Document 10917634

advertisement
Weschler Premo BarGraph Meter/Controller
The Premo Bargraph Controller is
a full featured, high resolution
meter for display and control of
process parameters. A wide
range of input modules measure
electrical signals, sensors and
transducers. Analog and digital
outputs easily connect to remote
indicators or a plant SCADA system. Up to 6 setpoints can be
programmed to operate within
the span of the selected input
module. PID control is available
from the first two setpoints.
PC
Specifications on next page.
ORDERING INFORMATION CONTINUED
D
ORDERING INFORMATION
A
B
C
D
A
B
C
D
E
F
G
H
I
Style
C
4 1/2" Switchboard
D
12" Edgewise Vertical
G
6" Edgewise Vertical
Bar Color
R
Red
G
Green
T
Tricolor
Digital Display Color
R
Red
G
Green
Input (partial list)
DBQ
DC, 20/50/100/200mV w/24V Excitation
DCQ
DC, 2/20/200mA w/24V Exc
DGQ
DC, 1A
DDQ
DC, 5A
ABQ
AC, 200mV/2V/20V, scaled RMS
AAQ
AC, 200/600V, scaled RMS
AGQ
AC, 200mV/2V/20V, True RMS
AFQ
AC, 200/600V, True RMS
ACQ
AC, 2/20/200mA, scaled RMS
ADQ
AC, 1 Amp, scaled RMS
AEQ
AC, 5 Amp, scaled RMS
AHQ
AC, 2/20/200mA, True RMS
AJQ
AC, 1A, True RMS
AKQ
AC, 5A, True RMS
PDQ
Process 2/5/10/20/200V/2mA/20mA/Custom
TMP
Thermocouple, J/K/R/S/T/B/N
PG
PD
To Order—Insert Code for Each Letter to Select Catalog Number.
Order Example: PCRGDCQ1A5CXXXX
PC
CONTROLLERS
Direct Measurement of:
DC Current
AC Current
DC Voltage
AC Voltage
Frequency
Power
Process Loops
Thermocouples
RTDs
Load Cells/ Strain Gauges
LVDTs
Pressure
Speed Pickups/ RPM
Resistance/Potentiometers
Quadrature
Event Counting
L
L
•Datalogging & PID control
functions
•Cross channel calculations
with multi-channel input
modules
•Front panel & external
dimming
•Enhanced table calibration for
tank level, square law & other
non-linear measurements
•Optional SD memory card for
long term data logging
•3 case styles
L
•101 segment red, green or
tricolor bar
•6 digit alpha-numeric readout
•Rugged steel case, standard
switchboard mounting
•6 assignable relays with
tracking, latching & manual
reset functions
•Single or dual analog
retransmit
•ASCII, Modbus Serial &
Ethernet communications
•Wide variety of input modules
NEW
J
E
F
G
H
I
J
Input continued
THP
RTD, 100Ω Pt, 2/3/4-wire
GHQ
Direct Pressure, 30 psi differential/gage
GKQ
Direct Pressure, 100 psi differential/gage
SBQ
Pressure 5/10VDC Exc., 2/20 mV/V, 4/6-wire
EAP
Line Frequency, 50-500VAC
FAP
Universal Frequency / RPM / Up Down Counter
CAP
Quadrature Counter
REP
Resistance, 2/3/4-wire, 200/2k/20kΩ
KAP
Single Phase Power, 300V/1A from CT
KBP
Single Phase Power, 300V/5A from CT
KCP
DC Watts, 200V/50mV from shunt
PAD
Dual Process Loop, 4-20mA
DCD
Dual DC, 2mA
DBD
Dual DC, 2V
TAD
Dual Thermocouple, J/K/R/T
FAD
Dual Frequency
FBD
Dual Counter
Power
1
85-265VAC/95-370VDC
2
15-48VAC/10-72VDC
Retransmit (analog output)
A
Isolated 4-20mA or 0-20mA, scalable
V
Isolated 0-10VDC, scalable
D
Isolated Dual 0-10VDC, scalable
X
None
Communications
2
Isolated ASCII Code RS-232
4
Isolated ASCII Code RS-485
5
Isolated ModBus Protocol RS-232
6
Isolated ModBus Protocol RS-485
8
Ethernet ACSII TCP/IP
9
Ethernet ModBus TCP/IP
Relays (partial list)
C
Two 10A Form C
D
Two 10A Form C & Two 5A Form A
H
Six Form A
X
None
Memory
A
1M with Real time clock
X
Standard
Options (2 digits)
D
Continuous external dimming
W
Spray tight front
X
None
4
Weschler Premo BarGraph
Meter /Controller
Yokogawa Temperature
Controllers
Continued from previous page
• On/Off, PID, Heat/Cool & Limit Control
• Dynamic auto tune & "SUPER"
overshoot suppression
• Compact 1/16 DIN package
• Large LED display
• IP65 splash & dust-proof front panel
• Optional analog retransmit of
measured value
UT130
• Timer function (UT150)
• Optional heater burnout alarm & two alarm output relays
• Optional 24V AC/DC power supply
• Optional RS-485 MODBUS communication
SPECIFICATIONS
CONTROLLERS
Digital Display Range:
-199999 to 999999
Decimal Point:
Five positions, front panel selectable
Update Rate:
3 to 10 times per second
Display Dimming:
8 level from front panel;
continuous external option
A/D Converter:
Bipolar 17 bit (optional 23 bit)
Counter Functions:
Two built-in Up/Down counters
Data Logging:
Logging with date/time (Memory option A)
Trigger:
Time interval, setpoint, manual
Data storage:
Non-volatile EEPROM
Linearization:
4 selectable 32 point tables, cascadeable
Math Functions:
Sum, difference, ratio or the product
of two inputs
Offset Functions:
Tare, compensation and calibration
Peak and Valley:
Min/Max storage with front panel recall
Digital Comm:
RS-232, RS-485, Ethernet
Setpoint Functions:
Hysteresis, on/off delays, one shot, pulse and
repeat timers, latching, dual PID, setpoint tracking,
logging trigger
Signal Processing:
Timer:
Totalalizer:
Analog Output:
Resolution:
Compliance:
Real Time Clock:
Power:
(DC to 400Hz)
Operating
Temperature:
Software:
Averaging, smart filter, rounding, square root
Time-up, time-down, or real-time clock modes
Two, for Total and Batch Total
Isolated 16-bit, accuracy 0.02% FS
0.4µA on current, 250µV on voltage
500Ω max. for current, 500Ω min. for voltage
Optional, 15 yr Lithium battery backup
85-265VAC / 95-370VDC @ 5W max
15-48VAC / 10-72 VDC @ 5W max
0-50°C (32-122°F),
