Lake Tahoe National Forest Pathways Handbook Fuelbed Pathways Handbook Lake Tahoe Basin Management Unit – Angora Fire Area FCCS Fuelbeds—October, 2010 1 Lake Tahoe National Forest Pathways Handbook Introduction The Lake Tahoe Basin Management Unit (LTBMU) collaborated with the Fire and Environmental Research and Applications (FERA) team of the Pacific Wildland Fire Research Laboratory to create a comprehensive set of Fuel Characteristic Classification System (FCCS) fuelbeds (Ottmar et al. 2007; Riccardi et al. 2007) representing the past, current and potential future conditions of major forest types, management activities, and natural disturbances occurring within the Angora fire area of the management unit. The fuelbeds are arranged in management and successional pathways initiated by a stand-replacement event. In most cases the event is a stand-replacement wildfire, but in some pathways clearcut harvests are a secondary initiation point. While we recognize that most stands in the area were established following clearcuts in the late 1800s and early 1900s, the disturbances included in the pathways are intended to reflect more recent and future initiation of the forest types on Lake Tahoe Basin Management Unit lands. Fuelbed pathways were developed through site visits and meetings between FERA researchers and LTBMU and other Pacific Southwest Region personnel. Lists of fuelbeds were created representing major forest types and common management activities and natural disturbances (see Table 1 for descriptions of treatments and natural change agents). In additional, several fuelbeds were added to the fuelbed list allowing complete assignment of fuelbeds to vegetation attributes for the Lake Tahoe basin region. Fuelbeds provided in the FCCS system or similar fuelbeds from projects on The Okanogan-Wenatchee and Deschutes Nationa Forests were often used as starting points for creating the LTBMU fuelbeds. Local data, plant association guides, photo series and expert opinion were used to modify the fuelbeds to represent past, current and potential future fuel conditions on the LTBMU. Information from the fuelbed pathways is summarized in tables including a description, the age class, and any management actions or natural change agents associated with each fuelbed. Fuelbeds were calculated in FCCS version 2.1 and the surface fire behavior; FCCS crown fire, surface fire and available fuels potentials; reaction intensity, rate of spread, and flame length (Sandberg et al. 2007a; Sandberg et al. 2007b); and suggested crosswalks to the original Fire Behavior Prediction System (Rothermel 1972, Albini 1976) and standard fuel models (Scott and Burgan, 2005) at three moisture scenarios, mid-flame windspeeds and slopes are presented in summary tables. Each of the 76 fuelbeds are available from the FERA website for input into the FCCS allowing additional outputs to be observed including fuel loading and available carbon by fuelbed category. The vegetation attributes were used to map the LTBMU fuelbeds and it was discovered that there were more vegetation types than fuelbed types developed for the basin. Additional fuelbeds were added to this handbook with description 2 Lake Tahoe National Forest Pathways Handbook Representative photos for each fuelbed, when available, are provided in Appendix A. Photos are intended to illustrate general structural features of the fuelbeds and may not represent actual species composition or fuel loadings. Table 1. Descriptions of harvest types, fuel treatments and natural change agents in the Lake Tahoe Basin Management Unit fuelbeds. Harvest / Fuel Treatment Select Cut Clearcut Precommercial Thin (PCT) Salvage Pile & burn Pile (no burn) Prescribed (Rx) Fire Mastication None Natural Change Agent Wildfire Wildfire (ground) Insects & Disease Avalanche None Description Thinning harvest in which large trees are removed from a stand. Sometimes termed “thinning from above.” Harvest of all or nearly all trees in a forest stand. Thinning harvest in which small trees are removed throughout a forest stand to increase growth, decrease ladder fuels, and achieve other management objectives. Dead and/or live tree removal from an area that has burned by a wildfire. Concentration of woody fuels into piles and burning. Concentration of woody fuels into piles that will be burned in the future. Application of controlled fire to obtain planned objectives for silviculture, wildlife habitat, grazing, and fire hazard reduction. Conversion of woody fuels into a small, densely packed layer through mechanical grinding. No harvest or fuel treatment. Description An unplanned wildland fire including unauthorized human-caused fires, escaped wildland fire use events, escaped prescribed fire projects, and all other wildland fires where the objective is to put the fire out. A wildfire confined to surface fuels. Mortality of trees and other vegetation from insect attacks and disease, leading to accumulation of dead fuels. Disturbance to vegetation from snow and/or ice slides. No change agent. 3 Lake Tahoe National Forest Pathways Handbook Index to fuelbed pathways 1. Jeffrey pine – white fir . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2. Red fir . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 3. Wet lodgepole pine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 4. Whitebark pine – Lodgepole pine . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 5. Mountain hemlock forest. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 6. Mixed conifer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 4 Lake Tahoe National Forest Pathways Handbook 1. Jeffrey pine – white fir pathways 5 Lake Tahoe National Forest Pathways Handbook 1. Jeffrey pine – white fir fuelbed descriptions FuelbedID Age class Harvest / (yr) fuel treatment Change agent LT001 0-7 None Wildfire LT002 7-25 None None LT003 25-50 None None LT004 50-80 None None LT005 80-120 None None LT006 120+ None None LT007 80-120 Select cut, RX fire Wildfire (ground) LT008 80-120 Select cut None LT009 80-120 Select cut, pile & burn None LT010 80-120 Select cut, Pile (no burn) None LT011 120+ Select cut, RX fire None Fuelbed name / description Jeffrey pine and white fir forest. Occurs at middle elevations in the Lake Tahoe Basin. Established following stand-replacement wildfire less than 7 years ago, resulting in a shrubland with snags and less than 10% live overstory tree cover. Jeffrey pine and white fir forest. Occurs at middle elevations in the Lake Tahoe Basin. Established following stand-replacement wildfire 7 to 25 years ago with no subsequent management. Jeffrey pine and white fir seedlings and saplings have become established within the thinning shrub cover. Jeffrey pine and white fir forest. Occurs at middle elevations in the Lake Tahoe Basin. Established following stand-replacement wildfire 25 to 50 years ago with no subsequent management. Stands composed of high density poles. Jeffrey pine and white fir forest. Occurs at middle elevations in the Lake Tahoe Basin. Established following stand-replacement wildfire 50 to 80 years ago with no subsequent management. Stands have a single layer, medium density canopy and medium woody fuel load. Jeffrey pine and white fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established following stand-replacement wildfire 80 to 120 years ago with no subsequent management, resulting in a high density stand. Jeffrey pine and white fir forest. Occurs at middle elevations in the Lake Tahoe Basin. Established more than 120 years ago following stand-replacement wildfire with no subsequent management, resulting in a high density stand. Jeffrey pine and white fir forest. Occurs at middle elevations in the Lake Tahoe Basin. Established following stand-replacement wildfire 80 to 120 years ago. Stand structure is the result of recent select tree harvest and prescribed fire or low intensity wildfire. Jeffrey pine and white fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established following stand-replacement wildfire 80 to 120 years ago. Stand structure is the result of a recent select tree harvest with no woody fuels treatment. Jeffrey pine and white fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 80 to 120 years ago following stand-replacement wildfire. Stand structure is the result of a recent select tree harvest with woody fuels reduced by piling and burning. Jeffrey pine and white fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 80 to 120 years ago following stand-replacement wildfire. Stand structure is the result of a recent select tree harvest with woody fuels piled but not burned. Jeffrey pine and white fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established more than 120 years ago following stand-replacement wildfire. Stand structure is the result of a recent select tree harvest with woody fuels reduced by prescribed burning or piling and burning. 6 Lake Tahoe National Forest Pathways Handbook FuelbedID Age class Harvest / (yr) fuel treatment Change agent LT012 120+ Select cut None LT013 0-10 None Wildfire LT014 10-25 None None LT015 120+ None None LT016 120+ Select cut None LT017 120+ Select cut, RX fire, pile burn None LT018 120+ Select cut LT019 120+ Select cut, Pile (no burn) None LT020 120+ Select cut, Pile (no burn) None LT082 0-7 Salvage Wildfire LT083 7-25 None None None Fuelbed name / description Jeffrey pine and white fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Stand structure is result of a recent select tree harvest with no woody fuels treatment. Jeffrey pine and white fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established following stand-replacement wildfire less than 10 years ago, resulting in a grassland with snags and less than 10% live overstory tree cover. Jeffrey pine and white fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 10 to 25 years ago following stand-replacement wildfire with no subsequent management. Dense dry seedlings and saplings have become established. Jeffrey pine and white fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Stand has had select tree harvest followed by prescribed fire in the past but has had no recent management. Jeffrey pine and white fir forest. Occurs at middle elevation of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Stand structure is the result of two select tree harvests with no woody fuel reduction treatments. Jeffrey pine and white fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Recent select tree harvest with woody fuels reduced by prescribed burning or piling and burning. Jeffrey pine and white fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Stand has had a recent select tree harvest with no woody fuel reduction treatment. Jeffrey pine and white fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Stand has had a recent select tree harvest with woody fuels piled but not burned. Jeffrey pine and white fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Stand had a select tree harvest with woody fuels piled and burned in the past and has had a recent select tree harvest with woody fuels piled but not burned. Jeffrey pine and white fir forest. Occurs at middle elevations in the Lake Tahoe basin. Established following stand-replacement wildfire and salvage harvest less than 7 years ago, resulting in a shrubland with few snags and less than 10% understory tree cover. Jeffrey pine and white fir forest. Occurs at middle elevations in the Lake Tahoe Basin. Established following stand-replacement wildfire and salvage harvest 7 to 25 years ago with no subsequent management. Jeffrey pine and white fir seedlings and saplings have become established in the thinning shrub cover. 7 Lake Tahoe National Forest Pathways Handbook FuelbedID Age class Harvest / (yr) fuel treatment LT084 80-120 LT087 120+ Change agent Select cut, Mastication None None None Fuelbed name / description Jeffrey pine and white fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established following stand-replacement wildfire 80 to 120 years ago. Stand structure is the result of a recent select tree, cut to length harvest with mastication of logging slash and small shrubs and trees. Jeffrey pine and white fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Stand has had select tree harvest followed by mastication in the past but has had no subsequent management. 