Weschler Premo BarGraph Meter/Controller The Premo Bargraph Controller is a full featured, high resolution meter for display and control of process parameters. A wide range of input modules measure electrical signals, sensors and transducers. Analog and digital outputs easily connect to remote indicators or a plant SCADA system. Up to 6 setpoints can be programmed to operate within the span of the selected input module. PID control is available from the first two setpoints. PC Specifications on next page. ORDERING INFORMATION CONTINUED D ORDERING INFORMATION A B C D A B C D E F G H I Style C 4 1/2" Switchboard D 12" Edgewise Vertical G 6" Edgewise Vertical Bar Color R Red G Green T Tricolor Digital Display Color R Red G Green Input (partial list) DBQ DC, 20/50/100/200mV w/24V Excitation DCQ DC, 2/20/200mA w/24V Exc DGQ DC, 1A DDQ DC, 5A ABQ AC, 200mV/2V/20V, scaled RMS AAQ AC, 200/600V, scaled RMS AGQ AC, 200mV/2V/20V, True RMS AFQ AC, 200/600V, True RMS ACQ AC, 2/20/200mA, scaled RMS ADQ AC, 1 Amp, scaled RMS AEQ AC, 5 Amp, scaled RMS AHQ AC, 2/20/200mA, True RMS AJQ AC, 1A, True RMS AKQ AC, 5A, True RMS PDQ Process 2/5/10/20/200V/2mA/20mA/Custom TMP Thermocouple, J/K/R/S/T/B/N PG PD To Order—Insert Code for Each Letter to Select Catalog Number. Order Example: PCRGDCQ1A5CXXXX PC CONTROLLERS Direct Measurement of: DC Current AC Current DC Voltage AC Voltage Frequency Power Process Loops Thermocouples RTDs Load Cells/ Strain Gauges LVDTs Pressure Speed Pickups/ RPM Resistance/Potentiometers Quadrature Event Counting L L •Datalogging & PID control functions •Cross channel calculations with multi-channel input modules •Front panel & external dimming •Enhanced table calibration for tank level, square law & other non-linear measurements •Optional SD memory card for long term data logging •3 case styles L •101 segment red, green or tricolor bar •6 digit alpha-numeric readout •Rugged steel case, standard switchboard mounting •6 assignable relays with tracking, latching & manual reset functions •Single or dual analog retransmit •ASCII, Modbus Serial & Ethernet communications •Wide variety of input modules NEW J E F G H I J Input continued THP RTD, 100Ω Pt, 2/3/4-wire GHQ Direct Pressure, 30 psi differential/gage GKQ Direct Pressure, 100 psi differential/gage SBQ Pressure 5/10VDC Exc., 2/20 mV/V, 4/6-wire EAP Line Frequency, 50-500VAC FAP Universal Frequency / RPM / Up Down Counter CAP Quadrature Counter REP Resistance, 2/3/4-wire, 200/2k/20kΩ KAP Single Phase Power, 300V/1A from CT KBP Single Phase Power, 300V/5A from CT KCP DC Watts, 200V/50mV from shunt PAD Dual Process Loop, 4-20mA DCD Dual DC, 2mA DBD Dual DC, 2V TAD Dual Thermocouple, J/K/R/T FAD Dual Frequency FBD Dual Counter Power 1 85-265VAC/95-370VDC 2 15-48VAC/10-72VDC Retransmit (analog output) A Isolated 4-20mA or 0-20mA, scalable V Isolated 0-10VDC, scalable D Isolated Dual 0-10VDC, scalable X None Communications 2 Isolated ASCII Code RS-232 4 Isolated ASCII Code RS-485 5 Isolated ModBus Protocol RS-232 6 Isolated ModBus Protocol RS-485 8 Ethernet ACSII TCP/IP 9 Ethernet ModBus TCP/IP Relays (partial list) C Two 10A Form C D Two 10A Form C & Two 5A Form A H Six Form A X None Memory A 1M with Real time clock X Standard Options (2 digits) D Continuous external dimming W Spray tight front X None 4 Weschler Premo BarGraph Meter /Controller Yokogawa Temperature Controllers Continued from previous page • On/Off, PID, Heat/Cool & Limit Control • Dynamic auto tune & "SUPER" overshoot suppression • Compact 1/16 DIN package • Large LED display • IP65 splash & dust-proof front panel • Optional analog retransmit of measured value UT130 • Timer function (UT150) • Optional heater burnout alarm & two alarm output relays • Optional 24V AC/DC power supply • Optional RS-485 MODBUS communication SPECIFICATIONS CONTROLLERS Digital Display Range: -199999 to 999999 Decimal Point: Five positions, front panel selectable Update Rate: 3 to 10 times per second Display Dimming: 8 level from front panel; continuous external option A/D Converter: Bipolar 17 bit (optional 23 bit) Counter Functions: Two built-in Up/Down counters Data Logging: Logging with date/time (Memory option A) Trigger: Time interval, setpoint, manual Data storage: Non-volatile EEPROM Linearization: 4 selectable 32 point tables, cascadeable Math Functions: Sum, difference, ratio or the product of two inputs Offset Functions: Tare, compensation and calibration Peak and Valley: Min/Max storage with front panel recall Digital Comm: RS-232, RS-485, Ethernet Setpoint Functions: Hysteresis, on/off delays, one shot, pulse and repeat timers, latching, dual PID, setpoint tracking, logging trigger Signal Processing: Timer: Totalalizer: Analog Output: Resolution: Compliance: Real Time Clock: Power: (DC to 400Hz) Operating Temperature: Software: Averaging, smart filter, rounding, square root Time-up, time-down, or real-time clock modes Two, for Total and Batch Total Isolated 16-bit, accuracy 0.02% FS 0.4µA on current, 250µV on voltage 500Ω max. for current, 500Ω min. for voltage Optional, 15 yr Lithium battery backup 85-265VAC / 95-370VDC @ 5W max 15-48VAC / 10-72 VDC @ 5W max 0-50°C (32-122°F), <95% (non-condensing) at 40°C PC-based configuration utility Style C Bar: Digits: Case: Size: Mounting: Style G Bar: Digits: Case: Size: Mounting: Style D Bar: Digits: Case: Size: Mounting: 5 7.25" length, 235° arc, ±60° viewing angle 0.43" (10.9mm) height Steel housing, molded front & rear bezel 4.43" square bezel, 4.75" behind panel Fits standard ANSI 4" switchboard