<95% (non-condensing) at 40°C
PC-based configuration utility
Style C
Bar:
Digits:
Case:
Size:
Mounting:
Style G
Bar:
Digits:
Case:
Size:
Mounting:
Style D
Bar:
Digits:
Case:
Size:
Mounting:
5
7.25" length, 235° arc, ±60° viewing angle
0.43" (10.9mm) height
Steel housing, molded front & rear bezel
4.43" square bezel, 4.75" behind panel
Fits standard ANSI 4" switchboard cutout
10" length, ±60° viewing angle
0.31" (7.9mm) height
Steel housing, molded rear bezel
1.7" x 6.04", 7" behind panel
Fits standard ANSI 6" switchboard cutout
4" length, ±60° viewing angle
0.43" (10.9mm) height
Steel housing, metal front, molded rear bezel
3.15" x 12.9", 7.8" behind panel
Fits Bailey draft gauge cutout
L
SPECIFICATIONS
Input:
RTD:
T/C (all models):
T/C (UT15O models):
DC In (UT15O models):
Basic Accuracy:
T/C:
RTD:
DC:
Setpoints:
Timer (UT15O models):
Retransmit:
Contact Input:
Contact Output:
Alarm:
Display:
Power:
Approvals:
Temperature:
Dimensions:
3-wire Pt100
J, K, T, E, L, U
R, S, B, N, platinel
0-100mV, 0-5V, 1-5V, 0-10V
±2°C ±1d
±1°C ±1d
±0.3% ±1d
1 on UT130, 2 on UT150
Up to 100 hours
4-20mA
2 points for SP select, run/stop or timer
2 for alarm, heater disconnect or timer
25 types
UT130: single 0.7" 3-digit LED
UT150: dual (red/green) 4-digit LED
100-240VAC, 8VA
UL, CSA, CE
0-50°C operating
48x48x100mm
ORDERING INFORMATION
To Order—Insert Code for Each Letter to Select Catalog Number
Example: UT130-RN/AL/RS
A B C
A
Model
UT130
Temperature Controller
UT150
Temperature & Voltage Controller
UT150L Limit Controller
B
Control
/RN
Relay output
/VN
Pulse output3
/AN
4-20mA output (UT150 only)3
/RR
Heat/cool relay outputs3
/VV
Heat/cool pulse outputs3
/AA
Heat/cool 4-20mA outputs (UT150 only)3
C
Options
/AL
Alarm output (2 points)
/V24
24V AC/DC power supply 3
/HBA
Heater disconnect alarm 2 3
/RET
Analog retransmit (UT150 only)
/RS
RS-485 Communications
/EX
Two contact input (UT150 only) 1
1
cannot be ordered with communications when heat/cool control specified
2
cannot be ordered with communcations
3
not available on UT150L
NEW
Yokogawa Advanced Controllers
Universal Input:
With built-in Ladder Sequence Control, the UT
Advanced controllers can replace a small PLC to: Thermocouple: Type K, J, T, B, S, R, N, E, L, U, W,
PL-2, PR20-40, W97Re3, W75Re25
• Monitor and control external machinery
RTD:
Pt100, JPt100 (3-wire except 3/4• Implement digital input/output logic
wire on 55A)
functions.
DC Voltage: 0.4 to 2V, 1 to 5V, 0 to 2V, 0 to 10V,
Sequence control and PID control can be
performed simultaneously.
-10 to 20mV, 0 to 100mV
DC Current: 4 to 20mA, 0 to 20mA
The Fuzzy Logic Control functions deliver fine
Standard Power Supply: 100-240 V AC
control and reduce overshoot or hunting.
PV Display: 5 digits, 0.1% of FS accuracy
8 Built-in Control Types
• PID control
• ON/OFF control (1 point hysteresis)
• ON/OFF control (2 point hysteresis)
• Two-position, two-level control
• Heating/cooling control
• Sample PI control
• Batch PID control
• Feedforward control
8 Built-in Control Modes
• Single-loop control
• Cascade primary-loop control
• Cascade secondary-loop control
• Cascade control
• Loop control for backup
• Loop control with PV switching
• Loop control with PV auto-selector
• Control with PV-hold
To Order—Insert Code for Each Letter to
Select Catalog Number.
Model
Size
# of Analog Inputs Std (Max)
# of SPs (PIDs) Max
# of Control Modes Max
# of Control Types Max
Relay, Pulse, Current Output
# of Analog Outputs Std (Max)
# of Digital Inputs Std (Max)
# of Alarms Max
# of Digital Outputs Std (Max)
RS-485 communication (Max)
Ethernet communication
Split Computation Output
Ratio & Square Root Extraction
Remote SP Function
Heater Break Alarm Function
Ladder Sequence (max. steps)
Control Scan Period (msec)
Bar graph display (Number)
5b
UT55A
1/4 DIN
1 (4)
8
8
8
2 (3)
3 (9)
8
3 (18)
(2)
Std type
(500)
UP55A— A
A Control
0
1
2
B Functions
0
1
UT52A
1/8 DIN
1 (2)
8
8
8
2 (3)
3 (5)
8
3 (5)
(1)
—
Std type
(500)
(2)
ORDERING INFORMATION
UM33A— A
Standard type
Position proportional type
Heating/cooling type
None
Remote (1 additional aux. analog) input,
1 additional DI
2
RS-485 (Max.19.2 kpbs, 2/4-wire)
3
10 additional DOs
4
3 additional aux. analog inputs, 2 DIs &
5 DOs to be deleted
C Network Communications
0
None
1
RS-485(Max.38.4 kbps, 2/4-wire)
2
Ethernet (with serial gateway function)
D Case Color
10
Light Gray
11
Dark Gray
E Options
/DR
Additional direct input (TC & 3/4-wire
RTD), current input to Remote (1 additional
aux. analog) input, 1 DI to be deleted
/HA
Heater break alarm
/DC
Power supply 24 V AC/DC
/CT
Coating
50/100/200
(2)
UM33A
C _ D — 00 / E
B
UP55A
UT35A
UT32A
•Scrolling text
•Programmable function keys
•RS-485 (Modbus) & Ethernet
communications
•3 year warranty
UT35A
UT32A
1/4 DIN
1/8 DIN
1
1
4
4
1
1
5
5
2
2
2 (7)
2 (4)
4
4
3 (8)
3 (5)
(1)
(1)
—
—
—
—
—
—
—
Std or Heat/cool
(300)
(300)
UP55A
1/4 DIN
1 (4)
8
5
4
2 (3)
3 (9)
8
8 (18)
(2)
Std type
(500)
UP35A
1/4 DIN
1
4
1
4
2
3 (8)
2
3 (8)
(1)
—
—
—
Std type
(300)
UM33A
1/8 DIN
1
—
—
—
—
1
2
8
3 (9)
(1)
—
—
—
200
200
100/200
200
50/100/200
(1)
(1)
(2)
(1)
—
See complete data sheet for additional options and ordering
information for UT55A, UT52A, UP35A models.