8 Lake Tahoe National Forest Pathways Handbook 1. Jeffrey pine – white fir fuelbed FCCS outputs Jeffrey pine – white fir fuelbed FCCS Outputs Fuelbed LT002 Fuelbed LT001 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 5.2 5.2 5.2 5.2 5.2 5.2 5.2 5.2 5.2 0.6 0.7 0.9 1.8 1.8 1.9 3.2 3.2 3.2 1.0 1.1 1.4 3.0 3.0 3.1 5.2 5.2 5.3 1.2 1.4 1.7 3.6 3.6 3.7 6.2 6.2 6.3 0.1 0.2 0.2 1.2 1.2 1.3 3.9 3.9 4.0 0.2 0.3 0.5 2.3 2.4 2.6 7.8 7.8 8.0 0.3 0.4 0.6 3.0 3.1 3.3 10.0 10.1 10.3 213 213 213 313 313 413 623 623 623 213 213 213 313 313 413 623 623 623 213 213 213 313 313 413 623 623 623 8 8 8 8 8 8 9 9 9 8 8 8 9 9 9 10 10 10 8 8 8 9 9 9 12 12 12 TL3 TL3 TL3 TL7 TL7 TL7 TL8 TL8 TL8 TL3 TL3 TL3 TL8 TL8 TL8 TU2 TU2 TU2 TL3 TL3 TL7 TL8 TL8 TL8 SB2 SB2 SB3 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 1.5 1.7 2.1 2.3 2.3 2.5 3.9 3.9 4.0 2.1 2.3 2.8 3.8 3.8 4.0 6.4 6.4 6.6 2.5 2.8 3.4 4.7 4.7 5.0 8.0 8.0 8.2 0.9 1.1 1.7 2.1 2.2 2.5 6.7 6.8 7.1 1.2 1.5 2.4 4.4 4.6 5.2 14.1 14.3 14.9 1.6 2.0 3.2 6.2 6.5 7.3 19.8 20.1 21.0 312 312 312 422 422 522 822 822 822 312 312 312 422 422 522 822 822 822 312 312 312 422 422 522 822 822 822 8 8 9 9 9 9 9 9 10 9 9 9 9 9 10 12 12 12 9 9 9 10 10 10 12 13 13 TL7 TL7 TL3 TL5 TL5 TL5 TL9 TL9 TU2 TL3 TL5 TL5 TL9 TL9 TU2 SB3 SB3 SB3 TL5 TL5 TL8 TU2 TU2 TU2 SB3 SB2 SB3 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 9 Lake Tahoe National Forest Pathways Handbook Fuelbed LT004 Fuelbed LT003 Jeffrey pine – white fir fuelbed FCCS Outputs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario Windspeed mph 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 Slope % 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 2.9 3.2 4.1 6.9 7.0 7.4 11.7 11.8 12.0 3.8 4.3 5.4 9.3 9.5 10.0 15.9 16.0 16.3 4.5 5.0 6.5 11.0 11.2 11.8 18.8 18.9 19.3 1.5 1.8 3.0 9.3 9.7 10.9 29.7 30.1 31.3 2.1 2.7 4.6 14.9 15.5 17.4 47.7 48.2 50.2 2.8 3.5 6.0 19.2 20.0 22.4 61.4 62.2 64.6 423 423 523 833 833 833 953 963 963 423 423 523 833 833 833 953 963 963 423 423 523 833 833 833 953 963 963 9 9 10 12 12 12 13 13 13 9 10 10 13 13 13 13 4 4 10 10 12 13 13 13 4 4 4 TL8 TL8 TU2 SB3 SB3 SB3 SB3 SB3 SB3 TL9 TU2 TU5 SB3 SB3 SB3 SB4 SH6 SH6 TU2 TU2 SB3 SB3 SB3 SB3 GR8 GR8 GR8 Reaction Intensity (1,000 btu/ft2/min) 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 Flame Length (ft) 2.6 2.9 3.7 3.5 3.7 4.4 5.8 5.8 6.0 3.3 3.7 4.7 4.8 5.0 5.6 8.1 8.1 8.3 4.0 4.4 5.7 5.9 6.0 6.8 9.7 9.8 10.1 Rate of Spread (ft/min) 1.6 2.0 3.5 3.2 3.6 5.0 9.2 9.4 9.9 2.2 2.8 4.8 5.1 5.4 6.9 15.4 15.7 16.6 2.9 3.7 6.4 6.8 7.2 9.3 20.5 20.9 22.1 FCCS Fire Potentials 424 424 424 544 544 544 854 854 854 424 424 424 544 544 544 854 854 854 424 424 424 544 544 544 854 854 854 Crosswalk – FBPS FMs 9 9 9 9 9 10 10 10 10 9 9 10 10 10 10 13 13 13 9 10 10 10 10 12 13 13 13 Crosswalk – Standard FMs TL5 TL5 TL8 TL8 TL8 TU2 TU5 TU5 TU5 TL8 TL8 TU2 TU2 TU2 TU5 SB2 SB3 SB3 TL9 TU2 TU5 TU5 TU5 SB3 SB3 SB3 SB3 Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 10 Lake Tahoe National Forest Pathways Handbook Fuelbed LT006 Fuelbed LT005 Jeffrey pine – white fir fuelbed FCCS Outputs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario Windspeed mph 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 Slope % 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 2.8 3.1 4.0 3.8 4.1 4.8 6.1 6.1 6.3 3.6 4.0 5.1 5.1 5.2 6.0 8.5 8.6 8.8 4.4 4.9 6.3 6.3 6.4 7.4 10.4 10.5 10.8 1.8 2.3 4.0 3.5 4.0 5.7 9.6 9.8 10.4 2.5 3.2 5.5 5.4 5.7 7.9 16.4 16.7 17.7 3.4 4.3 7.4 7.4 7.8 10.6 22.3 22.7 24.1 416 416 526 556 556 656 856 856 866 416 416 526 556 556 656 856 856 866 416 416 526 556 556 656 856 856 866 9 9 10 9 10 10 12 12 12 9 9 10 10 10 12 13 13 13 10 10 12 12 12 12 13 13 13 TL5 TL8 TU2 TL9 TU2 TU2 SB2 SB2 SB3 TL8 TL9 TU2 TU2 TU2 SB2 SB3 SB3 SB3 TU2 TU2 SB3 SB3 SB3 SB3 SB3 SB3 SB3 Reaction Intensity (1,000 btu/ft2/min) 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 Flame Length (ft) 2.0 2.3 2.9 2.6 2.8 3.3 3.7 3.8 4.2 2.5 2.8 3.6 3.3 3.5 4.1 4.6 4.8 5.2 3.2 3.5 4.5 4.1 4.4 5.2 5.8 6.0 6.6 Rate of Spread (ft/min) 1.8 2.3 4.0 3.2 3.70 5.4 6.8 7.3 8.9 2.5 3.2 5.5 4.4 5.1 7.4 9.4 10.0 12.3 3.4 4.3 7.4 6.0 6.9 10.0 12.6 13.5 16.6 FCCS Fire Potentials 316 416 516 446 546 546 656 656 756 316 416 516 446 546 546 656 656 756 316 416 516 446 546 546 656 656 756 Crosswalk – FBPS FMs 9 9 9 9 9 9 9 9 10 9 9 9 9 9 10 10 10 10 9 9 10 10 10 10 10 10 12 Crosswalk – Standard FMs TL3 TL5 TL8 TL5 TL6 TL8 TL8 TL9 TU4 TL5 TL5 TL8 TL8 TL8 TU2 TU4 TU4 TU4 TL8 TL8 TU2 TU2 TU2 TU4 TU3 TU3 SB3 Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 11 Lake Tahoe National Forest Pathways Handbook Fuelbed LT008 Fuelbed LT007 Jeffrey pine – white fir fuelbed FCCS Outputs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario Windspeed mph 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 Slope % 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 1.1 1.2 1.6 1.5 1.6 1.9 2.2 2.3 2.5 1.6 1.7 2.2 2.1 2.2 2.6 3.1 3.2 3.4 1.9 2.1 2.7 2.6 2.8 3.2 3.8 3.9 4.2 0.7 0.9 1.5 1.4 1.6 2.2 3.2 3.4 4.0 1.0 1.2 2.1 2.0 2.2 3.0 4.5 4.7 5.5 1.3 1.7 2.8 2.6 3.0 4.1 6.0 6.3 7.4 212 312 312 322 322 322 432 432 532 212 312 312 322 322 322 432 432 532 212 312 312 322 322 322 432 432 532 8 8 8 8 8 8 9 9 9 8 8 9 9 9 9 9 9 9 8 9 9 9 9 9 9 9 10 TL3 TL4 TL7 TL7 TL7 TL7 TL5 TL5 TL6 TL7 TL7 TL5 TL5 TL5 TL5 TL8 TL8 TL8 TL7 TL3 TL5 TL5 TL5 TL8 TL9 TL9 TU2 Reaction Intensity (1,000 btu/ft2/min) 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 Flame Length (ft) 2.3 2.5 3.2 3.0 3.2 3.7 4.4 4.5 4.9 2.9 3.2 4.1 3.9 4.1 4.8 6.1 6.2 6.4 3.6 4.0 5.0 4.9 5.1 6.0 7.9 8.0 8.2 Rate of Spread (ft/min) 1.3 1.6 2.6 2.5 2.8 3.8 5.5 5.8 6.8 1.8 2.2 3.6 3.4 3.8 5.3 9.0 9.1 9.7 2.4 3.0 4.9 4.6 5.1 7.1 13.0 13.3 14.1 FCCS Fire Potentials 315 415 415 435 435 535 645 645 645 315 415 415 435 435 535 645 645 645 315 415 415 435 435 535 645 645 645 Crosswalk – FBPS FMs 9 9 9 9 9 9 10 10 10 9 9 10 9 10 10 12 12 12 9 9 10 10 10 10 12 12 13 Crosswalk – Standard FMs TL5 TL5 TL8 TL8 TL8 TL8 TU2 TU2 TU2 TL8 TL8 TU2 TL9 TU2 TU2 SB2 SB2 SB3 TL8 TL9 TU2 TU2 TU2 TU5 SB3 SB3 SB3 Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 12 Lake Tahoe National Forest Pathways Handbook Fuelbed LT010 Fuelbed LT009 Jeffrey pine – white fir fuelbed FCCS Outputs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario Windspeed mph 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 Slope % 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 4.3 4.3 4.3 4.3 4.3 4.3 4.3 4.3 4.3 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 1.1 1.3 1.6 1.6 1.7 1.9 2.3 2.3 2.5 1.6 1.7 2.2 2.1 2.2 2.6 3.1 3.2 3.4 1.9 2.1 2.7 2.6 2.7 3.2 3.8 3.9 4.2 0.5 0.6 1.1 1.0 1.1 1.6 2.3 2.4 2.8 0.7 0.9 1.5 1.4 1.6 2.2 3.2 3.3 3.9 1.0 1.2 2.0 1.9 2.1 2.9 4.3 4.5 5.3 212 312 312 322 322 322 432 432 432 212 312 312 322 322 322 432 432 432 212 312 312 322 322 322 432 432 432 8 8 8 8 8 8 9 9 9 8 8 9 9 9 9 9 9 9 8 9 9 9 9 9 9 9 10 TL3 TL3 TL7 TL7 TL7 TL7 TL5 TL5 TL5 TL7 TL7 TL5 TL3 TL5 TL5 TL8 TL8 TL8 TL7 TL3 TL5 TL5 TL5 TL8 TL9 TL9 TU2 Reaction Intensity (1,000 btu/ft2/min) 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 Flame Length (ft) 1.1 1.3 1.6 1.6 1.6 1.9 2.3 2.3 2.5 1.5 1.7 2.1 2.1 2.2 2.6 3.1 3.1 3.4 1.9 2.1 2.6 2.6 2.7 3.2 3.8 3.9 4.2 Rate of Spread (ft/min) 0.5 0.7 1.1 1.0 1.2 1.6 2.4 2.5 2.9 0.7 0.9 1.5 1.4 1.6 2.2 3.2 3.4 4.0 1.0 1.2 2.0 1.9 2.2 3.0 4.4 4.6 5.4 FCCS Fire Potentials 213 313 313 323 323 323 433 433 433 213 313 313 323 323 323 433 433 433 213 313 313 323 323 323 433 433 433 Crosswalk – FBPS FMs 8 8 8 8 8 8 9 9 9 8 8 9 9 9 9 9 9 9 8 9 9 9 9 9 9 9 10 Crosswalk – Standard FMs TL3 TL3 TL7 TL7 TL7 TL7 TL5 TL5 TL5 TL7 TL7 TL5 TL3 TL5 TL5 TL8 TL8 TL8 TL7 TL3 TL5 TL5 TL5 TL8 TL9 TL9 TU2 Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 13 Lake Tahoe National Forest Pathways Handbook Fuelbed LT012 Fuelbed LT011 Jeffrey pine – white fir fuelbed FCCS Outputs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario Windspeed mph 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 Slope % 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 0.7 0.8 1.0 0.9 1.0 1.1 1.3 1.3 1.4 0.9 1.0 1.3 1.2 1.2 1.5 1.6 1.7 1.9 1.1 1.2 1.6 1.4 1.5 1.8 2.0 2.1 2.3 0.4 0.5 0.9 0.7 0.8 1.2 1.5 1.6 1.9 0.5 0.7 1.2 0.9 1.1 1.6 2.0 2.2 2.7 0.7 0.9 1.6 1.3 1.5 2.2 2.7 2.9 3.6 212 212 212 212 212 312 322 322 322 212 212 212 212 212 312 322 322 322 212 212 212 212 212 312 322 322 322 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 TL3 TL3 TL3 TL3 TL3 TL3 TL4 TL4 TL4 TL3 TL3 TL4 TL4 TL4 TL4 TL7 TL7 TU1 TL3 TL4 TL7 TL4 TL7 TL7 TL3 TL3 TL6 Reaction Intensity (1,000 btu/ft2/min) 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 Flame Length (ft) 1.3 1.5 1.9 1.7 1.8 2.2 2.7 2.8 2.9 1.7 1.9 2.4 2.4 2.4 2.8 3.8 3.9 4.0 2.1 2.3 3.0 3.0 3.1 3.4 4.8 4.9 5.0 Rate of Spread (ft/min) 0.8 1.0 1.8 1.4 1.6 2.4 3.9 4.0 4.4 1.1 1.4 2.5 2.4 2.5 3.3 6.7 6.9 7.5 1.5 1.9 3.3 3.2 3.4 4.4 9.1 9.3 10.1 FCCS Fire Potentials 314 314 314 324 324 424 534 534 534 314 314 314 324 324 424 534 534 534 314 314 314 324 324 424 534 534 534 Crosswalk – FBPS FMs 8 8 8 8 8 9 9 9 9 8 8 9 9 9 9 9 9 10 9 9 9 9 9 9 10 10 10 Crosswalk – Standard FMs TL3 TL4 TL7 TL7 TL7 TL5 TL6 TL6 TL8 TL7 TL7 TL5 TL5 TL5 TL5 TL9 TL9 TU2 TL3 TL5 TL8 TL8 TL8 TL8 TU4 TU4 TU4 Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 14 Lake Tahoe National Forest Pathways Handbook Fuelbed LT014 Fuelbed LT013 Jeffrey pine – white fir fuelbed FCCS Outputs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario Windspeed mph 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 Slope % 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 0.4 0.5 0.6 0.6 0.6 0.7 0.8 0.8 0.9 0.6 0.7 0.9 0.8 0.9 1.1 1.4 1.4 1.4 0.8 0.9 1.1 1.0 1.1 1.3 1.7 1.7 1.7 0.2 0.3 0.5 0.4 0.5 0.7 0.9 0.9 1.1 0.3 0.4 0.6 0.5 0.6 0.9 1.6 1.6 1.6 0.4 0.5 0.9 0.7 0.8 1.2 2.1 2.1 2.1 211 211 211 211 211 211 311 311 311 211 211 211 211 211 211 311 311 311 211 211 211 211 211 211 311 311 311 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 TL1 TL1 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL4 TL4 TL4 TL3 TL3 TL3 TL3 TL3 TL4 TL7 TL7 TL7 Reaction Intensity (1,000 btu/ft2/min) 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 4.3 4.3 4.3 4.3 4.3 4.3 4.3 4.3 4.3 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 Flame Length (ft) 1.9 2.1 2.7 2.6 2.8 3.2 3.9 4.0 4.2 2.5 2.8 3.5 3.6 3.6 4.2 6.1 6.1 6.2 3.1 3.4 4.3 4.5 4.5 5.2 7.5 7.6 7.7 Rate of Spread (ft/min) 1.3 1.6 2.7 2.5 2.8 3.9 6.1 6.2 7.1 1.8 2.2 3.7 3.8 4.0 5.4 11.9 12.1 12.6 2.4 3.0 4.9 5.3 5.5 7.2 16.5 16.8 17.5 FCCS Fire Potentials 313 313 413 423 423 523 723 723 723 313 313 413 423 423 523 723 723 723 313 313 413 423 423 523 723 723 723 Crosswalk – FBPS FMs 8 9 9 9 9 9 9 9 10 9 9 9 9 9 10 12 12 12 9 9 10 10 10 10 12 12 12 Crosswalk – Standard FMs TL7 TL3 TL5 TL5 TL5 TL8 TL9 TL9 TU2 TL5 TL5 TL8 TL8 TL8 TU2 SB2 SB2 SB3 TL8 TL8 TU2 TU2 TU2 TU2 SB3 SB3 SB3 Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 15 Lake Tahoe National Forest Pathways Handbook Fuelbed LT016 Fuelbed LT015 Jeffrey pine – white fir fuelbed FCCS Outputs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario Windspeed mph 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 Slope % 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 1.5 1.7 2.1 2.1 2.2 2.6 3.0 3.1 3.4 2.1 2.3 2.9 2.8 3.0 3.5 4.1 4.2 4.5 2.6 2.8 3.6 3.5 3.7 4.3 5.1 5.2 5.6 1.2 1.5 2.5 2.4 2.7 3.7 5.4 5.7 6.7 1.7 2.1 3.5 3.3 3.7 5.1 7.4 7.9 9.3 2.3 2.8 4.7 4.5 5.0 6.9 10.0 10.6 12.5 314 314 414 434 434 534 544 644 644 314 314 414 434 434 534 544 644 644 314 314 414 434 434 534 544 644 644 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 10 10 10 9 9 9 9 9 10 10 10 10 TL7 TL7 TL5 TL3 TL5 TL6 TL8 TL8 TL8 TL3 TL5 TL8 TL5 TL8 TL8 TU2 TU2 TU4 TL5 TL5 TL8 TL8 TL8 TU2 TU4 TU4 TU3 Reaction Intensity (1,000 btu/ft2/min) 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 Flame Length (ft) 2.2 2.4 3.0 2.9 3.1 3.6 4.2 4.3 4.7 2.8 3.1 3.9 3.7 3.9 4.6 5.4 5.5 6.0 3.4 3.8 4.8 4.6 4.9 5.7 7.0 7.0 7.4 Rate of Spread (ft/min) 1.2 1.5 2.5 2.3 2.6 3.6 5.1 5.4 6.4 1.7 2.1 3.5 3.2 3.6 5.0 7.2 7.5 8.9 2.3 2.8 4.7 4.3 4.9 6.7 10.4 10.6 11.9 FCCS Fire Potentials 315 415 415 425 425 425 535 535 635 315 415 415 425 425 425 535 535 635 315 415 415 425 425 425 535 535 635 Crosswalk – FBPS FMs 9 9 9 9 9 9 10 10 10 9 9 9 9 9 10 10 10 10 9 9 10 10 10 10 12 12 12 Crosswalk – Standard FMs TL5 TL5 TL8 TL8 TL8 TL8 TU2 TU2 TU2 TL5 TL8 TL9 TL8 TL9 TU2 TU5 TU5 TU5 TL8 TL9 TU2 TU2 TU2 TU5 SB3 SB3 SB3 Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 16 Lake Tahoe National Forest Pathways Handbook Fuelbed LT018 Fuelbed LT017 Jeffrey pine – white fir fuelbed FCCS Outputs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario Windspeed mph 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 Slope % 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 4.3 4.3 4.3 4.3 4.3 4.3 4.3 4.3 4.3 1.0 1.2 1.5 1.4 1.5 1.7 2.1 2.1 2.3 1.4 1.6 2.0 1.9 2.0 2.4 2.8 2.9 3.1 1.7 1.9 2.4 2.4 2.5 2.9 3.5 3.5 3.8 0.5 0.6 1.1 1.0 1.1 1.6 2.3 2.4 2.8 0.7 0.9 1.5 1.4 1.6 2.2 3.1 3.3 3.9 1.0 1.2 2.0 1.9 2.1 2.9 4.2 4.5 5.3 213 313 313 333 333 333 433 433 433 213 313 313 333 333 333 433 433 433 213 313 313 333 333 333 433 433 433 8 8 8 8 8 8 9 9 9 8 8 8 8 9 9 9 9 9 8 8 9 9 9 9 9 9 9 TL3 TL3 TL4 TL4 TL4 TL7 TL3 TL3 TL5 TL3 TL7 TL7 TL7 TL3 TL5 TL5 TL8 TL8 TL7 TL7 TL5 TL5 TL5 TL8 TL8 TL8 TL9 Reaction Intensity (1,000 btu/ft2/min) 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 5.2 5.2 5.2 5.2 5.2 5.2 5.2 5.2 5.