AcuDC 200 Series DC Power and Energy Meters AcuDC 211 AcuDC 212 AcuDC 223 AcuDC 222 AcuDC 213 AcuDC 221 WESCHLER INSTRUMENTS ISO9001 Certified 800-903-9870 440-378-6580 www.weschler.com info@weschler.com AcuDC 200 Series DC Power Meter INTRODUCTION AcuDC 200 series DC power meter can be used for monitoring and controlling in DC systems. These meters can measure a wide range of parameters such as voltage, current, power and energy. There are digital inputs for switch monitoring and relay outputs for remote controlling as well as an over-range alarming feature for voltage and current. Large signals, such as current and voltage can be converted to smaller signals using AO output. All data in the meter is accessible via RS485 using open Modbus RTU protocol. APPLICATIONS • Solar and wind nergy energysystems systems • Industrial control systems • DC energy management systems • Large UPS systems FEATURES • DC power system metering • Monitor and control power switches • Alarming and analog output • Standard DIN sizing (96×48mm) allows for easy panel installation • Can be used in SCADA, PLC systems • Large character LCD display with vivid blue backlight • Wide operation temperature range SPECIFICATIONS Function AcuDC 211 AcuDC 212 AcuDC 213 AcuDC 221 AcuDC 222 AcuDC 223 Voltage V (Volt) Current I (Amp) Metering Power P (W) Energy E (kWh) IO DI RO 4~20mA AO 0~5V Over /Under Limit Alarm Alarming Communication Display RS485, Modbus LCD Dimensions Note: Function 96×48×71mm Option Blank NA TYPICAL WIRING Vdc+ Vdc+ Vdc- Vdc- Vdc+ 8 5 V+ I- 8 Vdc+ Current Wiring 1 Vdc+ Vdc- I+ AcuDC 200 I- Load Current and Voltage 1 14 AO 15 11 S3 AO+ AO- S2 10 Resistor R S4 12 Digital Input Relay AcuDC 200 S1 9 AC / DC –+ 13 19 DI1 DI2 DI3 DI4 DIC 18 NC 4 R21 R22 POWER N G 2 3 17 Current and Voltage 3 DIC 13 V- Auxiliary power Current and Voltage 2 DIGITAL INPUTS DI2+ DI3+ DI4+ 10 11 12 R12 8 I- 16 AcuDC 200 Load L 1 Relay Output 7 I+ Hall 0~5V Shunt 75mV 6 V- AcuDC 200 Load DI1+ 9 8 AcuDC 221 Auxiliary power R11 5 V+ 8 I- 7 I+ Current Wiring 3 Current Wiring 2 6 V+ Vdc- 5 V+ 7 I+ 5 I- Load AcuDC 200 6 V- 7 I+ Load Vdc- AcuDC 200 Hall Voltage Wiring AcuDC 200 7 Load 8 0~5V I+ Vdc+ Vdc- I- Shunt 7 6 V- 75mV AcuDC 200 AcuDC 200 Vdc+ Vdc- AO AO+ AO14 15 VOLTAGE V+ V5 6 R11 16 Relay Output (Voltage<250Vac or 30Vdc I<3A ) RELAY OUTPUTS R12 R11 R22 17 18 19 A 20 RS-485 B 21 16Vdc<Voltage<30Vdc I<20mA Analog Output 4-20mA, R<500Ω S 22 CURRENT I+ I7 8 Power 100~240Vac, 50/60Hz 100~300Vdc 2W DIMENSIONS 44.00 (1.73 ) 48.00 (1.89) 48.00 (1.89 ) Unit: mm (inches) 96.00 (3.78) 60.00 (2.36) CUT-OUT 90.00 (3.54) 71.00 (2.80) FRONT SIDE PANEL CUTOUT TECHNICAL SPECIFICATIONS Metering Parameters Accuracy Resolution Voltage 0.2% 0.01V Current 0.2% 0.005A Power 0.5% 0.01W Energy 0.5% 0.1kWh Drift with Temperature: <100ppm/˚C Stability: 0.5‰/year Analog Output (AO) Range 0~600V 0.005~9999A 0.01~6,000,000W 0.1~99999.9kWh Output Range Resolution Output Capability Communication Voltage Input Range Input Impedence Load: Accuracy 0~600V (1200V with optional Hall Element) 2MΩ <0.2W 0.2% Current Input Range Shunt Hall Element Power Consumption Accuracy 0~10A (Direct input) 0~9999A (Extra current shunt or Hall element, with programmable range) 50~100mV (programmable) 0~5V, 0~4V, 0~20mA, 4~20mA 2W (max) 0.2% Digital Input (DI) Optical Isolation Input Form Input Resistance Input Voltage Range Close Voltage Max Input Current 4~20mA or 0~5V 12bit 4~20mA Max Resistance: 500Ω 0~5V Max Current: 20 mA Type Protocol Baud Rate Isolate Voltage RS485, Half Duplex, Optical Isolated Modbus RTU 1200~19200bps 2500Vac Relay output (RO) Output Form Max Load Voltage Max Load Current On Resistance Isolate Voltage Mechanical Endurance Power Supply Input Power Consumption 2500Vac rms Contact with Power Supply 2KΩ (typical) 16~30Vdc >16Vdc 20mA Mechanical Contact, Form A 250Vac/30Vdc 3A 100MΩ (Max) 4000Vac 5×106 cycles (P1) 100~240Vac, 50/60Hz 100~300Vdc (P2) 20~60Vdc 2W Operating Environment Operation Temp Storage Temp Humidity Altitude -25˚C~+70˚C -40˚C~+85˚C 5%~95% Non-condensing 2000m ORDERING INFORMATION Voltage Current Aux. Power Supply DI Option RO Option AO Option AcuDC 0RO: No Relay Output 2RO: 2 Relay Output 0DI: No Digital Input 4DI: 4 Digital Input 0AO: No Analog Output AO1: 4~20mA AO2: 0~5V P1: 100~240Vac, 50/60Hz 100~300Vdc P2: 20~60Vdc A0: Direct Current Input (0~10Amp) A1: Current Shunt Input Option (50~100mV) A2: Hall Element Input Option (0~20mA or 4~20mA) A3: Hall Element Input Option (0~4V or 0~5V) 300V: 300Volts 600V: 600Volts 1000V: 1000 Volt External Hall Element (external 24VDC power supply required) AcuDC 211 AcuDC 212 AcuDC 213 AcuDC 221 AcuDC 222 AcuDC 223 AcuDC Series Meter Ordering Example: AcuDC 223 - 600V - A0 - P1 - 4DI - 2RO - 1AO1 Distributor & Meter Modification Center: Los Angeles-Toronto-Beijing North America Toll Free: 1-877-721-8908 Web: www.accuenergy.com Email: marketing@accuenergy.com WESCHLER INSTRUMENTS phone: 800-903-9870 440-378-6580 fax: 800-903-9590 440-238-0660 www.weschler.com info@weschler.com Revision Date: Sep., 2011 Document # 1501E1121