B _
C / D
A Control
0
Standard type
B Functions
00
None
10
1 additional DO (form C relay) + RS-485
comm (Max. 38.4kbps, 2/4-wire)
20
1 additional DO (form C relay)
30
6 additional DOs (form C relay; 1 point
& open collector; 5 points)
C Case Color
10
Light Gray
11
Dark Gray
D Options
/LP 24 V DC loop power supply
/DC Power supply 24 V AC/DC
/CT Coating
UT32A— A
B _
C — 00 / D
A Control
0
Standard type
1
Position proportional type
2
Heating / cooling type
B Functions
00
None
10
RS-485 comm (Max.38 kbps, 2/4-wire)
20
2 additional DIs & 2 additional DOs
C Case Color
10
Light Gray
11
Dark Gray
D Options
/LP 24 V DC loop power supply
/HA Heater break alarm
/DC Power supply 24 V AC / DC
/CT Coating
UT35A— A
B
C _ D — 00 / E
A Control
0
Standard type
1
Position proportional type
2
Heating / cooling type
B Functions
0
None
1
2 additional DIs and 2 additional DOs
2
5 additional DIs and 5 additional DOs
C Network Communications
0
None
1
RS-485 (Max.38.4 kbps, 2/4-wire)
2
Ethernet (with serial gateway function)
D Case Color
10
Light Gray
11
Dark Gray
E Options
/LP 24 V DC loop power supply
/HA Heater break alarm
/DC Power supply 24 V AC / DC
/CT Coating
CONTROLLERS
•8 built-in PID control modes
•8 built-in PID control types
•Ladder sequence control
•Fuzzy logic control
•Active color LCD display
Digital Indicating Controllers: UT55A, UT52A, UT35A, UT32A
Program Controllers: UP55A, UP35A
Digital Indicator with Alarms: UM33A
Newport Temperature and Process Controllers
PLATINUM Series
• High accuracy, high performance (24 bit, 20 samples/sec)
• Full autotune PID with fuzzy logic adaptive control
• Universal input (T/C, RTD, thermistor, process V & mA)
• Up to 99 programs with 16 ramps and soaks and chaining
• Bright 3-color (red/green/amber) 9 segment LED display
• Dual display (Pt16D & Pt32D)
• Analog, pulse and relay output options
• USB host communications standard
• Optional Ethernet & RS232/485 with Modbus
• No jumpers to set, totally firmware configurable
• NEMA 4, IP65 front (NEMA 1 on 1/8 DIN size)
®
SPECIFICATIONS
INPUTS
Input Types:
Current Input:
Voltage Input:
Thermocouple Input:
RTD Input:
Thermistor Input:
Configuration:
Basic Accuracy:
Resolution:
Input Impedances:
Process Voltage:
Process Current:
Thermocouple:
Auxiliary Input:
A/D Conversion:
Reading Rate:
Digital Filter:
CMRR:
Excitation:
Setpoint Adjustment:
CONTROL MODES
Action:
Auto-Tune:
Adaptive Tune:
Pt8D
Pt16D
Pt32
Control Modes:
Cycle Time:
Ramp and Soak:
ORDERING INFORMATION
Model No.
Output 1
Single Display Models
Pt*-330
SPDT Relay
Pt*-220
0.5 A SSR
Pt*-304
SPDT Relay
Pt*-305
SPDT Relay
Pt*-440
DC Pulse
Pt*-224
0.5 A SSR
Pt*-225
0.5 A SSR
Pt*-144
SPST Relay
Pt*-145
SPST Relay
Pt*-444
DC Pulse
Pt*-445
DC Pulse
Dual Display Models
Pt**D-330
SPDT Relay
Pt**D-220
0.5 A SSR
Pt**D-304
SPDT Relay
Pt**D-305
SPDT Relay
Pt**D-440
DC Pulse
Pt**D-224
0.5 A SSR
Pt**D-225
0.5 A SSR
Pt**D-144
SPST Relay
Pt**D-145
SPST Relay
Pt**D-444
DC Pulse
Pt**D-445
DC Pulse
Output 2
Output 3
SPDT Relay
0.5 A SSR
DC Pulse
Analog
DC Pulse
0.5 A SSR
0.5 A SSR
DC Pulse
DC Pulse
DC Pulse
DC Pulse
—
—
—
—
—
DC Pulse
Analog
DC Pulse
Analog
DC Pulse
Analog
SPDT Relay
0.5 A SSR
DC Pulse
Analog
DC Pulse
0.5 A SSR
0.5 A SSR
DC Pulse
DC Pulse
DC Pulse
DC Pulse
—
—
—
—
—
DC Pulse
Analog
DC Pulse
Analog
DC Pulse
Analog
Segment Times:
Options
-EIP
Ethernet with embedded web server (not available on Pt32)
-C24
Isolated RS232/RS485 @ 1200 to 115,200 baud
-DC
12-36 Vdc power; 20-36 Vdc for dual display or Ethernet option
* Insert 32 for 1/32 DIN size, 16 for 1/16 DIN size, 8 for 1/8 DIN size
** Insert 16 for 1/16 DIN size, 8 for 1/8 DIN size
Example: Pt16D-330-C24-DC
NEW
CONTROL OUTPUTS
Analog Output:
DC Pulse:
SPST Relay:
SPDT Relay:
SSR:
Thermocouple, RTD, Thermistor, DC Voltage, DC Current
4 to 20 mA, 0 to 24 mA scalable
-100 to 100 mV, -1 to 1 V, -10 to 10 Vdc scalable
K, J, T, E, R, S, B, C, N
100/500/1000Ω Pt, 2-, 3- or 4-wire; 0.00385, 0.00392
(100Ω only), or 0.003916 (100Ω only) curves
2252Ω, 5kΩ, 10kΩ
Differential, bipolar
0.03% FS process, 0.3°C RTD, 0.2°C thermistor,
0.4°C J/K/T/E/C/N, 0.5°C R/S/B
0.1° temperature; 10 μV process
10MΩ for ±100 mV, 1MΩ for other voltage ranges
5Ω
10kΩ max
3.5kΩ for 0-10 V, 50kΩ for 0-1 V, 50Ω for Current
24-bit sigma delta
20 samples per second
Programmable from 0.05 seconds to 6.4 seconds
120 dB
5, 10, 12, and 24 Vdc @ 25 mA, firmware selectable
-9999 to +9999 counts
Reverse (heat), direct (cool), or heat/cool
Operator initiated from front panel
User selectable; fuzzy logic continuous PID tuning
optimization
ON/OFF or the following time/amplitude proportional control
modes; selectable manual or auto PID, proportional,
proportional with integral, proportional with derivative
0.1 to 199 seconds
Up to 99 saved ramp & soak programs, up to 8 ramp & 8
soak segments with individually selectable events per program
00.00 to 99.59 (HH:MM) or 00.00 to 99.59 (MM:SS)
Non-isolated, Proportional 0 to 10 Vdc or 0 to 20 mA;
500Ω max; programmable for control or retransmission;
accuracy is 0.1% of full scale
Non-isolated; 10 Vdc at 20 mA
Single pole, single throw mechanical relay, 250 Vac or
30 Vdc at 3 A (resistive load)
Single pole, double throw mechanical relay, 250 Vac or
30 Vdc at 3 A (resistive load)
20 to 265 Vac at 0.05-0.5 A (resistive load);
COMMUNICATIONS (USB standard, Serial and Ethernet optional)
Connection:
USB: Female micro-USB
Ethernet: Standard RJ45
Serial: Screw terminals
USB:
USB 2.0 host or device
Ethernet (IEEE 802.3): 10/100 Base-T autoswitching, TCP/IP, ARP, HTTPGET
Serial:
Software selectable RS232 or RS485; programmable
1200 to 115200 baud
Protocols:
Newport ASCII, Modbus® ASCII/RTU
ISOLATION (1min test)
Power to Input/Output:
Power to Relays/SSR:
Relay to Relay/SSR:
SSR to Relay/SSR:
RS232/RS485 to I/O:
GENERAL
Operating Temp.:
Line Voltage:
Low Voltage Option:
2300 Vac; 1500 Vac (low voltage/power option)
2300 Vac
2300 Vac
2300 Vac
500 Vac
0 to 50°C (32 to 122°F), 90% RH non-condensing
90-240 Vac ±10%, 50-400 Hz, 110-375 Vdc; 5W max.
12-36 Vdc power; 20-36 Vdc for dual display or Ethernet
(not CE or UL)
Display:
4-digit, 9-segment LED
Case depth:
127mm
Optional PT-USB-CABLE is a NEMA4 rated panel mount USB connector with 12"
(304mm) cable that connects to the controller’s USB port. Includes protective end cap.
