GRUNDFOS DATA BOOKLET CRN150-6 A-F-G-V-HBQV 75kW 3x400D 50Hz Grundfos Pump 95922429 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/CRN150/95922429/CRN-150-6-A-F-G-V-HBQV.html info@lenntech.com tel. +31-15-261.09.00 fax. +31-15-261.62.89 BE > THINK > INNOVATE Company name: Created by: Phone: Fax: Date: Position Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - Qty. Description 1 CRN 150-6 A-F-G-V-HBQV Note! Product picture may differ from actual product Product No.: 95922429 Vertical, multistage centrifugal pump with suction and discharge ports on same the level (in-line) enabling installation in a horizontal one-pipe system. Pump materials in contact with the liquid are in high-grade stainless steel. A cartridge shaft seal ensures high reliability, safe handling and easy service and access. Power transmission is via a split coupling. Pipework connection is via DIN flanges. The pump is fitted with a 3-phase, fan-cooled asynchronous motor. Further product details Steel, cast iron and aluminium components have an epoxy-based coating made in a cathodic electro-deposition (CED) process. CED is a high-quality dip-painting process where an electrical field around the products ensures deposition of paint particles as a thin, well-controlled layer on the surface. An integral part of the process is a pretreatment. The entire process consists of these elements: 1) Alkaline-based cleaning. 2) Zinc phosphating. 3) Cathodic electro-deposition. 4) Curing to a dry film thickness 18-22 my m. The colour code for the finished product is NCS 9000/RAL 9005. Pump A long split coupling connects the pump and motor shaft. It is enclosed in the motor stool by means of two coupling guards. The long coupling makes it possible to replace the shaft seal without removing the motor from the pump. The motor stool connects the pump head and motor. The pump head has a combined 1/2" priming plug and air vent screw. Printed from Grundfos CAPS [2013.03.059] 1/9 Company name: Created by: Phone: Fax: Date: Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - The pump is fitted with a balanced O-ring seal unit with rigid torque transmission system. This seal type is assembled in a cartridge unit which makes replacement safe and easy. Due to the balancing, this seal type is suitable for high-pressure applications. The cartridge construction also protects the pump shaft from possible wear from a dynamic O-ring between pump shaft and shaft seal. Primary seal: - Rotating seal ring material: Carbon graphite, resin-impregnated - Stationary seat material: Silicon carbide (SiC) This material pairing has a very good corrosion resistance and is especially suitable for water up to +90 °C. The seal life will be reduced significantly at temperatures above +90 °C. The material pairing is not recommended for liquids containing particles as this will result in heavy wear on the SiC face. Secondary seal material: FKM (fluorocarbon rubber) FKM has excellent resistance to oils and chemicals. Above 90 °C, FKM should only be used in media without water. The shaft seal is retained in the pump head by a cover and screws. It can be replaced without removing the motor. The chambers and impellers are made of stainless steel sheet. The chambers are provided with a PTFE neck ring offering improved sealing and high efficiency. The impellers have smooth surface, and the shape of the blades ensure a high efficiency. The pump has a stainless steel base mounted on a separate base plate. The base and base plate are kept in position by the tension of the staybolts which hold the pump together. Both the suction and the discharge side of the base have two pressure gauge tappings. The pump is secured to the foundation by four bolts through the base plate. The flanges are fastened to the base by means of locking rings. Motor Printed from Grundfos CAPS [2013.03.059] 2/9 Company name: Created by: Phone: Fax: Date: Position Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - Qty. Description The motor is a totally enclosed, fan-cooled motor with principal dimensions to IEC and DIN standards. The motor is flange-mounted with free-hole flange (FF). Motor mounting designation in accordance with IEC 60034-7: IM B 5 (Code I) / IM 3001 (Code II). Electrical tolerances comply with IEC 60034. The motor efficiency is classified as IE3 in accordance with IEC 60034-30. The motor has thermistors (PTC sensors) in the windings in accordance with DIN 44081/DIN 44082. The protection reacts to both slow- and quick-rising temperatures, e.g. constant overload and stalled conditions. Thermal switches must be connected to an external control circuit in a way which ensures that the automatic reset cannot cause accidents. The motors must be connected to a motor-protective circuit breaker according to local regulations. A variable speed drive makes adjustment of pump performance to any duty point possible. If the motor is to be connected to a variable speed drive, the pump should be ordered with an electrically insulated motor bearing. Grundfos CUE offers a range of variable speed drives. Please find more information in Win-/WebCAPS. Technical data Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Water 273 .. 