GRUNDFOS DATA BOOKLET CRT 16- 14 A-P-A-E-AUUE 15kW 400D 50Hz Grundfos Pump 96117253 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/CRT16/96117253/CRT-16-14-A-P-A-E-AUUE.html info@lenntech.com tel. +31-15-261.09.00 fax. +31-15-261.62.89 BE > THINK > INNOVATE Company name: Created by: Phone: Fax: Date: Position Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - Qty. Description 1 CRT 16-14 A-P-A-E-AUUE Note! Product picture may differ from actual product Product No.: 96117253 Vertical, non-self-priming, multistage, in-line, centrifugal pump for installation in pipe systems and mounting on a foundation. The pump has the following characteristics: - Impellers, intermediate chambers and outer sleeve are made of - Pump head cover and base are made of - The shaft seal has assembly length according to EN 12756. - Power transmission is via cast iron split coupling. - Pipework connection is via PJE flanges/couplings. The motor is a 3-phase AC motor. Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Water 253 .. 393 K 293 K 998.2 kg/m³ Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Approvals on nameplate: Curve tolerance: 2900 rpm 16 m³/h 169 m AUUE CE,TR ISO 9906:1999 Annex A Materials: Pump housing: Impeller: Titanium ASTM B 265 Titanium ASTM B 265 Installation: Maximum ambient temperature: 333 K Max pressure at stated temp: 25 bar / 120 °C Printed from Grundfos CAPS [2013.03.059] 1/7 Company name: Created by: Phone: Fax: Date: Position Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - Qty. Description Flange standard: Pipe connection: Flange size for motor: Electrical data: Motor type: IE Efficiency class: Number of poles: Rated power - P2: Power (P2) required by pump: Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: Efficiency: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): 25 bar / -20 °C PJE 60,3 mm FF300 160MD IE3 2 15 kW 15 kW 15 kW 50 Hz 3 x 380-415 D/660-690 Y V 28,0-26,0/16,2-15,6 A 660-780 % 0,89-0,87 2930-2950 rpm IE3 91,9% 91,9-91,9 % 92,4-92,7 % 92,4-92,3 % 55 (Protect. water jets/dust) F Others: Label: Grundfos Blueflux Minimum efficiency index, MEI ≥: 0.69 Net weight: 136 kg Gross weight: 146 kg Printed from Grundfos CAPS [2013.03.059] 2/7 Company name: Created by: Phone: Fax: Date: Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 96117253 CRT 16-14 50 Hz H [m] CRT 16-14, 50Hz eta [%] Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ 200 100 180 90 160 80 140 70 120 60 100 50 80 40 60 30 40 20 20 10 0 0 0 2 4 6 P2 [kW] 8 10 12 14 16 18 20 22 Q [m³/h] NPSH [m] 14 14 12 12 10 10 8 8 6 6 4 4 2 2 0 0 Printed from Grundfos CAPS [2013.03.059] 3/7 Company name: Created by: Phone: Fax: Date: 80 140 70 120 60 100 50 80 40 60 30 40 20 20 10 0 15 20 P2 [kW] Q [m³/h] NPSH [m] 10 10 5 5 0 0 215 248 4 x ø13 200 261 Water 253 .. 393 K 293 K 998.2 kg/m³ 10 130 Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: 5 G 1/2 Flange standard: Connect code: Pipe connection: Flange size for motor: 0 0 Titanium ASTM B 265 Titanium ASTM B 265 A E 333 K 25 bar / 120 °C 25 bar / -20 °C PJE P 60,3 mm FF300 90 160 G 1/2 Installation: Maximum ambient temperature: Max pressure at stated temp: 100 180 G 1/2 Material code: Code for rubber: 200 314 Impeller: eta [%] 350 Materials: Pump housing: 2900 rpm 16 m³/h 169 m 203 m 14 AUUE CE,TR ISO 9906:1999 Annex A 14 A A CRT 16-14, 50Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ 204 Technical: Speed for pump data: Rated flow: Rated head: Head max: Impellers: Shaft seal: Approvals on nameplate: Curve tolerance: Stages: Pump version: Model: CRT 16-14 A-P-A-E-AUUE 96117253 5700396596174 H [m] ø60.1 Product name: Product No: EAN number: Value 26 Description Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 90 471 Printed from Grundfos CAPS [2013.03.059] L2 L3 +T L1 TO AMPLIFIER RELAY TO AMPLIFIER RELAY +T L1 +T L2 L3 +T +T +T Grundfos Blueflux IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE Others: Label: CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 44082 Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: Efficiency: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): Motor protec: Motor No: 160MD IE3 2 15 kW 15 kW 15 kW 50 Hz 3 x 380-415 D/660-690 Y V 28,0-26,0/16,2-15,6 A 660-780 % 0,89-0,87 2930-2950 rpm IE3 91,9% 91,9-91,9 % 92,4-92,7 % 92,4-92,3 % 55 (Protect. water jets/dust) F PTC 85U17526 1020 Electrical data: Motor type: IE Efficiency class: Number of poles: Rated power - P2: Power (P2) required by pump: 4/7 Company name: Created by: Phone: Fax: Date: Description Value Minimum efficiency index, MEI ≥: Net weight: Gross weight: 0.69 136 kg 146 kg Printed from Grundfos CAPS [2013.03.059] Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 5/7 Company name: Created by: Phone: Fax: Date: Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 96117253 CRT 16-14 50 Hz 350 204 G 1/2 G 1/2 4 x ø13 90 26 1020 G 1/2 ø60.1 471 314 130 200 215 248 261 Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details. Printed from Grundfos CAPS [2013.03.059] 6/7 Company name: Created by: Phone: Fax: Date: Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 96117253 CRT 16-14 50 Hz +T +T TO AMPLIFIER RELAY L1 +T L2 +T L3 +T TO AMPLIFIER IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 44082 +T RELAY L1 L2 L3 Note! All units are in [mm] unless others are stated. Printed from Grundfos CAPS [2013.03.059] 7/7 Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date. All information is copyright Grundfos. info@lenntech.com www.lenntech.com tel. +31-15-261.09.00 fax. +31-15-261.62.89