5c
Extech PID Controller
• Dual 4-digit LED displays for process & setpoint values
• User-friendly menus and tactile keypad
• Fuzzy Logic PID offers intuitive control
• Manual mode overrides automatic control
• One-touch Auto Tuning for quick setup and precise control
• Single stage Ramp and Soak program with
Ramp-to-Setpoint Limit
• Soft Start feature for smooth process start-up
• Accepts thermocouple and RTD inputs
• Select input type from display menu – no hardware change
• Two ‘Latching’ relays with 8 Alarm modes & advanced
Timer modes
Inputs
Type K
Type J
Type B
Type T
Type E
Type R, S
Type N
Type C
Pt100 RTD (DIN)
Pt100 RTD (JIS)
Control/Alarm Relay
DC Current Output
Accuracy
Sampling Time
LED Status
Control Modes
Front Panel
Power Supply
•
•
•
•
•
•
High Accuracy ±0.5°C, 0.03% Rdg.
Extended 5-Year Warranty
Universal Inputs
Relay, SSR, DC Pulse Outputs
Ramp to Setpoint
Universal Power Supply,
90–250 VAC or VDC
• Dual Output and Dual Alarm
• Optional RS-232, RS-485, Isolated
Analog Output or Remote Setpoint
CONTROLLERS
L
48VFL
Newport Autotune Process &
Temperature Controller
▲ ICN77
SPECIFICATIONS
Input
Input Types:
Thermocouple, RTD, analog voltage, analog current
Thermocouples: J, K, T, E, R, S, B, C, N, and J DIN
Accuracy:
±0.5°C temp; 0.03% rdg. process
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: ICN77-5-3-2-A2
A – B – C – D – E
SPECIFICATIONS
A
-58 to 2498°F (-50 to 1370°C)
-58 to 1832°F (-50 to 1000°C)
32 to 3272°F ( 0 to 1800°C)
-454 to 752°F (-270 to 400°C)
-58 to 1382°F (-50 to 750°C)
32 to 3182°F ( 0 to 1750°C)
-58 to 2372°F (-50 to 1300°C)
-58 to 3272°F (-50 to 1800°C)
-328 to 1652°F (-200 to 850°C)
-328 to 1202°F (-200 to 650°C)
5 Amp @ 110V, SPST (resistive load)
4-20mA (resistive); Impedance < 600 ohms
T/C: ±1.8°F (1°C); RTD: ±0.36°F (0.2°C)
4 samples per second
Alarm and Control output status
Fuzzy Logic enhanced three-term PID with Auto Tune
• Proportional Band 0 to 300.0%
• Integral time 0 to 3600 seconds
• Derivative time 0 to 900 seconds
• Hysteresis 0.0 to 200.0 or 0.0 to 2000
• Cycle time 1 to 100 seconds
Lexan, Drip/Dust proof, IP63
90 to 264 VAC; 50/60 Hz (< 5VA)
B
C
D
E
F
– F
Basic Unit
ICN77 1/16 DIN Controller
Configuration
5
NEMA-4/IP65 Face with DIN Cutout
R5
Square Bezel with 1 3/4" Round Cutout
Primary Output
2
SSR (1A @ 120/240 VAC)
3
SPDT Relay (5A @ 120 VAC)
4
Pulsed 0–10 VDC @ 20 mA Max
5
Non-isolated 1–10V or 0–20 mA
Second Output
0
None
2
SSR (1A @ 120/240 VAC)
3
SPDT Relay (5A @ 120 VAC)
4
Pulsed 0–10 VDC @ 20 mA Max
Options
A2
Second Alarm Relay
C2
Isolated RS-232
C4
Isolated RS-485
PV
Isolated Analog Output
RSP
Remote Setpoint
Optional Power–Include Only if Required
DC
10–34 VAC/VDC Power
ORDERING INFORMATION—ACCESSORIES
ORDERING INFORMATION
48VFL11
48VFL13
96VFL11
96VFL13
1/16 DIN Temperature PID Controller with one relay output
1/16 DIN Temperature PID Controller with 4-20mA output
1/4 DIN Temperature PID Controller with two relay outputs
1/4 DIN Temperature PID Controller with 4-20mA output
SPC-116-S
TP4
TP6
Splash-Proof Cover for 1/16 DIN Controllers
Trim Plate Adapter to Install 1/16 DIN
Meter in Existing 1/4 DIN Panel Cutout
Trim Plate Adapter to Install 1/16 DIN
Meter in Existing 1/8 DIN Panel Cutout
6
NEW
ATC Temperature Controller
• Dual 4-digit, seven segment LED display
• PID & On/Off control
• Thermocouple and RTD input
• °C / °F selectable
• Two setpoints
• Field selectable Control Output (Relay or SSR)
• Auxiliary Output - factory installed Relay or SSR
• 1/16 DIN Case, IP65 Front
INPUT RANGES
1°
ATC550
SPECIFICATIONS
Inputs:
Sampling Time:
Input Filter (FTC):
Temperature Unit
Indication Accuracy:
Resolution
0.1°
Pt100 RTD
°C -150 to 850
°F -238 to 1562
Thermocouple
J
°C -199 to 750
°F -328 to 1382
K
°C -199 to 1350
°F -328 to 2462
T
°C -199 to 400
°F -328 to 750
R&S °C 0 to 1750
°F 32 to 3182
-150 to 850
-199 to 999
-199 to 750
-199 to 999
-199 to 999
-199 to 999
-199 to 400
-199 to 750
N/A
N/A
ORDERING INFORMATION
ATC550S00000
ATC550S10000
ATC550 Temperature Controller with Aux Relay output
ATC550 Temperature Controller with Aux 12VDC SSR output
Thermocouple (J,K,T,R,S) / 3-wire RTD (Pt100)
250 ms
0.2 to 10.0 seconds
°C / °F selectable
For J, K & T inputs: 0.25% of F.S. ±1°
For R & S inputs: 0.5% of F.S. ±2°
For RTD inputs: 0.1% of F.S. ±1°
Digital Filter:
Programmable from 0.05 seconds to 6.4 seconds
Excitation:
5, 10, 12, and 24 Vdc @ 25 mA, firmware selectable
Setpoint Adjustment:
-9999 to +9999 counts
Control Action:
PID or ON-OFF
Proportional Band (P): 1.0 to 400.0° (0.0 to 400.0° in cooling)
Times:
0 to 9999 sec Integral (I); 0 to 9999 sec Derivitive (D)
Cycle Time:
0.1 to 99.9 sec (heat or cool)
Hysteresis Width:
0.1 to 99.9°
Manual Reset Value:
-19.9 to 19.9°
Heat-Cool Control:
PID (with auto-tuning)
Dead Band:
Programmable from setpoint low limit to setpoint high limit
Control Output:
One, field selectable as relay or SSR drive
SPST Relay:
Single pole, single throw normally open contact,
250 Vac or 30 Vdc at 5 A (resistive load)
SSR Drive:
Voltage pulse, 12 Vdc ±10%, 50 mA
Aux. (Alarm) Output:
One, factory set as either SPST relay or SSR drive,
Selectable Deviation or Absolute control mode,
0.1 to 99.9° adjustable hystersis
Display:
4 digit 7 segment dual LED display
Height: 0.3785” (upper), 0.2720” (lower)
LED Indication:
Relay ON, Tune, Soak Time
Operating Temp.:
0 to 50°C (32 to 122°F), <95% RH (non-condensing)
Line Voltage:
85-270V AC/DC, 50-60 Hz, 6VA max. at 230V AC
Dimensions:
52x52x100 mm, 46x46 mm panel cutout (1/16 DIN)
6a
Fuji Temperature and Process Controllers
• PID Plus Self Tuning and Fuzzy Control
• Large LED Display
L
CONTROLLERS
• NEMA-4X/IP66 Waterproof Faceplate
• Up to 16 Ramp/Soak Segments in Two 8Segment Patterns
PXR3
• Heating/Cooling Control
• Timer Function
• Dual Control Output Option
• Digital Input Option
• Analog Retransmission Option
• Programmable Alarms Option
• Heater Break Alarm Option
• RS485 (Modbus™ Protocol) Option
• Free Windows®- Based Software
• Manufactured in an ISO 9001 Facility
• 3-Year Warranty
L PXR5
L PXR9
L PXR4
SPECIFICATIONS
Input
Input signal:
Input filter:
Input sampling cycle:
Display
Indication accuracy
(at 23°C):
Control Function
Control action:
Control Outputs
Relay contact:
SSR:
4 to 20 mA DC:
Alarm (option)
Alarm type:
Alarm ON-delay:
Process alarm output:
Heater burnout option
(not available on PXR3):
Heater burnout
alarm output:
7
TC: J, K, R, B, S, T, E, N, PL2. RTD: Pt100.