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 Flame Length (ft) 2.3 2.6 3.2 3.1 3.2 3.8 4.4 4.5 4.9 2.9 3.2 4.1 3.9 4.1 4.8 5.7 5.8 6.1 3.6 4.0 5.1 4.8 5.1 5.9 7.4 7.4 7.6 Rate of Spread (ft/min) 1.2 1.5 2.5 2.2 2.5 3.6 4.9 5.2 6.2 1.7 2.1 3.5 3.1 3.5 4.9 7.3 7.5 8.5 2.3 2.8 4.7 4.2 4.7 6.6 10.6 10.8 11.5 FCCS Fire Potentials 316 416 416 436 446 446 546 546 646 316 416 416 436 446 446 546 546 646 316 416 416 436 446 446 546 546 646 Crosswalk – FBPS FMs 9 9 9 9 9 9 10 10 10 9 9 10 9 10 10 10 10 12 9 10 10 10 10 10 12 12 12 Crosswalk – Standard FMs TL5 TL5 TL8 TL8 TL8 TL9 TU2 TU2 TU2 TL8 TL8 TU2 TL9 TU2 TU2 TU5 TU5 SB2 TL8 TU2 TU2 TU2 TU2 TU5 SB3 SB3 SB3 Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 17 Lake Tahoe National Forest Pathways Handbook Fuelbed LT020 Fuelbed LT019 Jeffrey pine – white fir fuelbed FCCS Outputs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario Windspeed mph 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 Slope % 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 1.0 1.1 1.4 1.4 1.5 1.7 2.0 2.1 2.2 1.3 1.5 1.9 1.8 1.9 2.2 2.6 2.7 2.9 1.7 1.8 2.3 2.2 2.4 2.7 3.3 3.3 3.6 0.5 0.6 1.1 1.0 1.1 1.6 2.2 2.4 2.8 0.7 0.9 1.5 1.4 1.6 2.1 3.1 3.3 3.9 1.0 1.2 2.0 1.9 2.1 2.9 4.2 4.4 5.2 213 213 313 333 333 333 433 433 433 213 213 313 333 333 333 433 433 433 213 213 313 333 333 333 433 433 433 8 8 8 8 8 8 9 9 9 8 8 8 8 8 9 9 9 9 8 8 9 9 9 9 9 9 9 TL3 TL3 TL4 TL4 TL4 TL7 TL3 TL3 TL5 TL3 TL4 TL7 TL7 TL7 TL5 TL5 TL5 TL8 TL7 TL7 TL5 TL5 TL5 TL5 TL8 TL8 TL8 Reaction Intensity (1,000 btu/ft2/min) 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 4.3 4.3 4.3 4.3 4.3 4.3 4.3 4.3 4.3 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 Flame Length (ft) 1.0 1.2 1.5 1.4 1.5 1.8 2.0 2.1 2.3 1.3 1.5 1.9 1.8 1.9 2.3 2.9 2.9 3.0 1.6 1.8 2.4 2.2 2.3 2.8 3.4 3.5 3.6 Rate of Spread (ft/min) 0.4 0.5 0.9 0.7 0.8 1.2 1.6 1.7 2.1 0.5 0.7 1.2 1.0 1.2 1.7 2.7 2.8 3.0 0.7 0.9 1.6 1.4 1.6 2.2 3.5 3.6 3.9 FCCS Fire Potentials 212 212 312 312 312 312 322 322 322 212 212 312 312 312 312 322 322 322 212 212 312 312 312 312 322 322 322 Crosswalk – FBPS FMs 8 8 8 8 8 8 9 9 9 8 8 8 8 8 9 9 9 9 8 8 9 9 9 9 9 9 9 Crosswalk – Standard FMs TL3 TL3 TL7 TL3 TL4 TL7 TL3 TL3 TL5 TL3 TL7 TL7 TL7 TL7 TL5 TL5 TL8 TL8 TL7 TL7 TL5 TL5 TL5 TL5 TL8 TL8 TL8 Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 18 Lake Tahoe National Forest Pathways Handbook Fuelbed LT083 Fuelbed LT082 Jeffrey pine – white fir fuelbed FCCS Outputs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario Windspeed mph 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 Slope % 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 5.2 5.2 5.2 5.2 5.2 5.2 5.2 5.2 5.2 0.6 0.7 0.9 1.8 1.8 1.9 3.2 3.2 3.2 1.0 1.1 1.4 3.0 3.0 3.1 5.2 5.2 5.3 1.2 1.4 1.7 3.6 3.6 3.7 6.2 6.2 6.3 0.1 0.2 0.2 1.2 1.2 1.3 3.9 3.9 4.0 0.2 0.3 0.5 2.3 2.4 2.6 7.8 7.8 8.0 0.3 0.4 0.6 3.0 3.1 3.3 10.0 10.1 10.3 222 222 222 332 332 432 632 632 632 222 222 222 332 332 432 632 632 632 222 222 222 332 332 432 632 632 632 8 8 8 8 8 8 9 9 9 8 8 8 9 9 9 10 10 10 8 8 8 9 9 9 12 12 12 TL3 TL3 TL3 TL7 TL7 TL7 TL8 TL8 TL8 TL3 TL3 TL3 TL8 TL8 TL8 TU2 TU2 TU2 TL3 TL3 TL7 TL8 TL8 TL8 SB2 SB2 SB3 Reaction Intensity (1,000 btu/ft2/min) 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 Flame Length (ft) 1.5 1.7 2.1 2.3 2.3 2.5 3.9 3.9 4.0 2.1 2.3 2.8 3.8 3.8 4.0 6.4 6.4 6.6 2.5 2.8 3.4 4.7 4.7 5.0 8.0 8.0 8.2 Rate of Spread (ft/min) 0.9 1.1 1.7 2.1 2.2 2.5 6.7 6.8 7.1 1.2 1.5 2.4 4.4 4.6 5.2 14.1 14.3 14.9 1.6 2.0 3.2 6.2 6.5 7.3 19.8 20.1 21.0 FCCS Fire Potentials 322 322 332 432 432 532 842 842 842 322 322 332 432 432 532 842 842 842 322 322 332 432 432 532 842 842 842 Crosswalk – FBPS FMs 8 8 9 9 9 9 9 9 10 9 9 9 9 9 10 12 12 12 9 9 9 10 10 10 12 13 13 Crosswalk – Standard FMs TL7 TL7 TL3 TL5 TL5 TL5 TL9 TL9 TU2 TL3 TL5 TL5 TL9 TL9 TU2 SB3 SB3 SB3 TL5 TL5 TL8 TU2 TU2 TU2 SB3 SB2 SB3 Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 19 Lake Tahoe National Forest Pathways Handbook Fuelbed LT087 Fuelbed LT084 Jeffrey pine – white fir fuelbed FCCS Outputs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario Windspeed mph 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 Slope % 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 5.2 5.2 5.2 5.2 5.2 5.2 5.2 5.2 5.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 2.4 2.7 3.4 3.2 3.4 3.9 4.7 4.7 5.0 3.0 3.3 4.2 4.0 4.2 4.9 6.5 6.6 6.8 3.8 4.2 5.3 5.1 5.3 6.1 8.5 8.6 8.8 1.3 1.6 2.6 2.3 2.6 3.7 5.4 5.5 6.3 1.8 2.2 3.6 3.2 3.6 5.1 9.5 9.7 10.3 2.4 3.0 4.9 4.7 4.9 6.8 14.0 14.3 15.2 314 414 414 434 434 534 644 644 644 314 414 414 434 434 534 644 644 644 314 414 414 434 434 534 644 644 644 9 9 9 9 9 9 10 10 10 9 9 10 9 10 10 12 12 12 9 10 10 10 10 12 13 13 13 TL5 TL5 TL8 TL8 TL8 TL9 TU2 TU2 TU2 TL8 TL8 TU2 TL9 TU2 TU2 SB3 SB3 SB3 TL9 TU2 TU2 TU2 TU2 SB2 SB3 SB3 SB3 Reaction Intensity (1,000 btu/ft2/min) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 Flame Length (ft) 1.2 1.4 1.7 1.6 1.7 2.0 2.3 2.4 2.6 1.6 1.8 2.2 2.1 2.2 2.6 3.0 3.1 3.4 2.0 2.2 2.8 2.6 2.8 3.2 3.7 3.8 4.2 Rate of Spread (ft/min) 1.2 1.5 2.5 2.2 2.5 3.5 4.8 5.1 6.2 1.7 2.1 3.5 3.1 3.5 4.9 6.7 7.1 8.5 2.3 2.8 4.7 4.2 4.7 6.6 9.0 9.6 11.4 FCCS Fire Potentials 317 317 417 437 437 437 547 547 647 317 317 417 437 437 437 547 547 647 317 317 417 437 437 437 547 547 647 Crosswalk – FBPS FMs 8 8 8 8 8 9 9 9 9 8 8 9 9 9 9 9 9 9 8 9 9 9 9 9 9 9 10 Crosswalk – Standard FMs TL4 TL4 TU1 TL7 TU1 TL3 TL6 TL6 TL6 TL7 TL7 TL6 TL3 TL6 TL6 TL8 TL8 TU2 TL7 TL5 TL6 TL6 TL6 TL8 TU2 TL9 TU4 Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 20 Lake Tahoe National Forest Pathways Handbook 2. Red fir pathways 21 Lake Tahoe National Forest Pathways Handbook 2. Red fir fuelbeds FuelbedID Age class Harvest / (yr) fuel treatment Change agent LT021 0-10 None Wildfire LT022 10-25 None None LT023 25-50 None None LT024 50-80 None None LT025 50-80 PCT, pile burn None LT026 50-80 PCT, pile (no burn) None LT027 80-120 None LT028 80-120 LT029 80-120 None None LT030 80-120 None None Select cut, Rx fire, pile burn None Wildfire Fuelbed name / description Dry red fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established less than 10 years ago following stand-replacement wildfire with no salvage, resulting in a shrubland with snags and less than 10% cover of live overstory trees. Dry red fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 10 to 25 years ago following stand-replacement wildfire with no subsequent management. Seedlings and saplings have established at low density and there is a minor component of defoliators but not significant enough to consider a change agent. Dry red fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 25 to 50 years ago following stand-replacement wildfire and has had no subsequent management. Dry red fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 50 to 80 years ago following stand-replacement wildfire and has had no subsequent management. There are defoliating insects present but not enough to consider a change agent. Dry red fir forest. Occurs at middle elevations in the Lake Tahoe Basin. Established 50 to 80 years ago following stand-replacement wildfire. Stand had a recent precommercial thin with woody fuels reduced by piling and burning. Dry red fir forest. Occurs at middle elevations in the Lake Tahoe Basin. Established 50 to 80 years ago following stand-replacement wildfire. Stand has had a recent precommercial thin with woody fuels piled but not burned. Dry red fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 80 to 120 years ago following stand-replacement wildfire and has had no subsequent management. Dry red fir forest. Occurs at middle elevation in the Lake Tahoe Basin. Established 80 to 120 years ago following stand-replacement wildfire. Stand may have had a precommercial thin during the years 25-50 and has had a recent low intensity wildfire or prescribed underburn followed by a select tree harvest with woody fuels piled and burned. Dry red fir forest. Occurs at middle elevations in the Lake Tahoe Basin. Established 80 to 120 years ago following stand-replacement wildfire. Stand was precommercially thinned with woody fuels piled and burned during the years 25 to 50 and has had no subsequent management. Dry red fir forest. Occurs at middle elevations in the Lake Tahoe Basin. Established 80 to 120 years ago following stand-replacement wildfire. Stand was precommercially thinned with woody fuels piled but not burned in years 25 to 50 and has had no subsequent management. 22 Lake Tahoe National Forest Pathways Handbook FuelbedID Age class Harvest / (yr) fuel treatment Change agent Select cut, pile (no burn) None None None LT031 80-120 LT032 120+ LT033 120+ LT034 120+ Select cut, pile (no burn) None LT035 120+ None None LT036 120+ LT086 80-120 LT089 120+ Select cut, Rx fire, pile burn Wildfire None None Select cut, Mastication None None None Fuelbed name / description Dry red fir forest. Occurs at middle elevations in the Lake Tahoe Basin. Established 80 to 120 years ago following stand-replacement wildfire. Stand was precommercially thinned with woody fuels piled and burned in years 25 to 50. Recent select tree harvest with woody fuels piled but not burned. Dry red fir forest. Established over 120 years ago following stand-replacement wildfire and has had no subsequent management. Stand has some insect damage. Dry red fir forest. Established over 120 years ago following stand-replacement wildfire. Stand has dense canopy and medium woody fuel load. Stand was precommercially thinned and selectively harvested in the past with woody fuels piled and burned. Recent prescribed underburn or low intensity wildfire followed by select tree harvest with woody fuels reduced by piling and burning. Some examples have developed relatively dense understories of red fir and stand-replacement fires are more common. Dry red fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Stand had previous select tree harvest with woody fuels piled and burned. Recent select tree harvest with woody fuels piled but not burned. Some examples have developed relatively dense understories of red fir and stand-replacement fires are more common. Dry red fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Stand was thinned and selectively harvested in the past with woody fuels piled but has had no recent management. Some recent insect damage, but not significant enough to consider a change agent. Dry red fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Stand had select tree harvest with woody fuels piled and burned in the 50 to 80 year range, but has had no recent management. Some recent insect damage, but not significant enough to consider a change agent. Dry red fir forest. Occurs at middle elevations in the Lake Tahoe Basin. Established 80 to 120 years ago following stand-replacement wildfire. Stand was precommercially thinned with woody fuels piled and burned in years 25 to 50. Recent select tree, cut to length harvest with mastication of logging slash, shrubs and small trees. Dry red fir forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Stand was thinned and selectively harvested in the past with woody fuels masticated but has had no recent management. Some recent insect damage, but not significant enough to consider a change agent. 23 Lake Tahoe National Forest Pathways Handbook 24 Lake Tahoe National Forest Pathways Handbook 2. Red fir fuelbed FCCS outputs Red fir fuelbed FCCS Outputs Fuelbed LT022 Fuelbed LT021 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 5.9 5.9 5.9 5.9 5.9 5.9 5.9 5.9 5.9 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 1.5 1.7 2.1 3.0 3.0 3.1 5.2 5.2 5.3 2.1 2.3 2.9 4.9 4.9 5.1 8.5 8.5 8.6 2.5 2.8 3.6 5.9 5.9 6.1 10.2 10.2 10.3 0.8 1.0 1.7 3.6 3.7 3.9 11.9 11.9 12.2 1.1 1.4 2.4 7.1 7.3 7.7 23.6 23.7 24.2 1.5 1.9 3.2 9.5 9.7 10.3 31.5 31.7 32.3 315 315 315 515 515 625 935 935 935 315 315 315 515 515 625 935 935 935 315 315 315 515 515 625 935 935 935 8 8 9 9 9 9 10 10 10 9 9 9 10 10 10 13 13 13 9 9 9 10 10 12 5 5 5 TL7 TL7 TL5 TL8 TL8 TL8 TU4 TU4 TU4 TL3 TL5 TL8 TU2 TU2 TU2 SB3 SB3 SB3 TL5 TL5 TL8 TU5 TU5 SB2 SH7 SH7 SH7 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 0.5 0.5 0.7 1.3 1.4 1.4 2.3 2.3 2.4 0.8 0.8 1.0 2.3 2.3 2.3 3.9 3.9 3.9 0.9 1.0 1.2 2.7 2.7 2.7 4.6 4.6 4.7 0.2 0.2 0.4 1.8 1.8 1.9 6.0 6.1 6.1 0.4 0.4 0.6 3.7 3.7 3.9 12.2 12.2 12.3 0.5 0.5 0.8 4.8 4.8 5.0 15.7 15.8 16.0 229 229 229 439 439 439 759 759 759 229 229 229 439 439 439 759 759 759 229 229 229 439 439 439 759 759 759 8 8 8 8 8 8 9 9 9 8 8 8 9 9 9 6 6 6 8 8 8 9 9 9 6 6 6 TL1 TL3 TL3 TL4 TL4 TL4 TL6 TL6 TL6 TL3 TL3 TL3 TL6 TL6 TL6 SH2 SH2 SH2 TL3 TL3 TL3 TL6 TL6 TL6 SH4 SH4 SH4 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 25 Lake Tahoe National Forest Pathways Handbook Red fir fuelbed FCCS Outputs Fuelbed LT024 Fuelbed LT023 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1.6 1.8 2.2 2.1 2.2 2.6 3.6 3.6 3.7 2.0 2.2 2.8 2.9 3.0 3.2 4.9 4.9 5.0 2.4 2.7 3.5 3.7 3.8 4.0 6.2 6.3 6.4 1.1 1.4 2.4 2.1 2.2 3.2 6.6 6.7 7.0 1.5 1.9 3.3 3.5 3.7 4.4 10.9 11.0 11.6 2.0 2.6 4.4 5.0 5.3 6.0 15.6 15.8 16.6 329 329 439 479 479 479 799 799 799 329 329 439 479 479 479 799 799 799 329 329 439 479 479 479 799 799 799 8 8 9 9 9 9 9 9 9 8 9 9 9 9 9 10 10 10 9 9 9 9 9 10 12 12 12 TL7 TL7 TL5 TL5 TL5 TL5 TL8 TL8 TL8 TL7 TL5 TL5 TL8 TL8 TL8 TU4 TU4 TU4 TL5 TL5 TL8 TL8 TL9 TU2 SB3 SB3 SB3 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 1.5 