cutout 10" length, ±60° viewing angle 0.31" (7.9mm) height Steel housing, molded rear bezel 1.7" x 6.04", 7" behind panel Fits standard ANSI 6" switchboard cutout 4" length, ±60° viewing angle 0.43" (10.9mm) height Steel housing, metal front, molded rear bezel 3.15" x 12.9", 7.8" behind panel Fits Bailey draft gauge cutout L SPECIFICATIONS Input: RTD: T/C (all models): T/C (UT15O models): DC In (UT15O models): Basic Accuracy: T/C: RTD: DC: Setpoints: Timer (UT15O models): Retransmit: Contact Input: Contact Output: Alarm: Display: Power: Approvals: Temperature: Dimensions: 3-wire Pt100 J, K, T, E, L, U R, S, B, N, platinel 0-100mV, 0-5V, 1-5V, 0-10V ±2°C ±1d ±1°C ±1d ±0.3% ±1d 1 on UT130, 2 on UT150 Up to 100 hours 4-20mA 2 points for SP select, run/stop or timer 2 for alarm, heater disconnect or timer 25 types UT130: single 0.7" 3-digit LED UT150: dual (red/green) 4-digit LED 100-240VAC, 8VA UL, CSA, CE 0-50°C operating 48x48x100mm ORDERING INFORMATION To Order—Insert Code for Each Letter to Select Catalog Number Example: UT130-RN/AL/RS A B C A Model UT130 Temperature Controller UT150 Temperature & Voltage Controller UT150L Limit Controller B Control /RN Relay output /VN Pulse output3 /AN 4-20mA output (UT150 only)3 /RR Heat/cool relay outputs3 /VV Heat/cool pulse outputs3 /AA Heat/cool 4-20mA outputs (UT150 only)3 C Options /AL Alarm output (2 points) /V24 24V AC/DC power supply 3 /HBA Heater disconnect alarm 2 3 /RET Analog retransmit (UT150 only) /RS RS-485 Communications /EX Two contact input (UT150 only) 1 1 cannot be ordered with communications when heat/cool control specified 2 cannot be ordered with communcations 3 not available on UT150L NEW Yokogawa Advanced Controllers Universal Input: With built-in Ladder Sequence Control, the UT Advanced controllers can replace a small PLC to: Thermocouple: Type K, J, T, B, S, R, N, E, L, U, W, PL-2, PR20-40, W97Re3, W75Re25 • Monitor and control external machinery RTD: Pt100, JPt100 (3-wire except 3/4• Implement digital input/output logic wire on 55A) functions. DC Voltage: 0.4 to 2V, 1 to 5V, 0 to 2V, 0 to 10V, Sequence control and PID control can be performed simultaneously. -10 to 20mV, 0 to 100mV DC Current: 4 to 20mA, 0 to 20mA The Fuzzy Logic Control functions deliver fine Standard Power Supply: 100-240 V AC control and reduce overshoot or hunting. PV Display: 5 digits, 0.1% of FS accuracy 8 Built-in Control Types • PID control • ON/OFF control (1 point hysteresis) • ON/OFF control (2 point hysteresis) • Two-position, two-level control • Heating/cooling control • Sample PI control • Batch PID control • Feedforward control 8 Built-in Control Modes • Single-loop control • Cascade primary-loop control • Cascade secondary-loop control • Cascade control • Loop control for backup • Loop control with PV switching • Loop control with PV auto-selector • Control with PV-hold To Order—Insert Code for Each Letter to Select Catalog Number. Model Size # of Analog Inputs Std (Max) # of SPs (PIDs) Max # of Control Modes Max # of Control Types Max Relay, Pulse, Current Output # of Analog Outputs Std (Max) # of Digital Inputs Std (Max) # of Alarms Max # of Digital Outputs Std (Max) RS-485 communication (Max) Ethernet communication Split Computation Output Ratio & Square Root Extraction Remote SP Function Heater Break Alarm Function Ladder Sequence (max. steps) Control Scan Period (msec) Bar graph display (Number) 5b UT55A 1/4 DIN 1 (4) 8 8 8 2 (3) 3 (9) 8 3 (18) (2) Std type (500) UP55A— A A Control 0 1 2 B Functions 0 1 UT52A 1/8 DIN 1 (2) 8 8 8 2 (3) 3 (5) 8 3 (5) (1) — Std type (500) (2) ORDERING INFORMATION UM33A— A Standard type Position proportional type Heating/cooling type None Remote (1 additional aux. analog) input, 1 additional DI 2 RS-485 (Max.19.2 kpbs, 2/4-wire) 3 10 additional DOs 4 3 additional aux. analog inputs, 2 DIs & 5 DOs to be deleted C Network Communications 0 None 1 RS-485(Max.38.4 kbps, 2/4-wire) 2 Ethernet (with serial gateway function) D Case Color 10 Light Gray 11 Dark Gray E Options /DR Additional direct input (TC & 3/4-wire RTD), current input to Remote (1 additional aux. analog) input, 1 DI to be deleted /HA Heater break alarm /DC Power supply 24 V AC/DC /CT Coating 50/100/200 (2) UM33A C _ D — 00 / E B UP55A UT35A UT32A •Scrolling text •Programmable function keys •RS-485 (Modbus) & Ethernet communications •3 year warranty UT35A UT32A 1/4 DIN 1/8 DIN 1 1 4 4 1 1 5 5 2 2 2 (7) 2 (4) 4 4 3 (8) 3 (5) (1) (1) — — — — — — — Std or Heat/cool (300) (300) UP55A 1/4 DIN 1 (4) 8 5 4 2 (3) 3 (9) 8 8 (18) (2) Std type (500) UP35A 1/4 DIN 1 4 1 4 2 3 (8) 2 3 (8) (1) — — — Std type (300) UM33A 1/8 DIN 1 — — — — 1 2 8 3 (9) (1) — — — 200 200 100/200 200 50/100/200 (1) (1) (2) (1) — See complete data sheet for additional options and ordering information for UT55A, UT52A, UP35A models. B _ C / D A Control 0 Standard type B Functions 00 None 10 1 additional DO (form C relay) + RS-485 comm (Max. 38.4kbps, 2/4-wire) 20 1 additional DO (form C relay) 30 6 additional DOs (form C relay; 1 point & open collector; 5 points) C Case Color 10 Light Gray 11 Dark Gray D Options /LP 24 V DC loop power supply /DC Power supply 24 V AC/DC /CT Coating UT32A— A B _ C — 00 / D A Control 0 Standard type 1 Position proportional type 2 Heating / cooling type B Functions 00 None 10 RS-485 comm (Max.38 kbps, 2/4-wire) 20 2 additional DIs & 2 additional DOs C Case Color 10 Light Gray 11 Dark Gray D Options /LP 24 V DC loop power supply /HA Heater break alarm /DC Power supply 24 V AC / DC /CT Coating UT35A— A B C _ D — 00 / E A Control 0 Standard type 1 Position proportional type 2 Heating / cooling type B Functions 0 None 1 2 additional DIs and 2 additional DOs 2 5 additional DIs and 5 additional DOs C Network Communications 0 None 1 RS-485 (Max.38.4 kbps, 2/4-wire) 2 Ethernet (with serial gateway function) D Case Color 10 Light Gray 11 Dark Gray E Options /LP 24 V DC loop power supply /HA Heater break alarm /DC Power supply 24 V AC / DC /CT Coating CONTROLLERS •8 built-in PID control modes •8 built-in PID control types •Ladder sequence control •Fuzzy logic control •Active color LCD display Digital Indicating Controllers: UT55A, UT52A, UT35A, UT32A Program Controllers: UP55A, UP35A Digital Indicator with Alarms: UM33A Newport Temperature and Process Controllers PLATINUM Series • High accuracy, high performance (24 bit, 20 samples/sec) • Full autotune PID with fuzzy logic adaptive control • Universal input (T/C, RTD, thermistor, process V & mA) • Up to 99 programs with 16 ramps and soaks and chaining • Bright 3-color (red/green/amber) 9 segment LED display • Dual display (Pt16D & Pt32D) • Analog, pulse and relay output options • USB host communications standard • Optional Ethernet & RS232/485 with Modbus • No jumpers to set, totally firmware configurable • NEMA 4, IP65 front (NEMA 1 on 1/8 DIN size) ® SPECIFICATIONS INPUTS Input Types: Current Input: Voltage Input: Thermocouple Input: RTD Input: Thermistor Input: Configuration: Basic Accuracy: Resolution: Input Impedances: Process Voltage: Process Current: Thermocouple: Auxiliary Input: A/D Conversion: Reading Rate: Digital Filter: CMRR: Excitation: Setpoint Adjustment: CONTROL MODES Action: Auto-Tune: Adaptive Tune: Pt8D Pt16D Pt32 Control Modes: Cycle Time: Ramp and Soak: ORDERING INFORMATION Model No. Output 1 Single Display Models Pt*-330 SPDT Relay Pt*-220 0.5 A SSR Pt*-304 SPDT Relay Pt*-305 SPDT Relay Pt*-440 DC Pulse Pt*-224 0.5 A SSR Pt*-225 0.5 A SSR Pt*-144 SPST Relay Pt*-145 SPST Relay Pt*-444 DC Pulse Pt*-445 DC Pulse Dual Display Models Pt**D-330 SPDT Relay Pt**D-220 0.5 A SSR Pt**D-304 SPDT Relay Pt**D-305 SPDT Relay Pt**D-440 DC Pulse Pt**D-224 0.5 A SSR Pt**D-225 0.5 A SSR Pt**D-144 SPST Relay Pt**D-145 SPST Relay Pt**D-444 DC Pulse Pt**D-445 DC Pulse Output 2 Output 3 SPDT Relay 0.5 A SSR DC Pulse Analog DC Pulse 0.5 A SSR 0.5 A SSR DC Pulse DC Pulse DC Pulse DC Pulse — — — — — DC Pulse Analog DC Pulse Analog DC Pulse Analog SPDT Relay 0.5 A SSR DC Pulse Analog DC Pulse 0.5 A SSR 0.5 A SSR DC Pulse DC Pulse DC Pulse DC Pulse — — — — — DC Pulse Analog DC Pulse Analog DC Pulse Analog Segment Times: Options -EIP Ethernet with embedded web server (not available on Pt32) -C24 Isolated RS232/RS485 @ 1200 to 115,200 baud -DC 12-36 Vdc power; 20-36 Vdc for dual display or Ethernet option * Insert 32 for 1/32 DIN size, 16 for 1/16 DIN size, 8 for 1/8 DIN size ** Insert 16 for 1/16 DIN size, 8 for 1/8 DIN size Example: Pt16D-330-C24-DC NEW CONTROL OUTPUTS Analog Output: DC Pulse: SPST Relay: SPDT Relay: SSR: Thermocouple, RTD, Thermistor, DC Voltage, DC Current 4 to 20 mA, 0 to 24 mA scalable -100 to 100 mV, -1 to 1 V, -10 to 10 Vdc scalable K, J, T, E, R, S, B, C, N 100/500/1000Ω Pt, 2-, 3- or 4-wire; 0.00385, 0.00392 (100Ω only), or 0.003916 (100Ω only) curves 2252Ω, 5kΩ, 10kΩ Differential, bipolar 0.03% FS process, 0.3°C RTD, 0.2°C thermistor, 0.4°C J/K/T/E/C/N, 0.5°C R/S/B 0.1° temperature; 10 μV process 10MΩ for ±100 mV, 1MΩ for other voltage ranges 5Ω 10kΩ max 3.5kΩ for 0-10 V, 50kΩ for 0-1 V, 50Ω for Current 24-bit sigma delta 20 samples per second Programmable from 0.05 seconds to 6.4 seconds 120 dB 5, 10, 12, and 24 Vdc @ 25 mA, firmware selectable -9999 to +9999 counts Reverse (heat), direct (cool), or heat/cool Operator initiated from front panel User selectable; fuzzy logic continuous PID tuning optimization ON/OFF or the following time/amplitude proportional control modes; selectable manual or auto PID, proportional, proportional with integral, proportional with derivative 0.1 to 199 seconds Up to 99 saved ramp & soak programs, up to 8 ramp & 8 soak segments with individually selectable events per program 00.00 to 99.59 (HH:MM) or 00.00 to 99.59 (MM:SS) Non-isolated, Proportional 0 to 10 Vdc or 0 to 20 mA; 500Ω max; programmable for control or retransmission; accuracy is 0.1% of full scale Non-isolated; 10 Vdc at 20 mA Single pole, single throw mechanical relay, 250 Vac or 30 Vdc at 3 A (resistive load) Single pole, double throw mechanical relay, 250 Vac or 30 Vdc at 3 A (resistive load) 20 to 265 Vac at 0.05-0.5 A (resistive load); COMMUNICATIONS (USB standard, Serial and Ethernet optional) Connection: USB: Female micro-USB Ethernet: Standard RJ45 Serial: Screw terminals USB: USB 2.0 host or device Ethernet (IEEE 802.3): 10/100 Base-T autoswitching, TCP/IP, ARP, HTTPGET Serial: Software selectable RS232 or RS485; programmable 1200 to 115200 baud Protocols: Newport ASCII, Modbus® ASCII/RTU ISOLATION (1min test) Power to Input/Output: Power to Relays/SSR: Relay to Relay/SSR: SSR to Relay/SSR: RS232/RS485 to I/O: GENERAL Operating Temp.: Line Voltage: Low Voltage Option: 2300 Vac; 1500 Vac (low voltage/power option) 2300 Vac 2300 Vac 2300 Vac 500 Vac 0 to 50°C (32 to 122°F), 90% RH non-condensing 90-240 Vac ±10%, 50-400 Hz, 110-375 Vdc; 5W max. 12-36 Vdc power; 20-36 Vdc for dual display or Ethernet (not CE or UL) Display: 4-digit, 9-segment LED Case depth: 127mm Optional PT-USB-CABLE is a NEMA4 rated panel mount USB connector with 12" (304mm) cable that connects to the controller’s