FM1D14 Series Electronic Time Switches __________________________________________________________________________ http://waterheatertimer.org/Programmable.html#module Project: Location: FM1D14 Series Product Type: One Channel Panel Mount The FM1D14 Series One Channel Electronic Time Switches are compact electronic 24-Hour/7-Day modules with heavy-duty relay contacts for switching low or line voltage loads. The timers are applicable for time-of-day control of pumps, fans, heaters, HVAC control circuits, lighting, machinery and many other types of commercial, industrial, and agricultural equipment. Contact/Phone: Model #: Features • 24-Hour or 7-Day applications • 14 setpoint programs • Easy-to-follow menu driven programming • Manual override with status indication • Rechargeable battery with backup protection up to 2500 hours • LCD display • 5 preset adjustable block programs Ratings Size: 2.36" x 2.36" (60 mm x 60 mm) Power Consumption: 1.4 W Supply Voltage: 12 VDC, 24 VAC/VDC, 120-277 VAC, 50/60 Hz Switch Rating: SPDT relay N.O. Contact: 15A, 277 VAC, General Use 10 FLA, 60 LRA, 250 VAC 1 ⁄2 HP, 120 VAC 1 HP, 250 VAC 1000 W, 120 VAC, Tungsten 8 A, 277 VAC, Ballast B300 Pilot Duty 4.9 A ,120 VAC, Electronic Ballast FM1D14 N.C. Contact: 15 A, 277 VAC, General Use 10 FLA, 60 LRA, 250 VAC 1 ⁄2 HP, 120/240 VAC 12 A, 24 VDC, Resistive 8 A, 120 VAC, Ballast Wiring Connections: ¼" quick connect terminals Operating Temperature: -40ºF to 131ºF (-40ºC to 55ºC) (limited display function at -13˚F) Shipping Weight: .10 lbs Warranty: Limited 1 year #E10694 Energy Controls FM1D14 Series Model Number Voltage Programs Mounting FM1D14-12* 12 VDC 14 Panel FM1D14-24 24 VAC/VDC 14 Panel 120-277 VAC 14 FM1D14-AV *24V model will operate on AC or DC Typical Wiring (24-277 VAC Application) Panel Specification M M control shall have Furnish and install a Grässlin FM1D14____24-Hour/7-Day electronic time switch. This 1-circuit 24-Hour/7-Day programming, 7 ON and 7 OFF setpoint programs, COM and 5 preset selection of NO NC block programs to allow a COM NO NC any combination of days for different weekday schedules. time of 1day in2 AM/PM format. 2 The LCD 3 4 A Daylight 3 shall4display 5 5 1 Saving Time adjustment button shall also be provided. The time switch will be programmable to-the-minute and also offer a manual override for temporary ON or OFF to the next scheduled LOAD Normallyevent. The LCD shall provide load status indication. The SPDT relay output will be rated for 15A General UseOpen @277 VAC. For carryover, 24-277 the timer module shall (Dry Contact) VAC have a rechargeable battery with 2500 hour reserve carryover. L1 Diagrams Normally Closed (Dry Contact) L2/N L1 L2/N TypicalTypical WiringWiring (24-277 VAC Application) (24-277 VAC Application) Typical Wiring (12 VDC Application) M M M COM COMNO 1 12 2 3 3 4 NC NO 45 L2/N L2/N L1 M - 5 1 12 1 2 + COM COM NO NO NC NC COM NO NC Normally Normally Open Open (Dry Contact) (Dry Contact) L1 M+ 2 3 34 3 45 LOAD LOAD 24-27724-277 VAC VAC12 VDC Normally ClosedClosed Normally (Dry Contact) (Dry Contact) L1 L1L2/N L2/N (+) Typical Wiring (24 VDC Application) 4 5 NC 5 - 1 12 2 COM COM NO 3 34 (+) (+) (-) (-) NO 4 NC 5 LOAD 24 VDC (+) + M+ - M - 1 12 2 COM COM NO NC 5 .14 in [3.56 mm] 3 34 NC NO 45 LOAD LOAD NC 5 2.36 in. [60 mm] 24 VDC 24 VDC (+) (+) (-) (-) .14 in [3.56 mm] Energy Controls 3 LOAD (-) LOAD LOAD 12 VDC 12 VDC 2 (-) TypicalTypical WiringWiring (24 VDC (24Application) VDC Application) NC NO 45 COM 1 2.13 in. [54 mm] M+ - M - 2.36 in. [60 mm] TypicalTypical WiringWiring (12 VDC (12Application) VDC Application) + M www.intermatic.com 1 2 3 4 5 1.26 in. [32 mm]