1.7 2.1 1.9 2.1 2.4 3.2 3.2 3.3 1.9 2.1 2.7 2.6 2.7 3.1 4.4 4.4 4.5 2.3 2.6 3.3 3.3 3.4 3.8 5.5 5.6 5.7 1.1 1.4 2.4 1.9 2.2 3.2 5.9 6.0 6.3 1.5 1.9 3.3 3.1 3.3 4.4 9.6 9.8 10.3 2.0 2.6 4.4 4.4 4.6 6.0 13.5 13.7 14.4 317 317 417 457 457 457 667 667 667 317 317 417 457 457 457 667 667 667 317 317 417 457 457 457 667 667 667 8 8 9 8 9 9 9 9 9 8 9 9 9 9 9 10 10 10 9 9 9 9 9 9 10 10 10 TL4 TL7 TL5 TL7 TL3 TL5 TL8 TL8 TL8 TL7 TL3 TL5 TL5 TL5 TL8 TU4 TU4 TU4 TL5 TL5 TL8 TL8 TL8 TL9 TU3 TU3 TU3 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 26 Lake Tahoe National Forest Pathways Handbook Red fir fuelbed FCCS Outputs Fuelbed LT026 Fuelbed LT025 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 0.6 0.7 0.8 0.8 0.8 1.0 1.1 1.2 1.3 0.8 0.9 1.1 1.1 1.1 1.3 1.7 1.7 1.7 1.0 1.1 1.4 1.3 1.4 1.6 2.0 2.0 2.1 0.3 0.4 0.7 0.6 0.7 1.0 1.4 1.5 1.8 0.5 0.6 1.0 0.9 1.0 1.4 2.5 2.5 2.6 0.6 0.8 1.4 1.2 1.4 1.9 3.2 3.2 3.4 225 225 225 245 245 245 355 355 355 225 225 225 245 245 245 355 355 355 225 225 225 245 245 245 355 355 355 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL4 TL4 TL3 TL3 TL3 TL3 TL3 TL4 TU1 TU1 TU1 TL3 TL3 TL4 TL4 TL4 TL7 TL3 TL3 TL3 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 2.3 2.6 3.3 3.2 3.2 3.8 5.3 5.4 5.5 2.9 3.2 4.2 4.4 4.4 4.8 7.3 7.4 7.5 3.6 4.0 5.2 5.5 5.6 6.0 9.2 9.3 9.5 1.4 1.8 3.0 2.8 2.9 4.1 8.5 8.6 9.1 1.9 2.4 4.2 4.6 4.8 5.6 14.1 14.3 15.0 2.6 3.3 5.6 6.4 6.6 7.6 19.5 19.8 20.7 319 419 419 459 459 559 869 869 869 319 419 419 459 459 559 869 869 869 319 419 419 459 459 559 869 869 869 9 9 9 9 9 9 10 10 10 9 9 10 10 10 10 12 12 12 9 10 10 10 10 10 13 13 13 TL5 TL5 TL8 TL8 TL8 TL9 TU2 TU4 TU5 TL8 TL8 TU2 TU2 TU2 TU2 SB3 SB3 SB3 TL8 TU2 TU2 TU5 TU5 TU5 SB3 SB3 SB3 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 27 Lake Tahoe National Forest Pathways Handbook Red fir fuelbed FCCS Outputs Fuelbed LT028 Fuelbed LT027 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 1.5 1.7 2.3 2.2 2.3 2.6 3.8 3.8 3.9 1.9 2.2 2.9 3.2 3.2 3.4 5.4 5.4 5.5 2.4 2.7 3.6 4.0 4.1 4.4 6.9 6.9 7.0 1.1 1.5 2.8 2.7 2.9 3.7 8.7 8.8 9.2 1.6 2.1 3.9 4.8 5.0 5.6 15.1 15.3 16.0 2.1 2.8 5.2 6.8 7.1 8.1 21.7 21.9 22.9 319 319 419 459 459 559 869 869 869 319 319 419 459 459 559 869 869 869 319 319 419 459 459 559 869 869 869 8 8 9 9 9 9 9 9 9 8 9 9 9 9 9 10 10 10 9 9 9 10 10 10 5 5 5 TL7 TL7 TL5 TL5 TL5 TL6 TL9 TL9 TL9 TL7 TL5 TL6 TL8 TL8 TL8 TU4 TU4 TU3 TL5 TL5 TL8 TU2 TU2 TU2 TU5 TU5 TU5 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 0.5 0.6 0.8 0.8 0.8 0.9 1.3 1.3 1.3 0.7 0.8 1.1 1.2 1.2 1.3 2.0 2.0 2.1 0.9 1.0 1.3 1.5 1.5 1.6 2.4 2.5 2.5 0.4 0.5 0.9 0.8 0.9 1.3 2.5 2.6 2.7 0.5 0.7 1.2 1.6 1.6 1.8 4.9 5.0 5.2 0.7 0.9 1.7 2.1 2.2 2.5 6.6 6.6 6.9 214 214 214 334 334 334 444 444 544 214 214 214 334 334 334 444 444 544 214 214 214 334 334 334 444 444 544 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 8 8 8 8 8 8 9 9 9 TL3 TL3 TL3 TL3 TL3 TL3 TL4 TL4 TL4 TL3 TL3 TL3 TL4 TL4 TL4 TL3 TL3 TL3 TL3 TL3 TL4 TL4 TL4 TL7 TL6 TL6 TL6 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 28 Lake Tahoe National Forest Pathways Handbook Red fir fuelbed FCCS Outputs Fuelbed LT030 Fuelbed LT029 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 1.3 1.5 2.0 1.7 1.8 2.2 2.7 2.8 2.8 1.7 1.9 2.5 2.2 2.3 2.8 3.7 3.7 3.8 2.1 2.4 3.1 2.8 2.9 3.5 4.6 4.6 4.8 0.9 1.1 2.1 1.5 1.7 2.7 4.1 4.2 4.5 1.2 1.6 2.9 2.2 2.4 3.7 6.6 6.7 7.1 1.6 2.1 3.9 3.0 3.2 5.0 9.1 9.2 9.8 318 328 328 358 358 458 568 568 568 318 328 328 358 358 458 568 568 568 318 328 328 358 358 458 568 568 568 8 8 9 8 8 9 9 9 9 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 10 10 10 TL4 TL7 TL3 TL7 TL7 TL5 TL6 TL6 TL6 TL7 TL7 TL5 TL5 TL5 TL6 TL8 TL8 TL9 TL3 TL5 TL8 TL5 TL5 TL8 TU4 TU4 TU4 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 2.3 2.6 3.4 3.1 3.1 3.8 5.1 5.1 5.3 2.8 3.2 4.2 4.0 4.1 4.8 6.7 6.8 7.0 3.5 4.0 5.3 5.1 5.3 6.0 8.6 8.6 8.8 1.4 1.9 3.5 2.8 2.9 4.5 8.5 8.6 9.0 2.0 2.6 4.9 4.4 4.6 6.3 13.3 13.5 14.2 2.7 3.6 6.6 6.1 6.4 8.5 18.7 19.0 20.0 319 419 429 449 449 559 769 769 869 319 419 429 449 449 559 769 769 869 319 419 429 449 449 559 769 769 869 9 9 9 9 9 9 10 10 10 9 9 10 10 10 10 12 12 12 9 10 10 10 10 10 13 13 13 TL5 TL5 TL8 TL8 TL8 TL9 TU2 TU2 TU4 TL5 TL8 TU2 TU2 TU2 TU2 SB3 SB3 SB3 TL8 TU2 TU2 TU2 TU2 TU5 SB3 SB3 SB3 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 29 Lake Tahoe National Forest Pathways Handbook Red fir fuelbed FCCS Outputs Fuelbed LT032 Fuelbed LT031 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 1.2 1.4 1.8 1.7 1.7 2.0 2.8 2.9 2.9 1.5 1.7 2.2 2.4 2.5 2.6 4.0 4.0 4.1 1.9 2.1 2.8 3.0 3.1 3.3 5.0 5.1 5.2 0.7 0.8 1.5 1.4 1.4 2.0 4.1 4.2 4.5 0.9 1.2 2.0 2.4 2.5 2.9 7.2 7.3 7.7 1.2 1.6 2.7 3.3 3.5 4.0 10.0 10.2 10.8 217 317 317 337 337 337 547 547 647 217 317 317 337 337 337 547 547 647 217 317 317 337 337 337 547 547 647 8 8 8 8 8 9 9 9 9 8 8 9 9 9 9 9 10 10 8 9 9 9 9 9 10 10 10 TL3 TL4 TL7 TL7 TL7 TL3 TL6 TL6 TL8 TL7 TL7 TL5 TL5 TL5 TL5 TL9 TU2 TU2 TL7 TL5 TL5 TL8 TL8 TL8 TU4 TU4 TU4 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 2.2 2.5 3.3 3.2 3.2 3.8 5.4 5.4 5.5 2.7 3.1 4.2 4.3 4.3 4.7 7.2 7.2 7.4 3.4 3.9 5.2 5.4 5.5 5.9 9.2 9.3 9.4 1.5 2.0 3.8 3.4 3.5 4.9 10.6 10.7 11.2 2.1 2.8 5.2 5.5 5.7 6.7 17.1 17.3 18.1 2.9 3.8 7.0 7.8 8.1 9.2 24.4 24.7 25.8 319 419 519 559 559 559 869 869 969 319 419 519 559 559 559 869 869 969 319 419 519 559 559 559 869 869 969 9 9 9 9 9 9 10 10 10 9 9 10 10 10 10 12 12 12 9 9 10 10 10 10 13 13 13 TL5 TL5 TL8 TL8 TL8 TL9 TU4 TU4 TU5 TL5 TL8 TU2 TU2 TU2 TU2 SB3 SB3 SB3 TL8 TL9 TU2 TU5 TU5 TU5 SB3 SB3 SB3 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 30 Lake Tahoe National Forest Pathways Handbook Red fir fuelbed FCCS Outputs Fuelbed LT034 Fuelbed LT033 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 0.4 0.4 0.6 0.5 0.6 0.7 0.8 0.8 0.8 0.5 0.6 0.8 0.8 0.8 0.9 1.3 1.3 1.3 0.6 0.7 0.9 0.9 0.9 1.1 1.6 1.6 1.6 0.2 0.2 0.4 0.3 0.4 0.5 0.9 0.9 0.9 0.2 0.3 0.5 0.5 0.6 0.7 1.7 1.8 1.8 0.3 0.4 0.7 0.7 0.7 1.0 2.3 2.3 2.3 105 215 215 225 225 225 335 335 335 105 215 215 225 225 225 335 335 335 105 215 215 225 225 225 335 335 335 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 TL1 TL1 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL4 TL4 TL4 TL3 TL3 TL3 TL3 TL3 TL3 TL7 TL7 TL7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 1.5 1.7 2.2 2.0 2.1 2.5 3.0 3.0 3.2 1.9 2.1 2.7 2.5 2.7 3.1 4.2 4.2 4.4 2.4 2.6 3.4 3.2 3.3 3.9 5.3 5.4 5.5 1.0 1.2 2.1 1.7 2.0 2.9 4.4 4.4 4.9 1.3 1.7 2.9 2.5 2.8 4.0 7.5 7.6 8.1 1.8 2.3 3.9 3.5 3.7 5.4 10.5 10.7 11.3 319 319 319 339 339 439 559 659 659 319 319 319 339 339 439 559 659 659 319 319 319 339 339 439 559 659 659 8 8 9 8 9 9 9 9 9 8 9 9 9 9 9 10 10 10 9 9 9 9 9 9 10 10 10 TL7 TL7 TL5 TL7 TL3 TL5 TL8 TL8 TL8 TL7 TL3 TL5 TL5 TL5 TL8 TU2 TU2 TU2 TL5 TL5 TL8 TL8 TL8 TL9 TU4 TU4 TU3 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 31 Lake Tahoe National Forest Pathways Handbook Red fir fuelbed FCCS Outputs Fuelbed LT036 Fuelbed LT035 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1.6 1.8 2.3 2.1 2.3 2.7 3.0 3.1 3.4 2.1 2.3 2.9 2.7 2.8 3.4 3.9 3.9 4.3 2.6 2.9 3.7 3.3 3.5 4.2 4.9 4.9 5.3 1.2 1.5 2.6 2.1 2.4 3.5 4.4 4.7 5.8 1.6 2.1 3.6 2.9 3.3 4.8 6.6 6.7 8.0 2.2 2.8 4.8 3.9 4.5 6.5 9.0 9.2 10.8 319 319 419 349 449 459 559 559 669 319 319 419 349 449 459 559 559 669 319 319 419 349 449 459 559 559 669 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 9 9 9 9 9 10 10 10 10 TL7 TL7 TL5 TL3 TL5 TL6 TL8 TL8 TL8 TL3 TL5 TL8 TL5 TL5 TL8 TL9 TL9 TU2 TL5 TL5 TL8 TL8 TL8 TU2 TU4 TU4 TU4 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 1.9 2.1 2.7 2.5 2.6 3.1 3.5 3.6 4.0 2.4 2.7 3.4 3.1 3.3 3.9 4.4 4.6 5.0 3.0 3.3 4.2 3.9 4.1 4.9 5.5 5.7 6.2 1.5 1.9 3.3 2.8 3.2 4.6 5.9 6.3 7.7 2.1 2.7 4.6 3.8 4.4 6.3 8.1 8.7 10.6 2.9 3.6 6.2 5.1 5.9 8.5 11.0 11.7 14.3 316 316 416 456 456 556 666 666 766 316 316 416 456 456 556 666 666 766 316 316 416 456 456 556 666 666 766 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 10 10 9 9 10 9 10 10 10 10 12 TL7 TL3 TL5 TL5 TL5 TL8 TL8 TL8 TL9 TL5 TL5 TL8 TL8 TL8 TL9 TU2 TU4 TU4 TL8 TL8 TU2 TL9 TU2 TU2 TU5 TU3 SB3 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 32 Lake Tahoe National Forest Pathways Handbook Red fir fuelbed FCCS Outputs Fuelbed LT089 Fuelbed LT086 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 1.6 1.8 2.4 3.3 3.3 3.6 5.5 5.5 5.7 2.0 2.3 3.0 4.4 4.5 4.8 7.4 7.4 7.6 2.6 2.9 3.7 5.6 5.7 6.1 9.5 9.5 9.7 0.7 0.8 1.5 2.9 3.1 3.5 9.1 9.2 9.7 0.9 1.2 2.0 4.7 5.0 5.7 14.7 14.9 15.6 1.3 1.6 2.7 6.8 7.1 8.2 21.0 21.3 22.4 317 317 317 447 447 547 857 857 857 317 317 317 447 447 547 857 857 857 317 317 317 447 447 547 857 857 857 8 8 9 9 9 9 10 10 10 9 9 9 10 10 10 12 12 12 9 9 9 10 10 12 13 13 13 TL7 TL7 TL5 TL8 TL8 TL8 TU5 TU5 TU5 TL3 TL5 TL8 TU2 TU2 TU2 SB3 SB3 SB3 TL5 TL5 TL8 TU5 TU5 SB2 SB3 SB3 SB3 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 5.2 5.2 5.2 5.2 5.2 5.2 5.2 5.2 5.2 2.3 2.5 3.3 3.5 3.6 3.9 5.9 5.9 6.1 2.8 3.2 4.0 4.6 4.7 5.0 7.7 7.8 7.9 3.5 3.9 5.1 5.8 6.0 6.4 9.8 9.8 10.1 1.2 1.5 2.6 3.1 3.2 3.8 9.5 9.6 10.1 1.6 2.1 3.6 4.7 5.0 5.7 14.5 14.7 15.5 2.2 2.8 4.8 6.6 6.9 8.0 20.2 20.5 21.6 318 418 428 458 458 558 868 868 868 318 418 428 458 458 558 868 868 868 318 418 428 458 458 558 868 868 868 9 9 9 9 9 9 10 10 12 9 9 10 10 10 10 12 12 12 9 9 10 10 10 12 13 13 13 TL5 TL5 TL8 TL8 TL8 TL9 TU5 TU5 SB2 TL5 TL8 TU2 TU2 TU2 TU2 SB3 SB3 SB3 TL8 TL9 TU2 TU5 TU5 SB3 SB3 SB3 SB3 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 33 Lake Tahoe National Forest Pathways Handbook 3. Wet lodgepole pine pathways 34 Lake Tahoe National Forest Pathways Handbook 3. Wet lodgepole pine fuelbeds Age class Harvest / FuelbedID (yr) fuel treatment LT037 0-10 LT038 0-10 LT039 10-20 LT040 20-40 LT041 20-40 LT042 40-80 LT043 40-80 LT044 80+ Change agent Fuelbed name / description Moist lodgepole pine forest. Occurs on moist sites, often in topographic depressions, at all elevations of the Lake Tahoe Basin. Established less than 10 years ago following None Wildfire stand-replacement wildfire with no subsequent management. Moist lodgepole pine forest. Occurs on moist sites, often in topographic depressions, at all elevations of the Lake Tahoe Basin. Established less than 10 years ago following Clearcut, Rx fire None clearcut harvest and prescribed fire to reduce woody fuel loads. Moist lodgepole pine forest. Occurs on moist sites, often in topographic depressions, at all elevations of the Lake Tahoe Basin. Established 10 to 20 years ago following a None None stand-replacement wildfire and has had no subsequent management. Moist lodgepole pine forest. Occurs on moist sites, often in topographic depressions, at all elevations of the Lake Tahoe Basin. Established 20 to 40 years ago following a None None stand-replacement wildfire and has had no subsequent management. Moist lodgepole pine forest. Occurs on moist sites, often in topographic depressions, at all elevations of the Lake Tahoe Basin. Established 20 to 40 years ago following clearcut harvest and prescribed fire. Stand was recently precommercially thinned with PCT None no woody fuel reduction treatment. Moist lodgepole pine forest. Occurs on moist sites, often in topographic depressions, at all elevations of the Lake Tahoe Basin. Established 40 to 80 years ago following None None stand-replacement wildfire and has had no subsequent management. Moist lodgepole pine forest. Occurs on moist sites, often in topographic depressions, at all elevations of the Lake Tahoe Basin. Established 40 to 80 years ago following clearcut harvest and was precommercially thinned in the past, but has had no recent None None management. Moist lodgepole pine forest. Occurs on moist sites, often in topographic depressions, at all elevations of the Lake Tahoe Basin. Established over 80 years ago following standreplacement wildfire and has had no subsequent management. Stand attacked by pine Insects and bark beetles in the last 10 years. Many standing snags are present and are beginning None Disease to fall, adding to woody fuel accumulations. 