USA Tent Policy NOTICE: No tents or canopies will be allowed on University South Alabama properties or events unless authorized by the appropriate University Departments and all provisions outlined in this policy are met. Events using tents or canopies that do not conform to this policy shall be terminated by the USA Police, Safety & Environmental Compliance Department and/or the Mobile Fire Department. . POLICY/PURPOSE: This document provides information and establishes general precautions and policy for individuals or groups that plan to use tent(s) and/or canopies on University South Alabama property or events. It provides a single source document of measures required for the safe use of tents and canopies. Definitions: Tent: A structure, enclosure or shelter constructed of fabric or pliable material supported by any manner except by air or the contents that it protects. Canopy: A structure, enclosure or shelter constructed of fabric or pliable materials supported by any manner, except by air or the contents it protects, and is open without sidewalls or drops on 75% or more of the perimeter. Flame-resistant treatment: A flame retardant that is applied to (or material that is composed of flameresistant material) applied to tents, air-supported, air-inflated or tensioned membrane structures and their appurtenances, sidewalls, drops and tops of temporary membrane structures, canopies, tarpaulins, floor coverings, bunting, combustible decorative materials and effects, including sawdust when used on floors or passageways and meets NFPA 701 standards. GENERAL INFORMATION: Tents and canopies may only be erected in approved locations with permission from the entity that owns or controls the space. All tents/canopies erected on USA’s main campus, regardless the dimensions must have a Dig Permit completed and approved when utilizing tent stakes larger than 12 inches for anchoring purposes. Contact USA Maintenance Department to start dig permit process 14 days prior to event. Final approval rests with the Safety & Environmental Compliance Office and/or the Mobile Fire Department. All tents and canopies having an area of 400 sq. ft. or greater require a Tent Permit. Utilize Tent Permit form #400 on USA Safety & Environmental Compliance website (http://www.southalabama.edu/environmental/reports.html) for application and approval process. The tent/canopy and decorative materials shall be flame-resistant or treated with a flame-resistant material. A certificate label or affidavit of treatment must be on location with structure. Tents/canopies must stay 20 ft. from property lot lines, buildings, other temporary membrane structures, other tents and canopies, parked vehicles or internal combustion engines. For the purpose of determining required distances, support ropes and guy wires shall be considered as part of the temporary membrane structure, tent or canopy. Open flame or other devices emitting flame, fire or heat or any flammable or combustible liquids, gas, charcoal or other cooking device or any other unapproved devices shall not be permitted inside or located within 20 ft. of the tent/canopy unless approved by Safety & Environmental Compliance and/or the Mobile Fire Department. No smoking is allowed inside of the tent/canopy. Portable fire extinguishers are required for all tents/canopies. Contact Safety & Environmental Compliance for type needed, number required and placement. Rental service companies to provide fire extinguishers for rental tents. Aisles and exits must be free and unobstructed during tent/canopy occupancy. Hay, straw, shavings or similar combustible materials shall not be located within any tent/canopy containing assembly occupancy, except the materials necessary for the daily feeding and care of animals. Sawdust and shavings utilized for a public performance or exhibit shall not be prohibited provided the sawdust and shavings are kept damp. Combustible materials shall not be permitted under stands or seats at any time. The areas within and adjacent to the tent/canopy, shall be maintained clear of all combustible materials or vegetation that could create a fire hazard within 50 ft. from the structure. Combustible trash shall be removed at least once a day from the structure during the period the structure is occupied by the public. All appliances, spotlights, lighting and sound systems shall be powered by electricity only and may require a separate electrical permit. Use of a generator is acceptable if approved by Safety and Environmental Compliance and/or the Mobile Fire Department. All tents/canopies shall be adequately roped, braced and anchored to withstand the elements of weather and prevent against collapsing. Anchors must be marked with warning tape and or painted. Tents/canopies may not be erected for more than 30 days. If an extended period is required a new request for approval and or permit must be submitted. Occupant Load The occupant load shall be determined by dividing the floor area of tent structure by (7). * Example: a 400 sq. ft. tent will allow an occupant load of 400 / 7 = 57 occupants. Exits Tents/canopies must have at least the minimum number of required exits as listed below. * Tents/canopies with occupant loads of 50 or more will also require exit signs that are either self-luminous or illuminated by internal/external fixtures. 10-199 persons 2 exits required 200-499 persons 3 exits required 500-999 persons 4 exits required 1,000 or more persons contact Safety & Environmental Compliance Cooking Restriction for Tents - Fire and Life Safety Open flame or other devices emitting flame, fire or heat or any other flammable or combustible liquids, gas, charcoal or other cooking device or any other unapproved devices shall not be permitted inside or located within 20 feet of a tent or other structure while open to the public unless approved by Safety & Environmental Compliance Office and/or the Mobile Fire Department. . Safety & Environmental Compliance Office and/or the Mobile Fire Department will review and determine approval to cook in a limited size tent is considered when a Fire and Life Safety Inspection confirms all of the following criteria: Area of tent, canopy or awning is 12 ft. x 12 ft. (144 sq. ft.) or less. Tent, canopy or awning material does not pose a fire hazard. Separation of 20 ft. minimum from other tents or structures is maintained. The approved structure is placed on solid ground free of hay, straw or similar combustible materials. Cooking and heating equipment is a minimum 10 feet from exits and combustible materials. Class K fire extinguisher readily accessible and available for use. Class 2A 10BC fire extinguisher readily accessible and available for use. Location of vehicles or equipment does not obstruct means of egress. LP-gas containers shall be located outside with safety release valves pointed away from the tent, canopy or awning. Heaters Safety & Environmental Compliance Office and/or the Mobile Fire Department will review and determine approval of any heating d IMPORTANT NOTE: Mobile County Health Department regulations are more restrictive for Commercial Food Service Establishments. A Fire Code compliant Concession Trailer or Stand with a Type 1 hood ventilation and fire suppression system may be required. Reference: 2009 International Fire Code Temporary Wiring: All wiring provided or used by the vendor shall be of a sufficient rating for its intended use. Common household extension cords shall not be used. When a utility cord is used, only one device shall be plugged into the cord. Multi-plug adaptors are not approved. Surge protection devices shall be used when multi-plug extensions are needed. GFCI (Ground Fault Circuit Interrupter) adapters must be utilized when water is present. All cords and adapters must be in good condition without damage to the protective wire casing.