CRT 8- 10 A-P-A-E-AUUE 4kW 3x400D 50Hz Grundfos Pump 96117229

advertisement
GRUNDFOS DATA BOOKLET
CRT 8- 10 A-P-A-E-AUUE 4kW 3x400D 50Hz
Grundfos Pump 96117229
Thank you for your interest in our products
Please contact us for more information, or visit our website
http://www.lenntech.com/grundfos/CRT08/96117229/CRT-8-10-A-P-A-E-AUUE.html
info@lenntech.com
tel. +31-15-261.09.00
fax. +31-15-261.62.89
BE > THINK > INNOVATE
Company name:
Created by:
Phone:
Fax:
Date:
Position
Lenntech BV - lenntech.com
info@lenntech.com
+31 15 2610900
+31 15 2616289
-
Qty. Description
1
CRT 8-10 A-P-A-E-AUUE
Note! Product picture may differ from actual product
Product No.: 96117229
Vertical, non-self-priming, multistage, in-line,
centrifugal pump for installation in pipe systems
and mounting on a foundation.
The pump has the following characteristics:
- Impellers, intermediate chambers and outer
sleeve are made of
- Pump head cover and base are made of
- The shaft seal has assembly length
according to EN 12756.
- Power transmission is via cast iron split
coupling.
- Pipework connection is via PJE
flanges/couplings.
The motor is a 3-phase AC motor.
Liquid:
Pumped liquid:
Liquid temperature range:
Liquid temp:
Density:
Water
253 .. 393 K
293 K
998.2 kg/m³
Technical:
Speed for pump data:
Rated flow:
Rated head:
Shaft seal:
Approvals on nameplate:
Curve tolerance:
2900 rpm
9.5 m³/h
84.9 m
AUUE
CE,TR
ISO 9906:1999 Annex A
Materials:
Pump housing:
Impeller:
Titanium
ASTM B 265
Titanium
ASTM B 265
Installation:
Maximum ambient temperature: 333 K
Max pressure at stated temp:
25 bar / 120 °C
Printed from Grundfos CAPS [2013.03.059]
1/7
Company name:
Created by:
Phone:
Fax:
Date:
Position
Lenntech BV - lenntech.com
info@lenntech.com
+31 15 2610900
+31 15 2616289
-
Qty. Description
Flange standard:
Pipe connection:
Flange size for motor:
Electrical data:
Motor type:
IE Efficiency class:
Number of poles:
Rated power - P2:
Power (P2) required by pump:
Mains frequency:
Rated voltage:
Rated current:
Starting current:
Cos phi - power factor:
Rated speed:
Efficiency:
Motor efficiency at full load:
Motor efficiency at 3/4 load:
Motor efficiency at 1/2 load:
Enclosure class (IEC 34-5):
Insulation class (IEC 85):
25 bar / -20 °C
PJE
60,3 mm
FT130
112MC
IE3
2
4 kW
4 kW
4 kW
50 Hz
3 x 380-415 D V
7.9 A
1000-1110 %
0,87-0,87
2920-2940 rpm
IE3 88,1%
88,1-88,1 %
88,6-88,2 %
85,2-88,1 %
55 (Protect. water jets/dust)
F
Others:
Label:
Grundfos Blueflux
Minimum efficiency index, MEI ≥: 0.7
Net weight:
59 kg
Gross weight:
69 kg
Printed from Grundfos CAPS [2013.03.059]
2/7
Company name:
Created by:
Phone:
Fax:
Date:
Lenntech BV - lenntech.com
info@lenntech.com
+31 15 2610900
+31 15 2616289
-
96117229 CRT 8-10 50 Hz
H
[m]
CRT 8-10, 50Hz
eta
[%]
Pumped liquid = Water
Liquid temperature = 293 K
Density = 998.2 kg/m³
120
110
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
10
0
0
0
1
2
3
4
P2
[kW]
5
6
7
8
9
10
11
12
Q [m³/h]
NPSH
[m]
3.5
7
3.0
6
2.5
5
2.0
4
1.5
3
1.0
2
0.5
1
0.0
0
Printed from Grundfos CAPS [2013.03.059]
3/7
Company name:
Created by:
Phone:
Fax:
Date:
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
10
0
0
0
2
4
6
8
10
P2
[kW]
Q [m³/h]
NPSH
[m]
2
4
1
2
0
0
215
248
4 x ø13
Titanium
ASTM B 265
Titanium
ASTM B 265
A
E
261
130
200
G 1/2
Water
253 .. 393 K