35 Lake Tahoe National Forest Pathways Handbook 3. Wet lodgepole pine fuelbed FCCS outputs Wet lodgepole pine fuelbed FCCS Outputs Fuelbed LT038 Fuelbed LT037 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0.7 0.8 1.1 0.9 1.0 1.2 1.3 1.3 1.5 0.9 1.0 1.3 1.1 1.2 1.5 1.6 1.7 1.9 1.1 1.3 1.7 1.4 1.5 1.9 2.0 2.1 2.3 0.4 0.6 1.1 0.8 0.9 1.4 1.6 1.7 2.2 0.6 0.8 1.5 1.0 1.3 1.9 2.2 2.4 3.1 0.8 1.1 2.0 1.4 1.7 2.6 3.1 3.2 4.1 222 222 222 232 232 332 342 342 342 222 222 222 232 232 332 342 342 342 222 222 222 232 232 332 342 342 342 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 TL3 TL3 TL3 TL3 TL3 TL4 TL4 TL4 TL4 TL3 TL3 TL4 TL3 TL4 TL7 TL7 TL7 TU1 TL3 TL4 TL7 TL4 TL7 TU1 TL3 TL3 TL6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.4 0.5 0.6 0.5 0.6 0.7 0.8 0.8 0.9 0.5 0.6 0.8 0.7 0.7 0.9 0.9 1.0 1.1 0.6 0.7 1.0 0.8 0.9 1.1 1.2 1.2 1.4 0.4 0.6 1.1 0.8 0.9 1.4 1.7 1.8 2.3 0.6 0.8 1.5 1.1 1.3 2.0 2.3 2.5 3.2 0.8 1.1 2.0 1.5 1.8 2.7 3.2 3.4 4.4 211 211 211 231 231 331 331 331 431 211 211 211 231 231 331 331 331 431 211 211 211 231 231 331 331 331 431 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 TL1 TL1 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL4 TL4 TL4 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 36 Lake Tahoe National Forest Pathways Handbook Wet lodgepole pine fuelbed FCCS Outputs Fuelbed LT040 Fuelbed LT039 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 0.9 1.1 1.4 1.2 1.3 1.6 1.6 1.7 1.9 1.1 1.3 1.7 1.5 1.6 2.0 2.0 2.1 2.4 1.4 1.6 2.2 1.8 2.0 2.4 2.6 2.7 3.0 0.6 0.8 1.5 1.1 1.3 2.0 2.2 2.4 3.1 0.9 1.1 2.1 1.5 1.8 2.7 3.0 3.3 4.3 1.2 1.5 2.9 2.0 2.4 3.7 4.1 4.5 5.8 223 223 323 243 343 343 343 443 443 223 223 323 243 343 343 343 443 443 223 223 323 243 343 343 343 443 443 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 8 8 9 8 8 9 9 9 9 TL3 TL3 TL4 TL4 TL4 TL7 TL7 TL7 TU1 TL3 TL4 TL7 TL4 TL7 TU1 TL3 TL5 TL6 TL4 TL7 TL5 TL7 TL7 TL6 TL6 TL6 TL8 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.0 1.2 1.5 1.3 1.4 1.7 1.8 1.9 2.1 1.3 1.5 1.9 1.6 1.8 2.2 2.3 2.4 2.7 1.6 1.8 2.4 2.0 2.2 2.7 2.8 3.0 3.3 1.0 1.3 2.4 1.6 2.0 3.0 3.4 3.7 4.8 1.3 1.8 3.2 2.3 2.7 4.2 4.6 5.1 6.6 1.8 2.4 4.4 3.0 3.6 5.6 6.3 6.9 8.9 224 324 424 344 344 444 454 554 554 224 324 424 344 344 444 454 554 554 224 324 424 344 344 444 454 554 554 8 8 8 8 8 8 8 8 9 8 8 8 8 8 9 9 9 9 8 8 9 9 9 9 9 9 9 TL3 TL4 TL7 TL4 TL4 TU1 TL5 TL5 TL6 TL4 TL4 TU1 TL7 TU1 TL6 TL6 TL6 TL6 TL7 TL7 TL6 TL3 TL6 TL6 TL6 TL8 TU2 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 37 Lake Tahoe National Forest Pathways Handbook Wet lodgepole pine fuelbed FCCS Outputs Fuelbed LT042 Fuelbed LT041 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 1.6 1.9 2.5 2.3 2.4 2.8 3.9 3.9 4.0 2.0 2.3 3.0 3.1 3.2 3.5 5.2 5.3 5.4 2.5 2.9 3.8 4.2 4.3 4.6 6.9 7.0 7.2 0.6 0.8 1.5 1.4 1.4 1.9 4.1 4.2 4.5 0.9 1.1 2.1 2.2 2.4 2.8 6.8 7.0 7.4 1.2 1.5 2.9 3.4 3.6 4.4 10.5 10.7 11.4 323 323 333 433 433 443 553 553 553 323 323 333 433 433 443 553 553 553 323 323 333 433 433 443 553 553 553 8 8 9 9 9 9 9 9 10 9 9 9 9 9 9 10 10 10 9 9 9 10 10 10 12 12 12 TL7 TL7 TL5 TL5 TL5 TL5 TL9 TL9 TU2 TL3 TL5 TL8 TL8 TL8 TL8 TU2 TU2 TU5 TL5 TL8 TL9 TU2 TU2 TU2 SB3 SB3 SB3 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.2 0.2 0.2 0.4 0.4 0.4 0.7 0.7 0.7 0.2 0.2 0.2 0.6 0.6 0.6 1.0 1.0 1.0 0.3 0.3 0.3 0.8 0.8 0.8 1.4 1.4 1.4 0.0 0.0 0.0 0.2 0.2 0.2 0.6 0.6 0.6 0.0 0.0 0.0 0.3 0.3 0.3 1.1 1.1 1.1 0.1 0.1 0.1 0.5 0.5 0.5 1.7 1.7 1.7 105 105 105 235 235 235 245 245 245 105 105 105 235 235 235 245 245 245 105 105 105 235 235 235 245 245 245 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 TL1 TL1 TL1 TL1 TL1 TL1 TL3 TL3 TL3 TL1 TL1 TL1 TL3 TL3 TL3 TL3 TL3 TL3 TL1 TL1 TL1 TL3 TL3 TL3 TL4 TL4 TL4 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 38 Lake Tahoe National Forest Pathways Handbook Wet lodgepole pine fuelbed FCCS Outputs Fuelbed LT044 Fuelbed LT043 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.1 1.2 1.6 1.4 1.5 1.8 1.9 2.0 2.3 1.3 1.5 2.0 1.7 1.9 2.3 2.4 2.5 2.8 1.7 1.9 2.5 2.1 2.3 2.8 3.0 3.1 3.5 0.9 1.1 2.1 1.5 1.8 2.7 3.0 3.3 4.3 1.2 1.6 2.9 2.0 2.4 3.7 4.2 4.6 5.9 1.6 2.1 3.9 2.7 3.3 5.1 5.7 6.2 8.0 214 314 314 334 334 434 444 444 544 214 314 314 334 334 434 444 444 544 214 314 314 334 334 434 444 444 544 8 8 8 8 8 8 8 9 9 8 8 9 8 8 9 9 9 9 8 8 9 9 9 9 9 9 9 TL3 TL4 TL7 TL4 TL4 TU1 TU1 TL3 TL6 TL4 TL7 TL3 TL7 TL7 TL6 TL6 TL6 TL6 TL7 TL7 TL6 TL5 TL5 TL6 TL8 TL8 TU2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.0 1.2 1.6 1.3 1.4 1.8 1.8 1.9 2.2 1.3 1.5 1.9 1.6 1.8 2.2 2.3 2.4 2.7 1.6 1.8 2.4 2.0 2.2 2.7 2.8 3.0 3.3 1.1 1.4 2.6 1.8 2.1 3.3 3.7 4.0 5.2 1.5 1.9 3.6 2.5 2.9 4.6 5.0 5.5 7.2 2.0 2.6 4.8 3.3 4.0 6.2 6.8 7.5 9.7 218 318 418 338 338 438 438 538 538 218 318 418 338 338 438 438 538 538 218 318 418 338 338 438 438 538 538 8 8 8 8 8 8 8 8 9 8 8 8 8 8 9 9 9 9 8 8 9 9 9 9 9 9 9 TL3 TL4 TU1 TL4 TL4 TL5 TL5 TL5 TL6 TL4 TL4 TL5 TL7 TU1 TL6 TL6 TL6 TL6 TL7 TU1 TL6 TL3 TL6 TL6 TL6 TL8 TU2 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 39 Lake Tahoe National Forest Pathways Handbook 4. Whitebark pine – Lodgepole pine pathways 40 Lake Tahoe National Forest Pathways Handbook 4. Whitebark pine – Lodgepole pine fuelbeds FuelbedID Age class Harvest / (yr) fuel treatment Change agent LT045 0-10 None Wildfire LT046 10-40 None None LT047 40-90 None None LT048 90-120 None None LT049 120+ None None LT050 120+ None None LT051 Dry site None None None Avalanche LT052 Fuelbed name / description Whitebark pine and lodgepole pine forest. Occurs at high elevations of the Lake Tahoe Basin. Established following stand-replacement wildfire less than 10 years ago. Dominated by tree regeneration including lodgepole pine and whitebark pine. Snags are present. Whitebark pine and lodgepole pine forest. Occurs at high elevations of the Lake Tahoe Basin. Dominated by dense lodgepole pine and whitebark pine seedlings and saplings. Established following stand-replacement wildfire 10 to 40 years ago with no recent disturbance or management. Whitebark pine and lodgepole pine forest. Occurs at high elevations of the Lake Tahoe Basin. Established 40 to 90 years ago following stand-replacement wildfire with no subsequent disturbance or management. Lodgepole pine and whitebark pine poles dominate the canopy and regeneration is continuing to establish. Natural woody fuel loadings with large woody debris decomposing. Whitebark pine and lodgepole pine forest. Occurs at high elevations of the Lake Tahoe Basin. Established 90 to 120 years ago following stand-replacement wildfire with no subsequent management or disturbance. Whitebark pine and lodgepole pine forest. Occurs at high elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire with no subsequent disturbance or management. This fuelbed represents a medium density,mature stand. Whitebark pine and lodgepole pine forest. Occurs at high elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire with no subsequent disturbance or management. This fuelbed represents a high density, mature stand. Dry whitebark pine and lodgepole pine forest. Occurs at high elevations of the Lake Tahoe Basin. Low density stands with natural woody fuel loads and no history of management. Trembling aspen forest established following avalanche in the subalpine zone. Occurs at high elevations of the Lake Tahoe Basin. 41 Lake Tahoe National Forest Pathways Handbook 4. Whitebark pine - Lodgepole pine fuelbed FCCS outputs Whitebark pine - Lodgepole pine fuelbed FCCS Outputs Fuelbed LT046 Fuelbed LT045 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 0.3 0.3 0.5 0.9 0.9 0.9 1.5 1.6 1.6 0.5 0.6 0.7 1.5 1.5 1.6 2.6 2.6 2.6 0.6 0.7 0.9 1.8 1.8 1.9 3.2 3.2 3.2 0.1 0.1 0.2 0.7 0.7 0.8 2.4 2.4 2.5 0.1 0.2 0.3 1.5 1.6 1.7 5.1 5.2 5.3 0.2 0.2 0.5 2.0 2.1 2.3 6.8 6.8 7.0 111 111 211 221 321 321 531 531 531 111 111 211 221 321 321 531 531 531 111 111 211 221 321 321 531 531 531 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 8 8 8 8 8 8 9 9 9 TL1 TL1 TL1 TL3 TL3 TL3 TL7 TL7 TL7 TL1 TL3 TL3 TL4 TL7 TL7 TL6 TL6 TL6 TL3 TL3 TL3 TL7 TL7 TL7 TL8 TL8 TL8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 1.2 1.4 1.9 1.7 1.8 2.1 2.7 2.7 2.8 1.6 1.8 2.4 2.4 2.5 2.8 4.2 4.2 4.3 2.0 2.3 3.0 3.0 3.1 3.5 5.2 5.2 5.3 0.8 1.1 2.0 1.5 1.8 2.7 4.6 4.6 4.8 1.1 1.5 2.7 2.8 2.9 3.7 8.9 9.0 9.4 1.5 2.0 3.7 3.7 3.9 5.0 12.1 12.2 12.7 325 325 325 345 345 445 655 655 655 325 325 325 345 345 445 655 655 655 325 325 325 345 345 445 655 655 655 8 8 8 8 8 9 9 9 9 8 8 9 9 9 9 10 10 10 8 9 9 9 9 9 10 10 10 TL3 TL4 TL7 TL7 TL7 TL5 TL6 TL6 TL6 TL7 TL7 TL5 TL5 TL5 TL6 TU4 TU4 TU4 TL7 TL5 TL8 TL8 TL8 TL8 TU4 TU4 TU4 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 42 Lake Tahoe National Forest Pathways Handbook Whitebark pine - Lodgepole pine fuelbed FCCS Outputs Fuelbed LT048 Fuelbed LT047 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 1.3 1.5 2.0 1.8 1.9 2.3 2.9 2.9 3.0 1.8 2.0 2.7 2.6 2.6 3.1 4.4 4.5 4.5 2.2 2.5 3.3 3.2 3.3 3.8 5.5 5.5 5.6 1.0 1.3 2.4 1.8 2.2 3.3 5.1 5.1 5.5 1.3 1.8 3.3 3.1 3.2 4.5 10.0 10.1 10.5 1.8 2.4 4.5 4.2 4.4 6.1 13.6 13.8 14.3 324 324 424 444 444 444 654 654 654 324 324 424 444 444 444 654 654 654 324 324 424 444 444 444 654 654 654 8 8 9 8 8 9 9 9 9 8 9 9 9 9 9 10 10 10 9 9 9 9 9 9 10 10 10 TL4 TL7 TL3 TL7 TL7 TL5 TL6 TL8 TL8 TL7 TL3 TL5 TL5 TL5 TL8 TU4 TU4 TU4 TL5 TL5 TL8 TL8 TL8 TL9 TU3 TU3 TU3 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 1.3 1.5 2.0 1.8 1.9 2.3 2.9 2.9 3.0 1.7 2.0 2.6 2.7 2.7 3.0 4.5 4.6 4.7 2.2 2.5 3.3 3.4 3.4 3.7 5.7 5.8 5.9 1.1 1.4 2.7 2.0 2.4 3.6 5.9 6.0 6.3 1.5 2.0 3.7 3.8 4.0 5.0 12.2 12.3 12.9 2.0 2.7 5.0 5.3 5.5 6.7 16.9 17.2 17.9 316 326 426 456 456 456 766 766 766 316 326 426 456 456 456 766 766 766 316 326 426 456 456 456 766 766 766 8 8 9 8 8 9 9 9 9 8 8 9 9 9 9 10 10 10 9 9 9 9 9 9 10 10 6 TL4 TL7 TL3 TL7 TL7 TL6 TL8 TL8 TL8 TL7 TL7 TL6 TL6 TL6 TL8 TU4 TU4 TU4 TL5 TL5 TL8 TL8 TL8 TL8 TU3 TU3 SH4 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 43 Lake Tahoe National Forest Pathways Handbook Whitebark pine - Lodgepole pine fuelbed FCCS Outputs Fuelbed LT050 Fuelbed LT049 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 1.1 1.3 1.7 1.5 1.7 2.0 2.6 2.6 2.6 1.6 1.8 2.4 2.8 2.9 3.0 4.8 4.9 4.9 1.9 2.2 2.9 3.6 3.6 3.8 6.2 6.2 6.3 1.2 1.6 3.0 2.4 2.8 4.2 7.2 7.3 7.6 1.7 2.3 4.2 6.0 6.2 6.9 19.5 19.7 20.4 2.3 3.1 5.7 8.8 9.1 10.1 28.5 28.8 29.8 317 317 427 557 557 557 967 967 967 317 317 427 557 557 557 967 967 967 317 317 427 557 557 557 967 967 967 8 8 8 8 8 8 9 9 9 8 8 9 9 9 9 6 6 6 8 9 9 9 9 9 5 5 5 TL3 TL4 TU1 TL7 TU1 TL5 TL6 TL6 TL6 TL7 TL7 TL6 TL6 TL6 TL8 SH4 SH4 SH4 TL7 TL5 TL8 TU2 TU2 TL9 TU5 TU5 TU5 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 1.4 1.6 2.2 2.1 2.1 2.5 3.6 3.6 3.7 1.9 2.2 2.9 3.4 3.5 3.7 5.9 5.9 6.0 2.3 2.7 3.6 4.3 4.4 4.6 7.4 7.4 7.5 1.2 1.6 3.0 2.9 3.0 4.1 9.2 9.3 9.7 1.7 2.3 4.2 6.3 6.5 7.2 20.2 20.4 21.1 2.3 3.1 5.7 8.6 8.9 9.9 27.7 28.0 29.0 328 328 428 558 558 558 968 968 968 328 328 428 558 558 558 968 968 968 328 328 428 558 558 558 968 968 968 8 8 9 9 9 9 9 9 9 8 9 9 9 9 9 6 6 5 9 9 9 10 10 10 5 5 5 TL4 TL7 TL5 TL3 TL5 TL6 TU2 TU2 TU2 TL7 TL5 TL6 TL8 TL8 TL8 SH4 SH4 TU5 TL5 TL5 TL8 TU2 TU4 TU4 TU5 TU5 TU5 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 44 Lake Tahoe National Forest Pathways Handbook Whitebark pine - Lodgepole pine fuelbed FCCS Outputs Fuelbed LT052 Fuelbed LT051 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 1.3 1.5 1.9 1.8 1.9 2.3 2.5 2.6 2.9 1.8 2.1 2.7 2.4 2.6 3.1 3.7 3.7 4.0 2.3 2.6 3.3 3.0 3.2 3.9 4.7 4.7 4.9 1.3 1.6 3.0 2.4 2.8 4.1 5.2 5.6 6.9 1.7 2.3 4.1 3.3 3.8 5.6 8.3 8.4 9.6 2.3 3.1 5.5 4.4 5.1 7.6 11.4 11.5 12.9 323 323 433 453 453 553 663 663 663 323 323 433 453 453 553 663 663 663 323 323 433 453 453 553 663 663 663 8 8 8 8 8 9 9 9 9 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 10 10 TL4 TL4 TU1 TL7 TU1 TL6 TL6 TL6 TL8 TL7 TL3 TL6 TL5 TL6 TL8 TU2 TU2 TL9 TL5 TL5 TL8 TL8 TL8 TL9 TU4 TU4 TU4 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 0.7 0.8 1.0 0.9 1.0 1.2 1.3 1.3 1.5 1.0 1.2 1.5 1.3 1.5 1.8 1.9 2.0 2.2 1.3 1.4 1.9 1.7 1.8 2.2 2.4 2.5 2.8 0.8 1.0 1.9 1.4 1.7 2.5 3.0 3.3 4.1 1.1 1.4 2.6 1.9 2.3 3.5 4.2 4.5 5.7 1.4 1.9 3.5 2.6 3.1 4.7 5.6 6.1 7.7 212 212 322 312 322 422 422 422 522 212 212 322 312 322 422 422 422 522 212 212 322 312 322 422 422 422 522 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 8 8 8 8 8 9 9 9 9 TL3 TL3 TL3 TL3 TL3 TL4 TL4 TL4 TL4 TL3 TL4 TU1 TL4 TL4 TL5 TL5 TL5 TL6 TL4 TL4 TL5 TU1 TU1 TL6 TL6 TL6 TL6 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 45 Lake Tahoe National Forest Pathways Handbook 5. Mountain hemlock pathways 46 Lake Tahoe National Forest Pathways Handbook 5. Mountain hemlock fuelbeds FuelbedID Age class Harvest / (yr) fuel treatment Change agent LT054 0-10 None Wildfire LT055 10-40 None None LT056 40-90 None None LT057 90-120 None None LT058 120+ None None LT059 120+ None None Fuelbed name / description Mountain hemlock subalpine forest. Occurs at high elevations of the Lake Tahoe Basin. Established less than 10 years ago following stand-replacement wildfire. Stands are dominated by tree regeneration (may include lodgepole pine, western white pine, red fir), shrubs and scattered snags. Mountain hemlock subalpine forest. Occurs at high elevations of the Lake Tahoe Basin. Established 10 to 40 years ago following stand-replacement wildfire with no subsequent management. Dominated by pine and mountain hemlock seedlings and saplings. Mountain hemlock subalpine forest. Occurs at high elevations of the Lake Tahoe Basin. Established 40 to 90 years ago following stand-replacement wildfire. Lodgepole pine and mountain hemlock dominate the canopy and regeneration is continuing to establish. Natural woody fuel loadings with large woody debris decomposing. Mountain hemlock subalpine forest. Occurs at high elevations of the Lake Tahoe Basin. Established 90 to 120 years ago following stand-replacement wildfire and has had no subsequent management. Mountain hemlock subalpine forest. Occurs at high elevations of the Lake Tahoe Basin. Medium density stand established over 120 years ago following stand-replacement wildfire with no subsequent management. Mountain hemlock subalpine forest. Occurs at high elevations of the Lake Tahoe Basin. High density stand established over 120 years ago following stand-replacement wildfire with no subsequent management. 