GRUNDFOS DATA BOOKLET CRT 2- 26 A-P-A-E-AUUE 3kW 400D 50Hz Grundfos Pump 96100316 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/CRT02/96100316/CRT-2-26-A-P-A-E-AUUE.html info@lenntech.com tel. +31-15-261.09.00 fax. +31-15-261.62.89 BE > THINK > INNOVATE Company name: Created by: Phone: Fax: Date: Position Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - Qty. Description 1 CRT 2-26 A-P-A-E-AUUE Note! Product picture may differ from actual product Product No.: 96100316 Vertical, non-self-priming, multistage, in-line, centrifugal pump for installation in pipe systems and mounting on a foundation. The pump has the following characteristics: - Impellers, intermediate chambers and outer sleeve are made of - Pump head cover and base are made of - The shaft seal has assembly length according to EN 12756. - Power transmission is via cast iron split coupling. - Pipework connection is via PJE flanges/couplings. The motor is a 3-phase AC motor. Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Water 253 .. 393 K 293 K 998.2 kg/m³ Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Approvals on nameplate: Curve tolerance: 2900 rpm 2.5 m³/h 166 m AUUE CE,TR ISO 9906:1999 Annex A Materials: Pump housing: Impeller: Titanium ASTM B 265 Titanium ASTM B 265 Installation: Maximum ambient temperature: 333 K Max pressure at stated temp: 25 bar / 120 °C Printed from Grundfos CAPS [2013.03.059] 1/7 Company name: Created by: Phone: Fax: Date: Position Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - Qty. Description Flange standard: Pipe connection: Flange size for motor: Electrical data: Motor type: IE Efficiency class: Number of poles: Rated power - P2: Power (P2) required by pump: Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: Efficiency: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): 25 bar / -20 °C PJE 42,4 mm FT130 100LC IE3 2 3 kW 3 kW 3 kW 50 Hz 3 x 380-415 D V 6.3 A 840-920 % 0,87-0,82 2900-2920 rpm IE3 87,1% 87,1-87,1 % 88,0-87,0 % 87,7-85,4 % 55 (Protect. water jets/dust) F Others: Label: Grundfos Blueflux Minimum efficiency index, MEI ≥: 0.7 Net weight: 39.3 kg Gross weight: 44.3 kg Printed from Grundfos CAPS [2013.03.059] 2/7 Company name: Created by: Phone: Fax: Date: Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 96100316 CRT 2-26 50 Hz H [m] CRT 2-26, 50Hz eta [%] Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ 260 240 220 200 180 90 160 80 140 70 120 60 100 50 80 40 60 30 40 20 20 10 0 0 0 0.2 0.4 0.6 0.8 1.0 1.2 P2 [kW] 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 Q [m³/h] NPSH [m] 2.5 10 2.0 8 1.5 6 1.0 4 0.5 2 0.0 0 Printed from Grundfos CAPS [2013.03.059] 3/7 Company name: Created by: Phone: Fax: Date: Description Product name: Product No: EAN number: Technical: Speed for pump data: Rated flow: Rated head: Head max: Impellers: Shaft seal: Approvals on nameplate: Curve tolerance: Stages: Pump version: Model: Materials: Pump housing: Impeller: 2900 rpm 2.5 m³/h 166 m 205 m 26 AUUE CE,TR ISO 9906:1999 Annex A 26 A A CRT 2-26, 50Hz 240 220 200 180 160 140 120 100 80 60 40 20 0 90 80 70 60 50 40 30 20 10 0 0 0.5 1.0 1.5 2.0 2.5 3.0 P2 [kW] Titanium ASTM B 265 Titanium ASTM B 265 A E eta [%] Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ Q [m³/h] NPSH [m] 2 10 1 5 0 0 120 198 335 Material code: Code for rubber: H [m] Value CRT 2-26 A-P-A-E-AUUE 96100316 5700395842746 Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 694 ø42.2 G 1/2 22 50 4 x ø13 100 151 210 Water 253 .. 393 K 293 K 998.2 kg/m³ Printed from Grundfos CAPS [2013.03.059] TO AMPLIFIER RELAY +T L1 +T L2 L3 +T L3 L2 L1 Grundfos Blueflux TO AMPLIFIER RELAY Others: Label: +T Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: Efficiency: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): Motor protec: Motor No: 100LC IE3 2 3 kW 3 kW 3 kW 50 Hz 3 x 380-415 D V 6.3 A 840-920 % 0,87-0,82 2900-2920 rpm IE3 87,1% 87,1-87,1 % 88,0-87,0 % 87,7-85,4 % 55 (Protect. water jets/dust) F PTC 85U15510 180 211 +T Electrical data: Motor type: IE Efficiency class: Number of poles: Rated power - P2: Power (P2) required by pump: G 1/2 +T Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: G 1/2 IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE Flange standard: Connect code: Pipe connection: Flange size for motor: 333 K 25 bar / 120 °C 25 bar / -20 °C PJE P 42,4 mm FT130 CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 44082 Installation: Maximum ambient temperature: Max pressure at stated temp: 4/7 Company name: Created by: Phone: Fax: Date: Description Value Minimum efficiency index, MEI ≥: Net weight: Gross weight: 0.7 39.3 kg 44.3 kg Printed from Grundfos CAPS [2013.03.059] Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 5/7 Company name: Created by: Phone: Fax: Date: Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 180 211 4 x ø13 96100316 CRT 2-26 50 Hz G 1/2 22 G 1/2 G 1/2 120 100 151 210 198 ø42.2 50 694 335 Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details. Printed from Grundfos CAPS [2013.03.059] 6/7 Company name: Created by: Phone: Fax: Date: Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 96100316 CRT 2-26 50 Hz +T +T TO AMPLIFIER RELAY L1 +T L2 +T L3 +T TO AMPLIFIER IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 44082 +T RELAY L1 L2 L3 Note! All units are in [mm] unless others are stated. Printed from Grundfos CAPS [2013.03.059] 7/7 Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date. All information is copyright Grundfos. info@lenntech.com www.lenntech.com tel. +31-15-261.09.00 fax. +31-15-261.62.89