USB port. Includes protective end cap. 5c Extech PID Controller • Dual 4-digit LED displays for process & setpoint values • User-friendly menus and tactile keypad • Fuzzy Logic PID offers intuitive control • Manual mode overrides automatic control • One-touch Auto Tuning for quick setup and precise control • Single stage Ramp and Soak program with Ramp-to-Setpoint Limit • Soft Start feature for smooth process start-up • Accepts thermocouple and RTD inputs • Select input type from display menu – no hardware change • Two ‘Latching’ relays with 8 Alarm modes & advanced Timer modes Inputs Type K Type J Type B Type T Type E Type R, S Type N Type C Pt100 RTD (DIN) Pt100 RTD (JIS) Control/Alarm Relay DC Current Output Accuracy Sampling Time LED Status Control Modes Front Panel Power Supply • • • • • • High Accuracy ±0.5°C, 0.03% Rdg. Extended 5-Year Warranty Universal Inputs Relay, SSR, DC Pulse Outputs Ramp to Setpoint Universal Power Supply, 90–250 VAC or VDC • Dual Output and Dual Alarm • Optional RS-232, RS-485, Isolated Analog Output or Remote Setpoint CONTROLLERS L 48VFL Newport Autotune Process & Temperature Controller ▲ ICN77 SPECIFICATIONS Input Input Types: Thermocouple, RTD, analog voltage, analog current Thermocouples: J, K, T, E, R, S, B, C, N, and J DIN Accuracy: ±0.5°C temp; 0.03% rdg. process ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: ICN77-5-3-2-A2 A – B – C – D – E SPECIFICATIONS A -58 to 2498°F (-50 to 1370°C) -58 to 1832°F (-50 to 1000°C) 32 to 3272°F ( 0 to 1800°C) -454 to 752°F (-270 to 400°C) -58 to 1382°F (-50 to 750°C) 32 to 3182°F ( 0 to 1750°C) -58 to 2372°F (-50 to 1300°C) -58 to 3272°F (-50 to 1800°C) -328 to 1652°F (-200 to 850°C) -328 to 1202°F (-200 to 650°C) 5 Amp @ 110V, SPST (resistive load) 4-20mA (resistive); Impedance < 600 ohms T/C: ±1.8°F (1°C); RTD: ±0.36°F (0.2°C) 4 samples per second Alarm and Control output status Fuzzy Logic enhanced three-term PID with Auto Tune • Proportional Band 0 to 300.0% • Integral time 0 to 3600 seconds • Derivative time 0 to 900 seconds • Hysteresis 0.0 to 200.0 or 0.0 to 2000 • Cycle time 1 to 100 seconds Lexan, Drip/Dust proof, IP63 90 to 264 VAC; 50/60 Hz (< 5VA) B C D E F – F Basic Unit ICN77 1/16 DIN Controller Configuration 5 NEMA-4/IP65 Face with DIN Cutout R5 Square Bezel with 1 3/4" Round Cutout Primary Output 2 SSR (1A @ 120/240 VAC) 3 SPDT Relay (5A @ 120 VAC) 4 Pulsed 0–10 VDC @ 20 mA Max 5 Non-isolated 1–10V or 0–20 mA Second Output 0 None 2 SSR (1A @ 120/240 VAC) 3 SPDT Relay (5A @ 120 VAC) 4 Pulsed 0–10 VDC @ 20 mA Max Options A2 Second Alarm Relay C2 Isolated RS-232 C4 Isolated RS-485 PV Isolated Analog Output RSP Remote Setpoint Optional Power–Include Only if Required DC 10–34 VAC/VDC Power ORDERING INFORMATION—ACCESSORIES ORDERING INFORMATION 48VFL11 48VFL13 96VFL11 96VFL13 1/16 DIN Temperature PID Controller with one relay output 1/16 DIN Temperature PID Controller with 4-20mA output 1/4 DIN Temperature PID Controller with two relay outputs 1/4 DIN Temperature PID Controller with 4-20mA output SPC-116-S TP4 TP6 Splash-Proof Cover for 1/16 DIN Controllers Trim Plate Adapter to Install 1/16 DIN Meter in Existing 1/4 DIN Panel Cutout Trim Plate Adapter to Install 1/16 DIN Meter in Existing 1/8 DIN Panel Cutout 6 NEW ATC Temperature Controller • Dual 4-digit, seven segment LED display • PID & On/Off control • Thermocouple and RTD input • °C / °F selectable • Two setpoints • Field selectable Control Output (Relay or SSR) • Auxiliary Output - factory installed Relay or SSR • 1/16 DIN Case, IP65 Front INPUT RANGES 1° ATC550 SPECIFICATIONS Inputs: Sampling Time: Input Filter (FTC): Temperature Unit Indication Accuracy: Resolution 0.1° Pt100 RTD °C -150 to 850 °F -238 to 1562 Thermocouple J °C -199 to 750 °F -328 to 1382 K °C -199 to 1350 °F -328 to 2462 T °C -199 to 400 °F -328 to 750 R&S °C 0 to 1750 °F 32 to 3182 -150 to 850 -199 to 999 -199 to 750 -199 to 999 -199 to 999 -199 to 999 -199 to 400 -199 to 750 N/A N/A ORDERING INFORMATION ATC550S00000 ATC550S10000 ATC550 Temperature Controller with Aux Relay output ATC550 Temperature Controller with Aux 12VDC SSR output Thermocouple (J,K,T,R,S) / 3-wire RTD (Pt100) 250 ms 0.2 to 10.0 seconds °C / °F selectable For J, K & T inputs: 0.25% of F.S. ±1° For R & S inputs: 0.5% of F.S. ±2° For RTD inputs: 0.1% of F.S. ±1° Digital Filter: Programmable from 0.05 seconds to 6.4 seconds Excitation: 5, 10, 12, and 24 Vdc @ 25 mA, firmware selectable Setpoint Adjustment: -9999 to +9999 counts Control Action: PID or ON-OFF Proportional Band (P): 1.0 to 400.0° (0.0 to 400.0° in cooling) Times: 0 to 9999 sec Integral (I); 0 to 9999 sec Derivitive (D) Cycle Time: 0.1 to 99.9 sec (heat or cool) Hysteresis Width: 0.1 to 99.9° Manual Reset Value: -19.9 to 19.9° Heat-Cool Control: PID (with auto-tuning) Dead Band: Programmable from setpoint low limit to setpoint high limit Control Output: One, field selectable as relay or SSR drive SPST Relay: Single pole, single throw normally open contact, 250 Vac or 30 Vdc at 5 A (resistive load) SSR Drive: Voltage pulse, 12 Vdc ±10%, 50 mA Aux. (Alarm) Output: One, factory set as either SPST relay or SSR drive, Selectable Deviation or Absolute control mode, 0.1 to 99.9° adjustable hystersis Display: 4 digit 7 segment dual LED display Height: 0.3785” (upper), 0.2720” (lower) LED Indication: Relay ON, Tune, Soak Time Operating Temp.: 0 to 50°C (32 to 122°F), <95% RH (non-condensing) Line Voltage: 85-270V AC/DC, 50-60 Hz, 6VA max. at 230V AC Dimensions: 52x52x100 mm, 46x46 mm panel cutout (1/16 