φ p 1 − e −δ t / τ )e −to / τ (1) where A is a parameter representing the detection collection efficiency, Ii is the local incident laser intensity, C is the concentration of the phosphorescent dye (the tagged molecular tracer), ε is the absorption coefficient, and Φp is the phosphorescence quantum efficiency. The emission lifetime τ refers to the time at which the intensity drops to 37% (i.e. 1/e) of the initial intensity. For an excited state, the deactivation process may involve both radiative and non-radiactive pathways. The lifetime of the photoluminescence process, τ, is determined by the sum of all the deactivation rates: τ −1 = k r + k nr , where kr and knr are the radiative and non-radiative rate constants, respectively. According to photoluminescence kinetics [7], these rate constants are, in general, temperature-dependant. The temperature dependence of the phosphorescence lifetime is the basis of the present lifetime-based MTT technique. It should be noted that the absorption coefficient, ε , and quantum yield, Φp, are also temperature dependent in general in addition to phosphorescence lifetime,τ, resulting in a temperature-dependent phosphorescence signal (S). Thus, in principle, the collected phosphorescence signal (S) may be used to measure fluid temperature if the incident laser intensity and the concentration of the phosphorescent dye remain constant (or are known) in the region of interest. It should be noted that the collected phosphorescence signal (S) is also the function of incident laser intensity (Ii) and the concentration of the phosphorescent dye (C). Therefore, the spatial and temporal variations of the incident laser intensity and the non-uniformity of the phosphorescent dye (e.g. due to photobleaching) in the region of interest would have to be corrected separately in order to derive quantitative temperature data from the acquired phosphorescence images. In practice, however, it is very difficult, if not impossible, to ensure a non-varying incident laser intensity distribution, especially for unsteady thermal phenomena with a varying index of refraction. This may cause significant error in the temperature measurements. To overcome this problem, a lifetime-based thermometry 8 was developed to eliminate the effects of incident laser intensity and concentration of phosphorescent dye on temperature measurements. The lifetime-based thermometry works as follows: As illustrated in Fig. 1, laser-induced phosphorescence emission is interrogated at two successive times after the same laser excitation pulse. The first image is detected at the time t = t o after laser excitation for a gate period δ t to accumulate the phosphorescence intensity S1 , while the second image is detected at the time t = t o + Δt for the same gate period to accumulate the phosphorescence intensity S 2 . 2 It is easily Copyright © 2009 by ASME R = S 2 / S1 = e − Δt / τ (2) . In other words, the intensity ratio of the two successive phosphorescence images (R) is only a funtion of the phosphorescence lifetime τ, and the time delay Δt between the image pair, which is a controllable parameter. This ratiometric approach eliminates the effects of any temporal and spatial variations in the incident laser intensity and non-uniformity of the dye concentration (e.g. due to bleaching). For a given molecular tracer and fixed Δt value, Equation (2) defines a unique relation between phosphorescence intensity ratio (R) and fluid temperature T, which can be used for thermometry. degree Celsius [6]. It is noted that, since low concentration of the phosphorescent triplex 1-BrNp⋅Mβ-CD⋅ROH (on the order of 10-4 M) was used for the present study, the effects of the molecular tracers on the physical properties of water were believed to be negligible. During the experiments, the energy level of the pulse laser used to tag the molecular tracers within small water droplets was below 1.0 mJ/pulse. The repetition rate of the pulsed excitation was 2 Hz. The energy deposited by the excitation laser into the small water droplet was believed to be very small. 