Voltage, current. For 1 to 5V/4 to 20 mA DC,
0 to 5V/0 to 20 mA DC
0 to 900.0 sec set in 0.5 sec steps
0.5 sec
TC: ±0.5% FS ± 1 digit ±1°C.
TC R (0 to 500°C): ±1% FS ± 1 digit ±1°C.
TC B (0 to 400°C): ±5% FS ± 1 digit ±1°C.
RTD, Voltage, Current: ±0.5% FS ± 1 digit
On/Off; PID control (with auto-tuning, selftuning); Fuzzy Control (with auto-tuning)
PXR3 & Output 2: SPST contact, 220 VAC/30 VDC,
3A (resistive load). PXR4, 5, 9: SPDT, 220
VAC/30 VDC, 3A (resistive load)
PXR3: 12 to 16 VDC
PXR4, 5, 9: ON–17 to 25 VDC;
OFF–0.5 VDC or less.
Max. current: 20mA or less
PXR3: Allowable load resistance 100 to 500Ω.
PXR4, 5, 9: 600Ω or less
Absolute alarm, deviation alarm, zone alarm with
upper and lower limits for each; hold function
available; alarm latch function provided
0 to 9999 sec in 1 sec steps
Relay contact: SPST, 220 VAC/30 VDC, 1A (resistive load); Max. 2 points (PXR3), max. 3 points
(PXR4, 5, 9)
Alarm setting range: 1 to 50A. Available only
when control output is relay or SSR drive
Relay contact: SPST, 220 VAC/30 VDC,
1A (resistive load); 1 output point
Remote Setpoint (option)
Input signal:
1 to 5 VDC, 1 point
Accuracy:
±0.5% ±1 digit
Input sampling cycle: 0.5 sec
Input impedance:
≥1MΩ
Digital Input (option)
Points:
1 or 2; contact closure. 5 VDC, approx. 2mA
Function (select one): Set value (SV, SV1 to 3) changeover, start/stop
control action, start/reset ramp/soak action,
start/stop auto-tuning, cancel alarm latch, start
incorporated timer
Retransmission Output (option)
Output signal:
4-20 mA DC
Load resistance:
500 ohms or less
Output accuracy:
±0.3% FS
Output selection:
PV, SV, MV, DV (SV-PV)
Timer Function (option)
Start:
By digital input option
Setting:
0 to 9999 sec set in 1 sec steps
Action:
Event ON-delay or OFF-delay
Signal output:
Alarm output relays used; 2 points are
available
Communication Function (option)
Physical specifications: EIA RS485
Protocol:
Modbus (RTU). Free Windows®-based
software, PXR-LITE included
Connection aspect:
Multi-drop up to 31 controllers
Communication
Total extension 500m or less
distance:
Operating Conditions and Structure
Operating
14 to 122°F (-10 to 50°C)
temperature:
Mounting method:
Panel flush mounting. PXR3 can be DIN-rail
mounted using the optional adapter
External terminal:
Screw terminal
Fuji Temperature and Process Controllers
SPECIFICATIONS, CONTINUED
Power supply voltage:
Power consumption:
Reference junction
±1°C at 23°C
compensation accuracy:
Dimensions (HxWxD):
PXR3: 1/32 DIN (24 x 48 x 97mm).
PXR4: 1/16 DIN (48 x 48 x 78.8 mm).
PXR5: 1/8 DIN (96 x 48 x 78 mm).
PXR9: 1/4 DIN (96 x 96 x 79.5 mm)
PXR3 ORDERING INFORMATION
To order–Insert Number Code for Each Letter to Select Catalog Number.
Order Example: PXR3-T-A-Y1-4-V-0A1
PXR4, 5, 9 ORDERING INFORMATION
To order–Insert Number Code for Each Letter to Select Catalog Number.
Order Example: PXR4-T-A-Y1-4-V-0A1
A - B - C - D - E - F - G
A - B - C - D - E - F - G
A
A
Front Panel Size
PXR3
1/32 DIN (24x48mm)
B
Input Signal
T
Thermocouple (°C)
R
Thermocouple (°F)
N
RTD, Pt100 ohm, 3-wire type (°C)
S
RTD, Pt100 ohm, 3-wire type (°F)
B
4-20mA DC, 1-5V DC
A
0-20mA DC, 0-5V DC
C
Control Output 1
A
Relay contact output
C
SSR or SSC drive output
E
4-20mA DC output
D
Control Output 2
Y1
None
A1
Relay contact output
C1
SSR or SSC drive output
E1
4-20mA DC output
E
Alarm Options
4
None
5
High/low alarm 1 point
G
High/low alarm 2 points1
F
Power Supply
V
Standard (100-240 VAC, 50/60Hz)
B
24V AC/DC (50/60Hz)
G
Additional Functions
0A1
None
MA1
RS485 communication (Modbus)
QA1
Retransmission + DI 1 point
RA1
Retransmission (4-20mA DC)
TA1
Digital Input (DI) x 2
VA1
RS485 communications (Modbus) + DI 1 point
1
High/low alarm 2 points not available when control output 2 is selected
B
C
D
E
F
G
ORDERING INFORMATION – ACCESSORIES
CTL-6-S
CTL-12
RSFC24
PXR3 Rail Adapter
PXR4 Terminal Cover
Current transformer for 1-30A
Current transformer for 20-50A
RS485 to RS232 signal converter
Mounting adapter for DIN rail installation for PXR3
Terminal block protective cover for PXR4
CONTROLLERS
100 (-15%) to 240V (+10%) AC, 50/60Hz; 24V
(±10%) AC/DC
PXR3: 6VA (100 V), 8VA (220V, 24V).
PXR4: 8VA (100V), 10VA (220V), 12VA (24V).
