Qty. Description
1
CRT 16-10 A-P-A-E-AUUE
Note! Product picture may differ from actual product
Product No.: 96117251
Vertical, non-self-priming, multistage, in-line,
centrifugal pump for installation in pipe systems
and mounting on a foundation.
The pump has the following characteristics:
- Impellers, intermediate chambers and outer
sleeve are made of
- Pump head cover and base are made of
- The shaft seal has assembly length
according to EN 12756.
- Power transmission is via cast iron split
coupling.
- Pipework connection is via PJE
flanges/couplings.
The motor is a 3-phase AC motor.
Liquid:
Pumped liquid:
Liquid temperature range:
Liquid temp:
Density:
Water
253 .. 393 K
293 K
998.2 kg/m³
Technical:
Speed for pump data:
Rated flow:
Rated head:
Shaft seal:
Approvals on nameplate:
Curve tolerance:
2900 rpm
16 m³/h
120 m
AUUE
CE,TR
ISO 9906:1999 Annex A
Materials:
Pump housing:
Impeller:
Titanium
ASTM B 265
Titanium
ASTM B 265
Installation:
Maximum ambient temperature: 333 K
Max pressure at stated temp:
25 bar / 120 °C
Printed from Grundfos CAPS [2013.03.059]
1/7
Company name:
Created by:
Phone:
Fax:
Date:
Position
Lenntech BV - lenntech.com
info@lenntech.com
+31 15 2610900
+31 15 2616289
-
Qty. Description
Flange standard:
Pipe connection:
Flange size for motor:
Electrical data:
Motor type:
IE Efficiency class:
Number of poles:
Rated power - P2:
Power (P2) required by pump:
Mains frequency:
Rated voltage:
Rated current:
Starting current:
Cos phi - power factor:
Rated speed:
Efficiency:
Motor efficiency at full load:
Motor efficiency at 3/4 load:
Motor efficiency at 1/2 load:
Enclosure class (IEC 34-5):
Insulation class (IEC 85):
25 bar / -20 °C
PJE
60,3 mm
FF300
160MB
IE3
2
11 kW
11 kW
11 kW
50 Hz
3 x 380-415 D/660-690 Y V
20,8-19,8/12,0-11,8 A
660-780 %
0,88-0,84
2940-2950 rpm
IE3 91,2%
91,2-91,2 %
91,8-91,8 %
91,3-91,2 %
55 (Protect. water jets/dust)
F
Others:
Label:
Grundfos Blueflux
Minimum efficiency index, MEI ≥: 0.69
Net weight:
120 kg
Gross weight:
130 kg
Printed from Grundfos CAPS [2013.03.059]
2/7
Company name:
Created by:
Phone:
Fax:
Date:
Lenntech BV - lenntech.com
info@lenntech.com
+31 15 2610900
+31 15 2616289
-
96117251 CRT 16-10 50 Hz
H
[m]
CRT 16-10, 50Hz
eta
[%]
Pumped liquid = Water
Liquid temperature = 293 K
Density = 998.2 kg/m³
140
120
100
100
80
80
60
60
40
40
20
20
0
0
0
2
4
6
P2
[kW]
8
10
12
14
16
18
20
22
Q [m³/h]
NPSH
[m]
10
25
8
20
6
15
4
10
2
5
0
0
Printed from Grundfos CAPS [2013.03.059]
3/7
Company name:
Created by:
Phone:
Fax:
Date:
60
60
40
40
20
20
0
20
Q [m³/h]
NPSH
[m]
10
10
5
5
0
0
215
248
Water
253 .. 393 K
293 K
998.2 kg/m³
15
261
Liquid:
Pumped liquid:
Liquid temperature range:
Liquid temp:
Density:
10
200
Flange standard:
Connect code:
Pipe connection:
Flange size for motor:
5
P2
[kW]
Titanium
ASTM B 265
Titanium
ASTM B 265
A
E
333 K
25 bar / 120 °C
25 bar / -20 °C
PJE
P
60,3 mm
FF300
0
0
130
Installation:
Maximum ambient temperature:
Max pressure at stated temp:
80
4 x ø13
Material code:
Code for rubber:
80
G 1/2
Impeller:
100
350
Materials:
Pump housing:
100
G 1/2
2900 rpm
16 m³/h
120 m
145 m
10
AUUE
CE,TR
ISO 9906:1999 Annex A
10
A
A
eta
[%]
120
G 1/2
Technical:
Speed for pump data:
Rated flow:
Rated head:
Head max:
Impellers:
Shaft seal:
Approvals on nameplate:
Curve tolerance:
Stages:
Pump version:
Model:
140
314
CRT 16-10 A-P-A-E-AUUE
96117251
5700396596150
CRT 16-10, 50Hz
Pumped liquid = Water
Liquid temperature = 293 K
Density = 998.2 kg/m³
204
Product name:
Product No:
EAN number:
H
[m]
ø60.1
Value
26
Description
Lenntech BV - lenntech.com
info@lenntech.com
+31 15 2610900
+31 15 2616289
-
90
471
Printed from Grundfos CAPS [2013.03.059]
L2
L3
+T
L1
TO AMPLIFIER
RELAY
TO AMPLIFIER
RELAY
+T
L1
+T
L2
L3
+T
+T
+T
Grundfos Blueflux
IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE
Others:
Label:
CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY
THERMISTORS PTC ACCORDING TO DIN 44082
Mains frequency:
Rated voltage:
Rated current:
Starting current:
Cos phi - power factor:
Rated speed:
Efficiency:
Motor efficiency at full load:
Motor efficiency at 3/4 load:
Motor efficiency at 1/2 load:
Enclosure class (IEC 34-5):
Insulation class (IEC 85):
Motor protec:
Motor No:
160MB
IE3
2
11 kW
11 kW
11 kW
50 Hz
3 x 380-415 D/660-690 Y V
20,8-19,8/12,0-11,8 A
660-780 %
0,88-0,84
2940-2950 rpm
IE3 91,2%
91,2-91,2 %
91,8-91,8 %
91,3-91,2 %
55 (Protect. water jets/dust)
F
PTC
85U17524
840
Electrical data:
Motor type:
IE Efficiency class:
Number of poles:
Rated power - P2:
Power (P2) required by pump:
4/7
Company name:
Created by:
Phone:
Fax:
Date:
Description
Value
Minimum efficiency index, MEI ≥:
Net weight:
Gross weight:
0.69
120 kg
130 kg
Printed from Grundfos CAPS [2013.03.059]
Lenntech BV - lenntech.com
info@lenntech.com
+31 15 2610900
+31 15 2616289
-
5/7
Company name:
Created by:
Phone:
Fax:
Date:
Lenntech BV - lenntech.com
info@lenntech.com
+31 15 2610900
+31 15 2616289
-
96117251 CRT 16-10 50 Hz
350
204
G 1/2
G 1/2
4 x ø13
90
26
840
G 1/2
ø60.1
471
314
130
200
215
248
261
Note! All units are in [mm] unless others are stated.
Disclaimer: This simplified dimensional drawing does not show all details.
Printed from Grundfos CAPS [2013.03.059]
6/7
Company name:
Created by:
Phone:
Fax:
Date:
Lenntech BV - lenntech.com
info@lenntech.com
+31 15 2610900
+31 15 2616289
-
96117251 CRT 16-10 50 Hz
+T
+T
TO AMPLIFIER
RELAY
L1
+T
L2
+T
L3
+T
TO AMPLIFIER
IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE
CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY
THERMISTORS PTC ACCORDING TO DIN 44082
+T
RELAY
L1
L2
L3
Note! All units are in [mm] unless others are stated.
Printed from Grundfos CAPS [2013.03.059]
7/7
Disclaimer: The information about the Grundfos pump in this document may be outdated.
Data may be subject to alterations without further notice.
Please contact us to verify the data above is still accurate/up-to-date.
All information is copyright Grundfos.
info@lenntech.com
www.lenntech.com
tel. +31-15-261.09.00
fax. +31-15-261.62.89
Download