DIN) 6a Fuji Temperature and Process Controllers • PID Plus Self Tuning and Fuzzy Control • Large LED Display L CONTROLLERS • NEMA-4X/IP66 Waterproof Faceplate • Up to 16 Ramp/Soak Segments in Two 8Segment Patterns PXR3 • Heating/Cooling Control • Timer Function • Dual Control Output Option • Digital Input Option • Analog Retransmission Option • Programmable Alarms Option • Heater Break Alarm Option • RS485 (Modbus™ Protocol) Option • Free Windows®- Based Software • Manufactured in an ISO 9001 Facility • 3-Year Warranty L PXR5 L PXR9 L PXR4 SPECIFICATIONS Input Input signal: Input filter: Input sampling cycle: Display Indication accuracy (at 23°C): Control Function Control action: Control Outputs Relay contact: SSR: 4 to 20 mA DC: Alarm (option) Alarm type: Alarm ON-delay: Process alarm output: Heater burnout option (not available on PXR3): Heater burnout alarm output: 7 TC: J, K, R, B, S, T, E, N, PL2. RTD: Pt100. Voltage, current. For 1 to 5V/4 to 20 mA DC, 0 to 5V/0 to 20 mA DC 0 to 900.0 sec set in 0.5 sec steps 0.5 sec TC: ±0.5% FS ± 1 digit ±1°C. TC R (0 to 500°C): ±1% FS ± 1 digit ±1°C. TC B (0 to 400°C): ±5% FS ± 1 digit ±1°C. RTD, Voltage, Current: ±0.5% FS ± 1 digit On/Off; PID control (with auto-tuning, selftuning); Fuzzy Control (with auto-tuning) PXR3 & Output 2: SPST contact, 220 VAC/30 VDC, 3A (resistive load). PXR4, 5, 9: SPDT, 220 VAC/30 VDC, 3A (resistive load) PXR3: 12 to 16 VDC PXR4, 5, 9: ON–17 to 25 VDC; OFF–0.5 VDC or less. Max. current: 20mA or less PXR3: Allowable load resistance 100 to 500Ω. PXR4, 5, 9: 600Ω or less Absolute alarm, deviation alarm, zone alarm with upper and lower limits for each; hold function available; alarm latch function provided 0 to 9999 sec in 1 sec steps Relay contact: SPST, 220 VAC/30 VDC, 1A (resistive load); Max. 2 points (PXR3), max. 3 points (PXR4, 5, 9) Alarm setting range: 1 to 50A. Available only when control output is relay or SSR drive Relay contact: SPST, 220 VAC/30 VDC, 1A (resistive load); 1 output point Remote Setpoint (option) Input signal: 1 to 5 VDC, 1 point Accuracy: ±0.5% ±1 digit Input sampling cycle: 0.5 sec Input impedance: ≥1MΩ Digital Input (option) Points: 1 or 2; contact closure. 5 VDC, approx. 2mA Function (select one): Set value (SV, SV1 to 3) changeover, start/stop control action, start/reset ramp/soak action, start/stop auto-tuning, cancel alarm latch, start incorporated timer Retransmission Output (option) Output signal: 4-20 mA DC Load resistance: 500 ohms or less Output accuracy: ±0.3% FS Output selection: PV, SV, MV, DV (SV-PV) Timer Function (option) Start: By digital input option Setting: 0 to 9999 sec set in 1 sec steps Action: Event ON-delay or OFF-delay Signal output: Alarm output relays used; 2 points are available Communication Function (option) Physical specifications: EIA RS485 Protocol: Modbus (RTU). Free Windows®-based software, PXR-LITE included Connection aspect: Multi-drop up to 31 controllers Communication Total extension 500m or less distance: Operating Conditions and Structure Operating 14 to 122°F (-10 to 50°C) temperature: Mounting method: Panel flush mounting. PXR3 can be DIN-rail mounted using the optional adapter External terminal: Screw terminal Fuji Temperature and Process Controllers SPECIFICATIONS, CONTINUED Power supply voltage: Power consumption: Reference junction ±1°C at 23°C compensation accuracy: Dimensions (HxWxD): PXR3: 1/32 DIN (24 x 48 x 97mm). PXR4: 1/16 DIN (48 x 48 x 78.8 mm). PXR5: 1/8 DIN (96 x 48 x 78 mm). PXR9: 1/4 DIN (96 x 96 x 79.5 mm) PXR3 ORDERING INFORMATION To order–Insert Number Code for Each Letter to Select Catalog Number. Order Example: PXR3-T-A-Y1-4-V-0A1 PXR4, 5, 9 ORDERING INFORMATION To order–Insert Number Code for Each Letter to Select Catalog Number. Order Example: PXR4-T-A-Y1-4-V-0A1 A - B - C - D - E - F - G A - B - C - D - E - F - G A A Front Panel Size PXR3 1/32 DIN (24x48mm) B Input Signal T Thermocouple (°C) R Thermocouple (°F) N RTD, Pt100 ohm, 3-wire type (°C) S RTD, Pt100 ohm, 3-wire type (°F) B 4-20mA DC, 1-5V DC A 0-20mA DC, 0-5V DC C Control Output 1 A Relay contact output C SSR or SSC drive output E 4-20mA DC output D Control Output 2 Y1 None A1 Relay contact output C1 SSR or SSC drive output E1 4-20mA DC output E Alarm Options 4 None 5 High/low alarm 1 point G High/low alarm 2 points1 F Power Supply V Standard (100-240 VAC, 50/60Hz) B 24V AC/DC (50/60Hz) G Additional Functions 0A1 None MA1 RS485 communication (Modbus) QA1 Retransmission + DI 1 point RA1 Retransmission (4-20mA DC) TA1 Digital Input (DI) x 2 VA1 RS485 communications (Modbus) + DI 1 point 1 High/low alarm 2 points not available when control output 2 is selected B C D E F G ORDERING INFORMATION – ACCESSORIES CTL-6-S CTL-12 RSFC24 PXR3 Rail Adapter PXR4 Terminal Cover Current transformer for 1-30A Current transformer for 20-50A RS485 to RS232 signal converter Mounting adapter for DIN rail installation for PXR3 Terminal block protective cover for PXR4 CONTROLLERS 100 (-15%) to 240V (+10%) AC, 50/60Hz; 24V (±10%) AC/DC PXR3: 6VA (100 V), 8VA (220V, 24V). PXR4: 8VA (100V), 10VA (220V), 12VA (24V). PXR5, 9: 10VA (100V), 12VA (220V, 24V) Front Panel Size PXR4 1/16 DIN (48x48mm) PXR5 1/8 DIN (48x96mm) PXR9 1/4 DIN (96x96mm) Input Signal T Thermocouple (°C) R Thermocouple (°F) N RTD, Pt100 ohm, 3-wire type (°C) S RTD, Pt100 ohm, 3-wire type (°F) B 4-20mA DC, 1-5V DC A 0-20mA DC, 0-5V DC Control Output 1 A Relay contact output C SSR or SSC drive output E 4-20mA DC output1 Control Output 2 Y1 None A1 Relay contact output C1 SSR or SSC drive output E1 4-20mA DC output1 R1 Retransmission (4-20mA DC) Alarm Options 4 None 6 Heater break alarm1,2 G High/low alarm 2 points H High/low alarm 2 points + heater break alarm1,2 M Alarm 3 points D Remote setpoint3 P Remote setpoint + alarm 2 points3 Power Supply V Standard (100-240V AC, 50/60Hz) B 24V AC/DC (50/60Hz) Additional Functions 0A1 None MA1 RS485 communication (Modbus) SA1 Digital Input (DI) x 1 TA1 Digital Input (DI) x 21 VA1 RS485 communications (Modbus)+ DI1,3 1 Heater break option not available with 4-20mA output, or with 2 digital inputs, or with RS485 +1 digital input. 