7 Phosphorescence Lifetime (ms) shown [1, 8], using Equation (1), that the ratio of these two phosphorescence signals (R) is given by: Curve fit Experimental data 6 5 4 3 2 1 0 0 5 10 15 20 25 30 35 40 45 50 o Temperature ( C) Fig. 2: Phosphorescence lifetime vs. temperature. EXPERIMENTAL SETUP Fig. 1: Timing chart of lifetime-based MTT technique The phosphorescent molecular tracer used for the present study is phosphorescent triplex (1-BrNp⋅Mβ-CD⋅ROH). The phosphorescent triplex (1-BrNp⋅Mβ-CD⋅ROH) is actually the mixture compound of three different chemicals, which are lumophore (indicated collectively by 1-BrNp), maltosyl-βcyclodextrin (indicated collectively by Mβ-CD) and alcohols (indicated collectively by ROH). Further information about the chemical and photoluminescence properties of the phosphorescent triplex (1-BrNp⋅Mβ-CD⋅ROH) is available at reference 9 and 10. Upon the pulsed excitation of a UV laser (quadrupled wavelength of Nd:YAG laser at 266nm for the present study), the phosphorescence lifetime of the phosphorescent triplex (1-BrNp⋅Mβ-CD⋅ROH) molecules in an aqueous solution change significantly with temperature. Fig. 2 shows the measured phosphorescence lifetimes of 1-BrNp⋅MβCD⋅ROH molecules as a function of temperature. It can be seen clearly that phosphorescence lifetime of 1-BrNp⋅Mβ-CD⋅ROH molecules varies significantly with increasing temperature, decreasing from about 7.2 ms to 2.5 ms as the temperature changes from 1.0oC to 30.0oC. The relative temperature sensitivity of the phosphorescence lifetime is about 3.5% per degree Celsius, which is much higher than those of fluorescent dyes [3, 5, 6]. For comparison, the temperature sensitivity of Rhodamine B for LIF measurements is less than 2.0% per Figure 3 shows the schematic of the experimental setup used to implement the lifetime-based MTT technique to quantify unsteady heat transfer and phase changing process within small icing water droplets. A syringe was used to generate micro-sized water droplets (about 400μm in radius and 250μm in height) to impinge on a test plate to simulate the processes of small water droplets impinging onto a wind turbine blade. The temperature of the test plate, which was monitored by using a thermocouple, was kept constant at a preselected low temperature level by using a Water Bath Circulator (Neslab RTE-211). The small water droplets with initial temperature of 20.5 oC (room temperature) would be convectively cooled after they impinged onto the cold test plate. Phase changing process would occur inside the small water droplets when the temperature of the test plate was below frozen. A laser sheet (~200μm in thickness) from a pulsed Nd:YAG at a quadrupled wavelength of 266 nm was used to tag the premixed 1-BrNp⋅Mβ-CD⋅ROH molecules along the middle plane of the small water droplets. A 12-bit gated intensified CCD camera (PCO DiCam-Pro, Cooke Corporation) with a fast decay phosphor (P46) was used to capture the phosphorescence emission. A 10X microscopic objective (Mitsutoyo infinity-corrected, NA= 0.28, depth of field = 3.5μm) was mounted in the front of the camera. The camera was operated in the dual-frame mode, where two full frame images of phosphorescence were acquired in a quick succession after the same laser excitation pulse. The camera and the 3 Copyright © 2009 by ASME pulsed Nd:YAG lasers were connected to a workstation via a digital delay generator (BNC 555 Digital Delay-Pulse Generator), which controlled the timing of the laser illumination and the image acquisition. Further details about the experimental setup and procedures to implement the lifetimebased MTT technique to quantify unsteady heat transfer and phase changing process within small icing water droplets are available at reference 11. Fig. 3: Experimental Setup MEASUREMENT RESULTS AND DISCUSSIONS Figure 4 shows a typical pair of acquired phosphorescence images for MTT measurements and the instantaneous temperature distribution inside the water droplet derived from the phosphorescence image pair. The image pair was taken at 5.0s later after the water droplet (initial temperature 20.5 oC) impinged on the cold test plate (Tw =5.0 oC). The first image (Fig. 4a) was acquired at 0.5 ms after the laser excitation pulse and the second image (Fig. 4b) at 3.5 ms after the same laser pulse with the same exposure time of 1.5 ms for the two image acquisitions. Since the time delays between the laser excitation pulse and the phosphorescence image acquisitions can Test Plate, Tw = 5.0OC a). The 1st phosphorescence image eliminate scattered/reflected light and any fluorescence from other substances (such as from solid surface) in the measurement region effectively, the phosphorescence images of the water droplet are quite “clean” even though no optical filter was used for the phosphorescence image acquisition. As described above, Equation (2) can be used to calculate the phosphorescence lifetime of the tagged molecules on a pixel-by-pixel basis, which resulting in a distribution of the phosphorescence lifetime