47 Lake Tahoe National Forest Pathways Handbook 5. Mountain hemlock fuelbed FCCS outputs Mountain hemlock fuelbed FCCS Outputs Fuelbed LT055 Fuelbed LT054 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0.3 0.3 0.4 0.7 0.7 0.8 1.3 1.3 1.3 0.4 0.5 0.6 1.2 1.2 1.2 2.0 2.0 2.0 0.5 0.6 0.7 1.4 1.5 1.5 2.5 2.5 2.5 0.1 0.1 0.1 0.5 0.5 0.6 1.7 1.8 1.8 0.1 0.1 0.2 1.1 1.1 1.2 3.6 3.6 3.7 0.1 0.2 0.3 1.5 1.5 1.7 4.9 4.9 5.0 112 112 212 222 222 222 432 432 432 112 112 212 222 222 222 432 432 432 112 112 212 222 222 222 432 432 432 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 8 8 8 8 8 8 9 9 9 TL1 TL1 TL1 TL3 TL3 TL3 TL4 TL4 TL4 TL1 TL1 TL3 TL4 TL4 TL4 TL3 TL3 TL3 TL3 TL3 TL3 TL4 TL4 TL7 TL6 TL6 TL6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 1.2 1.3 1.7 1.6 1.7 2.0 2.5 2.6 2.6 1.5 1.7 2.1 2.2 2.2 2.5 3.7 3.7 3.8 1.9 2.1 2.7 2.7 2.8 3.1 4.7 4.7 4.8 0.8 1.0 1.6 1.5 1.7 2.3 4.1 4.1 4.3 1.1 1.4 2.3 2.4 2.4 3.2 7.5 7.6 7.9 1.5 1.8 3.1 3.3 3.4 4.3 10.4 10.5 10.9 219 319 319 349 349 449 559 659 659 219 319 319 349 349 449 559 659 659 219 319 319 349 349 449 559 659 659 8 8 8 8 8 8 9 9 9 8 8 9 9 9 9 9 9 9 8 9 9 9 9 9 10 10 10 TL3 TL4 TL7 TL7 TL7 TL7 TL6 TL6 TL6 TL7 TL7 TL5 TL5 TL5 TL5 TL8 TL8 TL9 TL7 TL3 TL5 TL5 TL5 TL8 TU4 TU4 TU4 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 48 Lake Tahoe National Forest Pathways Handbook Mountain hemlock fuelbed FCCS Outputs Fuelbed LT057 Fuelbed LT056 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 1.3 1.4 1.8 1.7 1.8 2.1 2.6 2.6 2.7 1.6 1.8 2.3 2.2 2.3 2.6 3.8 3.8 3.9 2.0 2.2 2.8 2.8 2.9 3.3 4.8 4.9 4.9 1.0 1.2 2.0 1.8 2.1 2.8 4.6 4.6 5.0 1.4 1.7 2.8 2.7 2.8 3.9 8.7 8.8 9.1 1.8 2.3 3.7 3.8 3.9 5.3 12.1 12.2 12.7 319 319 319 359 359 459 669 669 669 319 319 319 359 359 459 669 669 669 319 319 319 359 359 459 669 669 669 8 8 8 8 8 9 9 9 9 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 10 10 10 TL4 TL4 TL7 TL7 TL7 TL3 TL6 TL6 TL6 TL7 TL7 TL5 TL5 TL5 TL6 TL9 TL9 TL9 TL3 TL5 TL6 TL6 TL8 TL8 TU4 TU4 TU4 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.1 1.3 1.6 1.5 1.6 1.9 2.2 2.2 2.4 1.5 1.6 2.0 2.0 2.1 2.4 3.5 3.5 3.6 1.8 2.0 2.6 2.6 2.7 3.0 4.4 4.5 4.6 1.1 1.4 2.2 2.0 2.3 3.2 4.6 4.7 5.5 1.5 1.9 3.1 3.1 3.2 4.4 9.8 10.0 10.4 2.0 2.5 4.2 4.4 4.5 5.9 13.9 14.0 14.6 218 318 418 458 458 458 668 668 668 218 318 418 458 458 458 668 668 668 218 318 418 458 458 458 668 668 668 8 8 8 8 8 8 9 9 9 8 8 9 9 9 9 9 9 9 8 9 9 9 9 9 6 6 6 TL3 TL4 TL7 TL7 TL7 TU1 TL6 TL6 TL6 TL4 TL7 TL3 TL3 TL3 TL6 TU2 TU2 TU2 TL7 TL3 TL6 TL6 TL6 TL8 SH2 SH2 SH2 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 49 Lake Tahoe National Forest Pathways Handbook Mountain hemlock fuelbed FCCS Outputs Fuelbed LT059 Fuelbed LT058 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 0.9 1.0 1.3 1.2 1.3 1.5 1.7 1.8 2.0 1.2 1.3 1.7 1.6 1.7 2.0 2.7 2.8 2.8 1.5 1.6 2.1 2.1 2.1 2.5 3.5 3.5 3.6 1.2 1.6 2.7 2.3 2.6 3.7 4.9 5.2 6.4 1.7 2.2 3.7 3.4 3.6 5.1 10.6 10.8 11.3 2.3 2.9 5.0 4.9 5.1 6.9 15.3 15.5 16.3 319 319 419 459 459 559 779 779 779 319 319 419 459 459 559 779 779 779 319 319 419 459 459 559 779 779 779 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 11 11 11 8 8 9 9 9 9 6 6 6 TL3 TL3 TL4 TL4 TL4 TL5 TL5 TL5 TL5 TL4 TL4 TL5 TL5 TL5 TL5 SB1 SB1 SB1 TL4 TU1 TL3 TL3 TL6 TL6 SH2 SH2 SH2 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.3 1.4 1.8 1.7 1.8 2.1 2.9 2.9 3.0 1.6 1.8 2.3 2.5 2.5 2.7 4.2 4.2 4.3 2.0 2.2 2.9 3.2 3.2 3.4 5.4 5.4 5.5 1.2 1.6 2.7 2.4 2.5 3.6 7.6 7.7 8.1 1.7 2.2 3.7 4.4 4.5 5.1 13.7 13.9 14.5 2.3 2.9 5.0 6.2 6.5 7.4 19.6 19.9 20.7 319 319 419 459 459 559 769 769 869 319 319 419 459 459 559 769 769 869 319 319 419 459 459 559 769 769 869 8 8 8 8 8 9 9 9 9 8 8 9 9 9 9 6 6 6 8 9 9 9 9 9 6 6 6 TL4 TL4 TU1 TL7 TU1 TL3 TL8 TL8 TU2 TL7 TL7 TL6 TL6 TL6 TL6 SH2 SH2 SH2 TL7 TL5 TL6 TL8 TL8 TL8 SH4 SH4 SH4 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 50 Lake Tahoe National Forest Pathways Handbook 6. Mixed conifer pathways 51 Lake Tahoe National Forest Pathways Handbook 6. Mixed conifer fuelbeds FuelbedID Age class Harvest / Change (yr) fuel treatment agent LT060 0-7 None Wildfire LT061 7-25 None None LT062 25-50 None None LT063 50-80 None None LT064 80-120 None None LT065 120+ None None LT066 80-120 Select cut, RX Wildfire fire (ground) LT067 80-120 Select cut LT068 80-120 Select cut, pile & burn None LT069 80-120 Select cut, Pile (no burn) None LT070 120+ Select cut, RX fire None LT071 120+ Select cut None None Fuelbed name / description Mixed conifer forest. Occurs at middle elevations in the Lake Tahoe Basin. Established less than 7 years ago following stand-replacement wildfire with no salvage harvest. Stand is currently dominated by shrubs with 10% cover of trees. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 7 to 25 years ago following stand-replacement wildfire with no subsequent management. Stand is dominated by shrubs with seedlings and saplings in the canopy. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 25 to 50 years ago following stand-replacement wildfire with no subsequent management. High density stand of sapling and pole-sized mixed conifers. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 50 to 80 years ago following stand-replacement wildfire with no subsequent management. Medium density stand with moderate woody fuel loads. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 80 to 120 years ago following stand-replacement wildfire with no subsequent management. High density stand. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire with no subsequent management. High density stand. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 80 to 120 years ago following stand-replacement wildfire with no salvage harvest. Recent select tree harvest followed by prescribed fire or low intensity wildfire. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 80 to 120 years ago following stand-replacement wildfire. Recent select tree harvest with no fuel reduction treatment. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 80 to 120 years ago following stand-replacement wildfire. Recent select tree harvest with the logging slash piled and burned. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 80 to 120 years ago following stand-replacement wildfire. Recent select tree harvest with logging slash piled but not burned. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Recent select tree harvest with logging slash piled and burned or treated with prescribed fire. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Recent select tree harvest with no logging slash treatment. 52 Lake Tahoe National Forest Pathways Handbook FuelbedID Age class Harvest / Change (yr) fuel treatment agent LT072 0-10 None Wildfire LT073 10-25 None None LT074 120+ None None LT075 120+ Select cut None LT076 120+ Select cut, RX fire, pile burn None LT077 120+ Select cut LT078 120+ Select cut, Pile (no burn) None LT079 120+ Select cut, Pile (no burn) None LT080 0-7 Salvage Wildfire LT081 7-25 None None LT085 80-120 Select cut, Mastication None LT088 120+ None None None Fuelbed name / description Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established less than 10 years ago following stand-replacement wildfire with no salvage harvest. Stand is dominated by herbaceous vegetation with 10% cover of canopy trees. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 10 to 25 years ago following stand-replacement wildfire with no salvage harvest and no subsequent management. Stand is composed of seedlings and saplings. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Stands have had past select tree harvests but no recent management. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Stands have had two select tree harvests with no treatment of logging slash. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Recent select tree harvest with logging slash piled and burned or treated with prescribed fire. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Recent select tree harvest with no treatment of logging slash. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Stands have no history of management until a recent select tree harvest with logging slash piled but not burned. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Recent select tree harvest with logging slash piled but not burned. Mixed conifer forest. Occurs at middle elevations in the Lake Tahoe Basin. Established less than 7 years ago following stand-replacement wildfire with salvage harvest. Stand is currently dominated by shrubs with 10% cover of trees. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 7 to 25 years ago following stand-replacement wildfire with salvage harvest and no subsequent management. Stand is dominated by shrubs with seedlings and saplings in the canopy. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established 80 to 120 years ago following stand-replacement wildfire. Recent select tree, cut to length harvest with mastication of logging slash, shrubs and small trees. Mixed conifer forest. Occurs at middle elevations of the Lake Tahoe Basin. Established over 120 years ago following stand-replacement wildfire. Stands have had past select tree harvest with mastication but no recent management. 53 Lake Tahoe National Forest Pathways Handbook 6. Mixed conifer fuelbed FCCS outputs Mixed conifer fuelbed FCCS Outputs Fuelbed LT061 Fuelbed LT060 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 10.9 10.9 10.9 10.9 10.9 10.9 10.9 10.9 10.9 1.2 1.3 1.7 3.3 3.3 3.5 5.7 5.7 5.8 2.0 2.2 2.8 5.4 5.5 5.7 9.4 9.4 9.6 2.4 2.6 3.3 6.5 6.6 6.8 11.2 11.2 11.4 0.3 0.3 0.5 2.3 2.3 2.5 7.4 7.4 7.7 0.5 0.6 1.1 4.5 4.6 5.1 14.8 14.9 15.3 0.7 0.8 1.4 5.9 6.1 6.6 19.4 19.5 20.1 313 313 313 523 523 523 823 823 823 313 313 313 523 523 523 823 823 823 313 313 313 523 523 523 823 823 823 8 8 8 9 9 9 10 10 10 8 9 9 10 10 10 13 13 13 9 9 9 12 12 12 13 13 13 TL3 TL3 TL7 TL8 TL8 TL8 TU5 TU5 TU5 TL7 TL5 TL5 TU5 TU5 TU5 SB3 SB3 SB3 TL5 TL5 TL8 SB3 SB3 SB3 SB3 SB3 SB3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 2.1 2.3 2.9 4.2 4.3 4.5 7.1 7.2 7.3 2.9 3.2 4.2 7.0 7.2 7.6 12.0 12.1 12.4 3.5 4.0 5.2 8.7 8.9 9.4 14.9 15.0 15.3 0.9 1.1 1.7 3.9 4.0 4.6 12.3 12.5 13.1 1.2 1.5 2.7 8.2 8.6 9.8 26.3 26.7 27.9 1.6 2.1 3.8 11.6 12.1 13.8 37.2 37.7 39.4 318 418 418 628 628 628 938 938 938 318 418 418 628 628 628 938 938 938 318 418 418 628 628 628 938 938 938 9 9 9 10 10 10 12 12 12 9 9 10 12 12 12 13 13 13 9 10 10 13 13 13 13 13 13 TL3 TL5 TL8 TU2 TU2 TU2 SB3 SB3 SB3 TL8 TL8 TU2 SB3 SB3 SB3 SB3 SB3 SB3 TL8 TU2 TU2 SB3 SB3 SB3 SB3 SB3 SB3 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 54 Lake Tahoe National Forest Pathways Handbook Mixed conifer fuelbed FCCS Outputs Fuelbed LT063 Fuelbed LT062 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 11.7 11.7 11.7 11.7 11.7 11.7 11.7 11.7 11.7 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 16.1 16.1 16.1 16.1 16.1 16.1 16.1 16.1 16.1 3.7 4.1 5.3 8.8 8.9 9.5 14.9 15.0 15.3 5.1 5.7 7.3 12.2 12.4 13.1 20.7 20.9 21.3 6.1 6.8 8.7 14.5 14.8 15.6 24.7 24.8 25.3 1.7 2.2 3.7 11.2 11.6 13.2 35.5 35.9 37.5 2.8 3.5 6.1 18.5 19.2 21.8 58.7 59.4 62.0 3.7 4.7 8.0 24.3 25.3 28.6 77.0 78.0 81.4 526 526 526 946 946 946 966 966 966 526 526 526 946 946 946 966 966 966 526 526 526 946 946 946 966 966 966 9 10 10 13 13 13 13 13 13 10 10 12 13 13 13 13 13 13 12 12 13 13 13 13 4 4 4 TL8 TU2 TU2 SB3 SB3 SB3 SB3 SB3 SB3 TU2 TU5 SB3 SB3 SB3 SB3 SB4 SB4 SB4 SB2 SB3 SB3 SB3 SB3 SB3 GR8 GR8 GR8 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 1.5 1.7 2.2 2.1 2.2 2.6 3.1 3.1 3.4 1.9 2.2 2.8 2.6 2.8 3.3 3.8 3.9 4.3 2.4 2.7 3.5 3.3 3.5 4.1 4.8 4.9 5.3 1.5 1.9 3.3 2.9 3.3 4.7 6.5 6.9 8.3 2.1 2.6 4.5 4.0 4.6 6.4 9.0 9.6 11.4 2.8 3.5 6.1 5.4 6.2 8.7 12.2 12.9 15.4 313 313 423 443 443 543 643 643 743 313 313 423 443 443 543 643 643 743 313 313 423 443 443 543 643 643 743 8 8 9 9 9 9 9 9 9 8 9 9 9 9 9 9 9 10 9 9 9 9 9 10 10 10 10 TL7 TL7 TL5 TL3 TL5 TL6 TL8 TL8 TU2 TL7 TL5 TL6 TL6 TL6 TL8 TL9 TL9 TU4 TL5 TL6 TL8 TL8 TL8 TU4 TU4 TU4 TU4 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 55 Lake Tahoe National Forest Pathways Handbook Mixed conifer fuelbed FCCS Outputs Fuelbed LT065 Fuelbed LT064 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1.7 1.9 2.5 2.3 2.4 2.9 3.2 3.3 3.7 2.2 2.4 3.1 2.9 3.0 3.6 4.1 4.2 4.6 2.7 3.0 3.9 3.6 3.8 4.5 5.1 5.2 5.7 1.5 1.9 3.2 2.7 3.1 4.4 5.8 6.2 7.6 2.0 2.6 4.5 3.7 4.3 6.1 8.0 8.6 10.4 2.8 3.5 6.0 5.0 5.8 8.3 10.8 11.6 14.1 316 316 416 446 446 546 656 656 656 316 316 416 446 446 546 656 656 656 316 316 416 446 446 546 656 656 656 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 10 10 10 9 9 9 9 9 10 10 10 10 TL7 TL7 TL5 TL5 TL5 TL6 TL8 TL8 TL8 TL5 TL5 TL8 TL6 TL8 TL8 TU2 TU2 TU4 TL5 TL8 TL9 TL8 TL9 TU2 TU4 TU4 TU3 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 1.6 1.8 2.3 2.0 2.2 2.6 3.2 3.3 3.4 2.0 2.2 2.8 2.6 2.7 3.2 4.4 4.4 4.6 2.5 2.8 3.5 3.4 3.5 4.0 5.6 