PXR5, 9: 10VA (100V), 12VA (220V, 24V)
Front Panel Size
PXR4
1/16 DIN (48x48mm)
PXR5
1/8 DIN (48x96mm)
PXR9
1/4 DIN (96x96mm)
Input Signal
T
Thermocouple (°C)
R
Thermocouple (°F)
N
RTD, Pt100 ohm, 3-wire type (°C)
S
RTD, Pt100 ohm, 3-wire type (°F)
B
4-20mA DC, 1-5V DC
A
0-20mA DC, 0-5V DC
Control Output 1
A
Relay contact output
C
SSR or SSC drive output
E
4-20mA DC output1
Control Output 2
Y1
None
A1
Relay contact output
C1
SSR or SSC drive output
E1
4-20mA DC output1
R1
Retransmission (4-20mA DC)
Alarm Options
4
None
6
Heater break alarm1,2
G
High/low alarm 2 points
H
High/low alarm 2 points + heater break alarm1,2
M
Alarm 3 points
D
Remote setpoint3
P
Remote setpoint + alarm 2 points3
Power Supply
V
Standard (100-240V AC, 50/60Hz)
B
24V AC/DC (50/60Hz)
Additional Functions
0A1
None
MA1
RS485 communication (Modbus)
SA1
Digital Input (DI) x 1
TA1
Digital Input (DI) x 21
VA1
RS485 communications (Modbus)+ DI1,3
1
Heater break option not available with 4-20mA output, or with 2 digital inputs, or
with RS485 +1 digital input.
2
Current transformer needed with heater break option.
3
Remote setpoint option not available with RS485 +1 digital input.
8
Newport Humidity & Temperature Controllers
•
•
•
•
•
•
•
•
•
•
•
Dual Loop Control
High Accuracy ±0.5°C and ±2% RH
4 Popular DIN Sizes
2 Control or Alarm Outputs (optional)
Choice of Relays, SSR, DC Pulse,
Analog Voltage and Current
Full Autotune PID Control
Ethernet or RS-232/RS-485 (optional)
User-friendly, Simple to Configure
Programmable Ramp and Soak for
Humidity and/or Temperature
RH / Temperature Probe included
NEMA 4, IP65 Front Bezel
The NEWPORT® iTH Series monitor and
control both temperature and relative
humidity. The meters accurately display
humidity, temperature, or dew point.
They also provide dual loop control for both
humidity and temperature and are easily
programmed for any control or alarming
requirement from simple on-off to full
autotune PID control.
The LED displays can be programmed to change
color between Green, Amber, and Red at any set
point or alarm point.
The iTH family is available in four true DIN sizes
with NEMA 4, IP65 splash resistant bezels: the ultra
compact 1/32 DIN, the popular midsize 1/16 DIN
square bezel with dual display, the 1/8 DIN vertical,
and the 1/8 DIN horizontal with the big bright
21mm digits.
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: NE/iTH - i8DH - 00 - 5 - C24
A – B – C – D – E – F
A
SPECIFICATIONS
Sensor Specifications
Relative Humidity Accuracy/Range:
±2% for 10 to 90% RH
3% for 0 to 10% RH and 90 to 100% RH
Non-Linearity:
±3%;
Hysteresis:
1% RH
Temperature Accuracy/Range*:
±0.5°C (±1°F) for 0 to 80°C (32 to 176°F)
±1°C (±2°F) for -40 to 0°C and 80 to 124°C
(-40 to 32°F and 176 to 254°F)
*Note: extended temperature range is for Probe only, the iTH’s
operating temperature is 0-50°C.
Resolution:
0.03%,12 bit for RH; 0.01°C
14 bit for Temperature
Response Time: 4 sec for RH; 5 sec for Temp
(63% slowly moving air)
General
A/D Conversion:
Reading Rate:
Digital Filter:
Display:
12 bit RH and 14 bit Temp.
2 samples per second max.
Programmable
4-digit, 9-segment LED
• 10.2 mm (0.40"): i32, i16D, i8DV
• 10.2 mm (0.40”) & 21 mm (0.83”): i8DH
Red, green and amber programmable colors for process variable,
set point and temp units
Operating
0 to 50°C (32 to 122°F),
Temperature:
90% RH non-condensing
8a
B
C
D
E
F
Model #
NE/iTH-i8DH
NE/iTH-i8DV
NE/iTH-i16D
NE/iTH-i32
Outputs (2 digits)
0 0
2 2
2 3
2 4
3 3
4 2
4 3
4 4
5 2
Description
Temperature and RH Input 1/8 DIN Dual Display Horizontal
Temperature and RH Input 1/8 DIN Dual Display Vertical
Temperature and RH Input 1/16 DIN Dual Display
Temperature and RH Input 1/32 DIN Single Display
Monitor version, no control outputs.
Two solid state relays (SSR's): 0.5 A @ 120/240 Vac continuous
SSR and relay: Form “C” SPDT 3A @ 120Vac, 3A @ 240Vac
SSR and pulsed 10 Vdc @ 20 mA (for use with external SSR)
2 Relays: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac
Pulsed 10 Vdc @ 20 mA (for use with external SSR) and SSR
Pulsed 10 Vdc @ 20 mA (for use with external SSR) and relay
Two pulsed 10 Vdc @ 20 mA (for use with external SSR)
Analog Output selectable as either control or retransmission of
process value; 0 to 10 Vdc or 0-20 mA @ 500 ohm max. & SSR
5 3
Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm max & Relay
5 4
Analog Out 0 to 10Vdc or 0-20mA @ 500 ohm max & Pulse 10Vdc
RH/Temperature Probe (must select one)
2
2” (51mm) Probe for iTH with 3ft (0.9m) cable
5
5” (137mm) Probe for iTH with 20ft (6.1m) cable
Power Supply
*
Standard power input: 90-240 Vac ±10%, 50-400 Hz,
110-375 Vdc, equivalent voltage (*no entry required)
DC
Low Voltage Power Option: 12 - 36 Vdc; 24 Vac ±10%
Network Options
EI
Ethernet with Embedded Web Server
C24
Isolated RS-232 and RS-485/422. (MODBUS & ASCII)
C4EI
Ethernet with Embedded Web Server + Isolated RS-485/422
hub for up to 31 devices
Factory Setup
FS
Factory Setup and Configuration (requires Network Option)
*1 -C4EI or -EI option is not available on the 1/32 DIN. Consult Sales for other Ethernet devices that can connect to
an iTH-i32xx-x-C24 .
West Process Controller
KEP Batch Controller
CONTROLLERS
• Single or Two Loop
• Graphical & Text LCD Display
• USB, RS485, Ethernet
• Profiling & Datalogging Options
• 1/4 DIN Size
• 4 Plug-in Module Slots
• UL, CE
• Display Rate, Batch Size
and Number of Batches
or Grand Total
• 5 Digit Scaling Factor
• Pulse Input
• 2 Relay Outputs
• Analog Output or
Serial/Modbus Options
• NEMA 4X / IP65
Front Panel
Pro EC44
MB2
Simplifying user operation with an intuitive HMI, fast access front USB port
and easy-to-use configuration and simulation software, Blue Control©.
SPECIFICATIONS
Input 1 & 2: T/C: J, K, T, E, R, S, D, B, C, L, N, PtRh
RTD: 3-wire Pt100, Ni120
DC: 0-50mV, 10-50mV, 0-5V, 0-10V, 1-5V, 2-10V, 0-20mA, 4-20mA
Aux. Input:
0-5V, 0-10V, 1-5V, 2-10V, 0-20mA, 4-20mA
Loops:
1 or 2 control loops
Control:
ON/OFF, PID heat only & Heat/Cool, Valve Motor Drive, Ratio, Cascade
Profiler:
255 segment profiler shared in 64 programs
PID:
5 PID sets manual or automatic gain scheduling
Alarms:
7 can be set as high, low, deviation, band, control loop, rate of
change. Also alarms for sensor break, recorder memory, power
Datalogging: 1sec - 30min interval, non-volatile memory, real time clock
USB:
Host for configuration (read/write) and logged data (read)
Modbus:
Ethernet Modbus TCP; RS485 Modbus RTU (Master/Slave)
I/O:
Up to 2 analog inputs, 9 digital inputs, remote setpoint input;
9 outputs (relay, SSR drive, triac, linear DC, excitation)
Display:
160x80 graphic LCD with red/green backlight, 66x37mm
ORDERING INFORMATION
The Mini-Batcher is a 6 digit totalizer and 4.5 digit ratemeter with two relay
outputs. One output is dedicated to the batch amount (Preset A), the other can
be activated for Prewarn or Batch/Grand Total. The unit can count up to the
preset (reset to 0) or down from the preset (set to preset). Start, Stop and Reset
functions can be activated from the front panel or remote inputs.