over a two-dimensional domain. With the calibration profile of phosphorescence lifetime vs. temperature as shown in Fig. 2, a two-dimensional, instantaneous temperature distribution within the water droplet can be derived from the phosphorescence image pair, which was shown in Fig. 4c. Based on a time sequence of the measured transient temperature distributions within the water droplet as the one shown at here, the unsteady heat transfer process within the convectively-cooled water droplets was revealed quantitatively. Fig. 5 shows the spatially-averaged temperature of the water droplet as a function of the time after it impinged on the cold test plate, which was calculated based on the time sequence of measured instantaneous temperature distributions. The characteristics of the unsteady heat transfer within the water droplet in the course of convectively cooling process were revealed quantitatively from the evolution of the spatially-averaged temperature of the water droplet. Since initial temperature of the water droplet (20.5 oC) was significantly higher than that of the cold test plate (TW = 5.0 o C), the temperature of the water droplet was found to decrease rapidly after it impinged on the test plate. The measurement results given in Fig. 5 also revealed that a thermal steady state would be reached at about 20 seconds later after the water droplet impinged on the cold test plate. The spatially-averaged temperature of the water droplet would not decrease anymore when the thermal steady state was reached. It should be noted that, based on the uncertainty analysis of MTT measurements given in reference 1, the measurement uncertainty for the temperature data given in the present study was estimated to be within 0.5 oC. Test Plate, Tw = 5.0OC b). The 2nd phosphorescence image c). Corresponding MTT results Fig. 4: A typical MTT measurement When the temperature of the test plate was adjusted to below frozen temperature, water droplets on the test plate was found to be frozen and turn to ice crystals. Fig. 6(a) shows the time sequence of the acquired phosphorescence images of a water droplet when it impinged onto the test plate below frozen temperature (TW = -2.0°C). Fig. 6(b) shows the corresponding instantaneous temperature distributions of the remaining liquid water within the icing droplet measured by using the lifetimebased MTT technique. The transient behavior of the phase 4 Copyright © 2009 by ASME changing process within the small icing water droplet was revealed clearly from the acquired phosphorescence images and the MTT measurement results. In the phosphorescence images, the “brighter” region in the upper portion of the droplet represents liquid phase - water; while the “darker” region at the bottom indicates solid phase - ice. It can be seen clearly that the liquid water at the bottom of the droplet was found to be frozen and turned to solid ice rapidly since the wall temperature of the test plate was below frozen temperature, while the upper portion of the droplet was still in liquid state. As the time goes by, the interface between the liquid phase water and solid phase ice was found to rise upward continuously, as it is expected. As a result, the droplet was found to grow upward with more and more liquid phase water turning into solid phase ice. At about 35 seconds later after the droplet impinged onto the cold test plate, the droplet was found to turn to a solid ice crystal completely. t = 0.5 s 20 O Temperature ( C) 12 8 4 0 0 5 15 20 25 30 35 40 Time (s) t = 20.0 s Test Plate, Tw = -2.0OC t = 35.0 s Liquid water Solid ice Test Plate, Tw = -2.0OC 10 Fig. 5: Spatially-averaged temperature vs. time t = 5.0 s ~250μm Curve fit Experimental data 16 Test Plate, Tw = -2.0OC Test Plate, Tw = -2.0OC (a). Phosphorescence images t = 0.5 s 200 0 400 t = 5.0 s 200 0 O -200 0 X (μm) 200 -400 400 200 0 -200 0 X (μm) 200 0.0 3.0 6.0 9.0 12.0 15.0 18.0 21.0 24.0 t = 35.0 s 200 0 O Test Plate (TW=-2.0 C) 400 Temperature O ( C) 0.0 3.0 6.0 9.0 12.0 15.0 18.0 21.0 24.0 t = 20.0 s O Test Plate (TW=-2.0 C) -400 Temperature O ( C) 0.0 3.0 6.0 9.0 12.0 15.0 18.0 21.0 24.0 Y (μm) 400 Y (μm) Y (μm) Temperature O ( C) 0.0 3.0 6.0 9.0 12.0 15.0 18.0 21.0 24.0 Y (μm) Temperature O ( C) 400 O Test Plate (TW=-2.0 C) 400 -400 -200 0 X (μm) 200 Test Plate (TW=-2.0 C) 400 -400 -200 (b). MTT measurement results Fig. 6: Time evolution of the phase changing process within a small icing water droplet Based on the time sequences of the instantaneous MTT measurements results as those shown in Fig. 6, the averaged