5.7 5.8 1.3 1.7 2.9 2.3 2.7 3.9 6.4 6.5 6.9 1.9 2.4 4.1 3.5 3.7 5.4 10.6 10.8 11.4 2.5 3.2 5.5 4.9 5.2 7.3 14.9 15.1 16.1 316 316 416 446 446 546 756 756 756 316 316 416 446 446 546 756 756 756 316 316 416 446 446 546 756 756 756 8 8 9 9 9 9 9 9 9 8 9 9 9 9 9 10 10 10 9 9 9 9 9 10 10 10 10 TL7 TL7 TL5 TL3 TL5 TL6 TL8 TL8 TL8 TL7 TL5 TL6 TL6 TL6 TL8 TU4 TU4 TU4 TL5 TL5 TL8 TL8 TL8 TU2 TU3 TU3 TU3 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 56 Lake Tahoe National Forest Pathways Handbook Mixed conifer fuelbed FCCS Outputs Fuelbed LT067 Fuelbed LT066 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 1.1 1.2 1.5 1.5 1.6 1.8 2.2 2.3 2.4 1.5 1.7 2.1 2.1 2.2 2.5 3.0 3.1 3.4 1.9 2.1 2.6 2.6 2.7 3.1 3.7 3.8 4.1 0.7 0.9 1.5 1.5 1.6 2.2 3.3 3.5 4.1 1.0 1.3 2.1 2.0 2.2 3.1 4.5 4.8 5.6 1.4 1.7 2.8 2.7 3.0 4.2 6.1 6.5 7.6 212 312 312 322 322 422 432 432 532 212 312 312 322 322 422 432 432 532 212 312 312 322 322 422 432 432 532 8 8 8 8 8 8 9 9 9 8 8 9 9 9 9 9 9 9 8 9 9 9 9 9 9 9 10 TL3 TL4 TL7 TL7 TL7 TL7 TL5 TL6 TL6 TL7 TL7 TL5 TL3 TL5 TL5 TL8 TL8 TL8 TL7 TL3 TL5 TL5 TL5 TL8 TL8 TL9 TU2 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 2.3 2.5 3.2 3.1 3.2 3.8 4.4 4.6 4.9 2.9 3.2 4.1 4.0 4.2 4.9 6.1 6.1 6.4 3.6 4.0 5.1 4.9 5.2 6.0 7.8 7.9 8.1 1.3 1.6 2.7 2.5 2.8 3.9 5.6 5.9 7.0 1.8 2.3 3.8 3.5 3.9 5.4 8.8 9.0 9.7 2.4 3.0 5.1 4.7 5.3 7.3 12.8 13.0 13.9 315 415 415 435 435 535 645 645 645 315 415 415 435 435 535 645 645 645 315 415 415 435 435 535 645 645 645 9 9 9 9 9 9 10 10 10 9 9 10 9 10 10 12 12 12 9 10 10 10 10 12 12 12 13 TL5 TL5 TL8 TL8 TL8 TL9 TU2 TU2 TU2 TL8 TL8 TU2 TL9 TU2 TU2 SB2 SB2 SB3 TL8 TU2 TU2 TU2 TU2 SB2 SB3 SB3 SB3 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 57 Lake Tahoe National Forest Pathways Handbook Mixed conifer fuelbed FCCS Outputs Fuelbed LT069 Fuelbed LT068 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 1.1 1.2 1.6 1.5 1.6 1.9 2.2 2.3 2.5 1.5 1.7 2.1 2.1 2.2 2.5 3.0 3.1 3.3 1.9 2.1 2.6 2.6 2.7 3.1 3.7 3.8 4.1 0.5 0.7 1.1 1.0 1.2 1.6 2.3 2.5 2.9 0.7 0.9 1.5 1.4 1.6 2.2 3.2 3.4 4.0 1.0 1.2 2.0 1.9 2.2 3.0 4.3 4.6 5.4 213 313 313 323 323 323 433 433 433 213 313 313 323 323 323 433 433 433 213 313 313 323 323 323 433 433 433 8 8 8 8 8 8 9 9 9 8 8 9 9 9 9 9 9 9 8 9 9 9 9 9 9 9 10 TL3 TL3 TL7 TL7 TL7 TL7 TL5 TL5 TL5 TL7 TL7 TL5 TL3 TL5 TL5 TL8 TL8 TL8 TL7 TL3 TL5 TL5 TL5 TL8 TL8 TL9 TU2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 1.0 1.1 1.4 1.4 1.5 1.7 2.0 2.1 2.3 1.4 1.5 1.9 1.9 2.0 2.3 2.8 2.8 3.1 1.7 1.9 2.4 2.3 2.5 2.8 3.4 3.5 3.7 0.5 0.7 1.1 1.0 1.2 1.6 2.4 2.5 2.9 0.7 0.9 1.5 1.4 1.6 2.2 3.3 3.4 4.1 1.0 1.2 2.0 1.9 2.2 3.0 4.4 4.7 5.5 213 213 313 323 323 323 433 433 433 213 213 313 323 323 323 433 433 433 213 213 313 323 323 323 433 433 433 8 8 8 8 8 8 9 9 9 8 8 8 8 9 9 9 9 9 8 8 9 9 9 9 9 9 9 TL3 TL3 TL4 TL4 TL4 TL7 TL3 TL3 TL5 TL3 TL7 TL7 TL7 TL3 TL5 TL5 TL6 TL8 TL7 TL7 TL5 TL5 TL5 TL5 TL8 TL8 TL8 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 58 Lake Tahoe National Forest Pathways Handbook Mixed conifer fuelbed FCCS Outputs Fuelbed LT071 Fuelbed LT070 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 0.8 0.9 1.2 1.1 1.2 1.3 1.5 1.6 1.7 1.1 1.2 1.5 1.4 1.5 1.7 2.0 2.0 2.2 1.3 1.5 1.9 1.8 1.9 2.2 2.5 2.6 2.8 0.5 0.6 1.0 0.9 1.0 1.5 2.0 2.1 2.5 0.7 0.9 1.4 1.3 1.4 2.0 2.7 2.9 3.4 0.9 1.2 1.9 1.7 1.9 2.7 3.6 3.9 4.7 212 212 212 212 212 312 322 322 422 212 212 212 212 212 312 322 322 422 212 212 212 212 212 312 322 322 422 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 8 8 8 8 8 9 9 9 9 TL3 TL3 TL4 TL3 TL4 TL4 TL7 TL7 TU1 TL3 TL4 TL4 TL4 TL4 TL7 TU1 TL3 TL6 TL4 TL4 TL7 TL7 TL7 TL5 TL6 TL6 TL6 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 1.6 1.8 2.3 2.1 2.2 2.6 3.3 3.4 3.4 2.0 2.2 2.8 2.7 2.8 3.3 4.6 4.6 4.7 2.5 2.8 3.6 3.4 3.5 4.1 5.7 5.8 5.9 1.1 1.4 2.3 2.0 2.2 3.2 5.4 5.5 5.9 1.6 1.9 3.2 3.0 3.1 4.4 9.1 9.2 9.7 2.1 2.6 4.3 4.0 4.2 5.9 12.3 12.5 13.2 314 314 414 324 424 424 634 634 634 314 314 414 324 424 424 634 634 634 314 314 414 324 424 424 634 634 634 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 10 10 10 9 9 9 9 9 10 10 10 10 TL7 TL7 TL5 TL3 TL5 TL5 TL8 TL8 TL8 TL3 TL5 TL5 TL5 TL5 TL8 TU4 TU4 TU4 TL5 TL5 TL8 TL8 TL8 TU2 TU3 TU3 TU3 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 59 Lake Tahoe National Forest Pathways Handbook Mixed conifer fuelbed FCCS Outputs Fuelbed LT073 Fuelbed LT072 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0.5 0.6 0.7 0.7 0.8 0.9 1.0 1.1 1.1 0.8 0.9 1.1 1.1 1.1 1.3 1.9 1.9 1.9 0.9 1.0 1.3 1.3 1.3 1.6 2.2 2.2 2.3 0.2 0.3 0.4 0.4 0.4 0.6 0.9 0.9 1.1 0.3 0.4 0.6 0.6 0.6 0.9 1.9 1.9 2.0 0.4 0.5 0.8 0.8 0.8 1.2 2.5 2.5 2.6 211 211 211 211 211 211 311 311 311 211 211 211 211 211 211 311 311 311 211 211 211 211 211 211 311 311 311 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL3 TL4 TL7 TL7 TL7 TL3 TL3 TL3 TL3 TL4 TL7 TL5 TL5 TL5 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 1.2 1.3 1.6 2.3 2.3 2.4 3.9 3.9 3.9 1.6 1.7 2.2 3.7 3.7 3.9 6.3 6.3 6.4 1.9 2.1 2.7 4.6 4.7 4.9 7.8 7.9 8.0 0.5 0.6 1.0 2.1 2.1 2.4 6.6 6.7 6.9 0.7 0.8 1.4 4.3 4.4 5.0 13.7 13.8 14.4 0.9 1.1 1.9 6.1 6.3 7.1 19.6 19.8 20.6 218 318 318 428 428 428 728 728 828 218 318 318 428 428 428 728 728 828 218 318 318 428 428 428 728 728 828 8 8 8 9 9 9 9 9 9 8 8 9 9 9 9 12 12 12 8 9 9 10 10 10 12 12 13 TL3 TL3 TL7 TL5 TL5 TL5 TL9 TL9 TL9 TL7 TL7 TL5 TL8 TL8 TL9 SB3 SB3 SB3 TL7 TL3 TL5 TU2 TU2 TU2 SB3 SB3 SB2 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 60 Lake Tahoe National Forest Pathways Handbook Mixed conifer fuelbed FCCS Outputs Fuelbed LT075 Fuelbed LT074 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 1.5 1.7 2.2 2.1 2.2 2.6 3.1 3.1 3.4 2.0 2.3 2.8 2.8 2.9 3.4 4.0 4.1 4.5 2.5 2.8 3.5 3.4 3.6 4.2 5.0 5.1 5.5 1.3 1.6 2.6 2.5 2.8 3.8 5.5 5.8 6.9 1.7 2.2 3.6 3.4 3.8 5.3 7.6 8.1 9.5 2.3 2.9 4.9 4.6 5.1 7.1 10.3 10.9 12.8 316 316 416 436 436 546 646 646 646 316 316 416 436 436 546 646 646 646 316 316 416 436 436 546 646 646 646 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 10 10 10 9 9 9 9 9 10 10 10 10 TL7 TL7 TL5 TL3 TL5 TL6 TL8 TL8 TL8 TL3 TL5 TL6 TL5 TL8 TL8 TU2 TU2 TU4 TL5 TL5 TL8 TL8 TL8 TU2 TU4 TU4 TU3 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 2.1 2.3 2.9 2.8 2.9 3.4 4.0 4.1 4.4 2.7 2.9 3.7 3.6 3.8 4.4 5.4 5.4 5.7 3.3 3.6 4.6 4.4 4.7 5.4 6.9 6.9 7.1 1.1 1.4 2.3 2.1 2.4 3.3 4.7 5.0 5.9 1.6 1.9 3.2 2.9 3.3 4.6 7.1 7.2 8.1 2.1 2.6 4.3 4.0 4.5 6.2 10.3 10.5 11.1 315 315 415 425 425 425 545 545 645 315 315 415 425 425 425 545 545 645 315 315 415 425 425 425 545 545 645 9 9 9 9 9 9 9 10 10 9 9 9 9 9 10 10 10 10 9 9 10 10 10 10 12 12 12 TL3 TL5 TL8 TL5 TL8 TL8 TL9 TU2 TU2 TL5 TL8 TL8 TL8 TL9 TU2 TU2 TU2 TU5 TL8 TL8 TU2 TU2 TU2 TU5 SB3 SB3 SB3 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 61 Lake Tahoe National Forest Pathways Handbook Mixed conifer fuelbed FCCS Outputs Fuelbed LT077 Fuelbed LT076 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 1.0 1.1 1.4 1.4 1.4 1.7 2.0 2.0 2.2 1.4 1.5 1.9 1.9 2.0 2.3 2.7 2.8 3.0 1.7 1.9 2.4 2.3 2.4 2.8 3.3 3.4 3.7 0.5 0.6 1.1 1.0 1.1 1.6 2.3 2.4 2.8 0.7 0.9 1.5 1.4 1.6 2.2 3.1 3.3 3.9 1.0 1.2 2.0 1.9 2.1 2.9 4.2 4.4 5.2 214 214 314 334 334 334 444 444 444 214 214 314 334 334 334 444 444 444 214 214 314 334 334 334 444 444 444 8 8 8 8 8 8 8 9 9 8 8 8 8 8 9 9 9 9 8 8 9 9 9 9 9 9 9 TL3 TL3 TL4 TL4 TL4 TL7 TL7 TL3 TL5 TL3 TL7 TL7 TL7 TL7 TL5 TL5 TL5 TL8 TL7 TL7 TL5 TL5 TL5 TL5 TL8 TL8 TL8 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 2.2 2.4 3.1 2.9 3.1 3.6 4.2 4.3 4.6 2.8 3.1 3.9 3.7 3.9 4.6 5.7 5.7 5.9 3.5 3.8 4.9 4.6 4.9 5.7 7.3 7.4 7.6 1.1 1.4 2.3 2.1 2.3 3.3 4.5 4.7 5.7 1.6 1.9 3.2 2.8 3.2 4.5 7.2 7.4 7.8 2.1 2.6 4.3 3.8 4.3 6.1 10.5 10.7 11.4 316 416 416 446 446 446 556 556 656 316 416 416 446 446 446 556 556 656 316 416 416 446 446 446 556 556 656 9 9 9 9 9 9 10 10 10 9 9 9 9 9 10 10 10 10 9 9 10 10 10 10 12 12 12 TL5 TL5 TL8 TL8 TL8 TL8 TU2 TU2 TU2 TL5 TL8 TL9 TL8 TL9 TU2 TU5 TU5 TU5 TL8 TL9 TU2 TU2 TU2 TU5 SB3 SB3 SB3 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 62 Lake Tahoe National Forest Pathways Handbook Mixed conifer fuelbed FCCS Outputs Fuelbed LT079 Fuelbed LT078 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 1.0 1.1 1.4 1.4 1.4 1.7 2.0 2.0 2.2 1.3 1.5 1.9 1.8 1.9 2.2 2.6 2.7 2.9 1.6 1.8 2.3 2.2 2.4 2.7 3.2 3.3 3.6 0.5 0.6 1.1 1.0 1.1 1.6 2.2 2.4 2.8 0.7 0.9 1.5 1.4 1.6 2.1 3.1 3.3 3.9 1.0 1.2 2.0 1.9 2.1 2.9 4.2 4.4 5.2 214 214 314 334 334 334 444 444 444 214 214 314 334 334 334 444 444 444 214 214 314 334 334 334 444 444 444 8 8 8 8 8 8 8 9 9 8 8 8 8 8 9 9 9 9 8 8 9 9 9 9 9 9 9 TL3 TL3 TL4 TL4 TL4 TL7 TL7 TL3 TL5 TL3 TL4 TL7 TL7 TL7 TL5 TL5 TL5 TL8 TL7 TL7 TL5 TL5 TL5 TL5 TL8 TL8 TL8 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 1.0 1.1 1.4 1.3 1.4 1.6 1.9 2.0 2.1 1.3 1.4 1.8 1.7 1.8 2.1 2.5 2.6 2.8 1.6 1.8 2.2 2.2 2.3 2.6 3.1 3.2 3.5 0.5 0.6 1.1 1.0 1.1 1.5 2.2 2.3 2.8 0.7 0.9 1.5 1.4 1.5 2.1 3.1 3.2 3.8 1.0 1.2 2.0 1.8 2.1 2.9 4.1 4.4 5.2 212 212 312 312 312 312 322 432 432 212 212 312 312 312 312 322 432 432 212 212 312 312 312 312 322 432 432 8 8 8 8 8 8 8 8 9 8 8 8 8 8 9 9 9 9 8 8 9 9 9 9 9 9 9 TL3 TL3 TL4 TL4 TL4 TL7 TL7 TL7 TL5 TL3 TL4 TL7 TL7 TL7 TL5 TL5 TL5 TL6 TL7 TL7 TL5 TL5 TL5 TL5 TL8 TL8 TL8 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 63 Lake Tahoe National Forest Pathways Handbook Mixed conifer fuelbed FCCS Outputs Fuelbed LT081 Fuelbed LT080 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 10.9 10.9 10.9 10.9 10.9 10.9 10.9 10.9 10.9 1.2 1.3 1.7 3.3 3.3 3.5 5.7 5.7 5.8 2.0 2.2 2.8 5.4 5.5 5.7 9.4 9.4 9.6 2.4 2.6 3.3 6.5 6.6 6.8 11.2 11.2 11.4 0.3 0.3 0.5 2.3 2.3 2.5 7.4 7.4 7.7 0.5 0.6 1.1 4.5 4.6 5.1 14.8 14.9 15.3 0.7 0.8 1.4 5.9 6.1 6.6 19.4 19.5 20.1 322 322 332 542 542 542 842 842 842 322 322 332 542 542 542 842 842 842 322 322 332 542 542 542 842 842 842 8 8 8 9 9 9 10 10 10 8 9 9 10 10 10 13 13 13 9 9 9 12 12 12 13 13 13 TL3 TL3 TL7 TL8 TL8 TL8 TU5 TU5 TU5 TL7 TL5 TL5 TU5 TU5 TU5 SB3 SB3 SB3 TL5 TL5 TL8 SB3 SB3 SB3 SB3 SB3 SB3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 2.1 2.3 2.9 4.2 4.3 4.5 7.1 7.2 7.3 2.9 3.2 4.2 7.0 7.2 7.6 12.0 12.1 12.4 3.5 4.0 5.2 8.7 8.9 9.4 14.9 15.0 15.3 0.9 1.1 1.7 3.9 4.0 4.6 12.3 12.5 13.1 1.2 1.5 2.7 8.2 8.6 9.8 26.3 26.7 27.9 1.6 2.1 3.8 11.6 12.1 13.8 37.2 37.7 39.4 332 432 432 642 642 642 962 962 962 332 432 432 642 642 642 962 962 962 332 432 432 642 642 642 962 962 962 9 9 9 10 10 10 12 12 12 9 9 10 12 12 12 13 13 13 9 10 10 13 13 13 13 13 13 TL3 TL5 TL8 TU2 TU2 TU2 SB3 SB3 SB3 TL8 TL8 TU2 SB3 SB3 SB3 SB3 SB3 SB3 TL8 TU2 TU2 SB3 SB3 SB3 SB3 SB3 SB3 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 64 Lake Tahoe National Forest Pathways Handbook Mixed conifer fuelbed FCCS Outputs Fuelbed LT088 Fuelbed LT085 Windspeed mph Slope % Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs Reaction Intensity (1,000 btu/ft2/min) Flame Length (ft) Rate of Spread (ft/min) FCCS Fire Potentials Crosswalk – FBPS FMs Crosswalk – Standard FMs D4L4C1 Moisture Scenario D2L2C3 Moisture Scenario D1L1C4 Moisture Scenario 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 0 0 0 3 3 3 7 7 7 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 00 30 70 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 2.4 2.7 3.4 3.2 3.4 3.9 4.6 4.7 5.1 3.0 3.4 4.3 4.0 4.2 5.0 6.5 6.5 6.7 3.8 4.2 5.3 5.1 5.3 6.2 8.4 8.5 8.8 1.3 1.6 2.7 2.4 2.7 3.8 5.4 5.5 6.5 1.8 2.3 3.8 3.3 3.7 5.2 9.4 9.6 10.2 2.4 3.0 5.1 4.6 5.0 7.1 13.9 14.2 15.0 315 415 415 435 435 535 645 645 645 315 415 415 435 435 535 645 645 645 315 415 415 435 435 535 645 645 645 9 9 9 9 9 9 10 10 10 9 9 10 9 10 10 12 12 12 9 10 10 10 10 12 13 13 13 TL5 TL5 TL8 TL8 TL8 TL9 TU2 TU2 TU2 TL8 TL8 TU2 TL9 TU2 TU2 SB3 SB3 SB3 TL9 TU2 TU2 TU2 TU2 SB2 SB3 SB3 SB3 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 2.5 2.7 3.4 3.2 3.4 4.0 4.9 4.9 5.2 3.1 3.4 4.3 4.2 4.3 5.1 6.9 7.0 7.2 3.9 4.3 5.4 5.4 5.5 6.3 8.9 9.0 9.3 1.3 1.6 2.6 2.3 2.6 3.7 5.6 5.7 6.4 1.7 2.2 3.6 3.3 3.6 5.0 9.9 10.1 10.7 2.3 2.9 4.9 4.8 5.1 6.8 14.5 14.8 15.7 417 417 417 447 447 547 657 657 757 417 417 417 447 447 547 657 657 757 417 417 417 447 447 547 657 657 757 9 9 9 9 9 10 10 10 10 9 9 10 10 10 10 12 12 12 9 10 10 10 10 12 13 13 13 TL5 TL5 TL8 TL8 TL8 TU2 TU2 TU2 TU2 TL8 TL8 TU2 TU2 TU2 TU2 SB3 SB3 SB3 TL9 TU2 TU2 TU2 TU5 SB3 SB3 SB3 SB3 2 Notes: FCCS Fire Potentials = 3 digit code representing Fuel Characteristic Classification System Surface Fire Behavior Potential, Crown Fire Potential and Available Fuel Potential; FBPS FMs = Fire Behavior Prediction System Fuel Models (Rothermel 1972, Albini1976); Standard FMs = Standard Fuel Models (Scott and Burgan 2005). To convert Rate of Spread to ch/hr multiply ft/min by 0.9090909. 