2 Current transformer needed with heater break option. 3 Remote setpoint option not available with RS485 +1 digital input. 8 Newport Humidity & Temperature Controllers • • • • • • • • • • • Dual Loop Control High Accuracy ±0.5°C and ±2% RH 4 Popular DIN Sizes 2 Control or Alarm Outputs (optional) Choice of Relays, SSR, DC Pulse, Analog Voltage and Current Full Autotune PID Control Ethernet or RS-232/RS-485 (optional) User-friendly, Simple to Configure Programmable Ramp and Soak for Humidity and/or Temperature RH / Temperature Probe included NEMA 4, IP65 Front Bezel The NEWPORT® iTH Series monitor and control both temperature and relative humidity. The meters accurately display humidity, temperature, or dew point. They also provide dual loop control for both humidity and temperature and are easily programmed for any control or alarming requirement from simple on-off to full autotune PID control. The LED displays can be programmed to change color between Green, Amber, and Red at any set point or alarm point. The iTH family is available in four true DIN sizes with NEMA 4, IP65 splash resistant bezels: the ultra compact 1/32 DIN, the popular midsize 1/16 DIN square bezel with dual display, the 1/8 DIN vertical, and the 1/8 DIN horizontal with the big bright 21mm digits. ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: NE/iTH - i8DH - 00 - 5 - C24 A – B – C – D – E – F A SPECIFICATIONS Sensor Specifications Relative Humidity Accuracy/Range: ±2% for 10 to 90% RH 3% for 0 to 10% RH and 90 to 100% RH Non-Linearity: ±3%; Hysteresis: 1% RH Temperature Accuracy/Range*: ±0.5°C (±1°F) for 0 to 80°C (32 to 176°F) ±1°C (±2°F) for -40 to 0°C and 80 to 124°C (-40 to 32°F and 176 to 254°F) *Note: extended temperature range is for Probe only, the iTH’s operating temperature is 0-50°C. Resolution: 0.03%,12 bit for RH; 0.01°C 14 bit for Temperature Response Time: 4 sec for RH; 5 sec for Temp (63% slowly moving air) General A/D Conversion: Reading Rate: Digital Filter: Display: 12 bit RH and 14 bit Temp. 2 samples per second max. Programmable 4-digit, 9-segment LED • 10.2 mm (0.40"): i32, i16D, i8DV • 10.2 mm (0.40”) & 21 mm (0.83”): i8DH Red, green and amber programmable colors for process variable, set point and temp units Operating 0 to 50°C (32 to 122°F), Temperature: 90% RH non-condensing 8a B C D E F Model # NE/iTH-i8DH NE/iTH-i8DV NE/iTH-i16D NE/iTH-i32 Outputs (2 digits) 0 0 2 2 2 3 2 4 3 3 4 2 4 3 4 4 5 2 Description Temperature and RH Input 1/8 DIN Dual Display Horizontal Temperature and RH Input 1/8 DIN Dual Display Vertical Temperature and RH Input 1/16 DIN Dual Display Temperature and RH Input 1/32 DIN Single Display Monitor version, no control outputs. Two solid state relays (SSR's): 0.5 A @ 120/240 Vac continuous SSR and relay: Form “C” SPDT 3A @ 120Vac, 3A @ 240Vac SSR and pulsed 10 Vdc @ 20 mA (for use with external SSR) 2 Relays: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac Pulsed 10 Vdc @ 20 mA (for use with external SSR) and SSR Pulsed 10 Vdc @ 20 mA (for use with external SSR) and relay Two pulsed 10 Vdc @ 20 mA (for use with external SSR) Analog Output selectable as either control or retransmission of process value; 0 to 10 Vdc or 0-20 mA @ 500 ohm max. & SSR 5 3 Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm max & Relay 5 4 Analog Out 0 to 10Vdc or 0-20mA @ 500 ohm max & Pulse 10Vdc RH/Temperature Probe (must select one) 2 2” (51mm) Probe for iTH with 3ft (0.9m) cable 5 5” (137mm) Probe for iTH with 20ft (6.1m) cable Power Supply * Standard power input: 90-240 Vac ±10%, 50-400 Hz, 110-375 Vdc, equivalent voltage (*no entry required) DC Low Voltage Power Option: 12 - 36 Vdc; 24 Vac ±10% Network Options EI Ethernet with Embedded Web Server C24 Isolated RS-232 and RS-485/422. (MODBUS & ASCII) C4EI Ethernet with Embedded Web Server + Isolated RS-485/422 hub for up to 31 devices Factory Setup FS Factory Setup and Configuration (requires Network Option) *1 -C4EI or -EI option is not available on the 1/32 DIN. Consult Sales for other Ethernet devices that can connect to an iTH-i32xx-x-C24 . West Process Controller KEP Batch Controller CONTROLLERS • Single or Two Loop • Graphical & Text LCD Display • USB, RS485, Ethernet • Profiling & Datalogging Options • 1/4 DIN Size • 4 Plug-in Module Slots • UL, CE • Display Rate, Batch Size and Number of Batches or Grand Total • 5 Digit Scaling Factor • Pulse Input • 2 Relay Outputs • Analog Output or Serial/Modbus Options • NEMA 4X / IP65 Front Panel Pro EC44 MB2 Simplifying user operation with an intuitive HMI, fast access front USB port and easy-to-use configuration and simulation software, Blue Control©. SPECIFICATIONS Input 1 & 2: T/C: J, K, T, E, R, S, D, B, C, L, N, PtRh RTD: 3-wire Pt100, Ni120 DC: 0-50mV, 10-50mV, 0-5V, 0-10V, 1-5V, 2-10V, 0-20mA, 4-20mA Aux. Input: 0-5V, 0-10V, 1-5V, 2-10V, 0-20mA, 4-20mA Loops: 1 or 2 control loops Control: ON/OFF, PID heat only & Heat/Cool, Valve Motor