temperature of the remaining liquid water within the icing droplet in the course of icing process can be determined. Fig. 7 should the measured profile of the spatially-averaged temperature of the remaining liquid water within the icing droplet in the course of the icing process. As described above, the initial temperature of the liquid water droplet before it impinged onto the cold test plate (TW = -2.0°C) was 20.5 oC. It should be noted that, since the frame rate for the phosphorescence image acquisition used in the present study is relative low, (i.e., f = 2Hz), the rapid temperature deceasing of the water droplet at the moment as it impinged onto the frozen test plate was not be able to be captured due to the limited 0 X (μm) 200 400 temporal resolution of the present MTT measurements. As shown in Fig. 5, it is expected that the temperature of the water droplet would decrease with the time after it impinged onto the cold test plate if the temperature of the cold test plate is above frozen (i.e., there is not phase change involved). Surprisingly, the measurement data for the icing droplet given in Fig. 7 reveal a completely different trend. The averaged temperature of the remaining liquid water within the icing droplet was found to increase monotonically with time in the course of icing process. The increasing temperature of the remaining liquid water in the icing droplet is believed to be closely related to the releasing of the latent heat of solidification in the course of the icing process. 5 Copyright © 2009 by ASME 20 16 12 measurement data Curve fit 8 4 0 0 5 10 15 20 25 30 35 Time (s) Fig. 7: The averaged temperature of the liquid water in the icing droplet vs. time As visualized clearly from the MTT measurement results given in Fig. 7, the liquid water at the bottom of the icing droplet would turn to solid ice rapidly after the droplet impinged onto the frozen test plate. It is well known that there will be a significant amount of latent heat of solidification being released as liquid water turning into solid ice. According to reference 12, the specific latent heat of solidification for water is 334 KJ/Kg. While the majority of the released latent heat of solidification would be conducted through the cold test plate and dissipated by the thermal bath circulator, a portion of the latent heat of solidification would be conducted through the interface between the solid ice and the liquid water within the icing droplet, which would heat the remaining liquid water. In the course of icing process, more and more liquid water would turn to ice with the latent heat of solidification released continuously as the time goes by, while the total amount of the remaining liquid water within the icing droplet became less and less. As a result, the averaged temperature of the remaining liquid water within the icing droplet would increase monotonically with time until the droplet was found to turn to ice crystal completely at about 35 seconds later after it impinged onto the frozen cold test plate. The variations of the droplet shape profiles given in Fig. 8 also reveal clearly that the volume of the droplet would be expended continuously in the course of the icing process. As described above, since the laser illuminating plane is along the middle plane of the droplet for the MTT measurements, the volume of the droplet can be determined based on the measured droplet shape profiles with a reasonable assumption of the droplet being axisymmetric. Fig. 9 shows the time histogram of the volume expansion, V/VO, of the droplet in the course of the icing process, where VO is the initial volume of the water droplet. It can be seen clearly that the volume of the droplet was found to increase significantly at the beginning of the icing process since the majority of the droplet was still liquid water. The volume expansion rate was found to decrease rapidly with time since less and less liquid water was found to remain in the droplet. At the time about 35 seconds (i.e., t ≈ 35.0s) after the droplet impinged onto the frozen test plate, the volume expansion profile was found to become a flat line, which indicates that the volume of the droplet will not change with time anymore since the water droplet has been turned into solid ice crystal completely, which was visualized also quantitatively from the MTT measurement results given in Fig. 6. 