363 K 293 K 998.2 kg/m³ Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Curve tolerance: 2975 rpm 150 m³/h 134 m HBQV ISO 9906:1999 Annex A Materials: Pump housing: Impeller: Stainless steel DIN W.-Nr. 1.4408 AISI 351 Stainless steel DIN W.-Nr. 1.4401 AISI 316 Installation: Maximum ambient temperature: 328 K Max pressure at stated temp: 30 bar / 90 °C 30 bar / 0 °C Flange standard: DIN Pipe connection: DN 125 Pressure stage: PN 25/40 Flange size for motor: FF500 Electrical data: Motor type: IE Efficiency class: Number of poles: Rated power - P2: Power (P2) required by pump: Printed from Grundfos CAPS [2013.03.059] SIEMENS IE3 2 75 kW 75 kW 3/9 Company name: Created by: Phone: Fax: Date: Position Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - Qty. Description Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: Efficiency: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): 50 Hz 3 x 380-420D/660-725Y V 136-122/78,0-70,0 A 680-680 % 0,9 2975 rpm IE3 94,7% 94,7-94,7 % 94,8-94,8 % 94,1-94,1 % 55 (Protect. water jets/dust) F Others: Net weight: Gross weight: 736 kg 900 kg Printed from Grundfos CAPS [2013.03.059] 4/9 Company name: Created by: Phone: Fax: Date: Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 95922429 CRN 150-6 50 Hz H [m] CRN 150-6, 50Hz eta [%] Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ 220 200 180 160 140 120 100 100 80 80 60 60 40 40 20 20 0 0 0 20 40 60 P2 [kW] 80 100 120 140 160 180 Q [m³/h] NPSH [m] 80 16 70 14 60 12 50 10 40 8 30 6 20 4 10 2 0 0 Printed from Grundfos CAPS [2013.03.059] 5/9 Company name: Created by: Phone: Fax: Date: Description Product name: Product No: EAN number: Value CRN 150-6 A-F-G-V-HBQV 95922429 5700838936506 Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - H [m] CRN 150-6, 50Hz eta [%] Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ 220 200 180 160 Printed from Grundfos CAPS [2013.03.059] 100 150 Q [m³/h] P2 [kW] NPSH [m] 15 40 10 20 5 0 0 100 150 60 28 18 8x 4x 472 380 F (DIN) PN25-40/DN 125 550 380 344 275 G 1/2 G 1/2 L2 L3 +T L1 TO AMPLIFIER RELAY TO AMPLIFIER RELAY +T L1 +T L2 L3 +T +T 736 kg 50 +T Others: Net weight: 0 0 432 SIEMENS IE3 2 75 kW 75 kW 50 Hz 3 x 380-420D/660-725Y V 136-122/78,0-70,0 A 680-680 % 0,9 2975 rpm IE3 94,7% 94,7-94,7 % 94,8-94,8 % 94,1-94,1 % 55 (Protect. water jets/dust) F PTC 81U15340 20 0 555 Electrical data: Motor type: IE Efficiency class: Number of poles: Rated power - P2: Power (P2) required by pump: Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: Efficiency: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): Motor protec: Motor No: 40 20 IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE Water 273 .. 363 K 293 K 998.2 kg/m³ 60 40 CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 44082 Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: 80 60 820 Flange standard: Connect code: Pipe connection: Pressure stage: Flange size for motor: 328 K 30 bar / 90 °C 30 bar / 0 °C DIN F DN 125 PN 25/40 FF500 100 80 1642 Installation: Maximum ambient temperature: Max pressure at stated temp: 100 180 Material code: Code for rubber: 120 43 Impeller: Stainless steel DIN W.-Nr. 1.4408 AISI 351 Stainless steel DIN W.-Nr. 1.4401 AISI 316 G V 140 220 Materials: Pump housing: 2975 rpm 150 m³/h 134 m 6 HBQV ISO 9906:1999 Annex A 6 A A 270 Technical: Speed for pump data: Rated flow: Rated head: Impellers: Shaft seal: Curve tolerance: Stages: Pump version: Model: 6/9 Company name: Created by: Phone: Fax: Date: Description Value Gross weight: 900 kg Printed from Grundfos CAPS [2013.03.059] Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 7/9 Company name: Created by: Phone: Fax: Date: Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 95922429 CRN 150-6 50 Hz 432 820 555 550 F (DIN) PN25-40/DN 125 8x 28 4x 18 180 270 G 1/2 220 1642 G 1/2 100 43 275 344 380 150 380 472 Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details. Printed from Grundfos CAPS [2013.03.059] 8/9 Company name: Created by: Phone: Fax: Date: Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 95922429 CRN 150-6 50 Hz +T +T TO AMPLIFIER RELAY L1 +T L2 +T L3 +T TO AMPLIFIER IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 44082 +T RELAY L1 L2 L3 Note! All units are in [mm] unless others are stated. Printed from Grundfos CAPS [2013.03.059] 9/9 Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date. All information is copyright Grundfos. info@lenntech.com www.lenntech.com tel. +31-15-261.09.00 fax. +31-15-261.62.89