WFC3 SMOV Science Report 03 September 2009

advertisement
WFC3 SMOV Science Report
03 September 2009
This presentation contains material that is embargoed until after the SM4 ERO
press conference. Images/spectra of external (astronomical) objects may not
be altered, distributed, reproduced, published, displayed, or used in any other
way without the consent of the STScI Director or the HST Project.
03 September 2009
1
SMOV WFC3 Status
• 99% of visits completed (425/429)
• Remaining:
– 11432 - UVIS Flats, 4 visits
• 1 on 3 Sept,
• 2 on 9 Sept,
• 1 on 11 Sept
03 September 2009
2
WFC3 SMOV Status
Activity PropID Title
PI
Start Date
WF01
WF02
WF03
WF04
WF05
WF06
WF07
WF08
WF09a
WF09b
WF10a
WF10b
WF11
WF12
WF13
WF14
WF15
WF16
WF17
WF18
WF19
WF20
WF21
WF22
WF23
WF24
WF25
LP
ID
ID
JM
JM
SB
PM
HB
SB
SB
SB
SB
GH
GH
SB
BH
SB
LP
LP
SB
AR
BH
GH
GH
GH
GH
GH
26-May-13
26-May-13
27-May-13
05-Jun-13
05-Jun-13
13-Jun-13
16-Jun-13
25-Jun-13
12-Jun-13
14-Jun-13
13-Jun-13
25-Jun-13
26-Jun-13
27-Jun-13
27-Jun-13
15-Jul-13
18-Aug-13
12-Jun-13
12-Jun-13
20-Jun-13
08-Jul-13
14-Jul-13
03-Jul-13
03-Jul-13
02-Aug-13
31-Jul-13
31-Jul-13
11454
11357
11358
n/a
n/a
11419
11420
11421
11422
11529
11423
11543
11424
11425
11426
11427
11428
n/a
n/a
11431
11432
11433
11434
11435
11436
11437
11438
Activation Test
Memory Test
Sci Data Buffer Test
UVIS CCD Cooldown
IR Detector Cooldown
UVIS Det Functional
IR Det Functional
CSM Test
UVIS SOFA Test
UVIS Spare Tungsten
Lamp
IR FSM Test
IR Spare Tungsten Lamp
UVIS Initial Alignment
IR Initial Alignment
UVIS Contam Monitor
UVIS Shutter Test
D2 Cal Lamp Test
UVIS TEC Performance
IR TEC Performance
UVIS Hot Pixel Anneal
UVIS Int Flats
IR Int Flats
UVIS Fine Alignment
IR Fine Alignment
UVIS Image Quality
IR Image Quality
UVIS PSF Wings
03 September 2009
End Date Visits Allocated Visit Prog. Analysis Results
Done Visits credit Status Status
09-Jun-13
7
8
1 complete complete nominal
26-May-13
1
1
0 complete complete nominal
28-May-13 13
14
1 complete complete nomina
05-Jun-13
0
0
0 complete complete nominal
05-Jun-13
0
0
0 complete complete nominal
14-Jun-13 12
12
0 complete partial nominal
25-Jun-13 12
12
0 complete partial nominal
25-Jun-13
2
2
0 complete complete nominal
13-Jun-13
2
2
0 complete complete nominal
14-Jun-13
2
2
0 complete complete nominal
13-Jun-13
4
4
0 complete complete nominal
26-Jun-13
4
4
0 complete complete nominal
28-Jun-13
3
4
1 complete complete nominal
29-Jun-13
3
4
1 complete complete nominal
05-Aug-13 21
34
13 complete partial
15-Jul-13
3
3
0 complete partial
20-Aug-13 12
12
complete partial
19-Jun-13
0
0
0
? under study
19-Jun-13
0
0
0
? under study
22-Jul-13
6
6
0 complete complete 75% of pixels repaired
03-Sep-13 62
66
ongoing partial
4 visits remaining - sept 3,9,11
22-Jul-13
50
50
0 complete partial
09-Jul-13
4
4
0 complete partial
11-Jul-13
4
4
0 complete partial
02-Aug-13 1
1
0 complete partial
31-Jul-13
1
1
0 complete partial
03-Aug-13 4
5
1 complete partial
3
WF26 11439
WF27/2811549
WF29 11442
WF30 11443
WF31 11444
WF32 11445
WF33 11446
WF34 11447
WF35 11448
WF36 11449
WF37 11450
WF38 11451
IR PSF Wings
UVIS & IR Pointing
Stability
FGS-UVIS Update
FGS-IR Update
UVIS Plate Scale
IR Plate Scale
UVIS Dark, Noise, Backgnd