Up to 247 units can communicate to a host computer using Modbus RTU
protocol. Alternately, an analog output (assignable for Rate or Batch Amount)
can be ordered for data logging.
SPECIFICATIONS
Display:
Input:
Ratemeter Display:
Accuracy:
Sampling Rate:
Scaling Factor:
Presets:
Front Panel Lockout:
To Order- Insert Code for Each Letter to Select Catalog Number.
Example: EC44-0-C-P-0-2-1-1-8-1-T-1-0-1
Relays:
EC44-0- A – B – C – D – E – F – G – H – I – J – K –1
Relay B On Time:
Power Consumption:
Output Power:
A
B
C
D
E
F
G
Type
C
Controller
U
Controller with USB
D
Controller/Recorder (Datalogger)
R
Controller/Recorder w/USB
Profiler
O
None
P
Profiler
Power Supply
O
100-240V AC
2
24-48V AC/DC
H, I Plug-in Module Slot 2 & 3
Control Loops
O
None
1
One
1
Relay Output SPDT
A
One + Auxiliary
2
DC SSR Drive
2
Two
Y
Dual DC SSR Drive Output
Base Option 1
8
Triac Output
1
Relay Output SPST
9
Dual relay Output SPST
2
Relay + Linear DC Out
T
24VDC Transmitter Supply
Base Option 2
J Plug-in Slot A
0
None
O
None
1
Relay Output SPST
1
RS485 Modbus RTU
2
Relay + Linear DC Out
3
1 Digital
Plug-in Module Slot 1
H, I Plug-in
Module
SlotInput
2&3
Auxiliary Input
O
None
O 4
None
Ethernet
1
Relay Output SPDT
1 5
Relay
OutputModbus
SPDT TCP
K 2Option CDC SSR Drive
2
DC SSR Drive
None
L
Linear DC Output
Y 0
Dual
DC SSR Drive Output
1
8 Digital Inputs
8
Triac Output
6 digit, 0.55" high LED
Pulse, 50VDC max, 10kΩ resistance
Units per second, minute or hour
0.01% FS (±1 digit)
2 to 24 seconds
0.0001 to 99999 (converts input pulses to
engineering units)
Two, 5 digits each
Complete locked out (except Start/Stop) or the presets
can remain accessible
Two N.O. 5A, 120/240VAC or 28VDC. (N.C. contacts and
NPN transistor output available with solder jumpers)
0.01 to 99.99 sec. or latched (0.00 setting)
6.5VA AC or 250mA DC max.
+12VDC @ 50mA, unregulated -10 + 50%
(AC powered units only)
0-54°C (32-130°F), <90% RH, non-condensing
EEPROM stores data for 10 years if power is lost
4.44"W x 2.63"H x 4.25"D (113 x 67 x 108mm)
3.622" x 1.772" (92 x 45mm)
Operating Temperature:
Memory:
Dimensions:
Cutout:
ORDERING INFORMATION
To Order—Insert Code for Each Letter to Select Catalog Number.
Order Example: KE/MB2C34
KE/MB2
A
A
110 VAC ±15% or 12-15 VDC
220 VAC ±15% or 12-15 VDC
24 VAC ±15% or 12-15 VDC
Count Inputs
3
3M
C
C
Operating Voltage
A
B
C
B
B
4-30 VDC or 0-1VDC pulse, 10kHz max.
30mV mag. pickup, 5kHz max.
Options
1
2
3
4
A
RS232 Comm., KEP protocol
RS422 Comm., KEP protocol
RS232, Modbus RTU
RS422/RS485, Modbus RTU
Analog Output (4-20/0-20 mA)
9
Partlow DIN Controllers
L
• Dual 4 digit display
• User selectable input type
• Up to three outputs
• 3 year warranty
1801+
SPECIFICATIONS
Input:
SPECIFICATIONS
Inputs:
Accuracy:
Input Sample Rate:
Impedance:
Outputs:
Sensor Break Detect:
Communications:
Operating Temperature:
Supply Voltage:
Protection:
T/Cs: J, K, C, R, S, T, B, L, N, Pt 20% Rh vs. Pt40% Rh
RTD: 3-wire Pt100, <50Ω per lead (balanced)
DC (scalable –1999 to +9999): 0–5, 1–5, 0–10 or 2–10VDC;
0–50mV, 10–50mV; 0–20mA, 4–20mA
±0.1% of input range ±1 digit (T/C CJC better than 1°C)
4 per second; 14 bit resolution
>10MΩ for T/C and mV ranges, 47kΩ for V ranges,
5Ω for mA ranges
Relay:
SPDT, 240VAC@2A resistive
SSR Driver:
>10VDC nominal into 500Ω min.
DC Linear:
0–20, 4–20mA into 500Ω max.;
0–10, 1–5, 2–10, 0–5V into 500Ω min.
Triac:
0.01-1A AC, 20-280Vrms, 47–63Hz
<2 seconds
2-wire, RS-485, Modbus or ASCII
32–131°F (0–55°C), <95% RH non-condensing
100–240V, 50/60Hz or 20–48VAC / 22–65 VDC
IP66, NEMA 4X (front panel)
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: PA/1160114300
A
A
B
C
D
E
F
Basic Unit
PA/1160
1160+ PID Controller (1/16 DIN)
PA/1400
1400+ PID Controller (1/4 DIN)
PA/1800
1800+ PID Controller (1/8 DIN)
B–C–D
Option Option Option
Slot 1
Slot 2
Slot 3
0
0
0
None
1
1
1
Relay output
2
2
2
DC drive output for SSR
3
3
3
Linear DC output
4
4
24V Transmitter power supply*
8
8
8
Triac output*
E
Option Slot A
0
None
1
RS-485 serial comm
2
Green upper display
3
RS-485 & green upper display
4
Green lower display
5
RS-485 & green lower display
6
Green upper & lower display
7
RS-485 & two green displays
8
Digital input
9
Digital input & green upper display
A
Digital input & green lower display
B
Digital input & two green displays
C
Basic Remote Setpoint Input (RSP)
D
Basic RSP & green upper display
E
Basic RSP & green upper display
F
Basic RSP & two green displays
F
Power Supply
00
100-240VAC
02
24-48V AC/DC
*max. one transmitter supply, two triac outputs per unit
CONTROLLERS
1160+
• 1/16, 1/8 & 1/4 DIN Sizes
L
• Dual setpoints with optional
remote selection
• Plug-in output modules
• Customizable operator menus
• Process and loop alarms
• Full PID or ON/OFF control
• Heat/Cool operation
(with dual outputs)
• Selectable pre-tune,
self-tune, manual tune
Partlow Limit Controllers
Output:
Output Function:
Control:
Operating Temperature:
Protection:
Thermocouple J, K, C, R, S, T, B, L, N
3 wire 100 ohm Pt RTD
DC linear V (scalable –1999 to +9999)
DC linear mA (0–20 or 4–20)
DC linear mV (0–50 or 10–50)
Relay SPDT 2A, 240VAC resisitive
SSR drive >10VDC into 500Ω min
Triac 0.01–1A, 20–280VAC
Limit, alarm (process, deviation/band)
High/low limit
0–55°C, 20–95% RH
IP66, NEMA 4X front; IP20 behind panel
ORDERING INFORMATION
To Order–Insert Number Code for Each Letter to Select Catalog Number.