350 300 250 200 t = 35.0s t = 30.0s t = 20.0s t = 10.0s t = 5.0s t = 0.0s 150 100 50 0 -400 -300 -200 -100 0 100 200 300 400 X (μm) Fig. 8: The shape profile of the icing droplet vs. time Specific weight (γ) Based on the phosphorescent images and MTT measurement results given in Fig. 6, the contour profiles of the icing droplet in the course of icing process can also be extracted, which are given in Fig. 8. The dynamic change of the droplet shape with time in the course of icing process was revealed quantitatively. It can be seen clearly that the water droplet was round, as a cap of a sphere, at the beginning (i.e., the contour profile of t = 0.5s). As visualized clearly in the MTT measurements described above, the liquid water at the bottom of the droplet would be frozen and turned to solid ice rapidly, while the upper portion of the droplet was still in liquid state. As the time goes by, the droplet would grow upward with more and more liquid water turning into solid ice within the droplet. The rounded, spherical-cap-shaped profile was 1.10 1.10 1.05 1.05 Specific weight (γ) Volume expension (V/VO) γ = 0.9167 for pure ice 1.00 0.95 0.90 1.00 0.95 0 5 10 15 20 25 30 Volume expension (V/VO) 24 Y (μm) O Averaged liquid temperature in the droplet ( C) found to become sharpened substantially to become an oliveseed-shaped profile. Eventually, the spherical-cap-shaped water droplet was found to turn to be a puddle-shaped ice crystal. 28 0.90 35 Time (s) Fig. 9: The volume (V/VO) and the specific weight (γ) of the icing droplet vs. time 6 Copyright © 2009 by ASME The time variation of the averaged specific weight (thereby density) of the droplet, γ , in the course of the icing process can also be determined based on the measured volume expansion profile. The results were also given in Fig. 9. For comparison, the standard value of the specific weight of pure ice (i.e., γice =0.9168) was also given in the figure as the dashed straight line. It can be seen clearly that the specific weight (or density) of the droplet was found to become smaller and smaller as more and more liquid water within the droplet turned into solid ice. As it is expected, the profile of the measured specific weight of the icing droplet was found to approach the standard value of the specific weight of ice (i.e., γ ice = 0.9168) as the time goes by. When the water droplet has been turned into solid ice crystal completely at t = 35.0s, the measured value of the specific weight of the ice crystal was found to be γ = 0.9165, which agree with the standard value of specific weight of pure ice γ ice = 0.9168 very well. The required frozen time, which is defined as the time interval between the moment when a water droplet impinged on the cold test plate and the moment when the water droplet was found to turn to an ice crystal completely, can also be determined based on the time sequence of the MTT measurements. Fig. 10 shows the variations of the required frozen time of the water droplets with the surface temperature of the test plate changed from -1.0 °C to -5.0 °C. As it is expected, the required frozen time for the water droplets (initial temperature at 20.5°C) turning into ice crystal was found to strongly depend on the temperature of the test plate. The required frozen time was found to decrease exponentially with the decreasing surface temperature of the test plate. 70 60 Experimental data Exponential curve fit Time (s) 50 40 30 20 10 -6 -5 -4 -3 -2 -1 0 0 Surface Temperature of Test Plate ( C) Fig. 10: The required frozen time vs. the test plate temperature Based on the measurement results as those shown in Fig. 4 to Fig. 10, important micro-physical phenomena pertinent to ice formation and accreting process as water droplets impinging on wind turbine blades were revealed quantitatively. Such measurements are highly desirable to improve our understanding about the important micro-physical processes pertinent to wind turbine icing phenomena in order to explore effective and robust anti-/de-icing strategies tailored for wind turbine icing mitigation to ensure safer and more efficient operation of wind turbines in cold weather. CONCLUSIONS A lifetime-based molecular tagging thermometry (MTT) technique was developed and implemented to quantify unsteady heat transfer and phase changing process inside small icing water droplets pertinent to wind turbine icing phenomena. For MTT measurements, a pulsed laser is used to “tag” phosphorescent molecules premixed within small water droplets. Long-lived laser-induced phosphorescence is imaged at two successive times after the same laser excitation pulse. The temperature measurement is achieved by taking advantage of the temperature dependence of phosphorescence lifetime, which