65 Lake Tahoe National Forest Pathways Handbook 7. Additional Lake Tahoe National Forest Fuelbeds Age class Harvest / Change FuelbedID (yr) fuel treatment agent LT090 None None LT091 None None LT092 None None LT093 None None LT094 None None FCCS001 None None FCCS046 None None Fire exclusion, Grazing, Introduction of Exotic Species FCCS056 None FCCS069 None Fuelbed name / description Huckleberry oak shrublands occur in the mountains of Oregon and California typically on thin, rocky soils along ridges and upper slopes in the subalpine and montane zones from 2,300 to over 10,000 feet. This fuelbed is a mature huckleberry oak shrubland type over 40 years old. Greenleaf manzanita shrublands occur from the eastern Sierra Nevada east to Colorado and Arizona in summer-dry sites generally on rocky soils from 2,600 to 9,800 feet in elevation. This fuelbed is a mature greenleaf manzanita shrubland over 40 years old. Alpine and subalpine meadows dominated by shorthair reedgrass and threadleaf sedge occur between 4,200 and 12,500 feet in the Sierra Nevada. Many forb species occur in the meadows and shrubs such as dwarf bilberry and willows may be present. These meadows are typically cold and wet, and have a short growing season. Young quaking aspen forest. Occurs following disturbance, especially near riparian areas, throughout the Lake Tahoe basin. Quaking aspen forest. Aspen forests develop following disturbance, especially near riparian areas, throughout the Lake Tahoe basin. This fuelbed is dominated by pole-sized aspen over a rich herbaceous layer. Mixed forests such as these are composed of black cottonwood with other conifer and hardwood species, found along rivers and floodplains throughout the Pacific Northwest. Conifers can include Douglas-fir, ponderosa pine, grand fir, Engelmann spruce, and other species. Hardwoods can consist of various species of cottonwood, aspen, alder, maple, or birch. This chaparral type is mostly restricted to coastal mountain areas south from San Diego County north to interior Mendocino County in California, covering more than 1.5 million acres. At lower elevations, chamise (Adenostoma fasciculatum) is found with coastal sage shrubs. At higher elevations, chamise is codominant with arctostaphylos or ceanothus or both. Sagebrush steppe occurs throughout the Great Basin. Sagebrush densities have increased and native bunchgrass densities have decreased due to fire exclusion. In this sagebrush steppe in eastern Oregon, overgrazing and cultivation have also facilitated establishment of nonnative annual grasses. This fuelbed was developed based on data from John Day Fossil Beds National Monument. This eastern Oregon site has a mix of sagebrush (Artemesia spp.) and bitterbrush (Purshia tridentata) with scattered western juniper. Fire exclusion has resulted in western juniper encroachment into the sagebrush assemblage. Sagebrush shrublands are widespread throughout the Great Basin, with juniper woodlands above them in elevation and grasslands Fire exclusionbelow. 66 Lake Tahoe National Forest Pathways Handbook Age class Harvest / Change FuelbedID (yr) fuel treatment agent FCCS095 FCCS224 LF308 LF313 OW072 OW140 CO005 CO114 CO208 CO216 CO228 Fuelbed name / description Willow and alder shrubland. Found on floodplains and along streams and beaches throughout Alaska, and at transitions from forested to non-forested areas. This fuelbed is comparable to None None the closed tall alder -- willow shrub community of Viereck et al. (1992). Quaking aspen forests are found throughout the intermountain West. This fuelbed was developed based on data from Zion National Park and is dominated by quaking aspen with a None Fire exclusionsmall component of gambel oak, ponderosa pine, and white fir. Low sagebrush steppe found in Wyoming, western, Montana, southern Idaho, eastern oregon, northern Nevada, and Utah, northwestern Colorado and northeastern California. This fuelbed was partially developed based on data from Zion NP and SWSB 03 from photo series volume None None IV. Mountain mahogany are often in small tree or shrub form that reach heights between 6 and 27 feet and commonly occur in the drier sites of the Western United Sates. It is often associated with service berry, big and black sagebrush, bitterbrush, and rabbit brush along with wheat grass, idaho fescue, and cheat grasses. The Most sites have been disturbed fire and or None None grazing. None Avalanche Subalpine forest disturbed by avalanche. Current canopy is composed of trembling aspen. Ponderosa pine forest. Occurs at low to middle elevations of the eastern Cascade Range. Established 80 to 150 years ago following wildfire or clearcut harvest. High density stand with None None no history of management. Dry Douglas-fir and ponderosa pine forest. Occurs at middle elevations of the Cascade Range. Clearcut, Established less than 15 years ago by clearcut harvest and prescribed burning, or wildfire and Salvage, Rx fire Wildfire salvage logging, resulting in a shrubland with less than 10% overstory present. Ponderosa pine forest. Occurs at low to mid elevations of the eastern Cascades. Established Clearcut, Pile less than 15 years ago after clearcut harvest and prescribed burn, or wildfire and salvage burn, Rx fire, logging. Shrubland with less than 10% overstory present. Understory of high density planted Salvage Wildfire pines (over 200 tpa). Bitterbrush and rabbitbrush shrubland. Occurs throughout central Oregon and the Great Basin, with juniper woodlands above in elevation and grasslands below. Established 10 to 20 years None None ago after prescribed fire or wildfire with no subsequent management. Western juniper, bitterbrush and bunchgrass savanna. Occurs as transitional ecosystem between ponderosa pine forests and sagebrush steppe in eastern Oregon and throughout the None None Great Basin. Established 20 to 40 years ago after prescribed fire or wildfire. Sagebrush shrubland. Occurs in central Oregon and throughout the Great Basin. Sagebrush densities have increased and native bunchgrass densities have decreased with fire exclusion. None None This fuelbed represents sagebrush shrublands 20 to 40 years after prescribed fire or wildfire. FCCS= Fuel Characteristic Classification System standard fuelbeds OW= Fuelbeds developed for the Okanogan-Wenatchee National Forest CO= Fuelbeds developed for the central Oregon region LF= Fuelbeds developed for the LANDFIRE project 67 Lake Tahoe National Forest Pathways Handbook List of references Fites, Jo Ann. 1993. Ecological Guide to Mixed Conifer Plant Associations. Northern Sierra Nevada and Southern Cascades: Lassen, Plumas, Tahoe, and El Dorado National Forests. R5-ECOL-TP-001. Fites-Kaufman, J.A., et al. 2007. Montane and Subalpine Vegetation of the Sierra Nevada and Cascade Ranges. In Barbour, M.G., T. Keeler-Wolf, A.A. Schoenherr (Eds.), Terrestrial Vegetation of California, Third Edition (pp. 456-501). Berkeley: University of California Press. Ottmar, R.D.; Sandberg, D.V.; Riccardi, C.L.; Prichard, S.J. 2007. An overview of the Fuel Characteristic Classification System – quantifying, classifying, and creating fuelbeds for resource planning. Canadian Journal of Forest Research. 37(12): 2383-2393. Potter, Donald A. 1994. Guide to Forested Communities of the Upper Montane in the Central and Southern Sierra Nevada. R5-ECOL-TP-003. Riccardi, Cynthia L.; Ottmar, Roger D.; Sandberg, David V., Andreu, Anne; Elman, Ella; Kopper, Karen; Long, Jennifer. 2007. The fuelbed: a key element of the Fuel Characteristic Classification System. Canadian Journal of Forest Research. 37(12): 2394-2412. Sandberg, D.V.; Riccardi, C.L.; Schaaf, Mark D. 2007a. Reformulation of Rothermel’s wildland fire behavior model for heterogeneous fuelbeds. 37(12): 2438-2455. Sandberg, D.V.; Riccardi, C.L.; Schaaf, Mark D. 2007b. Fire potential rating for wildland fuelbeds using the Fuel Characteristic Classification System. 37(12): 2456-2463. Smith, Sydney. 1994. Ecological Guide to Eastside Pine Plant Associations. Northeastern California: Modoc, Lassen, Klamath, Shasta-Trinity, Plumas, and Tahoe National Forests. R5-ECOL-TP-004. Stephens, Scott L. and Jason.J. Moghaddas. 2005. Experimental fuel treatment impacts on forest structure, potential fire behavior, and predicted tree mortality in a California mixed conifer stand. Forest Ecology and Management (215) 21-36. 68 Lake Tahoe National Forest Pathways Handbook Rothermel, R.C. 1972. A mathematical model for predicting fire spread in wildland fuels. Res. Pap. INT-115. Ogden, UT: U.S. Department of Agriculture, Forest Service, Intermountain Forest and Range Experiment Station. 40 p p.Albini 1976 Scott, Joe H.; Burgan, Robert E. 2005. Standard fire behavior fuel models: a comprehensive set for use with Rothermel's surface fire spread model. Gen. Tech. Rep. RMRS-GTR-153. Fort Collins, CO: U.S. Department of Agriculture, Forest Service, Rocky Mountain Research Station. 72 p.. 69 Lake Tahoe National Forest Pathways Handbook Appendix A. Fuelbed Pathway Photos 1. Jeffrey pine – white fir LT001: 0-7 years after wildfire; no other disturbance or management. LT004: 50-80 years after wildfire; no other disturbance or management. 70 Lake Tahoe National Forest Pathways Handbook LT005: 80-120 years after wildfire; no other disturbance or management. LT006: more than 120 years after wildfire; no other disturbance or management. 71 Lake Tahoe National Forest Pathways Handbook LT007: 80-120 years after wildfire; recent select tree harvest with prescribed fire to reduce post-harvest woody fuels. LT009: 80-120 years after wildfire; recent select tree harvest with post-harvest woody fuels piled and burned. 72 Lake Tahoe National Forest Pathways Handbook LT010: 80-120 years after wildfire; recent select tree harvest with post-harvest woody fuels piled but not burned. LT011: more than 120 years after wildfire; recent select tree harvest with prescribed fire to reduce post-harvest woody fuels. 73 Lake Tahoe National Forest Pathways Handbook LT013: less than 10 years after wildfire; no other disturbance or management. LT015: more than 120 years after wildfire; previously select cut and burned; no recent disturbance or management. 74 Lake Tahoe National Forest Pathways Handbook LT017: more than 120 years after wildfire; recent select tree harvest with post-harvest woody fuels piled and burned. 75 Lake Tahoe National Forest Pathways Handbook 2. Red fir LT021: 10 years after wildfire with no salvage; shrubland with less than 10% cover of live overstory trees. LT024: 50-80 years after wildfire; no other disturbance or management. 76 Lake Tahoe National Forest Pathways Handbook LT025: 50-80 years after wildfire; thin from below, pile and burn. LT027: 80-120 years after wildfire; no other disturbance or management. 77 Lake Tahoe National Forest Pathways Handbook LT028: 80-120 years after wildfire; select cut, pile and burn. LT029: 80-120 years after wildfire; previously thinned, piled and burned; no recent management. LT031: 80-120 years after wildfire; previously thinned, piled and burned; recently select cut and piled. LT032: over 120 years after wildfire; no other disturbance or management. 78 Lake Tahoe National Forest Pathways Handbook LT033: over 120 years after wildfire; previously select cut and piled; recently select cut, piled and burned. LT036: over 120 years after wildfire; previously select cut, piled and burned; no recent management. 79 Lake Tahoe National Forest Pathways Handbook 80 Lake Tahoe National Forest Pathways Handbook 3. Wet lodgepole pine LT037: 0-10 years after wildfire. LT042: 40-80 years after wildfire; no other disturbance or management. 81 Lake Tahoe National Forest Pathways Handbook LT044: over 80 years after wildfire; insects have begun to attack trees. 82 Lake Tahoe National Forest Pathways Handbook 4. Whitebark pine – Lodgepole pine LT047: 40-90 years after wildfire; no other disturbance or management. LT048: 90-120 years after wildfire; no other disturbance or management. 83 Lake Tahoe National Forest Pathways Handbook LT049: over 120 years after wildfire; no other disturbance or management. 84 Lake Tahoe National Forest Pathways Handbook 5. Mountain hemlock forest LT054: 0-10 years after wildfire. LT057: 90-120 years after wildfire; no other disturbance or management. 85 Lake Tahoe National Forest Pathways Handbook 6. Mixed conifer LT060: 0-7 years after wildfire. LT061: 7-25 years after wildfire; no other disturbance or management. 86 Lake Tahoe National Forest Pathways Handbook LT064:80-120 years after wildfire; no other disturbance or management. LT065: over 120 years after wildfire; no other disturbance or management. 87 Lake Tahoe National Forest Pathways Handbook LT066: 80-120 years after wildfire; recently select cut and burned. LT067: 80-120 years after wildfire; recently select cut. 88 Lake Tahoe National Forest Pathways Handbook LT068: 80-120 years after wildfire; recently select cut, piled and burned. LT069: 80-120 years after wildfire; recently select cut and piled. 89 Lake Tahoe National Forest Pathways Handbook LT070: over 120 years after wildfire; recently select cut and burned. LT072: 0-7 years after wildfire. 90 Lake Tahoe National Forest Pathways Handbook LT074: over 120 years after wildfire; previously select cut, piled and burned; no recent management. LT076: over 120 years after wildfire; no other disturbance or management until recent select cut and burn. 91 Lake Tahoe National Forest Pathways Handbook LT080: 0-7 years after wildfire and salvage harvest. 92