GRUNDFOS DATA BOOKLET CRK 4-140 A-W-A-BUBV 85805710 3X230D Grundfos Pump 41907114 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/CRK04/41907114/CRK-4-140-14-A-W-A-AUUV.html info@lenntech.com tel. +31-15-261.09.00 fax. +31-15-261.62.89 BE > THINK > INNOVATE Company name: Created by: Phone: Fax: Date: Position Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - Qty. Description 1 CRK 4-140/14 A-W-A-AUUV Note! Product picture may differ from actual product Product No.: 41907114 Multistage, immersible, self-priming, centrifugal pump for vertical installation in tanks etc. The pump has the following characteristics: - Installation length according to DIN 5440. - Impellers, intermediate chambers and spline shaft are made of Stainless steel. - Mechanical shaft seal according to EN 12756. - Power transmission via cast iron split coupling. The motor is a 3-phase AC motor. Immersion depth: 493 mmmm Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Water 263 .. 363 K 293 K 998.2 kg/m³ Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Curve tolerance: 2900 rpm 6 m³/h 90.5 m AUUV ISO 9906:1999 Annex A Materials: Pump head: Impeller: Cast iron EN-JL1030 ASTM A48-30 B Stainless steel DIN W.-Nr. 1.4301 AISI 304 Installation: Maximum ambient temperature: 333 K Pipe connection: G 1 1/4 Flange size for motor: FT130 Printed from Grundfos CAPS [2013.03.059] 1/6 Company name: Created by: Phone: Fax: Date: Position Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - Qty. Description Electrical data: Motor type: Number of poles: Rated power - P2: Power (P2) required by pump: Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): 100LC 2 3 kW 3 kW 50 Hz 3 x 220-240 D/380-415 Y V 11,0/6,30 A 840-920 % 0,87-0,82 2900-2920 rpm 84,6-84,6 % 86-86 % 85,5-84 % 55 (Protect. water jets/dust) F Others: Minimum efficiency index, MEI ≥: 0,70 Net weight: 34.9 kg Printed from Grundfos CAPS [2013.03.059] 2/6 Company name: Created by: Phone: Fax: Date: Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 41907114 CRK 4-140/14 50 Hz H [m] CRK 4-140/14, 50Hz eta [%] Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ 150 140 130 120 110 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0 0.5 1.0 1.5 2.0 2.5 P2 [kW] 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 Q [m³/h] NPSH [m] 2.5 5 2.0 4 1.5 3 1.0 2 0.5 1 0.0 0 Printed from Grundfos CAPS [2013.03.059] 3/6 Company name: Created by: Phone: Fax: Date: Technical: Speed for pump data: Rated flow: Rated head: Impellers: Shaft seal: Curve tolerance: Stages: Pump version: Model: Materials: Pump head: CRK 4-140/14 A-W-A-AUUV 41907114 5708601063374 2900 rpm 6 m³/h 90.5 m 14 AUUV ISO 9906:1999 Annex A 14 A B Material code: Cast iron EN-JL1030 ASTM A48-30 B Stainless steel DIN W.-Nr. 1.4301 AISI 304 A Installation: Maximum ambient temperature: Connect code: Pipe connection: Flange size for motor: 333 K W G 1 1/4 FT130 Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Water 263 .. 363 K 293 K 998.2 kg/m³ Electrical data: Motor type: Number of poles: Rated power - P2: Power (P2) required by pump: Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): Motor protec: Motor No: 100LC 2 3 kW 3 kW 50 Hz 3 x 220-240 D/380-415 Y V 11,0/6,30 A 840-920 % 0,87-0,82 2900-2920 rpm 84,6-84,6 % 86-86 % 85,5-84 % 55 (Protect. water jets/dust) F PTC 85D05510 Others: Minimum efficiency index, MEI ≥: Net weight: 0,70 34.9 kg CRK 4-140/14, 50Hz eta [%] Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 100 90 80 70 60 50 40 30 20 10 0 0 1 2 3 4 5 6 7 P2 [kW] Q [m³/h] NPSH [m] 2 4 1 2 0 0 180 160 140 4 x 7.5 32 931 493 438 160 178 CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 44082 L2 L3 +T L1 +T TO AMPLIFIER RELAY +T TO AMPLIFIER RELAY +T L1 +T L2 L3 +T IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE Printed from Grundfos CAPS [2013.03.059] 103 G 1 1/4 Impeller: H [m] 100 Product name: Product No: EAN number: Value 110 Description Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 4/6 Company name: Created by: Phone: Fax: Date: Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 41907114 CRK 4-140/14 50 Hz 178 438 110 160 100 103 931 32 G 1 1/4 4 x 7.5 493 140 160 180 Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details. Printed from Grundfos CAPS [2013.03.059] 5/6 Company name: Created by: Phone: Fax: Date: Lenntech BV - lenntech.com info@lenntech.com +31 15 2610900 +31 15 2616289 - 41907114 CRK 4-140/14 50 Hz +T +T TO AMPLIFIER RELAY L1 +T L2 +T L3 +T TO AMPLIFIER IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 44082 +T RELAY L1 L2 L3 Note! All units are in [mm] unless others are stated. Printed from Grundfos CAPS [2013.03.059] 6/6 Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date. All information is copyright Grundfos. info@lenntech.com www.lenntech.com tel. +31-15-261.09.00 fax. +31-15-261.62.89