293 K
998.2 kg/m³
G 1/2
Liquid:
Pumped liquid:
Liquid temperature range:
Liquid temp:
Density:
G 1/2
Flange standard:
Connect code:
Pipe connection:
Flange size for motor:
333 K
25 bar / 120 °C
25 bar / -20 °C
PJE
P
60,3 mm
FT130
80
372
Printed from Grundfos CAPS [2013.03.059]
TO AMPLIFIER
RELAY
+T
L1
+T
L2
L3
+T
L3
L2
L1
TO AMPLIFIER
RELAY
Grundfos Blueflux
+T
Others:
Label:
+T
Mains frequency:
Rated voltage:
Rated current:
Starting current:
Cos phi - power factor:
Rated speed:
Efficiency:
Motor efficiency at full load:
Motor efficiency at 3/4 load:
Motor efficiency at 1/2 load:
Enclosure class (IEC 34-5):
Insulation class (IEC 85):
Motor protec:
Motor No:
112MC
IE3
2
4 kW
4 kW
4 kW
50 Hz
3 x 380-415 D V
7.9 A
1000-1110 %
0,87-0,87
2920-2940 rpm
IE3 88,1%
88,1-88,1 %
88,6-88,2 %
85,2-88,1 %
55 (Protect. water jets/dust)
F
PTC
85U15413
+T
Electrical data:
Motor type:
IE Efficiency class:
Number of poles:
Rated power - P2:
Power (P2) required by pump:
100
90
220
Installation:
Maximum ambient temperature:
Max pressure at stated temp:
100
134
Material code:
Code for rubber:
110
IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE
Impeller:
120
eta
[%]
CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY
THERMISTORS PTC ACCORDING TO DIN 44082
Materials:
Pump housing:
2900 rpm
9.5 m³/h
84.9 m
110 m
10
AUUE
CE,TR
ISO 9906:1999 Annex A
10
A
A
CRT 8-10, 50Hz
Pumped liquid = Water
Liquid temperature = 293 K
Density = 998.2 kg/m³
618
Technical:
Speed for pump data:
Rated flow:
Rated head:
Head max:
Impellers:
Shaft seal:
Approvals on nameplate:
Curve tolerance:
Stages:
Pump version:
Model:
CRT 8-10 A-P-A-E-AUUE
96117229
5700396595825
H
[m]
ø60.1
Product name:
Product No:
EAN number:
Value
26
Description
Lenntech BV - lenntech.com
info@lenntech.com
+31 15 2610900
+31 15 2616289
-
4/7
Company name:
Created by:
Phone:
Fax:
Date:
Description
Value
Minimum efficiency index, MEI ≥:
Net weight:
Gross weight:
0.7
59 kg
69 kg
Printed from Grundfos CAPS [2013.03.059]
Lenntech BV - lenntech.com
info@lenntech.com
+31 15 2610900
+31 15 2616289
-
5/7
Company name:
Created by:
Phone:
Fax:
Date:
Lenntech BV - lenntech.com
info@lenntech.com
+31 15 2610900
+31 15 2616289
-
96117229 CRT 8-10 50 Hz
134
G 1/2
G 1/2
4 x ø13
80
26
618
G 1/2
ø60.1
372
220
130
200
215
248
261
Note! All units are in [mm] unless others are stated.
Disclaimer: This simplified dimensional drawing does not show all details.
Printed from Grundfos CAPS [2013.03.059]
6/7
Company name:
Created by:
Phone:
Fax:
Date:
Lenntech BV - lenntech.com
info@lenntech.com
+31 15 2610900
+31 15 2616289
-
96117229 CRT 8-10 50 Hz
+T
+T
TO AMPLIFIER
RELAY
L1
+T
L2
+T
L3
+T
TO AMPLIFIER
IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE
CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY
THERMISTORS PTC ACCORDING TO DIN 44082
+T
RELAY
L1
L2
L3
Note! All units are in [mm] unless others are stated.
Printed from Grundfos CAPS [2013.03.059]
7/7
Disclaimer: The information about the Grundfos pump in this document may be outdated.
Data may be subject to alterations without further notice.
Please contact us to verify the data above is still accurate/up-to-date.
All information is copyright Grundfos.
info@lenntech.com
www.lenntech.com
tel. +31-15-261.09.00
fax. +31-15-261.62.89
Download