Drive, Ratio, Cascade Profiler: 255 segment profiler shared in 64 programs PID: 5 PID sets manual or automatic gain scheduling Alarms: 7 can be set as high, low, deviation, band, control loop, rate of change. Also alarms for sensor break, recorder memory, power Datalogging: 1sec - 30min interval, non-volatile memory, real time clock USB: Host for configuration (read/write) and logged data (read) Modbus: Ethernet Modbus TCP; RS485 Modbus RTU (Master/Slave) I/O: Up to 2 analog inputs, 9 digital inputs, remote setpoint input; 9 outputs (relay, SSR drive, triac, linear DC, excitation) Display: 160x80 graphic LCD with red/green backlight, 66x37mm ORDERING INFORMATION The Mini-Batcher is a 6 digit totalizer and 4.5 digit ratemeter with two relay outputs. One output is dedicated to the batch amount (Preset A), the other can be activated for Prewarn or Batch/Grand Total. The unit can count up to the preset (reset to 0) or down from the preset (set to preset). Start, Stop and Reset functions can be activated from the front panel or remote inputs. Up to 247 units can communicate to a host computer using Modbus RTU protocol. Alternately, an analog output (assignable for Rate or Batch Amount) can be ordered for data logging. SPECIFICATIONS Display: Input: Ratemeter Display: Accuracy: Sampling Rate: Scaling Factor: Presets: Front Panel Lockout: To Order- Insert Code for Each Letter to Select Catalog Number. Example: EC44-0-C-P-0-2-1-1-8-1-T-1-0-1 Relays: EC44-0- A – B – C – D – E – F – G – H – I – J – K –1 Relay B On Time: Power Consumption: Output Power: A B C D E F G Type C Controller U Controller with USB D Controller/Recorder (Datalogger) R Controller/Recorder w/USB Profiler O None P Profiler Power Supply O 100-240V AC 2 24-48V AC/DC H, I Plug-in Module Slot 2 & 3 Control Loops O None 1 One 1 Relay Output SPDT A One + Auxiliary 2 DC SSR Drive 2 Two Y Dual DC SSR Drive Output Base Option 1 8 Triac Output 1 Relay Output SPST 9 Dual relay Output SPST 2 Relay + Linear DC Out T 24VDC Transmitter Supply Base Option 2 J Plug-in Slot A 0 None O None 1 Relay Output SPST 1 RS485 Modbus RTU 2 Relay + Linear DC Out 3 1 Digital Plug-in Module Slot 1 H, I Plug-in Module SlotInput 2&3 Auxiliary Input O None O 4 None Ethernet 1 Relay Output SPDT 1 5 Relay OutputModbus SPDT TCP K 2Option CDC SSR Drive 2 DC SSR Drive None L Linear DC Output Y 0 Dual DC SSR Drive Output 1 8 Digital Inputs 8 Triac Output 6 digit, 0.55" high LED Pulse, 50VDC max, 10kΩ resistance Units per second, minute or hour 0.01% FS (±1 digit) 2 to 24 seconds 0.0001 to 99999 (converts input pulses to engineering units) Two, 5 digits each Complete locked out (except Start/Stop) or the presets can remain accessible Two N.O. 5A, 120/240VAC or 28VDC. (N.C. contacts and NPN transistor output available with solder jumpers) 0.01 to 99.99 sec. or latched (0.00 setting) 6.5VA AC or 250mA DC max. +12VDC @ 50mA, unregulated -10 + 50% (AC powered units only) 0-54°C (32-130°F), <90% RH, non-condensing EEPROM stores data for 10 years if power is lost 4.44"W x 2.63"H x 4.25"D (113 x 67 x 108mm) 3.622" x 1.772" (92 x 45mm) Operating Temperature: Memory: Dimensions: Cutout: ORDERING INFORMATION To Order—Insert Code for Each Letter to Select Catalog Number. Order Example: KE/MB2C34 KE/MB2 A A 110 VAC ±15% or 12-15 VDC 220 VAC ±15% or 12-15 VDC 24 VAC ±15% or 12-15 VDC Count Inputs 3 3M C C Operating Voltage A B C B B 4-30 VDC or 0-1VDC pulse, 10kHz max. 30mV mag. pickup, 5kHz max. Options 1 2 3 4 A RS232 Comm., KEP protocol RS422 Comm., KEP protocol RS232, Modbus RTU RS422/RS485, Modbus RTU Analog Output (4-20/0-20 mA) 9 Partlow DIN Controllers L • Dual 4 digit display • User selectable input type • Up to three outputs • 3 year warranty 1801+ SPECIFICATIONS Input: SPECIFICATIONS Inputs: Accuracy: Input Sample Rate: Impedance: Outputs: Sensor Break Detect: Communications: Operating Temperature: Supply Voltage: Protection: T/Cs: J, K, C, R, S, T, B, L, N, Pt 20% Rh vs. Pt40% Rh RTD: 3-wire Pt100, <50Ω per lead (balanced) DC (scalable –1999 to +9999): 0–5, 1–5, 0–10 or 2–10VDC; 0–50mV, 10–50mV; 0–20mA, 4–20mA ±0.1% of input range ±1 digit (T/C CJC better than 1°C) 4 per second; 14 bit resolution >10MΩ for T/C and mV ranges, 47kΩ for V ranges, 5Ω for mA ranges Relay: SPDT, 240VAC@2A resistive SSR Driver: >10VDC nominal into 500Ω min. DC Linear: 0–20, 4–20mA into 500Ω max.; 0–10, 1–5, 2–10, 0–5V into 500Ω min. Triac: 0.01-1A AC, 20-280Vrms, 47–63Hz <2 seconds 2-wire, RS-485, Modbus or ASCII 32–131°F (0–55°C), <95% RH non-condensing 100–240V, 50/60Hz or 20–48VAC / 22–65 VDC IP66, NEMA 4X (front panel) ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: PA/1160114300 A A B C D E F Basic Unit PA/1160 1160+ PID Controller (1/16 DIN) PA/1400 1400+ PID Controller (1/4 DIN) PA/1800 1800+ PID Controller (1/8 DIN) B–C–D Option Option Option Slot 1 Slot 2 Slot 3 0 0 0 None 1 1 1 Relay output 2 2 2 DC drive output for SSR 3 3 3 Linear DC output 4 4 24V Transmitter power supply* 8 8 8 Triac output* E Option Slot A 0 None 1 RS-485 serial comm 2 Green upper display 3 RS-485 & green upper display 4 Green lower display 5 RS-485 & green lower display 6 Green upper & lower display 7 RS-485 & two green displays 8 Digital input 9 Digital input & green upper display A Digital input & green lower display B Digital input & two green displays C Basic Remote Setpoint Input (RSP) D Basic RSP & green upper display E Basic RSP & green upper display F Basic RSP & two green displays F Power Supply 00 100-240VAC 02 24-48V AC/DC *max. one transmitter