is estimated from the intensity ratio of the acquired phosphorescence image pair. The lifetime-based MTT technique was first used to achieve temporally-and-spatially resolved temperature distribution measurements within small, convectively-cooled water droplets to quantify unsteady heat transfer within the small water droplets in the course of convective cooling process. The time evolution of phase changing process within small icing water droplets was also quantified based on the MTT measurements. It was revealed clearly that the water droplet was round, as a cap of a sphere, at the beginning as it impinged onto the test plate. The liquid water at the bottom of the droplet would be frozen and turned to solid ice rapidly, while the upper portion of the droplet was still in liquid state. As the time goes by, the interface between the liquid phase water and solid phase ice was found to rise upward continuously, indicating more and more liquid water within the droplet turned into solid ice. The rounded, spherical-cap-shaped profile of the water droplet was found to become sharpened continuously to become a prolatespheroid-shaped profile. Eventually, the spherical-cap-shaped water droplet was found to turn to a prolate-spheroid-shaped ice crystal. Due to the releasing of the latent heat of solidification as the liquid water turned to solid ice, the temperature of the remaining liquid water within the icing droplet was found to increase rather than decrease continuously in the course of icing process until the droplet was turned to solid ice crystal completely. While the volume of the droplet was found to increase with time monotonically, the specific weight, thereby the density, of the droplet was found to decrease with time in the course of icing process, approaching the standard value of pure ice when the droplet turned into ice crystal completely. The required frozen time of the droplet was found to strongly depend on the temperature of the test plat, which would decrease exponentially with the decreasing surface temperature of the test plate. Such measurements are highly desirable to elucidate underlying physics to improve our understanding about important micro-physical processes pertinent to wind turbine icing phenomena for safer and more efficient operation of wind turbines in cold weather. 7 Copyright © 2009 by ASME ACKNOWLEDGMENTS The authors want to thank Dr. M. M. Koochesfahani of Michigan State University for providing chemicals used for the present study. The support of National Science Foundation CAREER program under award number of CTS-0545918 is gratefully acknowledged. REFERENCES [1]. H. Hu and M. Koochesfahani, Molecular tagging velocimetry and thermometry and its application to the wake of a heated circular cylinder, Meas. Sci. Technol., 17 (2006) 1269-1281. [2]. Q. Lu and A. Melton, Measurement of transient temperature field within a falling droplet, AIAA Journal, 38, (2000) 95-101. [3]. M. Wolff, A. Delconte, F. Schmidt, P. Gucher and F. Lemoine, High-pressure diesel spray temperature measurements using two-color laser induced fluorescence, Meas. Sci. Technol., 18 (2007) 697-706. [4]. A. Omrane, G. Juhlin, F. Ossler, and M. Alden, Temperature measurements of single droplets by use of laser-induced phosphorescence, Applied Optics, 43 (2004) 3523-3529. [5]. A. Omrane, S. Santesson, M. Alden and S. Nilsson, Laser techniques in acoustically levitated micro droplets, Labon-a-Chip, 4 (2004) 287-291. [6]. H. Hu, C. Lum and M. Koochesfahani, Molecular tagging thermometry with adjustable temperature sensitivity, Exp. Fluids, 40 (2006) 753-763. [7]. Pringsheim, P., Fluorescence and Phosphorescence New York: Interscience, 1949. [8]. H. Hu and M. M. Koochesfahani, A novel technique for quantitative temperature mapping in liquid by measuring the lifetime of laser induced phosphorescence, Journal of Visualization,.6 (2003)143–153. [9]. W. K. Hartmann, M. H. B. Gray, A. Ponce and D. G. Nocera, Substrate induced phosphorescence from cyclodextrin-lumophore host-guest complex, Inorg. Chim. Acta., Vol. 243 (1996) 239-248. [10]. M. M. Koochesfahani and D. G. Nocera, Molecular Tagging Velocimetry, Handbook of Experimental Fluid Dynamics, Chapter 5.4, editors: J. Foss, C. Tropea and A. Yarin, Springer-Verlag, 2007. [11]. Z. Jin, Experimental Investigations of Micro-scale Thermal Flow Phenomena by Using Advanced Flow Diagnostic Techniques, Ph.D. Thesis, Iowa State University, Dec. 2008. [12]. J. D. Cutnell and K. W. Johnson. Physics, 3rd Edition. New York: Wiley, 1995: 315. 8 Copyright © 2009 by ASME