Order Example: PA/1161 010602
A
B
C
D
E
F
A Basic Unit
PA/1161
1/16 DIN Limit Controller
PA/1401 1/4 DIN Limit Controller
PA/1801 1/8 DIN Limit Controller
B Option Slot 1
0
Relay Output
C Option Slot 2
0
None
1
Relay Output
2
DC drive output for SSR
3
Linear DC output
4
24V Transmitter power supply*
8
Triac output
D Option Slot 3
0
None
1
Relay Output
2
DC drive output for SSR
3
Linear DC output
4
24V Transmitter power supply*
8
Triac output
E Option Slot A
0
None
1
RS-485 serial comm
2
Green upper display
3
RS-485 & green upper display
4
Green lower display
5
RS-485 & green lower display
6
Green upper & lower display
7
RS-485 & two green display
8
Digital input
9
Digital input & green upper display
A
Digital input & green lower display
B
Digital input & two green displays
F Power Supply
00
100–240VAC
02
24–48V AC/DC
*One transmitter supply per unit
10
Newport Digital Indicator Controllers
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: Q2001-CVR6
A
A
B
C
D
E
F
B
C
D – E
F
Display Resolution and Case Style
Q2
±1999 Counts (31⁄2-digits)
Q3
±1999 with “Infinity™ Family Bezel and Adapter”
Q9
±9999 Counts (4-digits)
Q8
±9999 with “Infinity™ Family Bezel and Adapter”
Display Type and Meter Power
0
LED, 120 VAC (49/440 Hz) (BQ20 or BQ90)
2
LED, 240 VAC (49/440 Hz) (BQ22 or BQ92)
4
LED, 9–32 VDC (isolated) (BQ24 or BQ94)
6
LED, 5 VDC** (BQ26 or BQ96)
8
LED, 24 VAC (BQ28 or BQ98)
A
LED, 26-–56 VDC (isolated) (BQ2A or BQ9A)
**Not available with AC AVG or True RMS inputs
Analog Output Adders
Max one analog output in addition to recorder output
0
±1 or ±2 V recorder output, non-isolated
1
0–5 VDC, non-isolated (BA01)
2
0–10 VDC, non-isolated (BA01)
3
0–1 mA, source or sink, non-isolated (BA01)
4
4–20 mA, source or sink, non-isolated (BA01)
6
4–20 mA, isolated (BA03)
Control Output Adders
0
None
1
Dual-Setpoint 10A Relay (BDT1)
4
BCD (BDD2)
5
Single-Setpoint 10A Relay (BDS1)
Signal Conditioning Input Adders
❑
Select from Input Table
Green LEDs for Display
G
Green
0
None
INPUT TABLE
Code
Q2000/Q3000
Q8000/Q9000
DC Voltage Input
AVR1
±199.9 mV
±99.99 mV
AVR2
±1.999V
±999.9 mV
AVR3
±19.99V
±9.999V
AVR4
±199.9V
±99.99V
DC Current Input
BCR1
±19.99 µA
±9.999 µA
BCR2
±199.9 µA
±99.99 µA
BCR3
±1.999 mA
±999.9 µA
BCR4
±19.99 mA
±9.999 mA
BCR5
±199.9 mA
±99.99 mA
BCR6
±1.999A
±999.9 mA
AC AVG Voltage Input
CVR2
199.9 mV
99.99 mV
CVR3
1.999V
999.9 mV
CVR4
19.99V
9.999V
CVR5
199.9V
99.99V
CVR6
650V
650.0V
AC AVG Current Input
DCR1
19.99 µA
9.999 µA
DCR2
199.9 µA
99.99 µA
DCR3
1.999 mA
999.9 µA
DCR4
19.99 mA
9.999 mA
DCR5
199.9 mA
99.99 mA
DCR6
1.999A
999.9 mA
DCR7-(*) (1) 5A = 1000, (2) 5A = 1500, (3) 5A = 2000,
(4) 5A = 300, (5) 5A = 500
10a
Quanta® Standard Features
• Field Selectable Input Ranges
• Recorder Analog Output
• Front-Panel Accessible
Span Adjustment
• Bright, 0.56"
(14.2 mm) LED Display
• Display Hold and Test
• Screw-Terminal Barrier Strip
• Optional Relay Outputs
• 1⁄8 DIN Case
Options
• Analog Output for
User-Selected Span
• Single-Setpoint 10A
SPDT Relay
• Dual-Setpoint with Two
10A SPDT Relays
• Parallel BCD Output,
Isolated
Quanta
▲
INPUT TABLE (CONT’D)
Code
Q2000/Q3000
Q8000/Q9000
True-RMS Voltage Input
FVR2
199.9 mV
99.99 mV
FVR3
1.999V
999.9 mV
FVR4
19.99V
9.999V
FVR5
199.9V
99.99V
FVR6
650V
650.0V
True-RMS Current Input
GCR1
19.99 µA
9.999 µA
GCR2
199.9 µA
99.99 µA
GCR3
1.999 mA
999.9 µA
GCR4
19.99 mA
9.999 mA
GCR5
199.9 mA
99.99 mA
GCR6
1.999A
999.9 mA
GCR7-(*) (1) 5A = 1000, (2) 5A = 1500, (3) 5A = 2000,
(4) 5A = 300, (5) 5A = 500
Frequency/Rate Input (100 mV Hystersis):
H
1000 Hz = 1000
1000 Hz = 0–9999
Type J Thermocouple Input
JDC1
-40 to +760°C
-40.0 to +760.0°C
JDF1
-40 to +1400°F
-40.0 to +999.9°F
Type K Thermocouple Input
KDC1
-40 to +1260°C
-40.0 to +999.9°C
KDF1
-40 to +1999°F
-40.0 to +999.9°F
Type T Thermocouple Input
TDC1
-184 to +371°C
-184.0 to +371.0°C
TDF1
-300 to +700°F
-300.0 to +700.0°F
RTD (Pt 100) Input
Alpha = 0.00385
MDC1
-200 to +830°C
-200.0 to +830.0°C
MDF1
-328 to +1526°F
-328.0 to +999.9°F
RTD Input, High Resolution
Alpha = 0.00385
RDC1
-199.9 to +199.9°C Not available with Q8/Q9
RDF1
-199.9 to +199.9°F Not available with Q8/Q9
3-Wire Ratio Potentiometer Input
NPR1
1000 = 1 kOhm
9999 = 1 kOhm
NPR2
1000 = 5 kOhm
9999 = 5 kOhm
2- or 4-Wire Resistance Input
OOR1
19.99 Ohm
Not available with Q8/Q9
OOR2
199.9 Ohm
Not available with Q8/Q9
OOR3
1999 Ohm
Not available with Q8/Q9
OOR4
19.99 kOhm
Not available with Q8/Q9
Process Signal Input
P
4–20 mA = 0–100.0 4–20 mA = 0–99.99
Process Signal Input
Excitation set to 15 VDC
E
4–20 mA = 0–100.0 4–20 mA = 0–99.99
Strain-Gage/Microvolt Input
Excitation set to 10 VDC (30 mA max)
S
±100 mV = ±100.0
±100 mV = ±99.99
Download