IR Dark, Noise, Backgnd
UVIS SAA Passage
IR SAA Passage
UVIS Phot Zero Points
IR Phot Zero Points
GH 01-Aug-13 01-Aug-13
TB 23-Aug-13 25-Aug-13
LD 14-Jul-13 14-Jul-13
LD 14-Jul-13 14-Jul-13
LD 16-Jul-13 16-Jul-13
LD 24-Jul-13 03-Aug-13
SB 27-Jun-13 30-Aug-13
PM 27-Jun-13 18-Aug-13
AM 01-Jul-13 01-Jul-13
AM 28-Jun-13 04-Jul-13
JK 14-Jul-13 12-Aug-13
JK 14-Jul-13 14-Aug-13
1
12
1
1
2
2
22
22
3
3
4
8
1
12
1
1
2
2
23
22
3
3
4
8
0
0
0
0
0
complete partial
complete partial
complete ongoing
complete ongoing
complete ongoing
complete ongoing
complete partial
complete partial
complete completed
complete complete
complete partial
complete partial
2
2
0
complete
3
4
3
4
0
0
complete partial
complete complete Nominal, throughput ~5-15% higher
than TV3
complete complete Shutter motion same as TV3. 2%
breathing effect
complete complete "pinning" effective
WF39
11452 UVIS Flat Field Uniformity
ES
WF40
WF42
11453 IR Flat Field Uniformity
11552 IR Grisms
BH 17-Jul-13 18-Jul-13
HB 04-Aug-13 07-Aug-13
WF43
11798 UVIS PSF Core Modulation ES
24-Jul-13
30-Jul-13
2
2
0
WF44
11808 UVIS Bowtie Monitor
Visit Count
Percent complete
Percent complete
12-Jun-13
10-Aug-13
100
425
95%
99%
100
448
0
19
JM
16-Jul-13
19-Jul-13
0
0
0
0
1
partial
within 0.1 arcsec per coord
within 0.3 arcsec per coord
residual rms ~0.05 pixels
preliminary results
preliminary results
contours defined
contours defined
throughput 15-20% higher than TV3
throughput 10-15% higher than TV3
< 3%, at 1 sigma
wrt initially allocated visits
wrt final visit count
PIs : LP = Petro, JM = Mackenty, SB = Baggett, PM = McCullough, HB = Bushouse, GH = Hartig, AR = Rajan, TB = Brown or Borders, AM = Martel, JK = Kalira, ES=Sabbi
03 September 2009
4
11552: Characterization of the
WFC3 IR Grisms
• Objective: Verify image displacement, spectral trace and
dispersion, and throughput of the IR G102 and G141
grisms as a function of position on the FOV.
• Activity: Observe GD 153 in 5 point pattern. Obtain
exposures at 9 locations within the FOV of PN HB12.
• 4 visits, 4 orbits.
• Results:
– Compared to predicted values from ground tests
– throughput is ~10% higher
– wavelength solution is good, ~ 1%
03 September 2009
5
11549: UVIS and IR Pointing
• Objective: Measure the pointing stability of the WFC3
UVIS and IR channels with a series of short observations
of a globular cluster.
• Activity: 36 orbits
– Observations are taken:
• 1) constant thermal attitude for 10 orbits then 2 orbits
• 2) hot thermal attitude for 10 orbits then 2 orbits in cold attitude.
• 3) cold thermal attitude for 10 orbits, then 2 orbits in hot attitude
• Results:
– Match predicted values based on ground tests
• measured positions are stable to +/- 0.1 pixels in x and y
• average offset is below 0.2 pixels
• maximum offset is 0.25 pixels
03 September 2009
6
Other Updates
Ongoing investigations:
• “Blobs” observed in external images– ‘stuff’ on the CSM, confirmed through shift in CSM position,
blobs moved with change CSM position
– telemetric study of position shift ongoing
• Light Leaks
– cross contamination program
•
The effect formerly known as IR QEH (TEFKAQ)
– DCL at GSFC are performing tests on similar IR detectors, can
reproduce the effect
03 September 2009