supply, two triac outputs per unit CONTROLLERS 1160+ • 1/16, 1/8 & 1/4 DIN Sizes L • Dual setpoints with optional remote selection • Plug-in output modules • Customizable operator menus • Process and loop alarms • Full PID or ON/OFF control • Heat/Cool operation (with dual outputs) • Selectable pre-tune, self-tune, manual tune Partlow Limit Controllers Output: Output Function: Control: Operating Temperature: Protection: Thermocouple J, K, C, R, S, T, B, L, N 3 wire 100 ohm Pt RTD DC linear V (scalable –1999 to +9999) DC linear mA (0–20 or 4–20) DC linear mV (0–50 or 10–50) Relay SPDT 2A, 240VAC resisitive SSR drive >10VDC into 500Ω min Triac 0.01–1A, 20–280VAC Limit, alarm (process, deviation/band) High/low limit 0–55°C, 20–95% RH IP66, NEMA 4X front; IP20 behind panel ORDERING INFORMATION To Order–Insert Number Code for Each Letter to Select Catalog Number. Order Example: PA/1161 010602 A B C D E F A Basic Unit PA/1161 1/16 DIN Limit Controller PA/1401 1/4 DIN Limit Controller PA/1801 1/8 DIN Limit Controller B Option Slot 1 0 Relay Output C Option Slot 2 0 None 1 Relay Output 2 DC drive output for SSR 3 Linear DC output 4 24V Transmitter power supply* 8 Triac output D Option Slot 3 0 None 1 Relay Output 2 DC drive output for SSR 3 Linear DC output 4 24V Transmitter power supply* 8 Triac output E Option Slot A 0 None 1 RS-485 serial comm 2 Green upper display 3 RS-485 & green upper display 4 Green lower display 5 RS-485 & green lower display 6 Green upper & lower display 7 RS-485 & two green display 8 Digital input 9 Digital input & green upper display A Digital input & green lower display B Digital input & two green displays F Power Supply 00 100–240VAC 02 24–48V AC/DC *One transmitter supply per unit 10 Newport Digital Indicator Controllers ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: Q2001-CVR6 A A B C D E F B C D – E F Display Resolution and Case Style Q2 ±1999 Counts (31⁄2-digits) Q3 ±1999 with “Infinity™ Family Bezel and Adapter” Q9 ±9999 Counts (4-digits) Q8 ±9999 with “Infinity™ Family Bezel and Adapter” Display Type and Meter Power 0 LED, 120 VAC (49/440 Hz) (BQ20 or BQ90) 2 LED, 240 VAC (49/440 Hz) (BQ22 or BQ92) 4 LED, 9–32 VDC (isolated) (BQ24 or BQ94) 6 LED, 5 VDC** (BQ26 or BQ96) 8 LED, 24 VAC (BQ28 or BQ98) A LED, 26-–56 VDC (isolated) (BQ2A or BQ9A) **Not available with AC AVG or True RMS inputs Analog Output Adders Max one analog output in addition to recorder output 0 ±1 or ±2 V recorder output, non-isolated 1 0–5 VDC, non-isolated (BA01) 2 0–10 VDC, non-isolated (BA01) 3 0–1 mA, source or sink, non-isolated (BA01) 4 4–20 mA, source or sink, non-isolated (BA01) 6 4–20 mA, isolated (BA03) Control Output Adders 0 None 1 Dual-Setpoint 10A Relay (BDT1) 4 BCD (BDD2) 5 Single-Setpoint 10A Relay (BDS1) Signal Conditioning Input Adders ❑ Select from Input Table Green LEDs for Display G Green 0 None INPUT TABLE Code Q2000/Q3000 Q8000/Q9000 DC Voltage Input AVR1 ±199.9 mV ±99.99 mV AVR2 ±1.999V ±999.9 mV AVR3 ±19.99V ±9.999V AVR4 ±199.9V ±99.99V DC Current Input BCR1 ±19.99 µA ±9.999 µA BCR2 ±199.9 µA ±99.99 µA BCR3 ±1.999 mA ±999.9 µA BCR4 ±19.99 mA ±9.999 mA BCR5 ±199.9 mA ±99.99 mA BCR6 ±1.999A ±999.9 mA AC AVG Voltage Input CVR2 199.9 mV 99.99 mV CVR3 1.999V 999.9 mV CVR4 19.99V 9.999V CVR5 199.9V 99.99V CVR6 650V 650.0V AC AVG Current Input DCR1 19.99 µA 9.999 µA DCR2 199.9 µA 99.99 µA DCR3 1.999 mA 999.9 µA DCR4 19.99 mA 9.999 mA DCR5 199.9 mA 99.99 mA DCR6 1.999A 999.9 mA DCR7-(*) (1) 5A = 1000, (2) 5A = 1500, (3) 5A = 2000, (4) 5A = 300, (5) 5A = 500 10a Quanta® Standard Features • Field Selectable Input Ranges • Recorder Analog Output • Front-Panel Accessible Span Adjustment • Bright, 0.56" (14.2 mm) LED Display • Display Hold and Test • Screw-Terminal Barrier Strip • Optional Relay Outputs • 1⁄8 DIN Case Options • Analog Output for User-Selected Span • Single-Setpoint 10A SPDT Relay • Dual-Setpoint with Two 10A SPDT Relays • Parallel BCD Output, Isolated Quanta ▲ INPUT TABLE (CONT’D) Code Q2000/Q3000 Q8000/Q9000 True-RMS Voltage Input FVR2 199.9 mV 99.99 mV FVR3 1.999V 999.9 mV FVR4 19.99V 9.999V FVR5 199.9V 99.99V FVR6 650V 650.0V True-RMS Current Input GCR1 19.99 µA 9.999 µA GCR2 199.9 µA 99.99 µA GCR3 1.999 mA 999.9 µA GCR4 19.99 mA 9.999 mA GCR5 199.9 mA 99.99 mA GCR6 1.999A 999.9 mA GCR7-(*) (1) 5A = 1000, (2) 5A = 1500, (3) 5A = 2000, (4) 5A = 300, (5) 5A = 500 Frequency/Rate Input (100 mV Hystersis): H 1000 Hz = 1000 1000 Hz = 0–9999 Type J Thermocouple Input JDC1 -40 to +760°C -40.0 to +760.0°C JDF1 -40 to +1400°F -40.0 to +999.9°F Type K Thermocouple Input KDC1 -40 to +1260°C -40.0 to +999.9°C KDF1 -40 to +1999°F -40.0 to +999.9°F Type T Thermocouple Input TDC1 -184 to +371°C -184.0 to +371.0°C TDF1 -300 to +700°F -300.0 to +700.0°F RTD (Pt 100) Input Alpha = 0.00385 MDC1 -200 to +830°C -200.0 to +830.0°C MDF1 -328 to +1526°F -328.0 to +999.9°F RTD Input, High Resolution Alpha = 0.00385 RDC1 -199.9 to +199.9°C Not available with Q8/Q9 RDF1 -199.9 to +199.9°F Not available with Q8/Q9 3-Wire Ratio Potentiometer Input NPR1 1000 = 1 kOhm 9999 = 1 kOhm NPR2 1000 = 5 kOhm 9999 = 5 kOhm 2- or 4-Wire Resistance Input OOR1 19.99 Ohm Not available with Q8/Q9 OOR2 199.9 Ohm Not available with Q8/Q9 OOR3 1999 Ohm Not available with Q8/Q9 OOR4 19.99 kOhm Not available with Q8/Q9 Process Signal Input P 4–20 mA = 0–100.0 4–20 mA = 0–99.99 Process Signal Input Excitation set to 15 VDC E 4–20 mA = 0–100.0 4–20 mA = 0–99.99 Strain-Gage/Microvolt Input Excitation set to 10 VDC (30 mA max) S ±100 mV = ±100.0 ±100 mV = ±99.99